BACKGROUND: Kinetics of the uptake of inhaled anesthetics have been well studied, but the kinetics of elimination might be of more practical importance. The objective of the authors' study was to assess the effect of the overall ventilation/perfusion ratio (VA/Q), for normal lungs, on elimination kinetics of desflurane and sevoflurane. METHODS: The authors developed a mathematical model of inhaled anesthetic elimination that explicitly relates the terminal washout time constant to the global lung VA/Q ratio. Assumptions and results of the model were tested with experimental data from a recent study, where desflurane and sevoflurane elimination were observed for three different VA/Q conditions: normal, low, and high. RESULTS: The mathematical model predicts that the global VA/Q ratio, for normal lungs, modifies the time constant for tissue anesthetic washout throughout the entire elimination. For all three VA/Q conditions, the ratio of arterial to mixed venous anesthetic partial pressure Part/Pmv reached a constant value after 5 min of elimination, as predicted by the retention equation. The time constant corrected for incomplete lung clearance was a better predictor of late-stage kinetics than the intrinsic tissue time constant. CONCLUSIONS: In addition to the well-known role of the lungs in the early phases of inhaled anesthetic washout, the lungs play a long-overlooked role in modulating the kinetics of tissue washout during the later stages of inhaled anesthetic elimination. The VA/Q ratio influences the kinetics of desflurane and sevoflurane elimination throughout the entire elimination, with more pronounced slowing of tissue washout at lower VA/Q ratios.


Desflurane/pharmacokinetics , Lung/physiology , Models, Theoretical , Pulmonary Ventilation/physiology , Sevoflurane/pharmacokinetics , Ventilation-Perfusion Ratio/physiology , Anesthetics, Inhalation/administration & dosage , Anesthetics, Inhalation/pharmacokinetics , Animals , Animals, Newborn , Desflurane/administration & dosage , Female , Kinetics , Lung/drug effects , Male , Pulmonary Ventilation/drug effects , Sevoflurane/administration & dosage , Swine , Ventilation-Perfusion Ratio/drug effects
2.
Anesthesiology ; 135(6): 1027-1041, 2021 12 01.
Article En | MEDLINE | ID: mdl-34731241

BACKGROUND: Previous studies have established the role of various tissue compartments in the kinetics of inhaled anesthetic uptake and elimination. The role of normal lungs in inhaled anesthetic kinetics is less understood. In juvenile pigs with normal lungs, the authors measured desflurane and sevoflurane washin and washout kinetics at three different ratios of alveolar minute ventilation to cardiac output value. The main hypothesis was that the ventilation/perfusion ratio (VA/Q) of normal lungs influences the kinetics of inhaled anesthetics. METHODS: Seven healthy pigs were anesthetized with intravenous anesthetics and mechanically ventilated. Each animal was studied under three different VA/Q conditions: normal, low, and high. For each VA/Q condition, desflurane and sevoflurane were administered at a constant, subanesthetic inspired partial pressure (0.15 volume% for sevoflurane and 0.5 volume% for desflurane) for 45 min. Pulmonary arterial and systemic arterial blood samples were collected at eight time points during uptake, and then at these same times during elimination, for measurement of desflurane and sevoflurane partial pressures. The authors also assessed the effect of VA/Q on paired differences in arterial and mixed venous partial pressures. RESULTS: For desflurane washin, the scaled arterial partial pressure differences between 5 and 0 min were 0.70 ± 0.10, 0.93 ± 0.08, and 0.82 ± 0.07 for the low, normal, and high VA/Q conditions (means, 95% CI). Equivalent measurements for sevoflurane were 0.55 ± 0.06, 0.77 ± 0.04, and 0.75 ± 0.08. For desflurane washout, the scaled arterial partial pressure differences between 0 and 5 min were 0.76 ± 0.04, 0.88 ± 0.02, and 0.92 ± 0.01 for the low, normal, and high VA/Q conditions. Equivalent measurements for sevoflurane were 0.79 ± 0.05, 0.85 ± 0.03, and 0.90 ± 0.03. CONCLUSIONS: Kinetics of inhaled anesthetic washin and washout are substantially altered by changes in the global VA/Q ratio for normal lungs.


