Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 50
1.
Article En | MEDLINE | ID: mdl-38692478

OBJECTIVES: Traditional criterion for intervention on an asymptomatic ascending aortic aneurysm has been a maximal aortic diameter of 5.5 cm or more. The 2022 American College of Cardiology/American Heart Association aortic guidelines adopted cross-sectional aortic area/height ratio, aortic size index, and aortic height index as alternate parameters for surgical intervention. The objective of this study was to evaluate the impact of using these newer indices on patient eligibility for surgical intervention in a prospective, multicenter cohort with moderate-sized ascending aortic aneurysms between 5.0 and 5.4 cm. METHODS: Patients enrolled from 2018 to 2023 in the randomization or registry arms of the multicenter trial, Treatment In Thoracic Aortic aNeurysm: Surgery versus Surveillance, were included in the study. Clinical data were captured prospectively in an online database. Imaging data were derived from a core computed laboratory. RESULTS: Among the 329 included patients, 20% were female. Mean age was 65.0 ± 11.6 years, and mean maximal aortic diameter was 50.8 ± 3.9 mm. In the one-third of all patients (n = 109) who met any 1 of the 3 criteria (ie, aortic size index ≥3.08 cm/m2, aortic height index ≥3.21 cm/m, or cross-sectional aortic area/height ≥ 10 cm2/m), their mean maximal aortic diameter was 52.5 ± 0.52 mm. Alternate criteria were most commonly met in women compared with men: 20% versus 2% for aortic size index (P < .001), 39% versus 5% for aortic height index (P < .001), and 39% versus 21% for cross-sectional aortic area/height (P = .002), respectively. CONCLUSIONS: One-third of patients in Treatment In Thoracic Aortic aNeurysm: Surgery versus Surveillance would meet criteria for surgical intervention based on novel parameters versus the classic definition of diameter 5.5 cm or more. Surgical thresholds for aortic size index, aortic height index, or cross-sectional aortic area/height ratio are more likely to be met in female patients compared with male patients.

2.
Heart ; 110(5): 331-336, 2024 Feb 12.
Article En | MEDLINE | ID: mdl-37648437

OBJECTIVE: Aortic dissection and aortic aneurysm rupture are aortic emergencies and their clinical outcomes have improved over the past two decades; however, whether this has translated into lower mortality across countries remains an open question. The purpose of this study was to compare mortality trends from aortic dissection and rupture between the UK, Japan, the USA and Canada. METHODS: We analysed the WHO mortality database to determine trends in mortality from aortic dissection and rupture in four countries from 2000 to 2019. Age-standardised mortality rates per 100 000 persons were calculated, and annual percentage change was estimated using joinpoint regression. RESULTS: Age-standardised mortality rates per 100 000 persons from aortic dissection and rupture in 2019 were 1.04 and 1.80 in the UK, 2.66 and 1.16 in Japan, 0.76 and 0.52 in the USA, and 0.67 and 0.81 in Canada, respectively. There was significantly decreasing trends in age-standardised mortality from aortic rupture in all four countries and decreasing trends in age-standardised mortality from aortic dissection in the UK over the study period. There was significantly increasing trends in mortality from aortic dissection in Japan over the study period. Joinpoint regression identified significant changes in the aortic dissection trends from decreasing to increasing in the USA from 2010 and Canada from 2012. In sensitivity analyses stratified by sex, similar trends were observed. CONCLUSIONS: Trends in mortality from aortic rupture are decreasing; however, mortality from aortic dissection is increasing in Japan, the USA and Canada. Further study to explain these trends is warranted.


Aortic Dissection , Aortic Rupture , Humans , Japan/epidemiology , Canada/epidemiology , United Kingdom/epidemiology
7.
JACC Case Rep ; 15: 101858, 2023 Jun 07.
Article En | MEDLINE | ID: mdl-37283827

Diffuse large B-cell lymphoma (DLBCL) is an aggressive lymphoma that is fatal if left untreated. Few cases have been reported of involvement of the aorta. Here we present a case of DLBCL that was diagnosed by periaortic computed tomography-guided biopsy. (Level of Difficulty: Intermediate.).

9.
Circ Cardiovasc Interv ; 16(3): e012623, 2023 03.
Article En | MEDLINE | ID: mdl-36943929

BACKGROUND: Transcatheter aortic valve replacement is approved for treatment of patients with severe aortic stenosis across the spectrum of risk. While considering broader indications for use, transcatheter aortic valve replacement in large native annuli has become increasingly important. METHODS: Patients with tricuspid aortic stenosis undergoing transcatheter aortic valve replacement using the Evolut R or Evolut PRO+ 34 mm valves (Medtronic, Minneapolis, MN) in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry between October 2016 and September 2020 were stratified according to in range (>12%) device oversizing and below range (0%-12%) device oversizing. Patients undergoing valve-in-valve procedures, having a baseline annulus size <26 or ≥34 mm, or without computed tomography angiography measured annulus size were excluded. Percentage of oversizing was calculated as [(valve diameter-annulus diameter)×100/annulus diameter]. RESULTS: Transcatheter aortic valve replacement in patients with large annuli was performed in 8017 patients with a mean (±SD) age 79.3±7.9 years and 94% were male. Below range (n=1096) was less common than in range oversizing (n=6921). At 1-year follow-up, mortality (19.6% versus 14.9%; P=0.001), aortic valve reintervention (2.1% versus 0.6%; P<0.001) and valve-related readmission rates (3.2% versus 2.0%; P=0.014) were higher in the below range device oversizing group versus in range group respectively. In a multivariable Cox proportional hazards regression model, when controlling for clinically relevant covariates, below range device oversizing was associated with higher 1-year all-cause mortality (HR, 1.28 [CI, 1.07-1.51]; P=0.005). CONCLUSIONS: Results from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry in patients with large annuli valves using 34mm Evolut R/PRO+ valves suggest that in range (>12%) device oversizing delivered better clinical outcomes than implantation with below range (0%-12%) device oversizing.


Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Aged, 80 and over , Female , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Registries , Prosthesis Design
10.
J Invasive Cardiol ; 35(2): E108-E109, 2023 02.
Article En | MEDLINE | ID: mdl-36735874

The Cor-Knot surgical tying device (LSI Solutions) is an automated suture fastener with a titanium-crimpable sleeve that facilitates a fast and secure knot. The device is an alternative to hand tying, minimizing operation time, and its increasing use is anticipated for minimally invasive cardiac surgeries or in patients with small surgical anatomy. As its use expands, the likelihood of encountering this knotting device during structural interventions may increase. In this case, during the TAVR procedure, the coplanar angle estimated from preoperative computed tomography scan was easily adjusted referencing the line of Cor-Knot in her aortic annulus without administrating contrast despite poor radiodensity from the Trifecta valve. In the coplanar view, the TAVR valve depth was well appreciated in reference to the Cor-Knot line and the TAVR valve was deployed under controlled pacing without contrast use. We achieved mean aortic pressure gradient of 9 mm Hg without paravalvular leakage or conduction abnormalities. She was discharged to home the next day without renal injury.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Female , Humans , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Risk Factors
11.
Europace ; 25(4): 1441-1450, 2023 04 15.
Article En | MEDLINE | ID: mdl-36794441

AIMS: Patients who undergo permanent pacemaker (PPM) implantation after transcatheter aortic valve replacement (TAVR) have a worse outcome. The aim of this study was to identify risk factors of worse outcomes in patients with post-TAVR PPM implantation. METHODS AND RESULTS: This is a single-centre, retrospective study of consecutive patients who underwent post-TAVR PPM implantation from 11 March 2011 to 9 November 2019. Clinical outcomes were evaluated by landmark analysis with cut-off at 1 year after the PPM implantation. Of the 1389 patients underwent TAVR during the study duration and a total of 110 patients were included in the final analysis. Right ventricular pacing burden (RVPB) ≥ 30% at 1 year was associated with a higher likelihood of heart failure (HF) readmission [adjusted hazard ratio (aHR): 6.333; 95% confidence interval [CI]: 1.417-28.311; P = 0.016] and composite endpoint of overall death and/or HF (aHR: 2.453; 95% CI: 1.040-5.786; P = 0.040). The RVPB ≥30% at 1 year was associated with higher atrial fibrillation burden (24.1 ± 40.6% vs. 1.2 ± 5.3%; P = 0.013) and a decrease in left ventricular ejection fraction (-5.0 ± 9.8% vs. + 1.1 ± 7.9%; P = 0.005). The predicting factors of the RVPB ≥30% at 1 year were the presence of RVPB ≥40% at 1 month and the valve implantation depth measured from non-coronary cusp ≥4.0 mm (aHR: 57.808; 95% CI: 12.489-267.584; P < 0.001 and aHR: 6.817; 95% CI: 1.829-25.402; P = 0.004). CONCLUSIONS: The RVPB ≥30% at 1 year was associated with worse outcomes. Clinical benefit of minimal RV pacing algorithms and biventricular pacing needs to be investigated.


Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Cardiac Pacing, Artificial/adverse effects , Retrospective Studies , Stroke Volume , Treatment Outcome , Aortic Valve Stenosis/surgery , Ventricular Function, Left , Risk Factors , Aortic Valve/surgery
12.
Rev. Fund. Educ. Méd. (Ed. impr.) ; 26(1): 29-36, febrero 2023. tab
Article Es | IBECS | ID: ibc-218694

Introducción: La medicina narrativa en los últimos años se considera una herramienta útil en los profesionales de salud para el desarrollo del humanismo y su relación con los usuarios; no obstante, en las facultades se continúa investigando su uso como herramienta en educación médica en carreras pertenecientes a las ciencias de la salud.Sujetos y métodos.Comparación de las percepciones entre dos grupos de estudiantes de fisioterapia con y sin conocimientos previos en medicina narrativa posterior a una actividad académica.Resultados.Se encontraron diferencias estadísticamente significativas en la percepción del desarrollo de habilidades personales, sociales, autopercepción, y método de enseñanza-aprendizaje y de evaluación.Conclusión.La medicina narrativa se percibe de forma positiva en ambos grupos; no obstante, el objetivo de su aplicación debe considerar el factor de formación previa para lograr el desarrollo específico que se busca con la metodología. (AU)


Introduction: Narrative medicine in recent years has been considered a useful tool for health professionals for the development of humanism and its relationship with users, however, in the faculties its use continues to be investigated as a tool in medical education in careers related to the health sciences.Subjects and method.Comparison of perceptions between two groups of physiotherapy students with and without previous knowledge in narrative medicine after an academic activity.Results.Statistically, significant differences were found in the perception of the development of personal and social skills, self-perception, teaching method-learning and evaluation.Conclusion.Narrative medicine is perceived positively in both groups, however, the objective of its application must consider the prior training factor to achieve the specific development sought with the methodology. (AU)


Humans , Bioethics , Education, Medical , Physical Therapy Specialty , Humanism , Narrative Medicine
14.
Ann Thorac Surg ; 115(1): 72-78, 2023 01.
Article En | MEDLINE | ID: mdl-35283098

BACKGROUND: We investigated outcomes of coronary artery bypass grafting (CABG) with endoscopic vein harvest (EVH) vs open vein harvest (OVH) within the Evaluation of XIENCE Versus CABG (EXCEL) trial. METHODS: All patients in EXCEL randomized to CABG were included in this study. For this analysis, the primary end points were ischemia-driven revascularization (IDR) and graft stenosis or occlusion at 5 years. Additional end points were as follows: a composite of death from any cause, stroke, or myocardial infarction; bleeding; blood product transfusion; major arrhythmia; and infection requiring antibiotics. Event rates were based on Kaplan-Meier estimates in time-to-first-event analyses. RESULTS: Of the 957 patients randomized to CABG, 686 (71.7%) received at least 1 venous graft with 257 (37.5%) patients in the EVH group and 429 (62.5%) patients in the OVH group. At 5 years, IDR was higher (11.5% vs 6.7%; P = .047) in the EVH group. At 5 years, rates of graft stenosis or occlusion (9.7% vs 5.4%; P = .054) and the primary end point (17.4% vs 20.9%; P = .27) were similar. In-hospital bleeding (11.3% vs 13.8%; P = .35), in-hospital blood product transfusion (12.8% vs 13.1%; P = .94), and infection requiring antibiotics within 1 month (13.6% vs 16.8%; P = .27) were similar between EVH and OVH patients. Major arrhythmia in the hospital (19.8% vs 13.5%; P = .03) and within 1 month (21.8% vs 15.4%; P = .03) was higher in EVH patients. CONCLUSIONS: IDR at 5 years was higher in the EVH group. EVH and OVH patients had similar rates of graft stenosis or occlusion and the composite of death, stroke, or myocardial infarction at 5 years.


