1.
Mol Biol (Mosk) ; 52(6): 997-1005, 2018.
Artículo en Ruso | MEDLINE | ID: mdl-30633242

RESUMEN

A genotyping procedure based on single-step PCR and subsequent allele-specific hybridization on a hydrogel biochip was developed to address the polymorphisms of HERC2, OCA2, SLC24A4, SLC45A2, TYR, IRF4, MC1R,MITF, PIGU, MYH7B, NCOA6, and CDK10. Amplified gene fragments were fluorescently labeled in PCR, and fluorescent signals from biochip cells were detected to evaluate how efficiently the PCR product formed a perfect duplex with an immobilized probe. The analytical characteristics of hybridization analysis were estimated for several fluorophores with different optical spectra. Cyanine dyes fluorescing in the range of Cy5 and Cy7 were synthesized for the purpose and used as 5'-tags of universal primers in single-step PCR. A Cy7 analog fluorescing in the near infrared range was found to increase the sensitivity of hybridization analysis by producing a lower background signal in the cases where target gene amplification was low.


Asunto(s)
Técnicas de Genotipaje , Melanoma/genética , Alelos , Cartilla de ADN , Humanos , Reacción en Cadena de la Polimerasa , Polimorfismo Genético , Factores de Riesgo
2.
Mol Biol (Mosk) ; 49(5): 760-9, 2015.
Artículo en Ruso | MEDLINE | ID: mdl-26510593

RESUMEN

To expand the informational capabilities of molecular genetic research, on the biological microchips, new indotricarbocyanine dyes that fluoresce in the near infrared (IR) spectral region have been synthesized. The developed IR dyes were studied using a biochip-based test system for detection of mutations in the BRCA1/BRCA2 and CHECK2 genes associated with breast cancer. The fluorescent label was introduced to the analyzed DNA during PCR using primers labeled with the synthesized IR dyes. An analyzer that allows recording and processing of images of fluorescent microarrays in the IR spectral region was designed and manufactured. It has been shown that the use of the synthesized dyes enables to conduct analysis in the IR region and improve the reliability of medical diagnostic tests due to low fluorescence intensity of sample components as well as of a biochip substrate and the reagents used for analysis.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Carbocianinas/síntesis química , Colorantes Fluorescentes/síntesis química , Análisis por Micromatrices/métodos , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Proteína BRCA1/genética , Proteína BRCA1/metabolismo , Proteína BRCA2/genética , Proteína BRCA2/metabolismo , Neoplasias de la Mama/genética , Neoplasias de la Mama/patología , Carbocianinas/metabolismo , Quinasa de Punto de Control 2/genética , Quinasa de Punto de Control 2/metabolismo , Cartilla de ADN/síntesis química , Cartilla de ADN/genética , Femenino , Colorantes Fluorescentes/metabolismo , Expresión Génica , Humanos , Rayos Infrarrojos , Dispositivos Laboratorio en un Chip , Análisis por Micromatrices/instrumentación , Mutación , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , Reacción en Cadena de la Polimerasa/métodos
3.
Biofizika ; 60(6): 1198-202, 2015.
Artículo en Ruso | MEDLINE | ID: mdl-26841517

RESUMEN

The aim of this work was to compare different speckle reduction techniques. It was shown that the use of devices based on liquid crystals only leads to partial reduction of speckle contrast. In quantitative luminescent microscopy an application of the mechanical devices when a laser beam is spread within the field of view turned out to be more efficient. Laser speckle noise was virtually eliminated with the developed and manufactured mechanical device comprising a fiber optic ring light guide and the vibrator that permits movement of optical fiber ends towards the laser diode during measurements. The method developed for the analysis of microarrays was successfully applied to the problem of speckle reduction.


Asunto(s)
Biofisica , Rayos Láser , Luminiscencia , Microscopía/métodos , Luz , Óptica y Fotónica
4.
Biofizika ; 60(6): 1216-8, 2015.
Artículo en Ruso | MEDLINE | ID: mdl-26841520

RESUMEN

In order to study the effect of an electrical charge of the chromophore, on the efficiency of incorporation of fluorescently-labeled nucleotides into DNA during PCR, three fluorescently-labeled dUPT, one of which with electroneutral and other two with positively and negatively charged dyes (Cy5 analogs), were synthesized. It is shown that dUPT, labeled with electroneutral Cy 5 analog, is most effectively incorporated into DNA when Tag polymerase is used for PCR.


Asunto(s)
ADN/química , Nucleótidos/química , Reacción en Cadena de la Polimerasa/métodos , ADN/aislamiento & purificación , Colorantes Fluorescentes/química , Polimerasa Taq/química
5.
J Biomol Struct Dyn ; 24(1): 57-66, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16780376

RESUMEN

The optimal design of oligonucleotide microchips and efficient discrimination between perfect and mismatch duplexes strongly depend on the external transport of target DNA to the cells with immobilized probes as well as on respective association and dissociation rates at the duplex formation. In this paper we present the relevant theory for hybridization of DNA fragments with oligonucleotide probes immobilized in the cells on flat substrate. With minor modifications, our theory also is applicable to reaction-diffusion hybridization kinetics for the probes immobilized on the surface of microbeads immersed in hybridization solution. The main theoretical predictions are verified with control experiments. Besides that, we compared the characteristics of the surface and gel-based oligonucleotide microchips. The comparison was performed for the chips printed with the same pin robot, for the signals measured with the same devices and processed by the same technique, and for the same hybridization conditions. The sets of probe oligonucleotides and the concentrations of probes in respective solutions used for immobilization on each platform were identical as well. We found that, despite the slower hybridization kinetics, the fluorescence signals and mutation discrimination efficiency appeared to be higher for the gel-based microchips with respect to their surface counterparts even for the relatively short hybridization time about 0.5-1 hour. Both the divergence between signals for perfects and the difference in mutation discrimination efficiency for the counterpart platforms rapidly grow with incubation time. In particular, for hybridization during 3 h the signals for gel-based microchips surpassed their surface counterparts in 5-20 times, while the ratios of signals for perfect-mismatch pairs for gel microchips exceeded the corresponding ratios for surface microchips in 2-4 times. These effects may be attributed to the better immobilization efficiency and to the higher thermodynamic association constants for duplex formation within gel pads.


Asunto(s)
Hibridación de Ácido Nucleico , Análisis de Secuencia por Matrices de Oligonucleótidos , Electroforesis , Cinética , Análisis de Secuencia por Matrices de Oligonucleótidos/estadística & datos numéricos
6.
Biotechniques ; 34(5): 1008-14, 1016-20, 1022, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12765028

RESUMEN

Here a simple, reproducible, and versatile method is described for manufacturing protein and ligand chips. The photo-induced copolymerization of acrylamide-based gel monomers with different probes (oligonucleotides, DNA, proteins, and low-molecular ligands) modified by the introduction of methacrylic groups takes place in drops on a glass or silicone surface. All probes are uniformly and chemically fixed with a high yield within the whole volume of hydrogel semispherical chip elements that are chemically attached to the surface. Purified enzymes, antibodies, antigens, and other proteins, as well as complex protein mixtures such as cell lysates, were immobilized on a chip. Avidin- and oligohistidine-tagged proteins can be immobilized within biotin- and Ni-nitrilotriacetic acid-modified gel elements. Most gel-immobilized proteins maintain their biological properties for at least six months. Fluorescence and chemiluminescence microscopy were used as efficient methods for the quantitative analysis of the microchips. Direct on-chip matrix-assisted laser desorption ionization-time of flight mass spectrometry was used for the qualitative identification of interacting molecules and to analyze tryptic peptides after the digestion of proteins in individual gel elements. We also demonstrate other useful properties of protein microchips and their application to proteomics and diagnostics.


