Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Biomater Sci Polym Ed ; 19(4): 467-77, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18318959

RESUMEN

The surfaces of high-density or ultra-high-molecular-weight polyethylenes were hydroxylated using a two-step process. The wetting and wear properties of the untreated (virgin) and surface hydroxylated polyethylenes were compared. The introduction of hydroxyl groups provided an increase in surface hydrophilicity resulting in reduced wear. Hydrophilicity was analyzed by optical analysis of water contact angle. Wear was determined by weight loss under conditions of a reciprocating pin-on-plate apparatus with the panels immersed in water or calf serum. These results suggest that hydroxylation of polyethylene friction-bearing orthopedic surfaces may lead to a longer joint life.


Asunto(s)
Materiales Biocompatibles/química , Polietileno/química , Materiales Biocompatibles/farmacología , Fricción , Hidróxidos/química , Hidroxilación , Articulaciones/efectos de los fármacos , Peso Molecular , Óptica y Fotónica , Polietileno/farmacología , Propiedades de Superficie , Agua/química
2.
J Pediatr Gastroenterol Nutr ; 33(3): 271-5, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11593121

RESUMEN

OBJECTIVES: This study presents seven cases of severe hepatobiliary and pancreatic complications of ascariasis in children. The authors describe the clinical, laboratory, and imaging findings, as well as the patients' clinical evolution. METHODS: These cases were studied within a period of approximately 1 year and included children younger than 11 years (mean age, 4.4 years). The authors reviewed their medical history and evaluated the results of their main diagnostic examinations. RESULTS: All of the patients had vomiting, abdominal pain, pallor, and abdominal distension at presentation. Passage of Ascaris lumbricoides in stool occurred in five cases, emesis with worms in three, fever in three, and hepatomegaly in two. Five patients had pancreatitis, of which two were necrohemorrhagic and one had pseudocyst of the pancreas. In three patients, A. lumbricoides was present in the pancreatic duct. Two patients had hepatic abscess (28.6%), and one of them also had cholangitis. One of the patients with pancreatitis also had signs of cholecystitis at presentation. CONCLUSIONS: Ultrasonography was the imaging diagnostic method of choice and demonstrated the presence of A. lumbricoides in the biliary and the pancreatic ducts, as well as signs of pancreatitis, cholecystitis, and hepatic abscess. Endoscopic retrograde cholangiopancreatography, used to confirm the diagnosis, was a fundamental procedure in the treatment, allowing the removal of worms from the biliary duct in four of seven patients.


Asunto(s)
Ascariasis/complicaciones , Ascaris lumbricoides/aislamiento & purificación , Enfermedades de las Vías Biliares/diagnóstico , Hígado/parasitología , Páncreas/parasitología , Enfermedades Pancreáticas/diagnóstico , Dolor Abdominal/etiología , Animales , Ascariasis/diagnóstico , Enfermedades de las Vías Biliares/parasitología , Niño , Preescolar , Heces/parasitología , Femenino , Humanos , Lactante , Parasitosis Intestinales/diagnóstico , Parasitosis Intestinales/diagnóstico por imagen , Hígado/diagnóstico por imagen , Hígado/patología , Masculino , Páncreas/diagnóstico por imagen , Páncreas/patología , Enfermedades Pancreáticas/parasitología , Ultrasonografía , Vómitos/etiología
3.
J Interv Card Electrophysiol ; 2(1): 41-5, 1998 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-9869995

RESUMEN

INTRODUCTION: A variety of factors, including the number of defibrillation electrodes and shocking capacitance, may influence the defibrillation efficacy of an implantable defibrillator system. Therefore, the purpose of this study was to compare the defibrillation energy requirement using a 125 uF two-electrode defibrillation system and a 90 uF three-electrode defibrillation system. METHODS AND RESULTS: The defibrillation energy requirements measured with both systems were compared in 26 consecutive patients. The two-electrode system used a single transvenous lead with two defibrillation coils in conjunction with a biphasic waveform from a 125 uF capacitor. The three-electrode system used the same transvenous lead, utilized a pectoral implantable defibrillator generator shell as a third electrode, and delivered the identical biphasic waveform from a 90 uF capacitor. The two-electrode system was associated with a higher defibrillation energy requirement (10.8 +/- 5.5 J) than was the three-electrode system (8.9 +/- 6.7 J, p < 0.05), however, the leading edge voltage was not significantly different between systems (361 +/- 103 V vs. 397 +/- 123 V, P = 0.07). The two-electrode system also had a higher shocking resistance (49.0 +/- 9.0 ohms vs. 41.4 +/- 7.3 ohms, p < 0.001) and a lower peak current (7.7 +/- 2.6 A vs. 10.1 +/- 3.7 A, p < 0.001) than the three-electrode system. CONCLUSIONS: A three-electrode defibrillation system that utilizes a dual coil transvenous lead and a subcutaneous pectoral electrode with lower capacitance is associated with a lower defibrillation energy requirement than is a dual coil defibrillation system with higher capacitance. This finding suggests that the utilization of a pectoral generator as a defibrillation electrode in conjunction with smaller capacitors is a more effective defibrillation system and may allow for additional miniaturization of implantable defibrillators.