Coronary Artery Disease , Drug-Eluting Stents , Myocardial Infarction , Stroke , Humans , Coronary Artery Disease/surgery , Constriction, Pathologic , Saphenous Vein/transplantation , Endoscopy , Treatment Outcome
15.
Am J Cardiol ; 189: 1-10, 2023 02 15.
Article En | MEDLINE | ID: mdl-36481373

Permanent pacemaker implantation (PPMI) reduction and optimal management of newly acquired conduction disturbances after transcatheter aortic valve implantation (TAVI) are crucial. We sought to evaluate the relation between transcatheter heart valve (THV) implantation depth and baseline and newly acquired conduction disturbances on PPMI after TAVI. This study included 1,026 consecutive patients with severe symptomatic aortic stenosis (mean age 79.7 ± 8.4 years; 47.4% female) who underwent TAVI with the newer-generation self-expanding THVs Primary outcomes were early and late PPMI defined as the need for PPMI during the index admission and between discharge and 30 days, respectively. Early and late PPMI was required for 115 (11.2%) and 21 patients (2.0%), respectively. Early PPMI rates decreased from 26.7% in 2015 and 2016 to 5.7% in 2021, and so did the mean THV depth from 4.4 ± 2.4 mm to 1.8 ± 1.6 mm. Receiver operator characteristics curve analyses showed THV depth had significant discriminatory value for early and late PPMI with cutoff values of 3.0 and 2.2 mm, respectively. Rates of early and late PPMI were significantly lower for patients with shallower compared with deeper implantations (5.1% vs 22.6% and 0.4% vs 4.1%, p <0.001 for both, respectively). Furthermore, rates of early PPMI were lower with shallower implantations in patients with new left bundle branch block after TAVI (2.4% vs 15.9%; p <0.001) and those with baseline right bundle branch block (7.5% vs 29.6%; p = 0.017). Lower rates of PPMI with shallower THV implantation were consistently observed, including in patients with baseline and newly acquired conduction disturbances. Our findings might help optimize the management of a temporary pacemaker after TAVI.


Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Treatment Outcome , Bundle-Branch Block/therapy
16.
Am J Prev Cardiol ; 12: 100378, 2022 Dec.
Article En | MEDLINE | ID: mdl-36106308

Objective: Low-dose cardiac-gated chest CTs allow for simultaneous evaluation of coronary artery calcification and aortic size. We sought to evaluate the prevalence of thoracic aortic dilation (TAD) and thoracic aortic aneurysm (TAA) in a large cohort of patients undergoing coronary artery calcium (CAC) screening. Methods: We reviewed all patients from a large, prospective no-charge CAC screening program (CLARIFY, Clinicaltrials.gov NCT04075162) for whom measurements of the ascending aorta were available. TAD was defined as an ascending aortic diameter ≥4.0cm, while TAA was defined as ascending aortic diameter ≥ 4.5cm. We explored associations between patient characteristics, CAC, and the prevalence of TAD/TAA. Results: A total of 36,356 patients enrolled in the CLARIFY program underwent analysis for TAD/TAA. 3,130 patients (8.6%) had TAD and 237 (0.7%) had TAA. Patients with TAA were older (63±8 vs 59±10 years, p < 0.001), more likely to be male (87% vs 49%, p < 0.001), have higher BMI (32 vs 30 kg/m2, p < 0.001), and 10-year atherosclerotic cardiovascular disease estimated risk (18% vs 12%, p < 0.001). Similar differences were observed for individuals with TAD compared to individuals without TAD with respect to age (63 vs 59 years, p < 0.001), percent male (76% vs 46%, p < 0.001), BMI (32 vs 30 kg/m2, p < 0.001), and 10-year predicted risk (17% vs 11%, p < 0.001). CAC score was associated with prevalence of TAD (4.9% in those with CAC 0 to 16.5% in those with CAC≥400) and TAA (0.3% in those with CAC of 0 to 1.5% in those with CAC ≥400). Conclusion: In this large, prospective study of patients undergoing no-charge CAC screening, 8.6% had TAD (≥4.0cm) and 0.7% had TAA (≥4.5cm). Our results highlight a high yield of TAD/TAA diagnosis in this targeted cohort with cardiovascular risk factors and supports the role of no-charge CAC as a population-level strategy.

...