1.
Med Phys ; 44(8): 4204-4212, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28543091

RESUMEN

PURPOSE: One of the major challenges in electromagnetic navigated bronchoscopy is the navigation accuracy. An initial rigid image-to-patient registration may not be optimal for the entire lung volume, as the lung tissue anatomy is likely to have shifted since the time of computer tomography (CT) acquisition. The accuracy of the initial rigid registration will also be affected throughout the procedure by breathing, coughing, patient movement and tissue displacements due to pressure from bronchoscopy tools. A method to minimize the negative impact from these factors by updating the registration locally during the procedure is needed and suggested in this paper. METHODS: The intraoperative local registration method updates the initial registration by optimization in an area of special interest, for example, close to a biopsy position. The local registration was developed through an adaptation of a previously published registration method used for the initial registration of CT to the patient anatomy. The method was tested in an experimental breathing phantom setup, where respiratory movements were induced by a robotic arm. Deformations were also applied to the phantom to see if the local registration could compensate for these. RESULTS: The local registration was successfully applied in all 15 repetitions, five in each of the three parts of the airway phantom. The mean registration accuracy was improved from 11.8-19.4 mm to 4.0-6.7 mm, varying to some degree in the different segments of the airway model. CONCLUSIONS: A local registration method, to update and improve the initial image-to patient registration during navigated bronchoscopy, was developed. The method was successfully tested in a breathing phantom setup. Further development is needed to make the method more automatic. It must also be verified in human studies.


Asunto(s)
Broncoscopía , Fantasmas de Imagen , Biopsia , Fenómenos Electromagnéticos , Humanos , Pulmón/diagnóstico por imagen , Respiración , Tomografía Computarizada por Rayos X
2.
PLoS One ; 12(2): e0171841, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28182758

RESUMEN

BACKGROUND: Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is the endoscopic method of choice for confirming lung cancer metastasis to mediastinal lymph nodes. Precision is crucial for correct staging and clinical decision-making. Navigation and multimodal imaging can potentially improve EBUS-TBNA efficiency. AIMS: To demonstrate the feasibility of a multimodal image guiding system using electromagnetic navigation for ultrasound bronchoschopy in humans. METHODS: Four patients referred for lung cancer diagnosis and staging with EBUS-TBNA were enrolled in the study. Target lymph nodes were predefined from the preoperative computed tomography (CT) images. A prototype convex probe ultrasound bronchoscope with an attached sensor for position tracking was used for EBUS-TBNA. Electromagnetic tracking of the ultrasound bronchoscope and ultrasound images allowed fusion of preoperative CT and intraoperative ultrasound in the navigation software. Navigated EBUS-TBNA was used to guide target lymph node localization and sampling. Navigation system accuracy was calculated, measured by the deviation between lymph node position in ultrasound and CT in three planes. Procedure time, diagnostic yield and adverse events were recorded. RESULTS: Preoperative CT and real-time ultrasound images were successfully fused and displayed in the navigation software during the procedures. Overall navigation accuracy (11 measurements) was 10.0 ± 3.8 mm, maximum 17.6 mm, minimum 4.5 mm. An adequate sample was obtained in 6/6 (100%) of targeted lymph nodes. No adverse events were registered. CONCLUSIONS: Electromagnetic navigated EBUS-TBNA was feasible, safe and easy in this human pilot study. The clinical usefulness was clearly demonstrated. Fusion of real-time ultrasound, preoperative CT and electromagnetic navigational bronchoscopy provided a controlled guiding to level of target, intraoperative overview and procedure documentation.


Asunto(s)
Broncoscopía/métodos , Endosonografía/métodos , Biopsia Guiada por Imagen/métodos , Neoplasias Pulmonares/patología , Anciano , Broncoscopía/efectos adversos , Broncoscopía/instrumentación , Endosonografía/instrumentación , Estudios de Factibilidad , Humanos , Biopsia Guiada por Imagen/instrumentación , Imagen Multimodal/instrumentación , Imagen Multimodal/métodos , Complicaciones Posoperatorias , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos
3.
Int J Comput Assist Radiol Surg ; 11(4): 505-19, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26410841

RESUMEN

PURPOSE: CustusX is an image-guided therapy (IGT) research platform dedicated to intraoperative navigation and ultrasound imaging. In this paper, we present CustusX as a robust, accurate, and extensible platform with full access to data and algorithms and show examples of application in technological and clinical IGT research. METHODS: CustusX has been developed continuously for more than 15 years based on requirements from clinical and technological researchers within the framework of a well-defined software quality process. The platform was designed as a layered architecture with plugins based on the CTK/OSGi framework, a superbuild that manages dependencies and features supporting the IGT workflow. We describe the use of the system in several different clinical settings and characterize major aspects of the system such as accuracy, frame rate, and latency. RESULTS: The validation experiments show a navigation system accuracy of [Formula: see text]1.1 mm, a frame rate of 20 fps, and latency of 285 ms for a typical setup. The current platform is extensible, user-friendly and has a streamlined architecture and quality process. CustusX has successfully been used for IGT research in neurosurgery, laparoscopic surgery, vascular surgery, and bronchoscopy. CONCLUSIONS: CustusX is now a mature research platform for intraoperative navigation and ultrasound imaging and is ready for use by the IGT research community. CustusX is open-source and freely available at http://www.custusx.org.


Asunto(s)
Algoritmos , Monitoreo Intraoperatorio/métodos , Cirugía Asistida por Computador/métodos , Humanos , Reproducibilidad de los Resultados
4.
Ultrasonics ; 51(4): 405-19, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21147493

RESUMEN

Freehand 3D ultrasound is increasingly being introduced in the clinic for diagnostics and image-assisted interventions. Various algorithms exist for combining 2D images of regular ultrasound probes to 3D volumes, being either voxel-, pixel- or function-based. Previously, the most commonly used input to 3D ultrasound reconstruction has been digitized analog video. However, recent scanners that offer access to digital image frames exist, either as processed or unprocessed data. To our knowledge, no comparison has been performed to determine which data source gives the best reconstruction quality. In the present study we compared both reconstruction algorithms and data sources using novel comparison methods for detecting potential differences in image quality of the reconstructed volumes. The ultrasound scanner used in this study was the Sonix RP from Ultrasonix Medical Corp (Richmond, Canada), a scanner that allow third party access to unprocessed and processed digital data. The ultrasound probe used was the L14-5/38 linear probe. The assessment is based on a number of image criteria: detectability of wire targets, spatial resolution, detectability of small barely visible structures, subjective tissue image quality, and volume geometry. In addition we have also performed the more "traditional" comparison of reconstructed volumes by removing a percentage of the input data. By using these evaluation methods and data from the specific scanner, the results showed that the processed video performed better than the digital scan-line data, digital video being better than analog video. Furthermore, the results showed that the choice of video source was more important than the choice of tested reconstruction algorithms.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Ultrasonografía , Análisis de Varianza , Calibración , Antebrazo/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Estadísticas no Paramétricas , Ultrasonografía/instrumentación , Grabación en Video