1.
Life Sci ; 350: 122743, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38806071

RESUMEN

Exosomes are crucial for the growth and spread of glioblastomas, an aggressive form of brain cancer. These tiny vesicles play a crucial role in the activation of signaling pathways and intercellular communication. They can also transfer a variety of biomolecules such as proteins, lipids and nucleic acids from donor to recipient cells. Exosomes can influence the immune response by regulating the activity of immune cells, and they are crucial for the growth and metastasis of glioblastoma cells. In addition, exosomes contribute to drug resistance during treatment, which is a major obstacle in the treatment of glioblastoma. By studying them, the diagnosis and prognosis of glioblastoma can be improved. Due to their high biocompatibility and lack of toxicity, they have become an attractive option for drug delivery. The development of exosomes as carriers of specific therapeutic agents could overcome some of the obstacles to effective treatment of glioblastoma. In this review, we address the potential of exosomes for the treatment of glioblastoma and show how they can be modified for this purpose.


Asunto(s)
Neoplasias Encefálicas , Exosomas , Glioblastoma , Exosomas/metabolismo , Glioblastoma/patología , Glioblastoma/terapia , Glioblastoma/tratamiento farmacológico , Glioblastoma/metabolismo , Glioblastoma/diagnóstico , Humanos , Neoplasias Encefálicas/terapia , Neoplasias Encefálicas/tratamiento farmacológico , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/diagnóstico , Progresión de la Enfermedad , Animales , Metástasis de la Neoplasia , Sistemas de Liberación de Medicamentos/métodos , Comunicación Celular
2.
BMC Health Serv Res ; 23(1): 540, 2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-37226157

RESUMEN

PURPOSE: There is scientific evidence that ionizing radiation (IR) can be responsible for various health hazards that are one of the concerns in occupational exposure. This study was performed to evaluate DNA damage and antioxidant status in hospital workers who are occupationally exposed to low doses of IR. MATERIALS AND METHODS: In this study, twenty occupationally exposed to low doses of IR (CT and angiography) comprising with control groups which matched them. In order to investigate the effects of chronic irradiation of radiation workers, Micronuclei (MN) frequency and the antioxidant activity of Superoxide Dismutase (SOD), Catalase (CAT) and Total Antioxidant Capacity (TAC) were measured. Then, to check adaptation against high challenge dose, the samples (in all groups) were irradiated in vitro and MN frequency was compared. Finally, to investigated the effect of the high dose after the acute and chronic low dose of ionizing radiation, MN frequency was compared in two groups (the control group that was to in-vitro irradiated (acute low dose + high dose) and radiation workers (chronic low dose + high dose)). RESULTS: MN frequency in the occupationally exposed group (n = 30) increased significantly when compared to the control group (p-value < 0.0001). However, chronic irradiation of radiation workers could not lead to an adaptive Sresponse, while acute low-doses could produce this effect (p-value ˂ 0.05). In addition, the activity levels of antioxidant enzymes SOD, CAT, and TAC were not statistically different between the radiation workers and the control group (p-value > 0.05). CONCLUSIONS: We observed that exposure to low doses of IR leads to increased cytogenetic damage, could not cause an adaptive-response, and improve antioxidant capacity in radiation workers. Controlling healthcare workers' exposure is the first step to improving the health of hospital workers and the quality of patient care, thus decreasing human and economic costs.


Asunto(s)
Antioxidantes , Personal de Hospital , Humanos , Radiación Ionizante , Superóxido Dismutasa , Hospitales
3.
J Biomed Phys Eng ; 9(2): 179-188, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31214523

RESUMEN

BACKGROUND: Given the importance of scattered and low doses in secondary cancer caused by radiation treatment, the point dose of critical organs, which were not subjected to radiation treatment in breast cancer radiotherapy, was measured. OBJECTIVE: The purpose of this study is to evaluate the peripheral dose in two techniques of breast cancer radiotherapy with two energies. MATERIAL AND METHODS: Eight different plans in two techniques (conventional and conformal) and two photon energies (6 and 15 MeV) were applied to Rando Alderson Phantom's DICOM images. Nine organs were contoured in the treatment planning system and specified on the phantom. To measure the photon dose, forty-eight thermoluminescence dosimeters (MTS700) were positioned in special places on the above nine organs and plans were applied to Rando phantom with Elekta presice linac. To obtain approximately the same dose distribution in the clinical organ volume, a wedge was used on planes with an energy of 6 MeV photon. RESULTS: Point doses in critical organs with 8 different plans demonstrated that scattering in low-energy photon is greater than high-energy photon. In contrast, neutron contamination in high-energy photon is not negligible. Using the wedge and shield impose greater scattering and neutron contamination on patients with low-and high-energy photon, respectively. CONCLUSION: Deciding on techniques and energies required for preparing an acceptable treatment plan in terms of scattering and neutron contamination is a key issue that may affect the probability of secondary cancer in a patient.

