Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Diagn Microbiol Infect Dis ; 102(4): 115630, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35074622

RESUMEN

Some sera tested for 1-3-beta-D-glucan to identify invasive fungal infections exhibit interference. To assess interference transience, we evaluated results for 426 patients with an interference sample followed by a later sample. Interference was transient for 73% of patients (later sample negative or positive); median time between samples was 8 days.


Asunto(s)
Infecciones Fúngicas Invasoras , beta-Glucanos , Glucanos , Humanos , Inmunoensayo , Proteoglicanos
2.
Sex Transm Dis ; 49(5): 353-359, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35067597

RESUMEN

BACKGROUND: Our laboratory system tests sera for herpes simplex virus type 2 (HSV-2) IgG using the DiaSorin Liaison chemiluminescent immunoassay (CIA), with the option to confirm positive samples by a laboratory-developed HerpeSelect inhibition assay. As part of the confirmation process, the HerpeSelect HSV-2 IgG enzyme immunoassay (EIA) is performed. This study investigated the relationship between DiaSorin HSV-2 IgG CIA-positive indices and HerpeSelect HSV-2 IgG EIA results. METHODS: HerpeSelect HSV-2 IgG EIA results were compiled for a cohort of consecutive DiaSorin HSV-2 IgG CIA-positive (index ≥1.10) samples. To further characterize DiaSorin CIA-positive samples that were positive (concordant) or negative (discordant) by the HerpeSelect EIA, a separate composite reference study panel was constructed and also tested using the Biokit HSV-2 IgG assay and an HSV-2 IgG inhibition assay developed for the DiaSorin instrument. Samples were classified as DiaSorin HSV-2 IgG true positive or false positive based on a composite reference using HerpeSelect EIA, Biokit, and DiaSorin inhibition results. RESULTS: Of 2305 consecutive DiaSorin HSV-2 IgG CIA-positive samples, 411 (17.8%) were HerpeSelect HSV-2 IgG EIA negative; 343 of 411 (83%) had DiaSorin indices of 1.10 to 3.00. For the composite reference study panel (N = 120), 59 of 60 discordant samples were classified as DiaSorin HSV-2 IgG false positive based on the composite reference, whereas 58 of 60 concordant samples were classified as true positive. CONCLUSIONS: Nearly all DiaSorin HSV-2 IgG CIA-positive but HerpeSelect HSV-2 IgG EIA-negative sera are falsely positive in the DiaSorin CIA. Furthermore, most DiaSorin false-positive samples exhibit low-positive indices, suggesting that guidelines for confirmatory testing should include low-positive samples by CIA and EIA.


Asunto(s)
Herpes Genital , Herpes Simple , Anticuerpos Antivirales , Ensayo de Inmunoadsorción Enzimática/métodos , Femenino , Herpes Genital/diagnóstico , Herpes Simple/diagnóstico , Herpesvirus Humano 2 , Humanos , Inmunoglobulina G , Masculino , Sensibilidad y Especificidad
3.
J Clin Microbiol ; 58(11)2020 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-32817144

RESUMEN

A total of 1,200 serum samples that were tested for SARS-CoV-2 IgG antibody using the Abbott Architect immunoassay targeting the nucleocapsid protein were run in 3 SARS-CoV-2 IgG immunoassays targeting spike proteins (DiaSorin Liaison, Ortho Vitros, and Euroimmun). Consensus-positive and consensus-negative interpretations were defined as qualitative agreement in at least 3 of the 4 assays. Agreement of the 4 individual assays with a consensus-negative interpretation (n = 610) ranged from 96.7% to 100%, and agreement with a consensus-positive interpretation (n = 584) ranged from 94.3% to 100%. Laboratory-developed inhibition assays were utilized to evaluate 49 consensus-negative samples that were positive in only one assay; true-positive reactivity was confirmed in only 2 of these 49 (4%) samples. These findings demonstrate very high levels of agreement among 4 SARS-CoV-2 IgG assays authorized for emergency use, regardless of antigen target or assay format. Although false-positive reactivity was identified, its occurrence was rare (no more than 1.7% of samples for a given assay).


Asunto(s)
Infecciones por Coronavirus , Nucleocápside , Pandemias , Neumonía Viral , Coronavirus Relacionado al Síndrome Respiratorio Agudo Severo , Anticuerpos Antivirales , Betacoronavirus , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/diagnóstico , Humanos , Inmunoensayo , Inmunoglobulina G , SARS-CoV-2 , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus
4.
J Clin Microbiol ; 58(8)2020 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-32341141

RESUMEN

The global coronavirus (CoV) disease 2019 (COVID-19) pandemic has resulted in a worldwide shortage of viral transport media and raised questions about specimen stability. The objective of this study was to determine the stability of severe acute respiratory syndrome CoV 2 (SARS-CoV-2) RNA in specimen transport media under various storage conditions. Transport media tested included UTM, UTM-RT, ESwab, M4, and saline (0.9% NaCl). Specimen types tested included nasopharyngeal/oropharyngeal swabs in the above-named transport media, bronchoalveolar lavage (BAL) fluid, and sputum. A high-titer SARS-CoV-2 remnant patient specimen was spiked into pooled SARS-CoV-2 RNA-negative specimen remnants for the various medium types. Aliquots of samples were stored at 18°C to 26°C, 2°C to 8°C, and -10°C to -30°C and then tested at time points up to 14 days. Specimens consistently yielded amplifiable RNA with mean cycle threshold differences of <3 over the various conditions assayed, thus supporting the use and transport of alternative collection media and specimen types under a variety of temperature storage conditions.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Químicos de Laboratorio/química , Neumonía Viral/diagnóstico , Manejo de Especímenes/métodos , COVID-19 , Prueba de COVID-19 , Humanos , Pandemias , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2 , Temperatura
5.
Diagn Microbiol Infect Dis ; 95(3): 114864, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31395403

RESUMEN

CDC guidelines recommend confirmatory testing of sera with low-positive indices (1.10-3.50) in the HerpeSelect® (HSLT) HSV-2 IgG screening assay. To determine if this recommendation is adequate for our patient population, we reviewed HSLT HSV-2 IgG screening indices for 262 screen-positive sera (index >1.10) tested in our confirmatory assay, which assesses inhibition of binding to recombinant gG2 by HSV-1- and HSV-2-infected cell lysates. To determine how the recommendation affects other screening assays, we tested these samples in the Liaison® HSV-2 IgG assay. Of 124 false-positive sera, 20% and 39% had an index >3.50 in the HSLT and Liaison screening assays, respectively. In both assays, 51% of 63 indeterminate sera (inhibition by HSV-1 lysate) had indices >3.50. Similarly, ≥75% of 75 true-positive samples exhibited indices >3.50 in both assays. Thus, confirmatory testing only of sera with low-positive HSV-2 IgG indices misses some false-positive and indeterminate samples, leading to misdiagnosis of HSV-2 infection.


Asunto(s)
Herpes Genital/diagnóstico , Herpesvirus Humano 2/aislamiento & purificación , Inmunoensayo/normas , Pruebas Serológicas/normas , Anticuerpos Antivirales/sangre , Reacciones Falso Positivas , Herpesvirus Humano 1/inmunología , Herpesvirus Humano 2/inmunología , Humanos , Inmunoglobulina G/sangre , Proteínas del Envoltorio Viral/inmunología
6.
Epidemiol Infect ; 146(10): 1240-1244, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29941056

RESUMEN

The objective of this study was to provide real-world clinical laboratory-based data to supplement Centers for Disease Control and Prevention (CDC) reporting of Q fever. We analysed titre results of specimens submitted to a large US clinical laboratory for Coxiella burnetii IgG antibody testing from 2010 through 2016. Presumptive Q fever was defined as acute (phase II IgG titre ⩾1:128, phase I titre <1:1024) or chronic (phase I IgG titre ⩾1:1024), based on the results from a single serum specimen. During 2010-2016, an average of 328 presumptive acute Q fever cases were identified at Quest each year, nearly three times the annual average reported to the CDC (122). During the same period, the number of chronic cases identified annually at Quest Diagnostics (34) was similar to that reported to the CDC (29). These findings suggest that CDC data may underestimate the incidence of acute Q fever.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Coxiella burnetii/inmunología , Inmunoglobulina G/sangre , Fiebre Q/diagnóstico , Fiebre Q/epidemiología , Enfermedad Aguda , Anciano , Enfermedad Crónica , Notificación de Enfermedades , Monitoreo Epidemiológico , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Fiebre Q/sangre , Estudios Seroepidemiológicos , Estados Unidos/epidemiología
7.
Transpl Infect Dis ; 19(1)2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27925350

RESUMEN

We present a case of JC polyomavirus (JCV)-associated nephropathy (PyVAN) in an asymptomatic deceased-donor kidney transplant recipient. Despite the presence of viral cytopathic effect in the kidney biopsy and positive BK polyomavirus (BKV) in situ hybridization (ISH), BKV real-time polymerase chain reaction (PCR) results of plasma and urine were negative. JCV ISH was performed and was found to be positive. JCV real-time PCR on urine, plasma, and the kidney biopsy tissue was positive. Reduction in immunosuppression resulted in resolution of JCV viremia. This case highlights that JC-PyVAN is a distinct clinical entity and is likely to have a better clinical outcome than BK-PyVAN. Concurrent infection with BKV and JCV may occur, but may be difficult to confirm due to the potential for cross-reactivity between BKV and JCV ISH stains.


Asunto(s)
ADN Viral/aislamiento & purificación , Virus JC/aislamiento & purificación , Enfermedades Renales/diagnóstico , Trasplante de Riñón/efectos adversos , Infecciones por Polyomavirus/diagnóstico , Infecciones Tumorales por Virus/diagnóstico , Viremia/virología , Suero Antilinfocítico/administración & dosificación , Suero Antilinfocítico/efectos adversos , Suero Antilinfocítico/uso terapéutico , Virus BK/aislamiento & purificación , Biopsia , Femenino , Humanos , Terapia de Inmunosupresión/efectos adversos , Inmunosupresores/administración & dosificación , Inmunosupresores/efectos adversos , Inmunosupresores/uso terapéutico , Hibridación in Situ , Riñón/patología , Enfermedades Renales/patología , Enfermedades Renales/virología , Fallo Renal Crónico/cirugía , Persona de Mediana Edad , Infecciones por Polyomavirus/patología , Infecciones por Polyomavirus/virología , Reacción en Cadena en Tiempo Real de la Polimerasa , Receptores de Trasplantes , Infecciones Tumorales por Virus/patología , Infecciones Tumorales por Virus/virología
8.
Expert Rev Mol Diagn ; 16(3): 269-76, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26679835

RESUMEN

The Simplexa™ Group A Strep Direct assay is intended for use on the Integrated Cycler for detection of Group A Streptococcus (GAS) directly from throat swabs that have not undergone nucleic acid extraction. A prospective study of 1352 samples in 4 geographically diverse sites showed an overall prevalence of GAS of 15.4%. The assay demonstrated 97.4% sensitivity and 95.2% specificity versus culture. The positive predictive value compared to culture was 72.7%. However, 46 out of 57 discrepant samples were Group A Strep positive when tested using a bi-directional sequencing method illustrating the increased sensitivity of the assay compared to culture for detection of GAS. Rapid and accurate diagnosis of GAS allows for timely treatment to decrease complications of this prevalent organism that continues to cause substantial morbidity and mortality worldwide.


Asunto(s)
Técnicas de Diagnóstico Molecular/métodos , Faringitis/diagnóstico , Infecciones Estreptocócicas/diagnóstico , Streptococcus pyogenes/aislamiento & purificación , Humanos , Técnicas de Diagnóstico Molecular/instrumentación , Faringitis/microbiología , Reacción en Cadena de la Polimerasa/instrumentación , Reacción en Cadena de la Polimerasa/métodos , Sensibilidad y Especificidad , Streptococcus pyogenes/genética
9.
Clin Vaccine Immunol ; 22(3): 291-7, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25540275

RESUMEN

Since first reported in the Americas in December 2013, chikungunya virus (CHIKV) infections have been documented in travelers returning from the Caribbean, with many cases identified by CHIKV antibody and/or RNA testing at our laboratory. We used our large data set to characterize the relationship between antibody titers and RNA detection and to estimate IgM persistence. CHIKV RNA was measured by nucleic acid amplification and CHIKV IgG/IgM by indirect immunofluorescence. Of the 1,306 samples submitted for RNA testing in January through September 2014, 393 (30%) were positive; for 166 RNA-positive samples, CHIKV antibody testing was also ordered, and 84% were antibody negative. Of the 6,971 sera submitted for antibody testing in January through September 2014, 1,811 (26%) were IgM positive; 1,461 IgM positives (81%) were also IgG positive. The relationship between the CHIKV antibody titers and RNA detection was evaluated using 376 IgM-positive samples (138 with RNA testing ordered and 238 deidentified and tested for RNA). RNA detection showed no significant association with the IgM titer but was inversely related to the IgG titer; 63% of the IgG negative sera were RNA positive, compared to 36% of sera with low IgG titers (1:10 to 1:80) and 16% with IgG titers of ≥1:160. Using second-sample results from 62 seroconverters, we estimated that CHIKV IgM persists for 110 days (95% confidence interval, 78 to 150 days) after the initial antibody-negative sample. These findings indicate that (i) RNA detection is more sensitive than antibody detection early in CHIKV infection, (ii) in the absence of RNA results, the IgG titer of the IgM-positive samples may be a useful surrogate for viremia, and (iii) CHIKV IgM persists for approximately 4 months after symptom onset.


Asunto(s)
Anticuerpos Antivirales/sangre , Fiebre Chikungunya/diagnóstico , Virus Chikungunya/inmunología , Virus Chikungunya/aislamiento & purificación , ARN Viral , Américas/epidemiología , Virus Chikungunya/genética , Técnica del Anticuerpo Fluorescente Indirecta , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Pruebas Inmunológicas , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad , Viremia/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA