Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
3.
Otolaryngol Head Neck Surg ; 159(1): 35-41, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29512419

RESUMEN

Objective To (1) compare physiologic changes during rigid bronchoscopy during spontaneous and mechanical ventilation and (2) evaluate the efficacy of a helium-oxygen (heliox) gas mixture as compared with room air during rigid bronchoscopy. Study Design Crossover animal study evaluating physiologic parameters during rigid bronchoscopy. Outcomes were compared with predicted computational fluid analysis. Setting Simulated ventilation via computational fluid dynamics analysis and term lambs undergoing rigid bronchoscopy. Methods Respiratory and physiologic outcomes were analyzed in a lamb model simulating bronchoscopy during foreign body aspiration to compare heliox with room air. The main outcome measures were blood oxygen saturation, heart rate, blood pressure, partial pressure of oxygen, and partial pressure of carbon dioxide. Computational fluid dynamics analysis was performed with SOLIDWORKS within a rigid pediatric bronchoscope during simulated ventilation comparing heliox with room air. Results For room air, lambs desaturated within 3 minutes during mechanical ventilation versus normal oxygen saturation during spontaneous ventilation ( P = .01). No improvement in respiratory outcomes was seen between heliox and room air during mechanical ventilation. Computational fluid dynamics analysis demonstrates increased turbulence within size 3.5 bronchoscopes when comparing heliox and room air. Meaningful comparisons could not be made due to the intolerance of the lambs to heliox in vivo. Conclusion During mechanical ventilation on room air, lambs desaturate more quickly during rigid bronchoscopy on settings that should be adequate. Heliox does not improve ventilation during rigid bronchoscopy.


Asunto(s)
Broncoscopía , Helio/farmacología , Oxígeno/farmacología , Respiración Artificial , Respiración/efectos de los fármacos , Animales , Animales Recién Nacidos , Bronquios , Diseño Asistido por Computadora , Estudios Cruzados , Femenino , Cuerpos Extraños/cirugía , Masculino , Ovinos
4.
J Surg Res ; 206(2): 316-324, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27884325

RESUMEN

BACKGROUND: The increasing incidence of healthcare-associated infections (HAIs) and multidrug-resistant organisms demonstrate the need for innovative technological solutions. Staphylococcus aureus, Streptococcus pneumonia, Escherichia coli, and Pseudomonas aeruginosa in particular are common pathogens responsible for a large percentage of indwelling medical device-associated clinical infections. The bactericidal effects of visible light sterilization (VLS) using 405-nm is one potential therapeutic under investigation. MATERIALS AND METHODS: Light-emitting diodes of 405-nm were used to treat varying concentrations of S aureus, S pneumonia, E coli, and P aeruginosa. Irradiance levels between 2.71 ± 0.20 to 9.27 ± 0.36 mW/cm2 and radiant exposure levels up to 132.98 ± 6.68 J/cm2 were assessed. RESULTS: Dose-dependent effects were observed in all species. Statistically significant reductions were seen in both Gram-positive and Gram-negative bacteria. At the highest radiant exposure levels, bacterial log10 reductions were E coli-6.27 ± 0.54, S aureus-6.10 ± 0.60, P aeruginosa-5.20 ± 0.84, and S pneumoniae-6.01 ± 0.59. Statistically significant results (<0.001*) were found at each time point. CONCLUSIONS: We have successfully demonstrated high-efficacy bacterial reduction using 405-nm light sterilization. The VLS showed statistical significance against both Gram-positive and Gram-negative species with the given treatment times. The ß-lactam antibiotic-resistant E coli was the most sensitive to VLS, suggesting light therapy could a suitable option for sterilization in drug-resistant bacterial species. This research illustrates the potential of using VLS in treating clinically relevant bacterial infections.


Asunto(s)
Infección Hospitalaria/prevención & control , Escherichia coli/efectos de la radiación , Luz , Pseudomonas aeruginosa/efectos de la radiación , Staphylococcus aureus/efectos de la radiación , Esterilización/métodos , Streptococcus pneumoniae/efectos de la radiación , Humanos
5.
Laryngoscope ; 126(8): 1940-5, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26422815

RESUMEN

OBJECTIVES/HYPOTHESIS: Observed complications during rigid bronchoscopy, including hypercarbia and hypoxemia, prompted us to assess how well rigid bronchoscopes serve as an airway device. We performed computer-aided design flow analysis of pediatric rigid bronchoscopes to gain insight into flow dynamics. STUDY DESIGN: We made accurate three-dimensional computer models of pediatric rigid bronchoscopes and endotracheal tubes. SOLIDWORKS (Dassault Systemes, Vélizy-Villacoublay, France) flow analysis software was used to analyze fluid dynamics during pressure-controlled and volume-controlled ventilation. METHODS: Flow analysis was performed on rigid bronchoscopes and similar outer diameter endotracheal tubes comparing resistance, flow, and turbulence during two ventilation modalities and in common surgical scenarios. RESULTS: Increased turbulent flow was observed in bronchoscopes compared to more laminar flow in endotracheal tubes of similar outer diameter. Flow analysis displayed higher resistances in all pediatric bronchoscope sizes except one (3.0 bronchoscope) compared to similar-sized endotracheal tubes. Loss of adequate ventilation was observed if the bronchoscope was not assembled correctly or if increased peak inspiratory pressures were needed. Anesthesia flow to the patient was reduced by 63% during telescope insertion. CONCLUSIONS: Flow analysis illustrates increased turbulent flow and increased airflow resistance in all but one size of pediatric bronchoscopes compared to endotracheal tubes. This increased turbulence and resistance, along with the unanticipated gas distal exit pattern, may contribute to the documented hypercarbia and hypoxemia during procedures. These findings may explain why hypoxemia and hypercarbia are commonly observed during rigid bronchoscopy, especially when positive pressure ventilation is needed. LEVEL OF EVIDENCE: NA Laryngoscope, 126:1940-1945, 2016.


Asunto(s)
Broncoscopios , Diseño Asistido por Computadora , Intubación Intratraqueal/instrumentación , Respiración Artificial , Programas Informáticos , Broncoscopía , Diseño de Equipo , Humanos , Respiración Artificial/métodos
6.
Lasers Surg Med ; 48(3): 311-7, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26711625

RESUMEN

BACKGROUND AND OBJECTIVE: Approximately 1.7 million patients are affected by hospital-acquired infections every year in the United States. The increasing prevalence of multidrug-resistant bacteria associated with these infections prompts the investigation of alternative sterilization and antibacterial therapies. One method currently under investigation is the antibacterial properties of visible light. This study examines the effect of a visible light therapy (VLT) on ß-lactam-resistant Escherichia coli, a common non-skin flora pathogen responsible for a large percentage of indwelling medical device-associated clinical infection. MATERIALS AND METHODS: 405 nm light-emitting diodes were used to treat varying concentrations of a common laboratory E. coli K-12 strain transformed with the pCIG mammalian expression vector. This conferred ampicillin resistance via expression of the ß-lactamase gene. Bacteria were grown on sterile polystyrene Petri dishes plated with Luria-Bertani broth. Images of bacterial growth colonies on plates were processed and analyzed using ImageJ. Irradiance levels between 2.89 ± 0.19 and 9.45 ± 0.63 mW cm(-2) and radiant exposure levels between 5.60 ± 0.39 and 136.91 ± 4.06 J cm(-2) were tested. RESULTS: VLT with variable irradiance and constant treatment time (120 minutes) demonstrated significant reduction (P < 0.001) in E. coli between an irradiance of 2.89 mW cm(-2) (81.70%) and 9.37 mW cm(-2) (100.00%). Similar results were found with variable treatment time with constant irradiance. Log10 reduction analysis produced between 1.98 ± 0.53 (60 minute treatment) and 6.27 ± 0.54 (250 minute treatment) log10 reduction in bacterial concentration (P < 0.001). CONCLUSIONS: We have successfully demonstrated a significant bacterial reduction using high intensity 405 nm light. Illustrating the efficacy of this technology against a ß-lactam-resistant E. coli is especially relevant to the need for novel methods of sterilization in healthcare settings. These results suggest that VLT using 405 nm light could be a suitable clinical option for eradication of ß-lactam-resistant E. coli. Visible light kills statistically significant concentrations of E. coli. Antibiotic-resistant Gram-negative bacteria exhibits sensitivity to 405 nm light. Greater than 6 log10 reduction in ß-lactam-resistant E. coli when treated with visible light therapy.


Asunto(s)
Desinfección/métodos , Farmacorresistencia Bacteriana/efectos de la radiación , Escherichia coli K12/efectos de la radiación , Luz , Antibacterianos/farmacología , Escherichia coli K12/efectos de los fármacos , Escherichia coli K12/crecimiento & desarrollo , beta-Lactamas/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...