4.
J Biomed Phys Eng ; 8(1): 3-12, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29732336

RESUMEN

BACKGROUND: One of the main causes of induction of secondary cancer in radiation therapy is neutron contamination received by patients during treatment. Objective: In the present study the impact of wedge and block on neutron contamination production is investigated. The evaluations are conducted for a 15 MV Siemens Primus linear accelerator. METHODS: Simulations were performed using MCNPX Monte Carlo code. 30˚, 45˚ and 60˚ wedges and a cerrobend block with dimensions of 1.5 × 1.5 × 7 cm3 were simulated. The investigation were performed in the 10 × 10 cm2 field size at source to surface distance of 100 cm for depth of 0.5, 2, 3 and 4 cm in a water phantom. Neutron dose was calculated using F4 tally with flux to dose conversion factors and F6 tally. RESULTS: Results showed that the presence of wedge increases the neutron contamination when the wedge factor was considered. In addition, 45˚ wedge produced the most amount of neutron contamination. If the block is in the center of the field, the cerrobend block caused less neutron contamination than the open field due to absorption of neutrons and photon attenuation. The results showed that neutron contamination is less in steeper depths. The results for two tallies showed practically equivalent results. CONCLUSION: Wedge causes neutron contamination hence should be considered in therapeutic protocols in which wedge is used. In terms of clinical aspects, the results of this study show that superficial tissues such as skin will tolerate more neutron contamination than the deep tissues.

5.
J Biomed Phys Eng ; 6(3): 147-156, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27853722

RESUMEN

BACKGROUND: Breast cancer is the most frequently diagnosed cancer and the leading global cause of cancer death among women worldwide. Radiotherapy plays a significant role in treatment of breast cancer and reduces locoregional recurrence and eventually improves survival. The treatment fields applied for breast cancer treatment include: tangential, axillary, supraclavicular and internal mammary fields. OBJECTIVE: In the present study, due to the presence of sensitive organ such as thyroid inside the supraclavicular field, thyroid dose and its effective factors were investigated. MATERIALS AND METHODS: Thyroid dose of 31 female patients of breast cancer with involved supraclavicular lymph nodes which had undergone radiotherapy were measured. For each patient, three TLD-100 chips were placed on their thyroid gland surface, and thyroid doses of patients were measured. The variables of the study include shield shape, the time of patient's setup, the technologists' experience and qualification. Finally, the results were analyzed by ANOVA test using SPSS 11.5 software. RESULTS: The average age of the patients was 46±10 years. The average of thyroid dose of the patients was 140±45 mGy (ranged 288.2 and 80.8) in single fraction. There was a significant relationship between the thyroid dose and shield shape. There was also a significant relationship between the thyroid dose and the patient's setup time. CONCLUSION: Beside organ at risk such as thyroid which is in the supraclavicular field, thyroid dose possibility should be reduced. For solving this problem, an appropriate shield shape, the appropriate time of the patient's setup, etc. could be considered.

6.
J Biomed Phys Eng ; 6(1): 1-12, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27026949

RESUMEN

BACKGROUND: EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years. OBJECTIVE: The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. METHODS: Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose was measured at different points in the right anterior oblique (RAO) and right posterior oblique (RPO) fields by EBT and EBT3 films on a RANDO phantom. RESULTS: While dosimetry was performed with the same conditions for the two film types for calibration and in phantom in parotid cancer radiotherapy, the measured net optical density (NOD) in EBT film was found to be higher than that from EBT3 film. The minimum difference between these two films under calibration conditions was about 2.9% (for 0.2 Gy) with a maximum difference of 35.5% (for 0.5 Gy). In the therapeutic fields of parotid cancer radiotherapy at different points, the measured dose from EBT film was higher than the EBT3 film. In these fields the minimum and maximum measured dose differences were 16.0% and 25.5%, respectively. CONCLUSION: EBT film demonstrates higher NOD than EBT3 film. This effect may be related to the higher sensitivity of EBT film over EBT3 film. However, the obtained dose differences between these two films in low dose range can be due to the differences in fitting functions applied following the calibration process.

7.
Radiat Prot Dosimetry ; 155(1): 96-9, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23209184

RESUMEN

Although, over the past few years, the application of mammography has risen up sharply in Iran, very little, if any, has been reported of the extent of patient's dose from this type of imaging. The purpose of this study was to establish local diagnostic reference level (DRL) arising from mammography in the great Khorasan province of Iran. It is generally assumed that the glandular tissue is the most vulnerable type of breast tissue. Therefore, the mean glandular dose (MGD) has been widely accepted as the most appropriate dosimetric quantity to predict the risk of radiation-induced cancer. Literary, DRL for mammography is defined as the 75th percentile of MGD distribution. In Khorasan province, 7 out of 40 centres were randomly selected. In this work, 100 patients were studied. Thermoluminescence dosimeters have been used to measure entrance surface doses (ESDs). Since, it is difficult to directly measure MGD, Monte Carlo model-based conversion factors were utilised to conclude MGD from ESD. The results have revealed that patients dose is varied widely. The measured ESDs ranged from 0.74 to 19.81 mGy for the craniocaudal (CC) view and 1.20 to 25.79 mGy for the mediolateral oblique (MLO) view. The average MGDs per image were 0.88 and 1.11 mGy for CC and MLO views, respectively. Based on the internationally adopted definition, DRL arising from mammography tests for Khorasan is 1.33 mGy. Implementation of a dose reduction programme is suggested because of the large variations observed in patient MGD values. In this study, the DRL value is significantly lower than the corresponding values suggested by other researchers elsewhere.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/efectos de la radiación , Mamografía/efectos adversos , Neoplasias Inducidas por Radiación/diagnóstico , Adulto , Anciano , Mama/patología , Neoplasias de la Mama/patología , Femenino , Humanos , Irán , Persona de Mediana Edad , Neoplasias Inducidas por Radiación/etiología , Dosis de Radiación , Monitoreo de Radiación , Valores de Referencia , Dosimetría Termoluminiscente
8.
J Med Phys ; 35(1): 42-7, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20177569

RESUMEN

In this study, we simulated a Siemens E.CAM SPECT system using SIMIND Monte Carlo program to acquire its experimental characterization in terms of energy resolution, sensitivity, spatial resolution and imaging of phantoms using (99m)Tc. The experimental and simulation data for SPECT imaging was acquired from a point source and Jaszczak phantom. Verification of the simulation was done by comparing two sets of images and related data obtained from the actual and simulated systems. Image quality was assessed by comparing image contrast and resolution. Simulated and measured energy spectra (with or without a collimator) and spatial resolution from point sources in air were compared. The resulted energy spectra present similar peaks for the gamma energy of (99m)Tc at 140 KeV. FWHM for the simulation calculated to 14.01 KeV and 13.80 KeV for experimental data, corresponding to energy resolution of 10.01 and 9.86% compared to defined 9.9% for both systems, respectively. Sensitivities of the real and virtual gamma cameras were calculated to 85.11 and 85.39 cps/MBq, respectively. The energy spectra of both simulated and real gamma cameras were matched. Images obtained from Jaszczak phantom, experimentally and by simulation, showed similarity in contrast and resolution. SIMIND Monte Carlo could successfully simulate the Siemens E.CAM gamma camera. The results validate the use of the simulated system for further investigation, including modification, planning, and developing a SPECT system to improve the quality of images.

9.
Radiat Prot Dosimetry ; 132(4): 415-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19122212

RESUMEN

In this work, the general purpose Monte Carlo N-particle radiation transport computer code (MCNP-4C) was used for the simulation of X-ray spectra in diagnostic radiology. The electron's path in the target was followed until its energy was reduced to 10 keV. A user-friendly interface named 'diagnostic X-ray spectra by Monte Carlo simulation (DXRaySMCS)' was developed to facilitate the application of MCNP-4C code for diagnostic radiology spectrum prediction. The program provides a user-friendly interface for: (i) modifying the MCNP input file, (ii) launching the MCNP program to simulate electron and photon transport and (iii) processing the MCNP output file to yield a summary of the results (relative photon number per energy bin). In this article, the development and characteristics of DXRaySMCS are outlined. As part of the validation process, output spectra for 46 diagnostic radiology system settings produced by DXRaySMCS were compared with the corresponding IPEM78. Generally, there is a good agreement between the two sets of spectra. No statistically significant differences have been observed between IPEM78 reported spectra and the simulated spectra generated in this study.


Asunto(s)
Simulación por Computador , Modelos Estadísticos , Método de Montecarlo , Radiometría , Algoritmos , Humanos , Modelos Biológicos , Dosis de Radiación , Programas Informáticos , Rayos X
10.
Radiat Prot Dosimetry ; 128(3): 363-6, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-17627955

RESUMEN

A detailed study of radiation doses received by 83 patients who underwent coronary angiography (CA) and 26 patients who underwent percutaneous transluminal coronary angioplasty (PTCA) by the femoral route in two hospitals in Mashhad-Iran is presented. All procedures were undertaken with Siemens angioscope X-ray equipment. Thermoluminescent dosimeters (TLD-100), suitably calibrated, were used to measure the dose received at five locations on the patient's skin (on the thyroid, gonads and lens of eyes). A dose area product (DAP) meter was also used. DAP values and fluoroscopy times were recorded for each patient. The mean values for DAP were 32.47+/-4.03 and 44.49+/-5.64 Gy cm2 for CA and PTCA, respectively. The patient dosimetry results revealed the thyroid receives the highest dose in CA and PTCA examinations. Also, in this study, DAP to effective dose conversion factors were estimated by means of a Rando phantom and the effective dose received by the patients was estimated for CA and PTCA examinations. The estimated mean values of effective dose were 6.75+/-0.85 and 9.61+/-1.24 mSv, respectively.


Asunto(s)
Angioplastia Coronaria con Balón , Angiografía Coronaria , Ojo/efectos de la radiación , Femenino , Gónadas/efectos de la radiación , Humanos , Irán , Masculino , Dosis de Radiación , Efectividad Biológica Relativa , Piel/efectos de la radiación , Dosimetría Termoluminiscente , Glándula Tiroides/efectos de la radiación