Asunto(s)
Hidrogeles , Análisis por Matrices de Proteínas/instrumentación , Análisis por Matrices de Proteínas/métodos , Proteínas/análisis , Proteínas/clasificación , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Fluorescencia/instrumentación , Espectrometría de Fluorescencia/métodos
7.
Appl Environ Microbiol ; 67(2): 922-8, 2001 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11157263

RESUMEN

We have developed a three-component system for microbial identification that consists of (i) a universal syringe-operated silica minicolumn for successive DNA and RNA isolation, fractionation, fragmentation, fluorescent labeling, and removal of excess free label and short oligonucleotides; (ii) microarrays of immobilized oligonucleotide probes for 16S rRNA identification; and (iii) a portable battery-powered device for imaging the hybridization of fluorescently labeled RNA fragments with the arrays. The minicolumn combines a guanidine thiocyanate method of nucleic acid isolation with a newly developed hydroxyl radical-based technique for DNA and RNA labeling and fragmentation. DNA and RNA can also be fractionated through differential binding of double- and single-stranded forms of nucleic acids to the silica. The procedure involves sequential washing of the column with different solutions. No vacuum filtration steps, phenol extraction, or centrifugation is required. After hybridization, the overall fluorescence pattern is captured as a digital image or as a Polaroid photo. This three-component system was used to discriminate Escherichia coli, Bacillus subtilis, Bacillus thuringiensis, and human HL60 cells. The procedure is rapid: beginning with whole cells, it takes approximately 25 min to obtain labeled DNA and RNA samples and an additional 25 min to hybridize and acquire the microarray image using a stationary image analysis system or the portable imager.


Asunto(s)
Bacillus subtilis/clasificación , Bacillus thuringiensis/clasificación , Escherichia coli/clasificación , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Bacillus subtilis/genética , Bacillus thuringiensis/genética , ADN Bacteriano/aislamiento & purificación , Escherichia coli/genética , Células HL-60 , Humanos , Hibridación de Ácido Nucleico , ARN Bacteriano/aislamiento & purificación , Dióxido de Silicio
8.
Genet Anal ; 14(1): 21-3, 1997 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-9158962

RESUMEN

We demonstrate that micro-dissection can be used for isolating NotI linking clones from the human 3p21-pter region. This approach is an improvement to positional cloning techniques, since NotI linking clones are directly linked with genes.


Asunto(s)
Carcinoma de Células Renales/genética , Carcinoma de Células Pequeñas/genética , Clonación Molecular/métodos , Micromanipulación/métodos , Secuencia de Bases , Deleción Cromosómica , Mapeo Cromosómico/métodos , Cromosomas Humanos Par 3 , Desoxirribonucleasas de Localización Especificada Tipo II , Humanos , Datos de Secuencia Molecular
9.
Cytometry ; 5(4): 348-54, 1984 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-6468175

RESUMEN

A technique for DNA amount determination by flow cytometry based on the use of 7-amino-actinomycin D (7-amino-AMD), a fluorescent analogue of antibiotic actinomycin has been investigated, and a particular staining procedure has been developed. The procedure includes short fixation in 70% ethanol and staining for 20 min in 10(-5)M solution of 7-amino-AMD at pH7. The results of DNA content measurements are very reproducible. The histograms obtained have a coefficient of variation less than 3%. The absorption maximum of the complex of 7-amino-AMD with DNA is situated in the green spectrum region, making this stain particularly suitable for argon laser flow cytometry.


Asunto(s)
ADN/análisis , Dactinomicina/análogos & derivados , Animales , Cromosomas/ultraestructura , ADN/sangre , Drosophila , Citometría de Flujo/métodos , Colorantes Fluorescentes , Rayos Láser , Hígado/citología , Linfocitos/citología , Ratones , Glándulas Salivales/citología
10.
Chromosoma ; 81(4): 619-28, 1981.
Artículo en Inglés | MEDLINE | ID: mdl-6790245

RESUMEN

The majority of D. melanogaster salivary gland nuclei contains many nucleoli which vary in size and number. All nucleoli hybridize in situ with a cloned Drosophila DNA fragment containing 26S ribosomal gene. Autoradiographic analysis of preparations after pulse H3-uridine or H3-thymidine labelling of the salivary gland indicates an intensive transcription and replication of DNA within nucleoli. The nucleoli are bound to different sites of polytene chromosomes by chromatin fibers similar to strands of ectopic pairing and they are most often bound to regions which may be defined as intercalary heterochromatin.


Asunto(s)
Nucléolo Celular/ultraestructura , Cromosomas/ultraestructura , Drosophila melanogaster/genética , Animales , Autorradiografía , Nucléolo Celular/metabolismo , ADN/genética , Hibridación de Ácido Nucleico , Glándulas Salivales/ultraestructura , Transcripción Genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA