Med Phys ; 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39032078

RESUMEN

BACKGROUND: Surrogate-based motion compensation in stereotactic body radiation therapy (SBRT) strongly relies on a constant relationship between an external breathing signal and the internal tumor motion over the course of treatment, that is, a stable patient-specific correspondence model. PURPOSE: This study aims to develop methods for analyzing the stability of correspondence models by integrating planning 4DCT and pretreatment 4D cone-beam computed tomography (4DCBCT) data and assessing the relation to patient-specific clinical parameters. METHODS: For correspondence modeling, a regression-based approach is applied, correlating patient-specific internal motion (vector fields computed by deformable image registration) and external breathing signals (recorded by Varian's RPM and RGSC system). To analyze correspondence model stability, two complementary methods are proposed. (1) Target volume-based analysis: 4DCBCT-based correspondence models predict clinical target volumes (GTV and internal target volume [ITV]) within the planning 4DCT, which are evaluated by overlap and distance measures (Dice similarity coefficient [DSC]/average symmetric surface distance [ASSD]). (2) System matrix-based analysis: 4DCBCT-based regression models are compared to 4DCT-based models using mean squared difference (MSD) and principal component analysis of the system matrices. Stability analysis results are correlated with clinical parameters. Both methods are applied to a dataset of 214 pretreatment 4DCBCT scans (Varian TrueBeam) from a cohort of 46 lung tumor patients treated with ITV-based SBRT (planning 4DCTs acquired with Siemens AS Open and SOMATOM go.OPEN Pro CT scanners). RESULTS: Consistent results across the two complementary analysis approaches (Spearman correlation coefficient of 0.6 / 0.7 $0.6/ 0.7$ between system matrix-based MSD and GTV-based DSC/ASSD) were observed. Analysis showed that stability was not predominant, with 114/214 fraction-wise models not surpassing a threshold of D S C > 0.7 $DSC > 0.7$ for the GTV, and only 14/46 patients demonstrating a D S C > 0.7 $DSC > 0.7$ in all fractions. Model stability did not degrade over the course of treatment. The mean GTV-based DSC is 0.59 ± 0.26 $0.59\pm 0.26$ (mean ASSD of 2.83 ± 3.37 $2.83\pm 3.37$ ) and the respective ITV-based DSC is 0.69 ± 0.20 $0.69\pm 0.20$ (mean ASSD of 2.35 ± 1.81 $2.35\pm 1.81$ ). The clinical parameters showed a strong correlation between smaller tumor motion ranges and increased stability. CONCLUSIONS: The proposed methods identify patients with unstable correspondence models prior to each treatment fraction, serving as direct indicators for the necessity of replanning and adaptive treatment approaches to account for internal-external motion variations throughout the course of treatment.

2.
Strahlenther Onkol ; 199(7): 686-691, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37000223

RESUMEN

PURPOSE: 4D CT imaging is an integral part of 4D radiotherapy workflows. However, 4D CT data often contain motion artifacts that mitigate treatment planning. Recently, breathing-adapted 4D CT (i4DCT) was introduced into clinical practice, promising artifact reduction in in-silico and phantom studies. Here, we present an image quality comparison study, pooling clinical patient data from two centers: a new i4DCT and a conventional spiral 4D CT patient cohort. METHODS: The i4DCT cohort comprises 129 and the conventional spiral 4D CT cohort 417 4D CT data sets of lung and liver tumor patients. All data were acquired for treatment planning. The study consists of three parts: illustration of image quality in selected patients of the two cohorts with similar breathing patterns; an image quality expert rater study; and automated analysis of the artifact frequency. RESULTS: Image data of the patients with similar breathing patterns underline artifact reduction by i4DCT compared to conventional spiral 4D CT. Based on a subgroup of 50 patients with irregular breathing patterns, the rater study reveals a fraction of almost artifact-free scans of 89% for i4DCT and only 25% for conventional 4D CT; the quantitative analysis indicated a reduction of artifact frequency by 31% for i4DCT. CONCLUSION: The results demonstrate 4D CT image quality improvement for patients with irregular breathing patterns by breathing-adapted 4D CT in this first corresponding clinical data image quality comparison study.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Humanos , Tomografía Computarizada Cuatridimensional/métodos , Respiración , Pulmón , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Movimiento (Física)
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA