1.
Ann Biomed Eng ; 49(12): 3176-3188, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34580782

RESUMEN

Despite the potential for biomechanical conditioning with prosthetic use, the soft tissues of residual limbs following lower-limb amputation are vulnerable to damage. Imaging studies revealing morphological changes in these soft tissues have not distinguished between superficial and intramuscular adipose distribution, despite the recognition that intramuscular fat levels indicate reduced tolerance to mechanical loading. Furthermore, it is unclear how these changes may alter tissue tone and stiffness, which are key features in prosthetic socket design. This study was designed to compare the morphology and biomechanical response of limb tissues to mechanical loading in individuals with and without transtibial amputation, using magnetic resonance imaging in combination with tissue structural stiffness. The results revealed higher adipose infiltrating muscle in residual limbs than in intact limbs (residual: median 2.5% (range 0.2-8.9%); contralateral: 1.7% (0.1-5.1%); control: 0.9% (0.4-1.3%)), indicating muscle atrophy and adaptation post-amputation. The intramuscular adipose content correlated negatively with daily socket use, although there was no association with time post-amputation. Residual limbs were significantly stiffer than intact limbs at the patellar tendon site, which plays a key role in load transfer across the limb-prosthesis interface. The tissue changes following amputation have relevance in the clinical understanding of prosthetic socket design variables and soft tissue damage risk in this vulnerable group.


Asunto(s)
Adaptación Fisiológica , Muñones de Amputación , Tibia/cirugía , Miembros Artificiales , Fenómenos Biomecánicos , Humanos , Presión , Piel/lesiones , Traumatismos de los Tejidos Blandos/fisiopatología , Estrés Mecánico
2.
J Tissue Viability ; 30(3): 395-401, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34030943

RESUMEN

Temperature and humidity conditions at the interface between a support surface and the skin, termed microclimate, has been implicated in the development of pressure ulcers. Support surface technologies have been developed to control microclimate conditions, although only a few standard test methods exist to evaluate their performance. This study describes a combined experimental-computational approach to analyzing microclimate control systems. The study used a modified physical model protocol to evaluate two specific support surface systems involving a spacer fabric cover with i) no air flow and ii) an active fan. The physical model deposited moisture at a controlled rate for 25 min, and the microclimate conditions under the model and the surrounding area were monitored for 24 h. Using the experimental data as boundary conditions, a finite element model was developed using mass transport principles, which was calibrated using experimental results. Model inputs included mass density and mass diffusivity, resulting in an estimated absolute humidity change over time. The physical model tests revealed distinct differences between the support surfaces with and without active airflow, with the former having little effect on local humidity levels (RH>75% for 24hr). By contrast, there was a spatial and temporal change in microclimate with the active fan, with sensors positioned towards the source of airflow reaching ambient conditions within 24hr. The computational model was refined to produce comparable results with respect to both the spatial distribution of microclimate and the change in values over time. The combined experimental and computation approach was able to distinguish distinct difference in microclimate change between two support surface designs. The approach could enable the efficient evaluation of different mattress design principles to aid decision making for personalized support surface solutions, for the prevention of pressure ulcers.


Asunto(s)
Simulación por Computador , Microclima , Modelos Teóricos , Humanos , Humedad/efectos adversos , Úlcera por Presión/prevención & control , Desarrollo de Programa/métodos , Fenómenos Fisiológicos de la Piel , Temperatura
3.
Artículo en Inglés | MEDLINE | ID: mdl-33241703

RESUMEN

Respiratory masks are used to deliver non-invasive ventilation for cardiorespiratory pathologies. Masks must minimize skin tissue compression while maintaining a seal at the interface. Ill-fitting masks or those applied too tightly are implicated in pressure ulcer formation. This study aimed to analyse respiratory mask goodness of fit in a cohort of face shapes. A number of parameters were identified and analysed with a novel registration protocol. In the majority of cases, mask indentation exceeded the thickness of the interface material and significant gapping was observed. The size range was most appropriate for males, with only one size suitable for females.

