Phys Med Biol ; 67(7)2022 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-35272282

RESUMEN

Objective. A novel treatment modality is currently being developed that produces converging monoenergetic x-rays. Conventional application of dosimetric calibration as presented in protocol TG61 is not applicable. Furthermore, the dosimetry of the focal point of the converging beam is on the order of a few millimeters, requiring a high-resolution dosimeter. Here we present a procedure to calibrate radiochromic film for narrow-beam monoenergetic 60 keV photons as well as absolute dosimetry of monoenergetic focused x-rays. A study of the focal spot dose rate after passing through a bone-equivalent material was also done to quantify the effects of heterogeneous materials.Approach.This was accomplished by configuring a polyenergetic beam of equivalent energy using a clinical orthovoltage machine. Calibrated films were then used to perform absolute dosimetry of the converging beam by measuring the beam profile at various depths in water. Main Results.A method for calibrating radiochromic film has been developed and detailed that allows absolute dosimetry of a monoenergetic photon beam. Absolute dosimetry of a focused, mono-energetic beam resulted in a focal spot dose rate of ∼30 cGy min-1at a depth of 5 cm in water.Significance.This work serves to establish a dosimetry protocol for mono-energetic beam absolute dosimetry as well as the use of such a method for measurement of a novel teletherapy modality.


Asunto(s)
Dosimetría por Película , Radiometría , Calibración , Dosimetría por Película/métodos , Fotones/uso terapéutico , Radiometría/métodos , Agua
2.
Sci Rep ; 11(1): 19180, 2021 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-34584192

RESUMEN

We describe the development and analysis of a new teletherapy modality that, through a novel approach to targeted radiation delivery, has the potential to provide greater conformality than conventional photon-based treatments. The proposed system uses an X-ray lens to reflect photons from a conventional X-ray tube toward a focal spot. The resulting dose distributions have a highly localized peak dose, with lower doses in the converging radiation cone. Physical principles governing the design of this system are presented, along with a series of measurements analyzing various characteristics of the converging beam. The beam was designed to be nearly monoenergetic (~ 59 keV), with an energy bandwidth of approximately 10 keV allowing for treatment energies lower than conventional therapies. The focal spot was measured to be approximately 2.5 cm long and 4 mm wide. Mounting the proposed X-ray delivery system on a robotic arm would allow sub-millimeter accuracy in focal spot positioning, resulting in highly conformal dose distribution via the optimal placement of individual focal spots within the target volume. Aspects of this novel radiation beam are discussed considering their possible clinical application as a treatment approach that takes maximum advantage of the unique properties afforded by converging X-ray beam therapy.


Asunto(s)
Lentes , Fotones/uso terapéutico , Radioterapia Conformacional/instrumentación , Diseño de Equipo , Humanos , Método de Montecarlo , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica