Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
Echocardiography ; 41(3): e15785, 2024 Mar.
Article En | MEDLINE | ID: mdl-38527004

BACKGROUND: Trans-catheter mitral valve replacement (TMVR) procedures had emerged as an alternative solution for patients who are at high risk for mitral valve surgery. Although cardiac computed tomography (CT) remains the standard method for procedural planning, there is no full agreement on the best systolic phase for quantitation of the neoLVOT. Furthermore, a new three-dimensional trans-esophageal echocardiography (3DTEE) based software was developed to serve as filter and or an alternative for patients who cannot have CT due to any contraindication. AIM: To determine the systolic phase of the cardiac cycle that shows the narrowest NeoLVOT area in order to standardize the way of using these software and then to validate the 3DTEE-based software against the CT-based one as a gold standard, in mitral valve annulus (MA) and NeoLVOT assessment. METHODS: A single center, observational, retrospective study. Initially, a sample of 20 patients (age 62 ± 4 years, 70% men) had CT-based analysis at mid-diastole (80%), early-systole (10%), mid-systole (20%), late-systole (30%-40%), in order to detect the best systolic phase at which the neoLVOT area is the narrowest after TMVR. Then, the end systolic phase was standardized for the analysis of 49 patients (age 57 ± 6 years, 60% men), using both the commercially available CT-based software and the newly available 3DTEE-based software (3mensio Structural Heart, Pie Medical Imaging, The Netherlands). The 3DTEE derived parameters were compared with the gold standard CT-based measurements. RESULTS: The neoLVOT area was significantly narrower at end-systole (224 ± 62 mm2), compared to early-systole (299 ± 70 mm2) and mid-systole (261 ± 75 mm2), (p = .005). Excellent correlation was found between 3DTEE and CT measurements for MA AP diameter (r = .96), IC diameter (r = .92), MA area (r = .96), MA perimeter (r = .94) and NeoLVOT area (r = .96), (all p-values < .0001). Virtual valve sizing was based on annulus measurement and was identical between CT and 3DTEE. Interobserver and intraobserver agreements were excellent for all the measurements with ICCs > .80. CONCLUSIONS: End-systole is the phase that shows the narrowest neoLVOT and hence should be the standard phase used during the analysis. The 3DTEE based analysis using this new software is reliable compared to the CT-based analysis and can be serve as an alternative analysis tool in patients who cannot have CT for any clinical contraindication or as a screening test and/or filter for all patients before proceeding to a detailed CT scan.


Echocardiography, Three-Dimensional , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged , Female , Humans , Male , Middle Aged , Catheters , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Valve Prosthesis Implantation/methods , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Reference Standards , Reproducibility of Results , Retrospective Studies
2.
Egypt Heart J ; 73(1): 67, 2021 Jul 20.
Article En | MEDLINE | ID: mdl-34283346

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a well-established and standard therapy for patients with symptomatic severe aortic stenosis at moderate or high risk for surgical aortic valve replacement. Recently, it has proven non-inferior in patients with low surgical risk. However, due to its high cost, the availability of TAVI is variable worldwide. Our aim was to assess the demographic and clinical characteristics and short-term and long-term outcome of those patients. A medical registry is believed to be an excellent tool to perform a field analysis of patients' course, documenting short, intermediate, and long-term outcomes. This is the first registry for patients who underwent TAVI in Egypt. RESULTS: Ninety-six patients were included in the study; some were retrospective, and the majority were prospective from 5 different cardiac centers from August 2012 till December 2017. The mean age of patients was 77 years SD ± 7.29; females were 52% of the patients and most of the patients were overweight (BMI 30.74, SD ± 6.83). Sixty-three percent of the patients were frail with Katz index ≤ 5. 3.5% had atrial fibrillation (AF) at presentation. General anesthesia was conducted in only 59.37% of the patients. Transfemoral access was the prevailing route of implantation (90%). The median hospital stay was 4 days. In-hospital and 30 days mortality was only 4.16%. CONCLUSION: TAVI outcome in Egypt appeared to be very promising with in-hospital complication, and mortality rates being comparable to international registries (4.16% vs. 4.0% in TVT registry) denoting the procedure as safe and beneficial. Establishing a national registry is critical to highlighting strength and weaknesses as well as identifying key areas for improvements.

...