4.
J Tissue Viability ; 29(4): 277-283, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32943281

RESUMEN

BACKGROUND: Diabetes-Related Foot Ulcers (DRFUs) are a common and devastating consequence of Diabetes Mellitus and are associated with high morbidity, mortality, social and economic costs. Whilst peak plantar pressures during gait are implicated cited as a major contributory factor, DRFU occurrence has also been associated with increased periods of sedentary behaviour. The present study was designed aimed to assess the effects of sitting postures on plantar tissue health. METHODS: After a period of acclimatisation, transcutaneous oxygen tensions (TCPO2) and inflammatory cytokines (IL-1α and IL-1RA) were measured at the dorsal and plantar aspects of the forefoot before, during and after a 20-min period of seated-weight-bearing in participants with diabetes (n = 11) and no diabetes (n = 10). Corresponding interface pressures at the plantar site were also measured. RESULTS: During weight-bearing, participants with diabetes showed increases in tissue ischaemia which were linearly correlated proportional to plantar pressures (Pearson's r = 0.81; p < 0.05). Within the healthy group, no such correlation was evident (p > 0.05). There were also significant increases in post seated weight-bearing values for ratio for IL-1α and IL-1RA, normalised to total protein, post seated weight-bearing in participants with diabetes compared to healthy controls. CONCLUSION: This study shows that prolonged sitting may be detrimental to plantar skin health. It highlights the need to further examine the effects of prolonged sitting in individuals, who may have a reduced tolerance to loading in the plantar skin and soft tissues.


Asunto(s)
Complicaciones de la Diabetes/fisiopatología , Pie Diabético/diagnóstico , Conducta Sedentaria , Piel/fisiopatología , Adulto , Índice de Masa Corporal , Diabetes Mellitus/fisiopatología , Pie Diabético/clasificación , Femenino , Voluntarios Sanos/estadística & datos numéricos , Humanos , Proteína Antagonista del Receptor de Interleucina 1/análisis , Proteína Antagonista del Receptor de Interleucina 1/sangre , Interleucina-1alfa/análisis , Interleucina-1alfa/sangre , Masculino , Persona de Mediana Edad , Presión/efectos adversos
5.
Med Eng Phys ; 78: 39-47, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32035813

RESUMEN

BACKGROUND: In the early stages of rehabilitation after primary amputation, residual limb soft tissues have not been mechanically conditioned to support load and are vulnerable to damage from prosthetic use. There is limited quantitative knowledge of skin and soft tissue response to prosthetic loading. METHODS: An in-vivo protocol was developed to establish suitable measures to assess tissue tolerance during loading representative of early prosthesis use. Ten participants without amputation one participant with trans-tibial amputation were recruited, and pressure applied to their calf in increments from 20 to 60 mmHg. Measurements were recorded at relevant skin sites including interface pressures, transcutaneous oxygen (TCPO2) and carbon dioxide (TCPCO2) tensions and inflammatory biomarkers. FINDINGS: At the maximum cuff pressure, mean interface pressures were between 66 and 74 mmHg, associated with decreased TCPO2 values. On the release of pressure, the ischaemic response was reversed. Significant upregulation (p < 0.05) in inflammatory biomarker IL-1α and its antagonist IL-1RA were observed at all sites immediately following loading. INTERPRETATION: The protocol was successful in applying representative prosthetic loads to lower limb tissues and monitoring the physiological response, both in terms of tissue ischemia and skin inflammation. Results indicated that the measurement approaches were sensitive to changes in interface conditions, offering a promising approach to monitor tissue status for people with amputation.


Asunto(s)
Pruebas Mecánicas/instrumentación , Prótesis e Implantes , Adulto , Biomarcadores/metabolismo , Fenómenos Biomecánicos , Dióxido de Carbono/metabolismo , Estudios de Cohortes , Femenino , Humanos , Masculino , Oxígeno/metabolismo , Presión , Piel/metabolismo , Soporte de Peso , Adulto Joven
6.
J Tissue Viability ; 28(4): 186-193, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31668875