Asunto(s)
Desfibriladores Implantables , Electrodos Implantados , Anciano , Arritmias Cardíacas/terapia , Distribución de Chi-Cuadrado , Conductividad Eléctrica , Impedancia Eléctrica , Suministros de Energía Eléctrica , Diseño de Equipo , Femenino , Humanos , Modelos Lineales , Masculino , Estudios Prospectivos , Síncope/terapia , Taquicardia Ventricular/terapia
4.
Am J Cardiol ; 82(9): 1052-5, 1998 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-9817480

RESUMEN

With use of transesophageal echocardiography, the short-term effects of transthoracic electrical cardioversion of atrial flutter (AFI) on atrial mechanical function and spontaneous echo contrast were determined. Thirty patients who had AFI for a mean of 6.4 +/- 12.2 months underwent transthoracic cardioversion. A transesophageal echocardiogram was recorded immediately before cardioversion, and left atrial appendage emptying velocity and spontaneous contrast were assessed serially at 1, 3, and 5 minutes after cardioversion in 28 patients, and also at 8, 10, and 15 minutes after cardioversion in a subgroup of 13 patients. Cardioversion was deferred in 2 patients (7%) because a thrombus was found in the left atrial appendage. Before cardioversion, spontaneous contrast was present in the left atrium in 7 of 28 patients (25%) who underwent cardioversion. The mean left atrial appendage emptying velocity of 54 +/- 22 cm/s before cardioversion fell by 26% to 40 +/- 25 cm/s at 1 minute after restoration of sinus rhythm (p <0.01). There were no significant changes in the mean left atrial appendage-emptying velocity between 1 and 15 minutes after cardioversion. Within 5 minutes after conversion to sinus rhythm, left atrial spontaneous echo contrast developed de novo or worsened in 12 of the 28 patients (43%). In conclusion, the results of this study demonstrate that persistent AFI may be associated with left atrial thrombi before cardioversion and that cardioversion of AFI is associated with a significant degree of atrial stunning and formation of spontaneous echo contrast.


Asunto(s)
Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/fisiopatología , Aleteo Atrial/terapia , Función del Atrio Izquierdo , Ecocardiografía Transesofágica , Cardioversión Eléctrica , Adulto , Anciano , Enfermedad Crónica , Trombosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
5.
Am Heart J ; 135(6 Pt 1): 945-51, 1998 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9630097

RESUMEN

BACKGROUND: The electrophysiologic effects of norepinephrine (NE) in human beings have not been previously described. METHODS: The electrophysiologic effects of NE infused at a rate of 25 ng/kg/min were determined in 21 patients with a mean age of 41 +/- 11 years and without structural heart disease who underwent an electrophysiology procedure. In a subgroup of 10 patients electrophysiologic parameters were measured at baseline, after the infusion of NE, and after administration of beta-blockade while in continuous NE infusion. RESULTS: The baseline NE plasma concentration of 298 +/- 153 pg/ml increased to 708 +/- 419 pg/ml after the infusion of NE. NE significantly increased the mean blood pressure, sinus cycle length, corrected sinus node recovery time, ventriculoatrial block cycle length, and the atrial and ventricular effective refractory periods. In a subset of 10 patients 0.2 mg/kg propranolol administered during continued infusion of NE resulted in a further increase in sinus cycle length, atrial-His interval, and ventricular refractoriness. CONCLUSION: A physiologic elevation in the plasma NE concentration results in a depression of sinus node function and atrioventricular conduction and in prolongation of atrial and ventricular refractoriness. Some of NE's effects are partially offset by beta-adrenergic stimulation.


Asunto(s)
Agonistas alfa-Adrenérgicos/farmacología , Corazón/efectos de los fármacos , Norepinefrina/farmacología , Agonistas alfa-Adrenérgicos/administración & dosificación , Agonistas Adrenérgicos beta/farmacología , Adulto , Nodo Atrioventricular/efectos de los fármacos , Presión Sanguínea/efectos de los fármacos , Electrofisiología , Epinefrina/farmacología , Femenino , Corazón/fisiología , Humanos , Masculino , Norepinefrina/administración & dosificación , Norepinefrina/sangre , Propranolol/farmacología
6.
J Electrocardiol ; 31(2): 133-6, 1998 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-9588659

RESUMEN

Ventricular pace mapping may be used to identify the site of origin of idiopathic ventricular tachycardia. Isoproterenol is often required to induce this type of ventricular tachycardia, but its effect on QRS morphology during pace mapping is unknown. Therefore, this study was performed to evaluate the effect of isoproterenol on QRS morphology during ventricular pacing. The study population consisted of 20 patients (mean age 38 +/- 14 years) undergoing a clinically indicated electrophysiology procedure. Ventricular overdrive pacing was performed in trains of 12 stimuli at cycle lengths of 400, 350, 300, and 250 ms, first in the baseline state during an infusion of isoproterenol, and again after isoproterenol washout. Pacing was performed at the right ventricular apex in 10 patients, in the right ventricular outflow tract in 6 patients, and in the left ventricle in 4 patients. Visual evaluation revealed no apparent effects of isoproterenol on QRS morphology at any of the three pacing sites or at any of the pacing cycle lengths. It was concluded that QRS morphology during ventricular pacing is not affected by isoproterenol infusion. Therefore, in patients with idiopathic ventricular tachycardia, even if the induction of tachycardia requires infusion of isoproterenol, successful pace mapping may be performed in its absence.


Asunto(s)
Estimulación Cardíaca Artificial , Cardiotónicos , Electrocardiografía/efectos de los fármacos , Isoproterenol , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Anciano , Ablación por Catéter , Femenino , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía
7.
Circulation ; 96(5): 1525-31, 1997 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-9315542

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillator (ICD) therapy is integral to current therapy for ventricular tachycardia. Patients with an ICD frequently require concomitant antiarrhythmic drug therapy. Despite this, some patients still receive frequent ICD therapies for ventricular tachycardia. Therefore, the purpose of this prospective study was to determine the utility of ablation of ventricular tachycardia in patients with an ICD who experience frequent ICD therapies. METHODS AND RESULTS: Twenty-one consecutive patients with frequent ICD therapies despite antiarrhythmic drug therapy were the subjects of this study. The mean age was 69+/-6 years, and 17 were men. The mean ejection fraction was 0.22+/-0.08, and all patients had coronary artery disease. During the 36+/-51 days (range, 4 days to 7 months) preceding the ablation procedures, the patients received 34+/-55 ICD therapies for the clinical ventricular tachycardia, or a mean of 25+/-88 ICD therapies per month. The patients underwent radiofrequency ablation of the presumed clinical ventricular tachycardia by inducing the tachycardia and mapping according to endocardial activation, continuous electrical activity, pace mapping, concealed entrainment, or mid-diastolic potentials. Ablation of the clinical arrhythmia was successful in 76% of patients during 1.4+/-0.6 (range, 1 to 3) ablation procedures and required 12.5+/-9.2 applications of energy. During 11.8+/-10.0 months of follow-up, the frequency of ICD therapies per month decreased from 60+/-80 before successful ablation to 0.1+/-0.3 ICD therapies per month after ablation (P=.01). A quality-of-life assessment demonstrated a significant improvement after successful (P=.02) but not unsuccessful ablation (P=.9). CONCLUSIONS: Radiofrequency ablation of ventricular tachycardia as adjuvant therapy in patients with coronary artery disease and an ICD has a reasonable success rate, significantly reduces ICD therapies, and appears to be associated with an improved quality of life.


Asunto(s)
Ablación por Catéter , Enfermedad Coronaria/cirugía , Desfibriladores Implantables , Taquicardia Ventricular/cirugía , Anciano , Estimulación Cardíaca Artificial , Estudios de Cohortes , Estudios de Evaluación como Asunto , Femenino , Estudios de Seguimiento , Predicción , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Retratamiento , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
8.
Circulation ; 96(5): 1532-6, 1997 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-9315543

RESUMEN

BACKGROUND: Because it is not clear which technique is less expensive, the purpose of this study was to compare the cost of radiofrequency modification and ablation of the atrioventricular (AV) node in drug-refractory patients with atrial fibrillation and an uncontrolled ventricular rate. METHODS AND RESULTS: The initial nominal charges for a successful procedure were compared in 10 patients with chronic atrial fibrillation who underwent modification of the AV node ($13 109+/-2002) and 14 similar patients who underwent ablation and pacemaker implantation ($28 302+/-2023, P<.001). On the basis of the long-term follow-up of patients who underwent each procedure, it was assumed that 31% of patients selected for the modification procedure would require a permanent pacemaker for inadvertent AV block or because of AV nodal ablation after a failed modification procedure and that the recurrence rate after AV node ablation would be 2%. The annual charges during follow-up were predicted and adjusted for recurrences and the need for additional procedures. The adjusted total charges at 1 year of follow-up were significantly lower for the modification procedure ($19 389+/-2002) than for the ablation procedure ($28 485+/-2023, P<.001). After 10 years of follow-up, the cumulative, adjusted charges for modification were $20 016 (42%) less than for ablation. CONCLUSIONS: The initial charges generated by AV node modification are significantly lower than for AV node ablation in patients with chronic atrial fibrillation. Even when adjusted for higher failure and recurrence rates, the modification procedure retains a major cost advantage over ablation during long-term follow-up.


Asunto(s)
Fibrilación Atrial/cirugía , Nodo Atrioventricular/cirugía , Costos de la Atención en Salud , Radiocirugia/economía , Anciano , Enfermedad Crónica , Análisis Costo-Beneficio , Femenino , Humanos , Masculino , Persona de Mediana Edad
9.
Circulation ; 96(5): 1542-50, 1997 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-9315545

RESUMEN

BACKGROUND: Atrial fibrillation (AF) shortens the atrial effective refractory period (ERP) and predisposes to further episodes of AF. The purpose of this study was to determine the effect of verapamil and procainamide on these manifestations of AF-induced electrical remodeling. METHODS AND RESULTS: In adult patients without structural heart disease, the atrial ERP was measured before and after AF after pharmacological autonomic blockade and administration of verapamil (17 patients), procainamide (10 patients), or saline (20 patients). AF was then induced by rapid pacing. Immediately on AF conversion, the post-AF ERP was measured at alternating drive cycle lengths of 350 and 500 ms. In the saline group, the pre-AF and first post-AF ERPs at the 350-ms drive cycle length were 206+/-19 and 179+/-27 ms (P<.0001), respectively, and at the 500-ms drive cycle length, the values were 217+/-16 and 183+/-23 ms, respectively (P<.0001). There was a similar significant shortening of the first post-AF ERP in the procainamide group. In the verapamil group, however, there was no difference between the pre-AF and the first post-AF ERP at the 350-ms (226+/-15 versus 227+/-22 ms, P=.8) or 500-ms (230+/-17 versus 232+/-20 ms, P=.6) drive cycle length. During determinations of the post-AF ERP, 105 secondary episodes of AF were unintentionally induced in 12% of verapamil patients compared with 90% and 80% of saline and procainamide patients (P<.01 versus verapamil). CONCLUSIONS: Pretreatment with the calcium channel antagonist verapamil, but not the sodium channel antagonist procainamide, markedly attenuates acute, AF-induced changes in atrial electrophysiological properties. These data suggest that calcium loading during AF may be at least partially responsible for AF-induced electrical remodeling.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/fisiopatología , Función Atrial , Procainamida/uso terapéutico , Verapamilo/uso terapéutico , Adulto , Fibrilación Atrial/etiología , Estimulación Cardíaca Artificial , Electrofisiología , Femenino , Humanos , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Recurrencia , Periodo Refractario Electrofisiológico , Factores de Tiempo
10.
Ann Intern Med ; 127(6): 417-22, 1997 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-9312997

