Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Europace ; 14(9): 1340-3, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22447957

RESUMEN

AIMS: Isthmus-dependent (ID) clockwise (CW) atrial flutters (AFl) are rare in comparison with counterclockwise (CCW) AFl. Little is known about clinical and electrophysiological characteristics of CW AFl occurring after previous radiofrequency (RF) catheter ablation of CCW AFl. We sought to compare CW AFl de novo vs. CW AFl occurring after previous CCW AFl RF ablation. METHODS AND RESULTS: A total of 246 procedures of RF catheter ablation for AFl from January 2009 to January 2011 were reviewed. Clinical and electrophysiological data were analysed. Patients were excluded if they were in sinus rhythm at the beginning of the procedure, if they had concomitant/previous atrial fibrillation ablation, or if AFl was not ID. Twenty-seven patients presented CW AFl (10.9% of all ID AFl), including 10 CW AFl occurring after a previous RF catheter ablation for CCW AFl. Mean time for recurrence after the previous procedure of CCW AFl RF ablation was 3.5 years. They were younger (61.6 ± 11 years) than patients with CW AFl de novo (74.0 ± 7.2 years; P = 0.005). Bidirectional isthmus block was obtained in all patients. There was a significant difference in terms of double potential separation after ablation (155 ± 31 ms for CW AFl de novo vs. 111 ± 7 ms for recurrent CW AFl; P = 0.028). No differences were observed concerning CHADS score, AFl cycle length, and electrocardiogram typical pattern for CW AFl between the two groups. CONCLUSION: Patients with CW AFl occurrence after CCW AFl RF catheter ablation are younger than patients with CW AFl de novo. They also have a smaller interspike interval after block completion.


Asunto(s)
Aleteo Atrial/cirugía , Ablación por Catéter , Anciano , Anciano de 80 o más Años , Aleteo Atrial/fisiopatología , Electrocardiografía , Femenino , Bloqueo Cardíaco/diagnóstico , Bloqueo Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos
2.
JACC Cardiovasc Imaging ; 3(7): 673-81, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20633844

RESUMEN

OBJECTIVES: We sought to determine the incidence, diagnostic value, and outcome of intracardiac masses observed by echocardiography after device removal. We hypothesized that these "ghosts" of leads could be associated with the diagnosis of cardiac device-related infective endocarditis (CDRIE). BACKGROUND: The echocardiographic appearance of residual floating masses in the right atrium after removal of permanent pacemakers and implantable cardioverter-defibrillators was recently described. However, the significance of these ghosts and their relationship with CDRIE are unknown. METHODS: The pre-operative clinical, microbiological, and echocardiographic conditions; the indication; and the removal technique were analyzed in a retrospective cohort including all consecutive patients who underwent percutaneous lead removal. Three groups were formed according to the final diagnosis: CDRIE, local device infection, and noninfectious indications. The incidence of ghosts was compared among the 3 groups. All clinical, infectious, and extraction-related factors were studied for their association with ghosts. All patients with ghosts were followed after hospitalization. RESULTS: Two hundred twelve patients underwent lead removal. Ghosts were observed in 17 patients (8% incidence), including 14 (16%) of 88 patients with CDRIE and 3 (5%) of 59 patients with local device infection. Ghosts were never observed among the remaining 65 noninfected patients. A significant association was found between CDRIE and the presence of a ghost (odds ratio: 7.63, 95% confidence interval: 2.12 to 27.45, p = 0.001). At 3 months, 2 patients with ghosts died suddenly, 2 underwent surgery, and 1 had a pulmonary embolism. CONCLUSIONS: Ghosts are observed in 8% of patients after percutaneous device extraction. Their presence is suggestive of device infection and seems to be associated with the diagnosis of CDRIE. The prognostic significance of such findings needs further investigation.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Ecocardiografía Transesofágica , Endocarditis/diagnóstico por imagen , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Endocarditis/epidemiología , Endocarditis/microbiología , Endocarditis/terapia , Femenino , Francia , Humanos , Incidencia , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Valor Predictivo de las Pruebas , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/terapia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
3.
Europace ; 11 Suppl 5: v29-31, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19861388