Desflurane/administration & dosage , Desflurane/blood , Sevoflurane/administration & dosage , Sevoflurane/blood , Ventilation-Perfusion Ratio/physiology , Anesthetics, Inhalation/administration & dosage , Anesthetics, Inhalation/blood , Animals , Animals, Newborn , Arteries/drug effects , Drug Combinations , Female , Kinetics , Male , Swine , Veins/drug effects , Veins/physiology , Ventilation-Perfusion Ratio/drug effects
4.
Crit Care ; 23(1): 102, 2019 Mar 27.
Article En | MEDLINE | ID: mdl-30917851

BACKGROUND: Mechanical ventilation can lead to ventilator-induced lung injury (VILI). In addition to the well-known mechanical forces of volutrauma, barotrauma, and atelectrauma, non-mechanical mechanisms have recently been discussed as contributing to the pathogenesis of VILI. One such mechanism is oscillations in partial pressure of oxygen (PO2) which originate in lung tissue in the presence of within-breath recruitment and derecruitment of alveoli. The purpose of this study was to investigate this mechanism's possible independent effects on lung tissue and inflammation in a porcine model. METHODS: To separately study the impact of PO2 oscillations on the lungs, an in vivo model was set up that allowed for generating mixed-venous PO2 oscillations by the use of veno-venous extracorporeal membrane oxygenation (vvECMO) in a state of minimal mechanical stress. While applying the identical minimal-invasive ventilator settings, 16 healthy female piglets (weight 50 ± 4 kg) were either exposed for 6 h to a constant mixed-venous hemoglobin saturation (SmvO2) of 65% (which equals a PmvO2 of 41 Torr) (control group), or an oscillating SmvO2 (intervention group) of 40-90% (which equals PmvO2 oscillations of 30-68 Torr)-while systemic normoxia in both groups was maintained. The primary endpoint of histologic lung damage was assessed by ex vivo histologic lung injury scoring (LIS), the secondary endpoint of pulmonary inflammation by qRT-PCR of lung tissue. Cytokine concentration of plasma was carried out by ELISA. A bioinformatic microarray analysis of lung samples was performed to generate hypotheses about underlying pathomechanisms. RESULTS: The LIS showed significantly more severe damage of lung tissue after exposure to PO2 oscillations compared to controls (0.53 [0.51; 0.58] vs. 0.27 [0.23; 0.28]; P = 0.0025). Likewise, a higher expression of TNF-α (P = 0.0127), IL-1ß (P = 0.0013), IL-6 (P = 0.0007), and iNOS (P = 0.0013) in lung tissue was determined after exposure to PO2 oscillations. Cytokines in plasma showed a similar trend between the groups, however, without significant differences. Results of the microarray analysis suggest that inflammatory (IL-6) and oxidative stress (NO/ROS) signaling pathways are involved in the pathology linked to PO2 oscillations. CONCLUSIONS: Artificial mixed-venous PO2 oscillations induced lung damage and pulmonary inflammation in healthy animals during lung protective ventilation. These findings suggest that PO2 oscillations represent an independent mechanism of VILI.


Pneumonia/etiology , Ventilator-Induced Lung Injury/physiopathology , Animals , Disease Models, Animal , Enzyme-Linked Immunosorbent Assay/methods , Female , Germany , Oxygen/administration & dosage , Oxygen/adverse effects , Oxygen/therapeutic use , Partial Pressure , Pneumonia/pathology , Pneumonia/physiopathology , Respiration, Artificial/adverse effects , Respiration, Artificial/methods , Respiration, Artificial/standards , Respiratory Mechanics/physiology , Swine , Ventilator-Induced Lung Injury/etiology , Ventilator-Induced Lung Injury/pathology
6.
Crit Care ; 22(1): 50, 2018 Feb 24.
Article En | MEDLINE | ID: mdl-29475456