RESUMEN

BACKGROUND: Adenosine is considered safe and effective for paroxysmal supraventricular tachycardia (PSVT), but anecdotal experience suggests that adenosine can precipitate atrial arrhythmias. OBJECTIVES: To determine the frequency and mechanisms of adenosine-induced atrial arrhythmias. SETTING: Clinical electrophysiology laboratory at a university medical center. DESIGN: Prospective observational study. PATIENTS: 200 consecutive patients with PSVT undergoing an electrophysiology procedure. INTERVENTION: During PSVT, 12 mg of adenosine was administered centrally through the femoral vein. MEASUREMENTS: Frequency of adenosine-induced atrial fibrillation. RESULTS: Paroxysmal supraventricular tachycardia terminated after adenosine administration in 198 patients (99% [95% CI, 96% to 100%]). Adenosine led to atrial fibrillation (n = 22) or atrial fibrillation and atrial flutter (n = 2) in 24 patients (12% [CI, 7.5% to 16.5%]). An atrial premature complex occurred in all 24 patients who developed atrial fibrillation, atrial flutter, or both and in 102 of the 176 patients (58%) who did not (P < 0.001). The mean (+/-SD) time from the preceding atrial complex to the atrial premature complex was shorter when an atrial arrhythmia occurred, and the mean ratio of this interval to the preceding atrial cycle length was also lower when atrial fibrillation developed (0.37 +/- 0.16 compared with 0.49 +/- 0.16; P = 0.002). CONCLUSIONS: The incidence of atrial fibrillation induced by 12 mg of adenosine administered through the femoral vein was 12%. Fibrillation seems to be associated with a "long-short" atrial sequence. If the mechanism of PSVT is unknown and the Wolff-Parkinson-White syndrome is possible, administration of adenosine should be limited to medical facilities that have emergency resuscitation equipment.


Asunto(s)
Adenosina/efectos adversos , Antiarrítmicos/efectos adversos , Fibrilación Atrial/inducido químicamente , Aleteo Atrial/inducido químicamente , Taquicardia Paroxística/tratamiento farmacológico , Taquicardia Supraventricular/tratamiento farmacológico , Adulto , Electrocardiografía , Femenino , Atrios Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Taquicardia Paroxística/fisiopatología , Taquicardia Supraventricular/fisiopatología , Síndrome de Wolff-Parkinson-White/inducido químicamente
11.
J Cardiovasc Electrophysiol ; 8(9): 974-9, 1997 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9300293

RESUMEN

INTRODUCTION: The purpose of this study was to determine the accuracy of the unipolar electrogram for identifying the earliest site of ventricular activation. The earliest site of ventricular activation may be identified with the unipolar electrogram by the absence of an R wave. However, the accuracy of this technique is unknown. METHODS AND RESULTS: A single ventricular premature complex was induced mechanically at the tip of an electrode catheter to simulate a ventricular premature depolarization site of origin. Unipolar electrograms were recorded from the right ventricular septum at the tip electrode and at 2, 5, 8, and 11 mm from the electrode tip in 20 patients. No R waves were detected at the ventricular premature depolarization site of origin. R waves were detected in 4 of 20 patients (20%) at 2 mm from the tip electrode and 7 of 20 patients (35%) at 5, 8, and 11 mm from the tip electrode. An R wave was not observed at distances < or = 11 mm from the site of tachycardia origin in 13 of 20 patients (65%). CONCLUSIONS: While an R wave in the unipolar electrogram can be seen as close as 2 mm from the site of impulse origin, the absence of an R wave as an indicator of the site of impulse origin in the right ventricle is highly inaccurate. Therefore, the absence of an R wave in the unipolar electrogram is unlikely to be an adequate guide for identification of an effective target site for ablation of right ventricular tachycardia.


Asunto(s)
Electrocardiografía/métodos , Complejos Prematuros Ventriculares/diagnóstico , Adulto , Anciano , Ablación por Catéter , Errores Diagnósticos , Electrocardiografía/instrumentación , Electrodos , Electrofisiología/instrumentación , Electrofisiología/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Disfunción Ventricular Derecha/diagnóstico , Disfunción Ventricular Derecha/cirugía , Complejos Prematuros Ventriculares/cirugía
12.
J Am Coll Cardiol ; 30(2): 505-13, 1997 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9247525