RESUMEN

Cardiac resynchronization therapy (CRT) is an effective treatment of heart failure in selected patients. However, with conventional CRT, notable left ventricular (LV) reverse remodelling is achieved in only 60-70% of patients. This lack of effect of CRT might be due to incomplete resynchronization. In some patients, the paced activation front arising from a single LV electrode is unfavourable, possibly resulting in suboptimal resynchronization. Dual-site LV CRT has theoretical advantages in faster and more physiological LV activation. Some clinical evidence supports dual LV pacing. Nevertheless, a clear benefit of this pacing modality in patients chronically implanted is still unproved. A randomized study comparing single- and dual-site LV pacing, the Triple-Site Cardiac Resynchronization study of Patients with Heart Failure (TRUST CRT) is still ongoing.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial , Disfunción Ventricular Izquierda/terapia , Electrodos Implantados , Humanos , Contracción Miocárdica/fisiología , Disfunción Ventricular Izquierda/fisiopatología , Remodelación Ventricular/fisiología
4.
J Am Coll Cardiol ; 53(23): 2168-74, 2009 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-19497444

RESUMEN

OBJECTIVES: This study sought to evaluate the incidence, risk factors, and outcome of traumatic tricuspid regurgitation (TTR) induced by percutaneous removal of chronically implanted transvenous leads. BACKGROUND: Although lead removal using modern tools has been shown to be highly effective and safe, TTR has not been systematically evaluated. METHODS: All patients undergoing ventricular lead removal at our center were studied. Lead removal was performed by simple traction, laser sheath, and/or lasso technique. Presence of a new TTR after removal was assessed by transthoracic echocardiography. Pre-defined clinical and technical parameters were studied for their association with TTR. Patients were followed up by outpatient visits. RESULTS: We removed 237 ventricular leads in 208 patients. Median time from lead implantation was 46.4 months (range 0.7 to 260.5 months). A TTR occurred in 19 patients (9.1%), severe in 14. Three independent risk factors of TTR were found: use of laser sheath (p = 0.004), use of both laser sheath and lasso (p = 0.02), and female sex (p = 0.02). After a follow-up of 4,130 person-months (median 17.9 months), 5 TTR patients were medically treated for new right-sided heart failure symptoms, 2 had undergone surgical repair of the tricuspid valve, and 6 had died (2 from heart failure and 4 from noncardiac causes). Right-sided heart failure occurred only in patients with severe TTR. CONCLUSIONS: This study found that TTR is not uncommon after percutaneous lead removal. It is strongly associated with the use of additional tools beyond simple traction and also with female sex. In the long term, right-sided heart failure is frequent in patients with severe TTR.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/efectos adversos , Insuficiencia de la Válvula Tricúspide/etiología , Anciano , Intervalos de Confianza , Remoción de Dispositivos/instrumentación , Ecocardiografía , Ecocardiografía Transesofágica , Electrodos Implantados , Femenino , Ventrículos Cardíacos , Humanos , Incidencia , Masculino , Análisis Multivariante , Oportunidad Relativa , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/epidemiología
5.
Arch Cardiovasc Dis ; 102(2): 135-41, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19303581

RESUMEN

Clinical trials in patients with pacemakers for sinus node dysfunction or atrioventricular block have highlighted the fact that desynchronization of ventricular contraction induced by right ventricular apical pacing is associated with long-term morbidity and mortality. These clinical data confirm pathophysiological results indicating that right ventricular apical pacing causes abnormal ventricular contraction, reduces pump function and leads to myocardial hypertrophy and ultrastructural abnormalities. In this manuscript, we discuss the clinical evidence for the adverse and beneficial effects of various right ventricular pacing sites, left ventricular pacing sites and biventricular pacing. We also propose a decisional algorithm for pacing modalities, based on atrioventricular conduction, left ventricular function and expected lifespan.


Asunto(s)
Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/métodos , Algoritmos , Bloqueo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Medicina Basada en la Evidencia , Ventrículos Cardíacos/fisiopatología , Humanos , Contracción Miocárdica , Selección de Paciente , Medición de Riesgo , Nodo Sinoatrial/fisiopatología , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...