Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Ultrasound ; 27(2): 393-396, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38632171

RESUMEN

One of the principles of managing trauma patients is that of their continuous re-evaluation over the hours and days. Even if the execution of the computed tomography method is classically recommended, especially in the most serious cases and in polytraumas with major dynamics, the clinician can use or request an ultrasound examination, especially in subsequent re-evaluations. Here we report a clinical case demonstrating how an ultrasound re-evaluation after the acute event can lead to a correct diagnosis of a rare complication of thoracic trauma. The findings were suggestive for a pseudoaneurysm of the internal right mammary artery. Subsequently, an ultrasound-guided injection of thrombin was carried out until complete interruption of the flow within the formation. At subsequent follow-up, no arterial or venous blush was highlighted.


Asunto(s)
Aneurisma Falso , Arterias Mamarias , Humanos , Aneurisma Falso/diagnóstico por imagen , Arterias Mamarias/diagnóstico por imagen , Masculino , Ultrasonografía/métodos , Adulto , Traumatismos Torácicos/diagnóstico por imagen , Traumatismos Torácicos/complicaciones
2.
Semin Thromb Hemost ; 49(7): 744-755, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36455617

RESUMEN

Inflammatory bowel diseases (IBDs) are chronic inflammatory disorders of the gastrointestinal tract including Crohn's disease and ulcerative colitis, which may result in several extraintestinal complications (∼20-30% of cases), such as increased risk of venous thromboembolism (VTE). The main pathophysiological mechanism of VTE is an inflammation-induced hypercoagulable state, and recent data have shown that endothelial dysregulation due to gut and systemic inflammation may also lead to a prothrombotic state. Several prothrombotic alterations have been described, such as the activation of the coagulation system, platelet abnormalities, and dysregulation of fibrinolysis. Furthermore, the dysregulation of the gut microbiome seems to play a vital role in increasing systemic inflammation and thus inducing a procoagulant state. Our review aims to examine the main correlations between IBD and VTE, the underlying pathophysiology, and current therapeutic options.


Asunto(s)
Enfermedades Inflamatorias del Intestino , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/terapia , Tromboembolia Venosa/complicaciones , Enfermedades Inflamatorias del Intestino/complicaciones , Enfermedades Inflamatorias del Intestino/terapia , Coagulación Sanguínea/fisiología , Inflamación , Fibrinólisis
3.
Atmos Environ (1994) ; 45(39): 7478-7486, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22125411

RESUMEN

Exposure of black carbon (BC) is associated with a variety of adverse health outcomes. A number of optical methods for estimating BC on Teflon filters have been adopted but most assume all light absorption is due to BC while other sources of colored particulate matter exist. Recently, a four-wavelength-optical reflectance measurement for distinguishing second hand cigarette smoke (SHS) from soot-BC was developed (Brook et al., 2010; Lawless et al., 2004). However, the method has not been validated for soot-BC nor SHS and little work has been done to look at the methodological issues of the optical reflectance measurements for samples that could have SHS, BC, and other colored particles. We refined this method using a lab-modified integrating sphere with absorption measured continuously from 350 nm to 1000 nm. Furthermore, we characterized the absorption spectrum of additional components of particulate matter (PM) on PM(2.5) filters including ammonium sulfate, hematite, goethite, and magnetite. Finally, we validate this method for BC by comparison to other standard methods. Use of synthesized data indicates that it is important to optimize the choice of wavelengths to minimize computational errors as additional components (more than 2) are added to the apportionment model of colored components. We found that substantial errors are introduced when using 4 wavelengths suggested by Lawless et al. to quantify four substances, while an optimized choice of wavelengths can reduce model-derived error from over 10% to less than 2%. For environmental samples, the method was sensitive for estimating airborne levels of BC and SHS, but not mass loadings of iron oxides and sulfate. Duplicate samples collected in NYC show high reproducibility (points consistent with a 1:1 line, R(2) = 0.95). BC data measured by this method were consistent with those measured by other optical methods, including Aethalometer and Smoke-stain Reflectometer (SSR); although the SSR looses sensitivity at filter loadings above 90 ng/mm(2). Furthermore, positive correlations (R(2) = 0.7) were observed between EC measured by NIOSH Method 5040 on quartz filters and BC measured in co-located Teflon filter samples collected from both heating and non-heating seasons. Overall, the validation data demonstrates the usefulness of this method to evaluate BC from archived Teflon filters while potentially providing additional component information.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...