RESUMEN

OBJECTIVES: The goal of this study was to determine whether isolated diastolic potentials (IDPs) recorded during ventricular tachycardia (VT) are generated in zones of slow conduction and whether the arcs of block that bound these zones of slow conduction are functional or anatomic in nature. BACKGROUND: No previous studies have systematically investigated the response to pacing during VT and sinus rhythm at sites where IDPs are recorded. METHODS: The study included 11 patients with a previous infarction who underwent radiofrequency catheter ablation of 15 hemodynamically stable, sustained VTs and in whom an IDP that could not be dissociated from the VT was detected during mapping. RESULTS: Pacing during VT at the site where the IDP was recorded resulted in concealed entrainment in each of the 15 VTs. In 10 of the 15 VTs, an IDP was present during sinus rhythm at the same site at which a diastolic potential was recorded during VT. In nine VTs, the isolated potential occurred early in diastole; in these cases, the QRS configuration during pacing in the setting of sinus rhythm was different from that during VT. In six VTs, the isolated potential occurred later in diastole, and in these cases, the QRS configuration during pacing in the setting of sinus rhythm was the same as that during VT. CONCLUSIONS: Isolated diastolic potentials may often be generated in an area of slow conduction bounded by arcs of block that are anatomically determined and present during sinus rhythm.


Asunto(s)
Estimulación Cardíaca Artificial , Infarto del Miocardio/complicaciones , Taquicardia Ventricular/fisiopatología , Ablación por Catéter , Diástole/fisiología , Electrocardiografía , Electrofisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad
13.
Circulation ; 96(4): 1217-23, 1997 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-9286952

RESUMEN

BACKGROUND: The probability of successful defibrillation has been determined in normal animals but not in patients undergoing defibrillator implantation. Therefore, the purpose of this prospective study was to determine the probability of successful defibrillation in humans on the basis of a step-down defibrillation energy requirement. METHODS AND RESULTS: Fifty-three consecutive patients underwent five separate inductions of ventricular fibrillation after the defibrillation energy requirement was determined with the use of small decrements and a step-down protocol (20, 15, 12, 10, 8, 6, 5, 4, 3, 2, 1, and 0.8 J). The first shock energy for defibrillation was either 1.0, 1.3, 1.5, 1.7, or 2.0 times the defibrillation energy requirement, and the likelihoods of successful defibrillation were 70+/-27%, 84+/-12%, 86+/-25%, 80+/-29%, and 88+/-32%, respectively (P=.03). The frequencies of uniformly successful defibrillation (5 of 5 defibrillation attempts) were 30%, 27%, 60%, 64%, and 73%, respectively (P=.01). Seven patients in whom the defibrillation energy requirement was <4 J had an overall rate of successful defibrillation of 54+/-20% compared with 86+/-20% in the remaining 47 patients (P=.002). The likelihood of successful defibrillation at twice the defibrillation energy requirement was 98% in the 46 patients with a defibrillation energy requirement of >4 J and 67% in the 7 patients with a defibrillation energy requirement of <4 J (P=.17). An absolute safety margin of 7 J was associated with a 96% probability of successful defibrillation. CONCLUSIONS: The probability of successful defibrillation is 70% at the defibrillation energy requirement. The probability plateaus at 88%, at twice the defibrillation energy requirement. A 96% probability of successful defibrillation is achieved at an absolute safety margin of 7 J, and a 98% success rate is achieved at energies that are twice the defibrillation energy requirement if the defibrillation energy requirement is >4 J. If the defibrillation energy requirement is <4 J, larger multiples of the defibrillation energy requirement are needed to achieve a high probability of successful defibrillation.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica , Cardioversión Eléctrica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
14.
Am J Cardiol ; 80(2): 226-7, 1997 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-9230170

RESUMEN

This study determined the efficacy of single- and multisite atrial pacing for terminating episodes of atrial fibrillation induced in patients in the electrophysiology laboratory. One- to 5-second bursts of atrial pacing at a cycle length of 20 ms were not effective in terminating atrial fibrillation, when delivered either in the high right atrium or when delivered simultaneously at the high right atrium, midseptum, and coronary sinus.


Asunto(s)
Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia del Tratamiento
15.
Circulation ; 95(1): 183-90, 1997 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-8994435

RESUMEN

BACKGROUND: Concealed entrainment has been useful in guiding catheter ablation of monomorphic ventricular tachycardia in patients with coronary artery disease. However, not all sites with concealed entrainment result in successful ablation of the targeted ventricular tachycardia. The purpose of this prospective study was to identify factors at sites that demonstrate concealed entrainment that differentiate effective from ineffective target sites. METHODS AND RESULTS: In 14 consecutive patients with hemodynamically stable monomorphic ventricular tachycardia and coronary artery disease, radiofrequency ablation of 26 ventricular tachycardias was performed. Ablation was attempted at 46 sites that demonstrated concealed entrainment. Twenty-five of the targeted ventricular tachycardias (96%) were successfully ablated. The positive predictive value of concealed entrainment for successful ablation was 54%; it increased to 72% in the presence of a stimulus-QRS interval/ventricular tachycardia cycle length ratio of < or = 70%, to 82% in the presence of a match of the stimulus-QRS and electrogram-QRS interval, and to 89% in the presence of isolated mid diastolic potentials that could not be dissociated from ventricular tachycardia during entrainment. CONCLUSIONS: The positive predictive value of concealed entrainment for identification of successful ablation sites in patients with sustained ventricular tachycardia and coronary artery disease can be significantly enhanced by the presence of associated mapping criteria, particularly an isolated mid diastolic potential that cannot be dissociated from the tachycardia.


Asunto(s)
Ablación por Catéter , Electrocardiografía , Taquicardia Ventricular/cirugía , Adulto , Anciano , Enfermedad Coronaria/complicaciones , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología
16.
J Am Coll Cardiol ; 29(1): 113-21, 1997 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8996303

RESUMEN

OBJECTIVES: The purpose of this study was to describe the long-term follow-up results in 62 patients with atrial fibrillation and an uncontrolled ventricular rate, who underwent radiofrequency modification of the atrioventricular (AV) node. BACKGROUND: Previous studies in small numbers of patients have suggested that radiofrequency modification may be effective in controlling the ventricular rate in patients with atrial fibrillation, but long-term follow-up data have been lacking. METHODS: The subjects of this study were 62 consecutive patients (mean age +/- SD 65 +/- 14 years; 43 with structural heart disease) who underwent an attempt at radiofrequency modification of the AV node because of symptomatic, drug-refractory atrial fibrillation with an uncontrolled ventricular rate. The atrial fibrillation was chronic in 46 patients and paroxysmal in 16. Radiofrequency energy was applied to the posteroseptal or mid-septal right atrium to lower the ventricular rate in atrial fibrillation to 120 to 130 beats/min during an infusion of 4 micrograms/min of isoproterenol. RESULTS: Short-term control of the ventricular rate was successfully achieved without the induction of pathologic AV block in 50 (81%) of 62 patients. Inadvertent high degree AV block occurred in 10 (16%) of 62 patients, with the AV block occurring at the time of the procedure in 6 patients and 36 to 72 h after the procedure in 4. During 19 +/- 8 months of follow-up (range 4 to 33), 5 (10%) of 50 patients had a symptomatic recurrence of an uncontrolled rate during atrial fibrillation. Overall, adequate rate control at rest and during exertion, without pathologic AV block, was achieved long term in 45 (73%) of 62 patients. Among 37 patients with a successful outcome, left ventricular ejection fraction increased from (mean +/- SD) 0.44 +/- 0.14 to 0.51 +/- 0.10 one year later (p < 0.001). Complications other than AV block included polymorphic ventricular tachycardia 10 to 24 h after the procedure in two patients who had a predisposing factor for ventricular tachycardia and sudden death 1 to 5 months after the procedure in two patients with idiopathic dilated cardiomyopathy, one of whom had a pacemaker for AV block. CONCLUSIONS: In approximately 70% of properly selected patients with atrial fibrillation and an uncontrolled ventricular rate, radiofrequency modification of the AV node results in excellent long-term control of the ventricular rate at rest and during exertion.


Asunto(s)
Fibrilación Atrial/cirugía , Nodo Atrioventricular/cirugía , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Nodo Atrioventricular/fisiopatología , Ablación por Catéter/efectos adversos , Enfermedad Crónica , Electrocardiografía Ambulatoria , Prueba de Esfuerzo , Femenino , Estudios de Seguimiento , Bloqueo Cardíaco/etiología , Humanos , Masculino , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
17.
J Interv Card Electrophysiol ; 1(4): 299-303, 1997 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9869984

RESUMEN

Temperature monitoring may be helpful for ablation of accessory pathways, however its role in ablation of atrioventricular nodal reentrant tachycardia (AVNRT) using the slow pathway approach is unclear. Therefore, the purpose of this study was to prospectively compare slow pathway ablation for AVNRT using fixed power or temperature monitoring. The study included 120 patients undergoing ablation for AVNRT. Patients were randomly assigned to receive either fixed power at 32 watts, or to temperature monitoring with a target temperature of 60 degrees C. The primary success rate was 72% in the fixed power group and 95% in the temperature monitoring group (p = 0.001). The ablation procedure duration (35 +/- 29 min vs 35 +/- 30 min; p = 0.9), fluoroscopic time (32 +/- 17 vs 35 +/- 19 min; p = 0.4), mean number of applications (10.2 +/- 8.1 vs 8.4 +/- 7.9; p = 0.2), and coagulum formation per application (0.2% vs 0.5%; p = 0.6) were statistically similar in the fixed power and temperature monitoring groups, respectively. The mean temperature (47.3 +/- 4.8 degrees C vs 48.6 +/- 3.8 degrees C; p < 0.01), and the temperature associated with junctional ectopy (48.2 +/- 3.8 degrees C vs 49.3 +/- 3.6 degrees C, p < 0.01) were less for the fixed power than the temperature monitoring group. In the temperature monitoring group, only 31% of applications achieved an electrode temperature of 60 degrees C. During follow up of 6.6 +/- 3.6 months there were two recurrences in the fixed power group and one in the temperature monitoring group (p = 1.0). In summary, power titration directed by temperature monitoring was associated with an improved primary procedural success rate. Applications of energy were associated with a temperature of approximately 50 degrees C with both techniques, suggesting that there is a low efficiency of heating in the posterior septum.


Asunto(s)
Ablación por Catéter/métodos , Electrodos , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Temperatura , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Resultado del Tratamiento
18.
Am J Cardiol ; 80(12): 1609-10, 1997 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-9416948

RESUMEN

Four of 12 patients (33%) with paroxysmal supraventricular tachycardia (PSVT) and tachycardia-induced atrial fibrillation (AF) had recurrences of paroxysmal AF after successful catheter ablation of the PSVT. This study demonstrates that AF often remains a problem after radiofrequency catheter ablation of PSVT in patients with tachycardia-induced AF, and it may not be possible to predict in which patients this will be the case.


Asunto(s)
Fibrilación Atrial/etiología , Ablación por Catéter , Taquicardia Paroxística/cirugía , Taquicardia Supraventricular/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Taquicardia Paroxística/complicaciones , Taquicardia Supraventricular/complicaciones
19.
Am J Cardiol ; 80(12): 1611-2, 1997 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-9416949

RESUMEN

In a retrospective analysis of patients referred for atrioventricular node radiofrequency ablation, male gender and a history of hypertension were found to be predictors of crossover to a left ventricular approach for success. This subgroup of patients may benefit from early crossover if initial attempts at right-sided ablation fail.


Asunto(s)
Nodo Atrioventricular/cirugía , Fascículo Atrioventricular/cirugía , Ablación por Catéter/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
20.
Circulation ; 94(11): 2843-9, 1996 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-8941111

RESUMEN

BACKGROUND: Ventricular pace mapping is performed by comparing the QRS morphology of ventricular paced complexes to that of a template arrhythmia, either a premature ventricular depolarization or a QRS complex during ventricular tachycardia. The objective of this study was to evaluate the effect of coupling interval and pacing cycle length on QRS morphology. METHODS AND RESULTS: The study population consisted of 20 patients (mean age, 38 +/- 16 years) undergoing a clinically indicated electrophysiology procedure. In the first 10 patients, the effect of coupling interval on the morphology of single paced ventricular complexes was evaluated visually and by signal processing techniques. Visually apparent differences in QRS morphology occurred in a mean of 4/12 electrocardiographic leads with a change in coupling interval of > or = 100 ms. In the next 10 patients, the QRS complex morphology during ventricular overdrive pacing at cycle lengths of 600 and 300 ms was found to differ significantly in a mean of 4/12 leads. The QRS morphology during overdrive pacing differed significantly from that of a single paced complex whenever the pacing cycle length differed from the coupling interval of the single paced complex by > 80 ms. CONCLUSIONS: The morphology of single paced QRS complexes may vary, depending on coupling interval, and the QRS morphology during overdrive pacing is affected by the pacing cycle length. During ventricular pace mapping, the coupling interval or cycle length of the template arrhythmia should be matched during pacing. If not, rate-dependent changes in QRS morphology that are independent of the pacing site may confound the results of pace mapping.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Función Ventricular , Complejos Prematuros Ventriculares/fisiopatología , Adulto , Electrocardiografía , Procesamiento Automatizado de Datos , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...