RESUMEN

Pressure ulcers (PUs) represent a substantial burden to both patients and healthcare providers. Accordingly, effective prevention strategies should follow early detection of PUs. Anaerobic metabolites, such as lactate and pyruvate, are promising noninvasive biomarkers indicative of tissue ischaemia, one of the major mechanisms leading to PU development. The aim of this study was to investigate if the temporal release profile of these metabolites in sweat and sebum is sensitive to detect local tissue changes resulting from prolonged mechanical loads. The sacrum of healthy volunteers was subjected to two different loading protocols. After a baseline measurement, the left and right side of the sacrum were subjected to continuous and intermittent loading regimen, respectively, at a pressure of 100 mmHg. Biomarker samples were collected every 20 min, with a total experimental time of 140 min. Sweat was collected at 37 ∘C and 80% relative humidity, and sebum at ambient conditions, from 11 to 13 volunteers, respectively. Both samples were analysed for lactate and pyruvate concentrations using ultra-high performance supercritical fluid chromatography mass spectrometry. Prior to analysis metabolite concentrations were normalized to individual baseline levels and, in the case of sweat, additional normalization was performed to an unloaded control site to account for fatigue of sweat glands. Although substantial variability was present, the temporal release profiles of both sweat and sebum metabolites reflected the applied loading regimen with increased levels upon load application, and recovery to baseline levels following load removal. Highest relative increases were 20% and 30% for sweat lactate and pyruvate, respectively, and 41% for sebum lactate. Sebum pyruvate was not present in quantifiable amounts. There was a linear correlation between the individual responses to intermittent and continuous loading. The present study revealed that metabolite biomarkers in both sweat and sebum were sensitive to the application of mechanical loads, indicative of local ischaemia within skin and soft tissues. Similar trends in metabolic biomarkers were observed in response to intermittent and continuous loading regimens in both sweat and sebum. Metabolites represent a potential means to monitor the health of loaded skin and soft tissues informing timely interventions of PU prevention.


Asunto(s)
Anaerobiosis/fisiología , Biomarcadores/análisis , Úlcera por Presión/metabolismo , Sebo/metabolismo , Piel/metabolismo , Sudor/metabolismo , Adulto , Anciano , Biomarcadores/metabolismo , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Úlcera por Presión/fisiopatología , Piel/fisiopatología , Reino Unido , Soporte de Peso/fisiología
7.
Clin Biomech (Bristol, Avon) ; 67: 70-77, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31077978

RESUMEN

BACKGROUND: In recent years, it has become increasingly apparent that medical device-related pressure ulcers represent a significant burden to both patients and healthcare providers. Medical devices can cause damage in a variety of patients from neonates to community based adults. To date, devices have typically incorporated generic designs with stiff polymer materials, which impinge on vulnerable soft tissues. As a result, medical devices that interact with the skin and underlying soft tissues can cause significant deformations due to high interface pressures caused by strapping or body weight. METHODS: This review provides a detailed analysis of the latest bioengineering tools to assess device related skin and soft tissue damage and future perspectives on the prevention of these chronic wounds. This includes measurement at the device-skin interface, imaging deformed tissues, and the early detection of damage through biochemical and biophysical marker detection. In addition, we assess the potential of computational modelling to provide a means for device design optimisation and material selection. INTERPRETATION: Future collaboration between academics, industrialists and clinicians should provide the basis to improve medical device design and prevent the formation of these potentially life altering wounds. Ensuring clinicians report devices that cause pressure ulcers to regulatory agencies will provide the opportunity to identify and improve devices, which are not fit for purpose.


Asunto(s)
Bioingeniería/métodos , Úlcera por Presión/prevención & control , Peso Corporal , Simulación por Computador , Humanos , Polímeros/química , Presión , Úlcera por Presión/etiología , Diseño de Prótesis , Respiración Artificial/efectos adversos , Piel/patología
8.
J Tissue Viability ; 28(1): 1-6, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30638732

RESUMEN

Pressure ulcers (PUs) are a major burden to both patients, carers and the healthcare system. It is therefore important to identify patients at risk and detect pressure ulcers at an early stage of their development. The pro-inflammatory cytokine IL-1α is a promising indicator of tissue damage. The aim of this study was to compare the temporal skin response, by means of IL-1α expression, to different loading regimens and to investigate the presence of individual variability. The sacrum of eleven healthy volunteers was subjected to two different loading protocols. After a baseline measurement, the left and right side of the sacrum were subjected to continuous and intermittent loading regimen, respectively, at a pressure of 100 mmHg. Data was collected every 20 min, allowing for a total experimental time of 140 min. Sebum, collected at ambient conditions using Sebutape, was analyzed for the pro-inflammatory cytokine IL-1α. Most robust results were obtained using a baseline normalization approach on individual data. The IL-1α level significantly changed upon load application and removal (p<0.05) for both loading regimens. Highest IL-1α ratio increase, 3.7-fold, was observed for 1 h continuous loading. During the refractory periods for both loading regimen the IL-1α levels were still found to be up-regulated compared to baseline (p<0.05). The IL-1α level increased significantly for the two initial loading periods (p<0.05), but stabilized during the final loading period for both loading regimens. Large individual variability in IL-1α ratio was observed in the responses, with median values of 1.91 (range 1.49-3.08), and 2.52 (range 1.96-4.29), for intermittent and continuous loading, respectively, although the differences were not statistically significant. Cluster analysis revealed the presence of two distinct sub-populations, with either a low or high response to the applied loading regimen. The measurement after the first loading period proved to be representative for the subsequent measurements on each site. This study revealed that trends in normalized IL-1α provided an early indicator for tissue status following periods of mechanical loading and refractory unloaded conditions. Additionally, the observed individual variability in the response potentially identifies patients at risk of developing PUs.


Asunto(s)
Interleucina-1alfa/análisis , Úlcera por Presión/etiología , Piel/lesiones , Estrés Mecánico , Adulto , Anciano , Femenino , Humanos , Interleucina-1alfa/sangre , Masculino , Persona de Mediana Edad
9.
J Mech Behav Biomed Mater ; 92: 50-57, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30658240

RESUMEN

Pressure-induced deep tissue injury is a form of pressure ulcer which is difficult to detect and diagnose at an early stage, before the wound has severely progressed and becomes visible at the skin surface. At the present time, no such detection technique is available. To test the hypothesis that muscle damage biomarkers can be indicative of the development of deep tissue injury after sustained mechanical loading, an indentation test was performed for 2 h on the tibialis anterior muscle of rats. Myoglobin and troponin were analysed in blood plasma and urine over a period of 5 days. The damage as detected by the biomarkers was compared to damage as observed with T2 MRI to validate the response. We found that myoglobin and troponin levels in blood increased due to the damage. Myoglobin was also increased in urine. The amount of damage observed with MRI immediately after loading had a strong correlation with the maximal biomarker levels: troponin in blood rs = 0.94; myoglobin in blood rs = 0.75; and myoglobin in urine rs = 0.57. This study suggests that muscle damage markers measured in blood and urine could serve as early diagnosis for pressure induced deep tissue injury.


Asunto(s)
Mioglobina/metabolismo , Úlcera por Presión/metabolismo , Troponina/metabolismo , Animales , Biomarcadores/sangre , Biomarcadores/metabolismo , Biomarcadores/orina , Femenino , Imagen por Resonancia Magnética , Mioglobina/sangre , Úlcera por Presión/sangre , Úlcera por Presión/diagnóstico por imagen , Úlcera por Presión/orina , Ratas , Ratas Sprague-Dawley , Troponina/sangre , Troponina/orina
10.
Top Spinal Cord Inj Rehabil ; 24(4): 371-378, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30459500

RESUMEN

Background: Ultrasonography may have potential as an effective diagnostic tool for deep tissue injury (DTI) in tissues overlying bony prominences that are vulnerable when under sustained loading in sitting. Methods: Three cases of DTI in the fat and muscle layers overlying the ischial tuberosity of the pelvis in 3 persons with spinal cord injury (SCI) with different medical histories and abnormal tissue signs are described. Conclusion: There is a need for prospective studies using a reliable standardized ultrasonography protocol to diagnose DTI and to follow its natural history to determine its association with the development of pressure injuries.


Asunto(s)
Nalgas/diagnóstico por imagen , Úlcera por Presión/diagnóstico por imagen , Traumatismos de los Tejidos Blandos/diagnóstico por imagen , Traumatismos de la Médula Espinal/diagnóstico por imagen , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Úlcera por Presión/etiología , Traumatismos de los Tejidos Blandos/etiología , Traumatismos de la Médula Espinal/complicaciones , Ultrasonografía
11.
J Mech Behav Biomed Mater ; 86: 423-432, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30031246