BACKGROUND: Cyclic recruitment and de-recruitment of atelectasis (c-R/D) is a contributor to ventilator-induced lung injury (VILI). Bedside detection of this dynamic process could improve ventilator management. This study investigated the potential of automated lung sound analysis to detect c-R/D as compared to four-dimensional computed tomography (4DCT). METHODS: In ten piglets (25 ± 2 kg), acoustic measurements from 34 thoracic piezoelectric sensors (Meditron ASA, Norway) were performed, time synchronized to 4DCT scans, at positive end-expiratory pressures of 0, 5, 10, and 15 cmH2O during mechanical ventilation, before and after induction of c-R/D by surfactant washout. 4DCT was post-processed for within-breath variation in atelectatic volume (Δ atelectasis) as a measure of c-R/D. Sound waveforms were evaluated for: 1) dynamic crackle energy (dCE): filtered crackle sounds (600-700 Hz); 2) fast Fourier transform area (FFT area): spectral content above 500 Hz in frequency and above -70 dB in amplitude in proportion to the total amount of sound above -70 dB amplitude; and 3) dynamic spectral coherence (dSC): variation in acoustical homogeneity over time. Parameters were analyzed for global, nondependent, central, and dependent lung areas. RESULTS: In healthy lungs, negligible values of Δ atelectasis, dCE, and FFT area occurred. In lavage lung injury, the novel dCE parameter showed the best correlation to Δ atelectasis in dependent lung areas (R2 = 0.88) where c-R/D took place. dCE was superior to FFT area analysis for each lung region examined. The analysis of dSC could predict the lung regions where c-R/D originated. CONCLUSIONS: c-R/D is associated with the occurrence of fine crackle sounds as demonstrated by dCE analysis. Standardized computer-assisted analysis of dCE and dSC seems to be a promising method for depicting c-R/D.


Inhalation/physiology , Monitoring, Physiologic/methods , Pulmonary Atelectasis/diagnosis , Respiration, Artificial/standards , Respiratory Sounds , Animals , Area Under Curve , Disease Models, Animal , Four-Dimensional Computed Tomography/methods , Lung/physiopathology , Monitoring, Physiologic/standards , Pulmonary Atelectasis/physiopathology , ROC Curve , Respiration, Artificial/methods , Swine , Ventilator-Induced Lung Injury/prevention & control
7.
Anesthesiology ; 127(5): 800-812, 2017 11.
Article En | MEDLINE | ID: mdl-28857808

BACKGROUND: Increasing numbers of patients with obstructive lung diseases need anesthesia for surgery. These conditions are associated with pulmonary ventilation/perfusion (VA/Q) mismatch affecting kinetics of volatile anesthetics. Pure shunt might delay uptake of less soluble anesthetic agents but other forms of VA/Q scatter have not yet been examined. Volatile anesthetics with higher blood solubility would be less affected by VA/Q mismatch. We therefore compared uptake and elimination of higher soluble isoflurane and less soluble desflurane in a piglet model. METHODS: Juvenile piglets (26.7 ± 1.5 kg) received either isoflurane (n = 7) or desflurane (n = 7). Arterial and mixed venous blood samples were obtained during wash-in and wash-out of volatile anesthetics before and during bronchoconstriction by methacholine inhalation (100 µg/ml). Total uptake and elimination were calculated based on partial pressure measurements by micropore membrane inlet mass spectrometry and literature-derived partition coefficients and assumed end-expired to arterial gradients to be negligible. VA/Q distribution was assessed by the multiple inert gas elimination technique. RESULTS: Before methacholine inhalation, isoflurane arterial partial pressures reached 90% of final plateau within 16 min and decreased to 10% after 28 min. By methacholine nebulization, arterial uptake and elimination delayed to 35 and 44 min. Desflurane needed 4 min during wash-in and 6 min during wash-out, but with bronchoconstriction 90% of both uptake and elimination was reached within 15 min. CONCLUSIONS: Inhaled methacholine induced bronchoconstriction and inhomogeneous VA/Q distribution. Solubility of inhalational anesthetics significantly influenced pharmacokinetics: higher soluble isoflurane is less affected than fairly insoluble desflurane, indicating different uptake and elimination during bronchoconstriction.


Anesthetics, Inhalation/blood , Bronchoconstriction/physiology , Isoflurane/analogs & derivatives , Isoflurane/blood , Pulmonary Ventilation/physiology , Ventilation-Perfusion Ratio/physiology , Anesthetics, Inhalation/administration & dosage , Animals , Animals, Newborn , Desflurane , Isoflurane/administration & dosage , Pulmonary Ventilation/drug effects , Respiration, Artificial/methods , Swine , Ventilation-Perfusion Ratio/drug effects
8.
Respir Physiol Neurobiol ; 220: 88-94, 2016 Jan.
Article En | MEDLINE | ID: mdl-26440992

Bronchoconstriction is a hallmark of asthma and impairs gas exchange. We hypothesized that pharmacokinetics of volatile anesthetics would be affected by bronchoconstriction. Ventilation/perfusion (VA/Q) ratios and pharmacokinetics of desflurane in both healthy state and during inhalational administration of methacholine (MCh) to double peak airway pressure were studied in a piglet model. In piglets, MCh administration by inhalation (100 µg/ml, n=6) increased respiratory resistance, impaired VA/Q distribution, increased shunt, and decreased paO2 in all animals. The uptake and elimination of desflurane in arterial blood was delayed by nebulization of MCh, as determined by Micropore Membrane Inlet Mass Spectrometry (wash-in time to P50, healthy vs. inhalation: 0.5 min vs. 1.1 min, to P90: 4.0 min vs. 14.8 min). Volatile elimination was accordingly delayed. Inhaled methacholine induced severe bronchoconstriction and marked inhomogeneous VA/Q distribution in pigs, which is similar to findings in human asthma exacerbation. Furthermore, MCh-induced bronchoconstriction delayed both uptake and elimination of desflurane. These findings might be considered when administering inhalational anesthesia to asthmatic patients.


Anesthetics, Inhalation/pharmacokinetics , Bronchoconstriction/drug effects , Bronchoconstrictor Agents/administration & dosage , Isoflurane/analogs & derivatives , Methacholine Chloride/administration & dosage , Administration, Inhalation , Animals , Asthma , Blood Chemical Analysis , Desflurane , Hemodynamics/drug effects , Isoflurane/pharmacokinetics , Mass Spectrometry , Prospective Studies , Respiration/drug effects , Sus scrofa
9.
Curr Opin Anaesthesiol ; 29(1): 2-7, 2016 Feb.
Article En | MEDLINE | ID: mdl-26545142

PURPOSE OF REVIEW: A major cause of hypoxemia in anesthesia is ventilation-perfusion (VA/Q) mismatch. With more advanced surgery and an aging population, monitoring of VA/Q is of increasing importance. RECENT FINDINGS: The classic multiple inert gas elimination technique has been simplified with a new approach based on mass spectrometry. VA/Q distributions can also be measured, at the bedside, by varying inspired oxygen concentration. MRI, 3-dimensional single photon emission computed tomography, positron emission tomography, and electrical impedance tomography enable imaging of perfusion and ventilation, and in some of the techniques also the distribution of inflammation. One-lung ventilation with thoracoscopy and capnothorax require careful monitoring of VA/Q, made possible bedside by electrical impedance tomography. Carbon dioxide, but not air, for pneumoperitoneum enhances shift of perfusion to ventilated regions. Ventilatory support during cardiopulmonary resuscitation causes less VA/Q mismatch when inspired oxygen concentrations are lower. Mechanisms of redistribution of lung blood flow by inhaled nitric oxide include endothelin-mediated vasoconstriction in collapsed lung regions. SUMMARY: Methods are continuously developing to simplify measurement of VA/Q and also to relate VA/Q to inflammation. The recording of VA/Q has helped to explain important aspects of gas exchange in thoracic anesthesiology and in intensive care medicine.


Anesthesia/methods , Hypoxia/prevention & control , Ventilation-Perfusion Ratio/physiology , Humans
10.
Data Brief ; 5: 939-47, 2015 Dec.
Article En | MEDLINE | ID: mdl-26702425

The data of a corresponding animal experiment demonstrates that nebulized methacholine (MCh) induced severe bronchoconstriction and significant inhomogeneous ventilation and pulmonary perfusion (V̇A/Q̇) distribution in pigs, which is similar to findings in human asthma. The inhalation of MCh induced bronchoconstriction and delayed both uptake and elimination of desflurane (Kretzschmar et al., 2015) [1]. The objective of the present data is to determine V̇A/Q̇ matching by Multiple Inert Gas Elimination Technique (MIGET) in piglets before and during methacholine- (MCh-) induced bronchoconstriction, induced by MCh infusion, and to assess the blood concentration profiles for desflurane (DES) by Micropore Membrane Inlet Mass Spectrometry (MMIMS). Healthy piglets (n=4) under general anesthesia were instrumented with arterial, central venous, and pulmonary artery lines. The airway was secured via median tracheostomy with an endotracheal tube, and animals were mechanically ventilated with intermittent positive pressure ventilation (IPPV) with a FiO2 of 0.4, tidal volume (V T)=10 ml/kg and PEEP of 5cmH2O using an open system. The determination of V.A/Q. was done by MIGET: before desflurane application and at plateau in both healthy state and during MCh infusion. Arterial blood was sampled at 0, 1, 2, 5, 10, 20, and 30 min during wash-in and washout, respectively. Bronchoconstriction was established by MCH infusion aiming at doubling the peak airway pressure, after which wash-in and washout of the anesthetic gas was repeated. Anesthesia gas concentrations were measured by MMIMS. Data were analyzed by ANOVA, paired t-test, and by nonparametric Friedman׳s test and Wilcoxon׳s matched pairs test. We measured airway pressures, pulmonary resistance, and mean paO2 as well as hemodynamic variables in all pigs before desflurane application and at plateau in both healthy state and during methacholine administration by infusion. By MIGET, fractional alveolar ventilation and pulmonary perfusion in relation to the V.A/Q. compartments, data of logSDQ̇ and logSDV̇ (the second moments describing global dispersion, i.e. heterogeneity of distribution) were estimated prior to and after MCh infusion. The uptake and elimination of desflurane was determined by MMIMS.

12.
Crit Care Med ; 43(3): e65-74, 2015 Mar.
Article En | MEDLINE | ID: mdl-25513783

OBJECTIVE: Cyclic recruitment and derecruitment of atelectasis can occur during mechanical ventilation, especially in injured lungs. Experimentally, cyclic recruitment and derecruitment can be quantified by respiration-dependent changes in PaO2 (ΔPaO2), reflecting the varying intrapulmonary shunt fraction within the respiratory cycle. This study investigated the effect of inspiration to expiration ratio upon ΔPaO2 and Horowitz index. DESIGN: Prospective randomized study. SETTING: Laboratory investigation. SUBJECTS: Piglets, average weight 30 ± 2 kg. INTERVENTIONS: At respiratory rate 6 breaths/min, end-inspiratory pressure (Pendinsp) 40 cm H2O, positive end-expiratory pressure 5 cm H2O, and FIO2 1.0, measurements were performed at randomly set inspiration to expiration ratios during baseline healthy and mild surfactant depletion injury. Lung damage was titrated by repetitive surfactant washout to induce maximal cyclic recruitment and derecruitment as measured by multifrequency phase fluorimetry. Regional ventilation distribution was evaluated by electrical impedance tomography. Step changes in airway pressure from 5 to 40 cm H2O and vice versa were performed after lavage to calculate PO2-based recruitment and derecruitment time constants (TAU). MEASUREMENTS AND MAIN RESULTS: In baseline healthy, cyclic recruitment and derecruitment could not be provoked, whereas in model acute respiratory distress syndrome, the highest ΔPaO2 were routinely detected at an inspiration to expiration ratio of 1:4 (range, 52-277 torr [6.9-36.9 kPa]). Shorter expiration time reduced cyclic recruitment and derecruitment significantly (158 ± 85 torr [21.1 ± 11.3 kPa] [inspiration to expiration ratio, 1:4]; 25 ± 12 torr [3.3 ± 1.6 kPa] [inspiration to expiration ratio, 4:1]; p < 0.0001), whereas the PaO2/FIO2 ratio increased (267 ± 50 [inspiration to expiration ratio, 1:4]; 424 ± 53 [inspiration to expiration ratio, 4:1]; p < 0.0001). Correspondingly, regional ventilation redistributed toward dependent lung regions (p < 0.0001). Recruitment was much faster (TAU: fast 1.6 s [78%]; slow 9.2 s) than derecruitment (TAU: fast 3.1 s [87%]; slow 17.7 s) (p = 0.0078). CONCLUSIONS: Inverse ratio ventilation minimizes cyclic recruitment and derecruitment of atelectasis in an experimental model of surfactant-depleted pigs. Time constants for recruitment and derecruitment, and regional ventilation distribution, reflect these findings and highlight the time dependency of cyclic recruitment and derecruitment.


Pulmonary Atelectasis/physiopathology , Respiration, Artificial/methods , Respiratory Distress Syndrome/physiopathology , Acute Lung Injury/physiopathology , Animals , Blood Gas Analysis , Exhalation/physiology , Inhalation/physiology , Positive-Pressure Respiration , Prospective Studies , Random Allocation , Swine , Therapeutic Irrigation
14.
PLoS One ; 9(1): e86638, 2014.
Article En | MEDLINE | ID: mdl-24475160

BACKGROUND: Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. METHODOLOGY/PRINCIPAL FINDINGS: Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R(2) = 0.96. Bland-Altman analysis showed a bias of -1.07±24.71 ml and limits of agreement of -49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R(2) values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. CONCLUSIONS/SIGNIFICANCE: Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT.


Diagnostic Imaging/methods , Pulmonary Ventilation/physiology , Tomography/methods , Vibration , Analysis of Variance , Animals , Electric Impedance , Models, Statistical , Spirometry , Swine
15.
J Appl Physiol (1985) ; 115(8): 1107-18, 2013 Oct 15.
Article En | MEDLINE | ID: mdl-23869066

The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.


Chromatography, Gas , Gas Chromatography-Mass Spectrometry , Membranes, Artificial , Micropore Filters , Noble Gases/blood , Pulmonary Ventilation , Ventilation-Perfusion Ratio , Animals , Animals, Newborn , Calibration , Chromatography, Gas/standards , Disease Models, Animal , Equipment Design , Gas Chromatography-Mass Spectrometry/instrumentation , Gas Chromatography-Mass Spectrometry/methods , Gas Chromatography-Mass Spectrometry/standards , Hyperventilation/blood , Hyperventilation/etiology , Hyperventilation/physiopathology , Lung Injury/blood , Lung Injury/chemically induced , Lung Injury/physiopathology , Manometry , Oleic Acid , Partial Pressure , Porosity , Pulmonary Circulation , Pulmonary Gas Exchange , Reference Standards , Respiration, Artificial , Swine , Time Factors
16.
Intensive Care Med ; 39(7): 1313-7, 2013 Jul.
Article En | MEDLINE | ID: mdl-23595498

PURPOSE: This study examines the correlation between the transpulmonary thermodilution derived extravascular lung water content (EVLW) and the ventilation/perfusion-distribution ([Formula: see text]) measured by multiple inert gas elimination (MIGET) in a porcine model. METHODS: [Formula: see text] measured by micropore membrane inlet mass spectrometry-MIGET (MMIMS-MIGET) and EVLW were simultaneously measured in twelve pigs in the heathy state, with impaired gas exchange from repetitive lung lavage and after 3 h of ventilation. The relationship between [Formula: see text] compartments and EVLW was analysed by linear correlation and regression. RESULTS: Considerable increases in EVLW and [Formula: see text] mismatching were induced through the lavage procedure. Significant correlations between the EVLW and the [Formula: see text] fractions representing pulmonary shunt and low [Formula: see text] were found. Perfusion to the normal [Formula: see text] regions was inversely correlated to the EVLW. CONCLUSIONS: Increased EVLW is associated with increased low [Formula: see text] and shunt, but not equal to pulmonary shunt alone. Beneath true shunt EVLW can also be associated with low [Formula: see text] regions.


Blood Gas Analysis/instrumentation , Extravascular Lung Water , Respiratory Distress Syndrome/physiopathology , Ventilation-Perfusion Ratio , Animals , Disease Models, Animal , Linear Models , Mass Spectrometry/instrumentation , Membranes, Artificial , Micropore Filters , Pulmonary Circulation , Swine , Thermodilution
17.
PLoS One ; 8(4): e60591, 2013.
Article En | MEDLINE | ID: mdl-23565259

BACKGROUND: Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. METHODOLOGY/PRINCIPAL FINDINGS: MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory setup (human packed red blood cells, haematocrit of 30%). The impacts of temperature (20, 30, 40°C) and blood flow (0.8, 1.6, 2.4, 3.2, 4.0 L min(-1)) on MFPF-PO2 measurements were assessed. MFPF response time in the gas- and blood-phase was determined. Porcine MFPF-PO2 ranged from 63 to 749 mmHg; the corresponding CTE samples from 43 to 712 mmHg. Linear regression: CTE = 15.59+1.18*MFPF (R(2) = 0.93; P<0.0001). Bland Altman analysis: meandiff 69.2 mmHg, rangediff -50.1/215.6 mmHg, 1.96-SD limits -56.3/194.8 mmHg. In artificial circulatory setup, MFPF-PO2 ranged from 20 to 567 mmHg and CTE samples from 11 to 575 mmHg. Linear regression: CTE = -8.73+1.05*MFPF (R(2) = 0.99; P<0.0001). Bland-Altman analysis: meandiff 6.6 mmHg, rangediff -9.7/20.5 mmHg, 1.96-SD limits -12.7/25.8 mmHg. Differences between MFPF and CTE-PO2 due to variations of temperature were less than 6 mmHg (range 0-140 mmHg) and less than 35 mmHg (range 140-750 mmHg); differences due to variations in blood flow were less than 15 mmHg (all P-values>0.05). MFPF response-time (monoexponential) was 1.48±0.26 s for the gas-phase and 1.51±0.20 s for the blood-phase. CONCLUSIONS/SIGNIFICANCE: MFPF-derived PO2 readings were reproducible and showed excellent correlation and good agreement with Clark-type electrode-based PO2 measurements. There was no relevant impact of temperature and blood flow upon MFPF-PO2 measurements. The response time of the MFPF FOXY-AL300 probe was adequate for real-time sensing in the blood phase.


Fluorometry/methods , Oxygen/physiology , Partial Pressure , Animals , Blood Gas Analysis , Models, Theoretical , Swine
18.
Crit Care ; 16(1): R8, 2012 Jan 16.
Article En | MEDLINE | ID: mdl-22248044

INTRODUCTION: Cyclic alveolar recruitment/derecruitment (R/D) is an important mechanism of ventilator-associated lung injury. In experimental models this process can be measured with high temporal resolution by detection of respiratory-dependent oscillations of the paO2 (ΔpaO2). A previous study showed that end-expiratory collapse can be prevented by an increased respiratory rate in saline-lavaged rabbits. The current study compares the effects of increased positive end-expiratory pressure (PEEP) versus an individually titrated respiratory rate (RRind) on intra-tidal amplitude of Δ paO2 and on average paO2 in saline-lavaged pigs. METHODS: Acute lung injury was induced by bronchoalveolar lavage in 16 anaesthetized pigs. R/D was induced and measured by a fast-responding intra-aortic probe measuring paO2. Ventilatory interventions (RRind (n=8) versus extrinsic PEEP (n=8)) were applied for 30 minutes to reduce Δ paO2. Haemodynamics, spirometry and Δ paO2 were monitored and the Ventilation/Perfusion distributions were assessed by multiple inert gas elimination. The main endpoints average and Δ paO2 following the interventions were analysed by Mann-Whitney-U-Test and Bonferroni's correction. The secondary parameters were tested in an explorative manner. RESULTS: Both interventions reduced Δ paO2. In the RRind group, ΔpaO2 was significantly smaller (P<0.001). The average paO2 continuously decreased following RRind and was significantly higher in the PEEP group (P<0.001). A sustained difference of the ventilation/perfusion distribution and shunt fractions confirms these findings. The RRind application required less vasopressor administration. CONCLUSIONS: Different recruitment kinetics were found compared to previous small animal models and these differences were primarily determined by kinetics of end-expiratory collapse. In this porcine model, respiratory rate and increased PEEP were both effective in reducing the amplitude of paO2 oscillations. In contrast to a recent study in a small animal model, however, increased respiratory rate did not maintain end-expiratory recruitment and ultimately resulted in reduced average paO2 and increased shunt fraction.


Disease Models, Animal , Lung Injury/physiopathology , Positive-Pressure Respiration , Pulmonary Alveoli/physiology , Respiratory Rate/physiology , Animals , Lung Injury/therapy , Pilot Projects , Positive-Pressure Respiration/methods , Random Allocation , Swine , Time Factors
19.
Free Radic Biol Med ; 51(11): 1952-65, 2011 Dec 01.
Article En | MEDLINE | ID: mdl-21958548

Inducible nitric oxide synthase (iNOS) catalyzes the reaction that converts the substrates O(2) and l-arginine to the products nitric oxide (NO) and l-citrulline. Macrophages, and many other cell types, upregulate and express iNOS primarily in response to inflammatory stimuli. Physiological and pathophysiological oxygen tension can regulate NO production by iNOS at multiple levels, including transcriptional, translational, posttranslational, enzyme dimerization, cofactor availability, and substrate dependence. Cell culture techniques that emphasize control of cellular PO(2), and measurement of NO or its stable products, have been used by several investigators for in vitro study of the O(2) dependence of NO production at one or more of these levels. In most cell types, prior or concurrent exposure to cytokines or other inflammatory stimuli is required for the upregulation of iNOS mRNA and protein by hypoxia. Important transcription factors that target the iNOS promoter in hypoxia include hypoxia-inducible factor 1 and/or nuclear factor κB. In contrast to the upregulation of iNOS by hypoxia, in most cell types NO production is reduced by hypoxia. Recent work suggests a prominent role for O(2) substrate dependence in the short-term regulation of iNOS-mediated NO production.