RESUMEN

Skin mechanics is of importance in various fields of research when accurate predictions of the mechanical response of skin is essential. This study aims to develop a new constitutive model for human skin that is capable of describing the heterogeneous, nonlinear viscoelastic mechanical response of human skin under shear deformation. This complex mechanical response was determined by performing large amplitude oscillatory shear (LAOS) experiments on ex vivo human skin samples. It was combined with digital image correlation (DIC) on the cross-sectional area to assess heterogeneity. The skin is modeled as a one-dimensional layered structure, with every sublayer behaving as a nonlinear viscoelastic material. Heterogeneity is implemented by varying the stiffness with skin depth. Using an iterative parameter estimation method all model parameters were optimized simultaneously. The model accurately captures strain stiffening, shear thinning, softening effect and nonlinear viscous dissipation, as experimentally observed in the mechanical response to LAOS. The heterogeneous properties described by the model were in good agreement with the experimental DIC results. The presented mathematical description forms the basis for a future constitutive model definition that, by implementation in a finite element method, has the capability of describing the full 3D mechanical behavior of human skin.


Asunto(s)
Modelos Estadísticos , Resistencia al Corte , Piel , Adolescente , Adulto , Anciano , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Humanos , Persona de Mediana Edad , Dinámicas no Lineales , Adulto Joven
12.
J Tissue Viability ; 26(3): 180-188, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28602246

RESUMEN

Prolonged mechanical loading can lead to the breakdown of skin and underlying tissues which can, in turn, develop into a pressure ulcer. The benefits of pressure relief and/or redistribution to minimise risk have been well documented. Manufacturers have developed alternating air pressure mattresses (APAMs) to provide periodic relief for individuals on prolonged bed-rest. The present study describes the development of a control system, termed Pneumatic Manager which can vary the signature of an APAM, namely its pressure amplitude, cell profile and cycle period. An experimental array was designed to investigate the effects of varying these parameters, particularly with respect to its ability to maintain skin viability in a group of five healthy volunteers lying in a supine position. Transcutaneous gas (TcPO2/TcPCO2) tensions at the sacrum were monitored. In addition, pressures and microclimate parameters at the loaded support interface were also measured. In the majority of test conditions the alternating support produced sacral TcPO2 values, which either remained relatively high or fluctuated in concert with cycle period providing adequate viability. However, in 46% of cases at the extreme pressure amplitude of 100/0 mmHg, there was compromise to the skin viability at the sacrum, as reflected in depressed TcPO2 levels associated with an elevation of TcPCO2 levels above the normal range. In all cases, both the humidity and temperature levels increased during the test period. It is interesting to note that interface pressures at the sacrum rarely exceeded 60 mmHg. Although such studies need to be extended to involve bed-bound individuals, the results provide a design template for the optimum pressure signatures of APAM systems to ensure maintenance of skin viability during pronged loading.


Asunto(s)
Lechos/normas , Presión/efectos adversos , Transductores de Presión/estadística & datos numéricos , Pesos y Medidas/instrumentación , Adulto , Diseño de Equipo/normas , Femenino , Humanos , Masculino , Úlcera por Presión/fisiopatología , Úlcera por Presión/prevención & control , Región Sacrococcígea/irrigación sanguínea , Región Sacrococcígea/fisiopatología
13.
Inflamm Res ; 66(1): 49-58, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27658702

RESUMEN

OBJECTIVE AND DESIGN: Oxygen tension and biomechanical signals are factors that regulate inflammatory mechanisms in chondrocytes. We examined whether low oxygen tension influenced the cells response to TNFα and dynamic compression. MATERIALS AND METHODS: Chondrocyte/agarose constructs were treated with varying concentrations of TNFα (0.1-100 ng/ml) and cultured at 5 and 21 % oxygen tension for 48 h. In separate experiments, constructs were subjected to dynamic compression (15 %) and treated with TNFα (10 ng/ml) and/or L-NIO (1 mM) at 5 and 21 % oxygen tension using an ex vivo bioreactor for 48 h. Markers for catabolic activity (NO, PGE2) and tissue remodelling (GAG, MMPs) were quantified by biochemical assay. ADAMTS-5 and MMP-13 expression were examined by real-time qPCR. 2-way ANOVA and a post hoc Bonferroni-corrected t test were used to analyse data. RESULTS: TNFα dose-dependently increased NO, PGE2 and MMP activity (all p < 0.001) and induced MMP-13 (p < 0.05) and ADAMTS-5 gene expression (pp < 0.01) with values greater at 5 % oxygen tension than 21 %. The induction of catabolic mediators by TNFα was reduced by dynamic compression and/or L-NIO (all p < 0.001), with a greater inhibition observed at 5% than 21 %. The stimulation of GAG synthesis by dynamic compression was greater at 21 % than 5 % oxygen tension and this response was reduced with TNFα or reversed with L-NIO. CONCLUSIONS: The present findings revealed that TNFα increased production of NO, PGE2 and MMP activity at 5 % oxygen tension. The effects induced by TNFα were reduced by dynamic compression and/or the NOS inhibitor, linking both types of stimuli to reparative activities. Future therapeutics should develop oxygen-sensitive antagonists which are directed to interfering with the TNFα-induced pathways.


Asunto(s)
Condrocitos/efectos de los fármacos , Oxígeno/fisiología , Factor de Necrosis Tumoral alfa/farmacología , Proteína ADAMTS5/genética , Animales , Bovinos , Células Cultivadas , Condrocitos/metabolismo , Condrocitos/fisiología , Dinoprostona/metabolismo , Glicosaminoglicanos/metabolismo , Metaloproteinasa 13 de la Matriz/genética , Óxido Nítrico/metabolismo , Estrés Mecánico
14.
Clin Biomech (Bristol, Avon) ; 40: 27-32, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27794259

RESUMEN

BACKGROUND: Individuals with impaired mobility can spend prolonged periods on support surfaces, increasing their risk of developing pressure ulcers. Manufacturers have developed mattresses to maximise contact area. The present study evaluated both the biomechanical and physiological responses to lying postures on a Fluid Immersion Simulation mattress. METHODS: Seventeen healthy participants were recruited to evaluate the mattress during three prescribed settings of immersion (high, medium and low). Parameters reflecting biomechanical and physiological responses, and the microclimate were monitored during three postures (supine, lateral and high-sitting) over a 90minute test session. Transcutaneous oxygen and carbon dioxide gas responses were categorised according to three criteria and data were compared between each condition. FINDINGS: Results indicated that interface pressures remained consistent, with peak sacral values ranging from 21 to 27mmHg across all immersion settings and postures. The majority of participants (82%) exhibited minimal changes in gas tensions at the sacrum during all test conditions. By contrast, three participants exhibited decreased oxygen with increased carbon dioxide tensions for all three immersion settings. Supine and high sitting sacral microclimate values ranged between 30.1-30.6°C and 42.3-44.5% for temperature and relative humidity respectively. During lateral tilt there was a reduction of 1.7-2.5°C and 3.3-5.3% in these values. The majority of participants reported high comfort scores, although a few experienced bottoming out during the high-sitting posture at the high immersion setting. INTERPRETATION: Fluid Immersion Simulation provides an intelligent approach to increase the support area. Further research is required to provide evidence based guidance on the use of personalised support surfaces.


Asunto(s)
Lechos , Úlcera por Presión/prevención & control , Presión/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Monitoreo de Gas Sanguíneo Transcutáneo , Dióxido de Carbono/sangre , Estudios Cruzados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Postura/fisiología , Sacro/fisiología , Temperatura , Adulto Joven
15.
Med Eng Phys ; 38(9): 895-903, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27245749

RESUMEN

It is proposed that direct mechanical loading can impair dermal lymphatic function, contributing to the causal pathway of pressure ulcers. The present study aims to investigate the effects of loading on human dermal lymphatic vessels. Ten participants were recruited with ages ranging from 24 to 61 years. Participants had intradermal Indocyanine Green injections administrated between left finger digits. Fluorescence was imaged for 5min sequences with an infra-red camera prior to lymph vessel loading, immediately after axial loading (60mmHg) and following a recovery period. Image processing was employed to defined transient lymph packets and compare lymph function between each test phase. The results revealed that between 1-8 transient events (median=4) occurred at baseline, with a median velocity of 8.1mm/sec (range 4.1-20.1mm/sec). Immediately post-loading, there was a significant (p<0.05) reduction in velocity (median=6.4, range 2.2-13.5mm/sec), although the number of transient lymph packages varied between participants. During the recovery period the number (range 1-7) and velocity (recovery median=9.6mm/sec) of transient packets were largely restored to basal values. The present study revealed that some individuals present with impaired dermal lymphatic function immediately after uniaxial mechanical loading. More research is needed to investigate the effects of pressure and shear on lymphatic vessel patency.


Asunto(s)
Dermis/irrigación sanguínea , Vasos Linfáticos/fisiología , Vasoconstricción , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Vasos Linfáticos/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Imagen Óptica , Soporte de Peso , Adulto Joven
16.
Clin Biomech (Bristol, Avon) ; 35: 7-13, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27111878

RESUMEN

BACKGROUND: Repositioning of individuals with reduced mobility and at risk of pressure ulcers is an essential preventive step. Manual or automatic lateral tilting is a way of doing this and the international guidelines propose a 30° to 40° side lying position. The goal of the present study was to determine the internal strains in individuals lying in a supine position and during tilting. METHODS: Based on magnetic resonance imaging (MRI) of the sacral area of human volunteers, subject specific finite element models were developed. By comparing calculated contours of the skin, fat and muscle with MRI measurements on a flat surface the models were validated. A parameter study was performed to assess the sensitivity of the model for changes in material properties. Simulations were performed at tilting angles of volunteers between 0° and 45°. FINDINGS: Subjects in a supine position or tilted have the highest strains in the muscle and fat. Tilting does affect the strain distribution, taking away the highest peak strains. There seems to exist an optimal tilting angle between 20° and 30°, which may vary depending on factors such as BMI of the subject and is in the current paper investigated only for the sacrum. INTERPRETATION: The study shows that tilting indeed has a significant, positive influence on internal strains, which is important for the prevention of deep tissue injury. Additional studies are needed to draw conclusions about the greater trochanter area and the tissues around the shoulder.


Asunto(s)
Posicionamiento del Paciente/métodos , Úlcera por Presión/prevención & control , Región Sacrococcígea , Tejido Adiposo/fisiología , Adulto , Femenino , Análisis de Elementos Finitos , Humanos , Imagen por Resonancia Magnética , Masculino , Músculo Esquelético/fisiología , Fenómenos Fisiológicos de la Piel
17.
Med Eng Phys ; 38(7): 695-700, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27118308

RESUMEN

A sensor system for measurement of pressure and shear at the lower limb residuum/socket interface is described. The system comprises of a flexible sensor unit and a data acquisition unit with wireless data transmission capability. Static and dynamic performance of the sensor system was characterised using a mechanical test machine. The static calibration results suggest that the developed sensor system presents high linearity (linearity error ≤ 3.8%) and resolution (0.9 kPa for pressure and 0.2 kPa for shear). Dynamic characterisation of the sensor system shows hysteresis error of approximately 15% for pressure and 8% for shear. Subsequently, a pilot amputee walking test was conducted. Three sensors were placed at the residuum/socket interface of a knee disarticulation amputee and simultaneous measurements were obtained during pilot amputee walking test. The pressure and shear peak values as well as their temporal profiles are presented and discussed. In particular, peak pressure and shear of approximately 58 kPa and 27 kPa, respectively, were recorded. Their temporal profiles also provide dynamic coupling information at this critical residuum/socket interface. These preliminary amputee test results suggest strong potential of the developed sensor system for exploitation as an assistive technology to facilitate socket design, socket fit and effective monitoring of lower limb residuum health.


Asunto(s)
Muñones de Amputación , Extremidad Inferior , Presión , Estrés Mecánico , Miembros Artificiales , Calibración , Humanos , Diseño de Prótesis
18.
Biochem Biophys Res Commun ; 465(4): 784-9, 2015 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-26307537

RESUMEN

Signals induced by mechanical loading and C-type natriuretic peptide (CNP) represent chondroprotective routes that may potentially prevent osteoarthritis (OA). We examined whether CNP will reduce hyaluronan production and export via members of the multidrug resistance protein (MRP) and diminish pro-inflammatory effects in human chondrocytes. The presence of interleukin-1ß (IL-1ß) increased HA production and export via MRP5 that was reduced with CNP and/or loading. Treatment with IL-1ß conditioned medium increased production of catabolic mediators and the response was reduced with the hyaluronan inhibitor, Pep-1. The induction of pro-inflammatory cytokines by the conditioned medium was reduced by CNP and/or Pep-1, αCD44 or αTLR4 in a cytokine-dependent manner, suggesting that the CNP pathway is protective and should be exploited further.


Asunto(s)
Condrocitos/metabolismo , Péptido Natriurético Tipo-C/metabolismo , Células Cultivadas , Medios de Cultivo Condicionados , GMP Cíclico/biosíntesis , Citocinas/biosíntesis , Regulación de la Expresión Génica , Homeostasis , Humanos , Ácido Hialurónico/antagonistas & inhibidores , Ácido Hialurónico/biosíntesis , Mediadores de Inflamación/metabolismo , Interleucina-1beta/metabolismo , Modelos Biológicos , Proteína 2 Asociada a Resistencia a Múltiples Medicamentos , Proteínas Asociadas a Resistencia a Múltiples Medicamentos/genética , Proteínas Asociadas a Resistencia a Múltiples Medicamentos/metabolismo , Péptidos/metabolismo , Transducción de Señal
19.
Med Eng Phys ; 37(1): 132-7, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25455164

RESUMEN

A novel capacitance-based sensor designed for monitoring mechanical stresses at the stump-socket interface of lower-limb amputees is described. It provides practical means of measuring pressure and shear stresses simultaneously. In particular, it comprises of a flexible frame (20 mm × 20 mm), with thickness of 4mm. By employing rapid prototyping technology in its fabrication, it offers a low-cost and versatile solution, with capability of adopting bespoke shapes of lower-limb residua. The sensor was first analysed using finite element analysis (FEA) and then evaluated using lab-based electromechanical tests. The results validate that the sensor is capable of monitoring both pressure and shear at stresses up to 350 kPa and 80 kPa, respectively. A post-signal processing model is developed to induce pressure and shear stresses, respectively. The effective separation of pressure and shear signals can be potentially advantageous for sensor calibration in clinical applications. The sensor also demonstrates high linearity (approx. 5-8%) and high pressure (approx. 1.3 kPa) and shear (approx. 0.6 kPa) stress resolution performance. Accordingly, the sensor offers the potential for exploitation as an assistive tool to both evaluate prosthetic socket fitting in clinical settings and alert amputees in home settings of excessive loading at the stump-socket interface, effectively preventing stump tissue breakdown at an early stage.


Asunto(s)
Miembros Artificiales , Capacidad Eléctrica , Presión , Impresión Tridimensional , Estrés Mecánico , Muñones de Amputación/fisiopatología , Elastómeros , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Pierna , Úlcera de la Pierna/prevención & control , Modelos Lineales , Docilidad , Procesamiento de Señales Asistido por Computador
20.
Placenta ; 35(12): 1057-64, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25280972

RESUMEN

INTRODUCTION: There is evidence that premature rupture of the fetal membrane at term/preterm is a result of stretch and tissue weakening due to enhanced prostaglandin E2 (PGE2) production. However, the effect of tensile strain on inflammatory mediators and the stretch sensitive protein connexin-43 (Cx43) has not been examined. We determined whether the inflammatory environment influenced tissue composition and response of the tissue to tensile strain. METHODS: Human amniotic membranes isolated from the cervix (CAM) or placenta regions (PAM) were examined by second harmonic generation to identify collagen orientation and subjected to tensile testing to failure. In separate experiments, specimens were subjected to cyclic tensile strain (2%, 1 Hz) for 24 h. Specimens were examined for Cx43 by immunofluorescence confocal microscopy and expression of COX-2 and Cx43 by RT-qPCR. PGE2, collagen, elastin and glycosaminoglycan (GAG) levels were analysed by biochemical assay. RESULTS: Values for tensile strength were significantly higher in PAM than CAM with mechanical parameters dependent on collagen orientation. Gene expression for Cx43 and COX-2 was enhanced by tensile strain leading to increased PGE2 release and GAG levels in PAM and CAM when compared to unstrained controls. In contrast, collagen and elastin content was reduced by tensile strain in PAM and CAM. DISCUSSION: Fibre orientation has a significant effect on amniotic strength. Tensile strain increased Cx43/COX-2 expression and PGE2 release resulting in tissue softening mediated by enhanced GAG levels and a reduction in collagen/elastin content. CONCLUSION: A combination of inflammatory and mechanical factors may disrupt amniotic membrane biomechanics and matrix composition.


Asunto(s)
Amnios/metabolismo , Conexina 43/metabolismo , Ciclooxigenasa 2/metabolismo , Dinoprostona/metabolismo , Rotura Prematura de Membranas Fetales/metabolismo , Resistencia a la Tracción/fisiología , Conexina 43/genética , Ciclooxigenasa 2/genética , Femenino , Humanos , Embarazo , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA