Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 88
2.
Circ Arrhythm Electrophysiol ; : e012517, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38666379

BACKGROUND: Sacubitril/valsartan (Sac/Val) is superior to angiotensin-converting enzyme inhibitors in reducing the risk of heart failure hospitalization and cardiovascular death, but its mechanistic data on myocardial scar after myocardial infarction (MI) are lacking. The objective of this work was to assess the effects of Sac/Val on inflammation, fibrosis, electrophysiological properties, and ventricular tachycardia inducibility in post-MI scar remodeling in swine. METHODS: After MI, 22 pigs were randomized to receive ß-blocker (BB; control, n=8) or BB+Sac/Val (Sac/Val, n=9). The systemic immune response was monitored. Cardiac magnetic resonance data were acquired at 2-day and 29-day post MI to assess ventricular remodeling. Programmed electrical stimulation and high-density mapping were performed at 30-day post MI to assess ventricular tachycardia inducibility. Myocardial samples were collected for histological analysis. RESULTS: Compared with BB, BB+Sac/Val reduced acute circulating leukocytes (P=0.009) and interleukin-12 levels (P=0.024) at 2-day post MI, decreased C-C chemokine receptor type 2 expression in monocytes (P=0.047) at 15-day post MI, and reduced scar mass (P=0.046) and border zone mass (P=0.043). It also lowered the number and mass of border zone corridors (P=0.020 and P=0.05, respectively), scar collagen I content (P=0.049), and collagen I/III ratio (P=0.040). Sac/Val reduced ventricular tachycardia inducibility (P=0.026) and the number of deceleration zones (P=0.016). CONCLUSIONS: After MI, compared with BB, BB+Sac/Val was associated with reduced acute systemic inflammatory markers, reduced total scar and border zone mass on late gadolinium-enhanced magnetic resonance imaging, and lower ventricular tachycardia inducibility.

3.
Rev. esp. cardiol. (Ed. impr.) ; 76(11): 910-921, Nov. 2023. tab, graf
Article Es | IBECS | ID: ibc-226975

Introducción y objetivos: Se presentan los resultados del Registro español de ablación con catéter correspondientes a 2022. Métodos: Registro de actividad restrospectivo de los datos introducidos en la plataforma REDCap utilizando un formulario específico. Resultados: Participaron 103 centros (75 públicos, 28 privados) que comunicaron 23.360 procedimientos de ablación, con una media de 227±173 y una mediana de 202 [intervalo intercuartílico, 77-312] procedimientos por centro. Se ha producido un incremento muy significativo de la actividad (+5.419 casos,+30,2%) y de los centros participantes (10 centros más que en 2021). El procedimiento más frecuente sigue siendo la ablación de fibrilación auricular (FA) (el 35%, 8.185 casos) seguido de la ablación del istmo cavotricuspídeo (el 20%, 4.640 casos) y la taquicardia por reentrada intranodular (el 17%, 3.898 casos). Crecen todos los sustratos, especialmente la ablación de FA (+40%), y aumenta ligeramente el éxito agudo global, que alcanza el 96%, y disminuyen las tasas de complicaciones hasta el 1,8% (n=422) y de mortalidad (0,04%; n=10). Se realizaron 525 ablaciones en pacientes pediátricos (2,2%). Conclusiones: El Registro español de ablación con catéter recoge de manera sistemática e ininterrumpida la trayectoria nacional, que este año muestra un incremento muy significativo de la actividad en todos los sustratos, pero especialmente la referente a ablación de FA. Aumenta ligeramente la tasa de éxito y se reducen tanto la tasa de complicaciones como la mortalidad.(AU)


Introduction and objectives: This article presents results of the Spanish catheter ablation registry for the year 2022. MethodsData were retrospectively entered into a REDCap platform using a specific form. Results: A total of 103 centers participated (75 public, 28 private), which reported 23 360 ablation procedures, with a mean of 227±173 and a median of 202 [interquartile range, 77-312] procedures per center. Activity significantly increased (+5419 procedures,+30.2%) with more centers participating in the registry (10 more than in 2021). The most common procedure continued to be atrial fibrillation ablation (35%, 8185 procedures) followed by cavotricuspid isthmus ablation (20%, 4640 procedures), and intranodal re-entrant tachycardia (17%, 3898 procedures). There was an increase in all reported substrates, especially atrial fibrillation ablation (+40%), with slightly higher global acute success (96%) and lower complication rates (1.8%) and mortality (0.04%, n=10). In total, 525 procedures were performed in pediatric patients (2.2%). Conclusions: The Spanish catheter ablation registry systematically and continuously collects the national trajectory, which experienced a significant activity increase in 2022 in all of the reported substrates but especially in atrial fibrillation ablation. Acute success increased, while both complications and mortality decreased.(AU)


Humans , Male , Female , Cardiology/statistics & numerical data , Electrophysiology , Arrhythmias, Cardiac , Catheter Ablation/statistics & numerical data , Records
4.
Gastroenterol. hepatol. (Ed. impr.) ; 46(8): 621-627, oct. 2023. tab, ilus
Article En | IBECS | ID: ibc-225940

Background: Oral anticoagulation in non-valvular atrial fibrillation is associated with an increased risk of bleeding, particularly gastrointestinal bleeding, leading to treatment withdrawal in up to 50% of patients and putting them at risk of embolic events. Left atrial appendage closure (LAAC) can be an alternative to chronic anticoagulation. We aim to describe the impact of LAAC in patients with gastrointestinal bleeding (GIB) or chronic iron deficiency anaemia (CIDA) on healthcare resources consumption. Methods: Observational retrospective study of patients who underwent LAAC for GIB or CIDA at a single centre. Results: Nineteen patients with a median age of 74 years and a median Charlson score of six points were included in the study. Angiodysplasias were the most frequent cause of GIB or CIDA. The procedural success rate of LAAC was 100% with a median anticoagulant and antiplatelet treatment duration of 92 days. One year after the LAAC, we found a significant improvement in the lowest haemoglobin concentration and a reduction in the number of red blood cells transfusion, hospital admissions due to GIB and CIDA and the number of endoscopic examinations. One patient died due to a pulmonary thromboembolism. No deaths related to GIB were observed. Conclusions: LAAC seems to be a safe and effective alternative to anticoagulation in patients with GIB or CIDA. (AU)


Introducción: La anticoagulación oral en la fibrilación auricular no valvular se asocia a un incremento del riesgo de sangrado, especialmente gastrointestinal, lo que conlleva la retirada del tratamiento hasta en el 50% de los pacientes e implica un mayor riesgo de padecer un evento embólico. El cierre de la orejuela izquierda (COI) puede ser una alternativa a la anticoagulación crónica. Nuestro objetivo es describir el impacto del COI en pacientes con sangrado gastrointestinal (SGI) o anemia crónica ferropénica (ACF) en el consumo de recursos sanitarios. Métodos: Estudio observacional retrospectivo de pacientes sometidos a COI por SGI o ACF. Resultados: Diecinueve pacientes con una mediana de edad de 74años y una mediana del índice de Charlson de 6puntos fueron incluidos en el estudio. Las angiodisplasias fueron la causa más frecuente de SGI o ACF. La tasa de éxito técnico del COI fue del 100%, con una duración mediana del tratamiento anticoagulante y antiagregante de 92días. Tras un año del COI, se observó una mejoría significativa del valor mínimo de hemoglobina, así como una reducción en el número de transfusiones de concentrados de hematíes, en la necesidad de hospitalización por SGI o ACF y en el número de endoscopias. Un paciente falleció debido a un tromboembolismo pulmonar. Ningún paciente falleció por SGI. Conclusiones: El COI parece una alternativa segura y efectiva a la anticoagulación en pacientes con SGI o ACF. (AU)


Humans , Male , Female , Aged , Aged, 80 and over , Atrial Fibrillation , Gastrointestinal Hemorrhage , Anemia, Iron-Deficiency , Retrospective Studies , Epidemiology, Descriptive , Anticoagulants
5.
PLoS One ; 18(9): e0291938, 2023.
Article En | MEDLINE | ID: mdl-37738256

BACKGROUND: Several studies have shown an independent relationship between body mass index (BMI) and the incidence of atrial fibrillation (AF). However, little is known about the influence of BMI on AF recurrence after electrical cardioversion (ECV). METHODS: We selected 1121 patients who reverted to sinus rhythm after scheduled ECV and were included in three prospective Spanish registries of ECV in persistent AF. The patients were classified according to baseline BMI into three categories (normal weight, overweight, obesity). We assessed the influence of BMI on the rate of AF recurrence at 3 months. RESULTS: We identified 538 patients (48%) who had AF recurrence in the first 3 months after successful ECV. The patients who suffered AF recurrence had a higher BMI than those who remained in sinus rhythm (29.66±4.57 vs. 28.87±4.64 Kg/m2, respectively; p = 0.004). We observed a higher incidence of AF recurrence in the overweight and obese patients (BMI ≥25 kg/m2) than in those classified as normal weight (50.5% vs. 35.6%, respectively; p<0,001). BMI≥25 Kg/m2 was shown to be independently related to of AF recurrence in the multivariate analysis (OR = 1.75, 95% confidence interval = 1.20-2.58; p = 0.004). CONCLUSIONS: Increased BMI is independently related to AF recurrence after ECV. BMI should also be taken into account when making decisions about the indication for ECV in persistent AF.


Atrial Fibrillation , Humans , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Electric Countershock , Body Mass Index , Overweight/complications , Overweight/therapy , Prospective Studies , Obesity/complications , Obesity/therapy
6.
Rev Esp Cardiol (Engl Ed) ; 76(11): 910-921, 2023 Nov.
Article En, Es | MEDLINE | ID: mdl-37730116

INTRODUCTION AND OBJECTIVES: This article presents results of the Spanish catheter ablation registry for the year 2022. METHODS: Data were retrospectively entered into a REDCap platform using a specific form. RESULTS: A total of 103 centers participated (75 public, 28 private), which reported 23 360 ablation procedures, with a mean of 227±173 and a median of 202 [interquartile range, 77-312] procedures per center. Activity significantly increased (+5419 procedures,+30.2%) with more centers participating in the registry (10 more than in 2021). The most common procedure continued to be atrial fibrillation ablation (35%, 8185 procedures) followed by cavotricuspid isthmus ablation (20%, 4640 procedures), and intranodal re-entrant tachycardia (17%, 3898 procedures). There was an increase in all reported substrates, especially atrial fibrillation ablation (+40%), with slightly higher global acute success (96%) and lower complication rates (1.8%) and mortality (0.04%, n=10). In total, 525 procedures were performed in pediatric patients (2.2%) CONCLUSIONS: The Spanish catheter ablation registry systematically and continuously collects the national trajectory, which experienced a significant activity increase in 2022 in all of the reported substrates but especially in atrial fibrillation ablation. Acute success increased, while both complications and mortality decreased.


Atrial Fibrillation , Cardiology , Catheter Ablation , Humans , Child , Atrial Fibrillation/surgery , Retrospective Studies , Registries
7.
Pacing Clin Electrophysiol ; 46(8): 939-941, 2023 08.
Article En | MEDLINE | ID: mdl-37461381

Over the last decades, cardiac electronic implantable devices (CEID) have incorporated a myriad of technological capabilities that are not conveniently inferred by using the conventional ICHD and NBG coding systems. We propose a new coding system (i.e., the C-ARL-A coding system) aimed at overcoming this important limitation.


Defibrillators, Implantable , Pacemaker, Artificial , Humans
8.
JACC Clin Electrophysiol ; 9(6): 765-775, 2023 06.
Article En | MEDLINE | ID: mdl-36752472

BACKGROUND: New tools are needed to improve ventricular tachycardia (VT) substrate characterization and optimize outcomes. LI provides biophysical tissue characterization. OBJECTIVES: The purpose of this study was to test local impedance (LI)-based mapping to predict critical ventricular tachycardia components after myocardial infarction (MI). METHODS: One month after a nonreperfused anterior MI, endo-epicardial high-density electroanatomic mapping and endocardial LI mapping were performed in 23 Landrace Large X White pigs. LI thresholds were set using the blood pool value to define a 10 Ω range: low (blood pool +9Ω). RESULTS: Low LI was detected in low-voltage areas in 100% of cases, but intermediate LI was found in both core (87%) and border zone (12.5%) voltage areas. A total of 17 VTs were induced (VT isthmus identified in 9 animals). VT inducibility was associated with the size of intermediate LI area (OR: 1.19 [95% CI: 1.0-1.4]; P = 0.039) and the presence of specific LI patterns: LI corridor (OR: 15.0 [95% CI: 1.3-169.9]; P = 0.029); LI gradient (OR: 30.0 [95% CI: 2.1-421.1]; P = 0.012), high LI heterogeneity (OR: 21.7 [95% CI: 1.8-260.6]; P = 0.015), and presence of ≥2 low LI regions (OR: 11.3 [95% CI: 1.0-130.2]; P = 0.053). Potential VT isthmuses were in areas of intermediate LI and colocalized to LI patterns associated with VT inducibility in all cases (LI corridors or LI gradient). Low LI regions did not actively participate in the VT circuit (0%). CONCLUSIONS: LI mapping is feasible and may add useful characterization of the VT substrate. Specific LI patterns (ie, corridors, gradients) were associated with VT inducibility and colocalized with the VT isthmus, thus representing a potential new target for ablation in substrate-based procedures.


Myocardial Infarction , Tachycardia, Ventricular , Animals , Swine , Electric Impedance , Myocardial Infarction/complications , Epicardial Mapping , Endocardium
9.
Gastroenterol Hepatol ; 46(8): 621-627, 2023 Oct.
Article En, Es | MEDLINE | ID: mdl-36828118

BACKGROUND: Oral anticoagulation in non-valvular atrial fibrillation is associated with an increased risk of bleeding, particularly gastrointestinal bleeding, leading to treatment withdrawal in up to 50% of patients and putting them at risk of embolic events. Left atrial appendage closure (LAAC) can be an alternative to chronic anticoagulation. We aim to describe the impact of LAAC in patients with gastrointestinal bleeding (GIB) or chronic iron deficiency anaemia (CIDA) on healthcare resources consumption. METHODS: Observational retrospective study of patients who underwent LAAC for GIB or CIDA at a single centre. RESULTS: Nineteen patients with a median age of 74 years and a median Charlson score of six points were included in the study. Angiodysplasias were the most frequent cause of GIB or CIDA. The procedural success rate of LAAC was 100% with a median anticoagulant and antiplatelet treatment duration of 92 days. One year after the LAAC, we found a significant improvement in the lowest haemoglobin concentration and a reduction in the number of red blood cells transfusion, hospital admissions due to GIB and CIDA and the number of endoscopic examinations. One patient died due to a pulmonary thromboembolism. No deaths related to GIB were observed. CONCLUSIONS: LAAC seems to be a safe and effective alternative to anticoagulation in patients with GIB or CIDA.


Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Aged , Atrial Fibrillation/complications , Stroke/complications , Atrial Appendage/surgery , Retrospective Studies , Treatment Outcome , Anticoagulants/adverse effects , Gastrointestinal Hemorrhage/complications
10.
J Interv Card Electrophysiol ; 66(3): 683-691, 2023 Apr.
Article En | MEDLINE | ID: mdl-36207558

BACKGROUND: Adequate synchronization between the passive ("E") and active ("a") left ventricular (LV) diastolic filling contributes to the efficiency of the heartbeat. E/a superposition in dual-chamber pacemaker (PM) recipients is an under-recognized phenomenon that may be corrected by shortening the atrio-ventricular interval (AVI). We aimed at establishing the prevalence of E/a superposition in PM patients and to analyze the clinical, echocardiographic, and biological impact of AVI shortening. METHODS: Seventy patients with dual-chamber PMs (74 ± 8 years old, 12 women) were consecutively enrolled in this study. Patients with baseline E/a superposition were crossed over from default to manually shortened AVI or vice versa in a case-control fashion (intervention group). Patients without baseline E/a superposition (controls) served as a reference for a descriptive comparison with the intervention group. RESULTS: Thirty-three patients had E/a superposition after PM implantation (47%). Controls (n = 37) had higher LV ejection fraction (59 ± 8% vs. 53 ± 10%, p = 0.048) and lower levels of high sensitive troponin T and ST2 (p < 0.05) than intervention group patients. The AVI was shortened at 48 ± 9 ms in order to ensure adequate E/a separation. The walked distance increased from 75 ± 17 to 78 ± 10% (p = 0.049) and the Euro-QoL score from 0.50 ± 0.27 to 0.63 ± 0.19 (p = 0.011) with short AVI. CONCLUSIONS: E/a superposition occurs in approximately half of dual-chamber PM recipients and is associated with reduced LV function and increased myocardial injury biomarkers. AVI shortening produces a modest but significant effect in functional capacity and quality of life.


Pacemaker, Artificial , Quality of Life , Humans , Female , Aged , Aged, 80 and over , Cardiac Pacing, Artificial , Diastole , Ventricular Function, Left
11.
Rev. esp. cardiol. (Ed. impr.) ; 75(12): 1029-1039, dic. 2022. tab, graf
Article Es | IBECS | ID: ibc-212936

Introducción y objetivos: Se describen los resultados del Registro español de ablación con catéter correspondientes al año 2021, marcado por la recuperación de la actividad tras la pandemia de SARS-CoV-2. Métodos: La recogida de datos fue restrospectiva mediante la cumplimentación y el envío de un formulario específico por los centros participantes. Resultados: Se analizaron los datos de 93 centros (65 públicos, 28 privados). Se comunicaron 17.941 procedimientos de ablación con una media de 193±133 y mediana de 171. La recuperación de la actividad tras el cierre por la pandemia de SARS-CoV-2ha supuesto un marcado aumento de procedimientos (+2.772 casos, +18%) a pesar de un ligero descenso en el número de centros participantes (4 menos que en 2020). La ablación de la fibrilación auricular sigue siendo el procedimiento más frecuente, a distancia del resto de sustratos (5.848; 32,6%). Junto con la ablación del istmo cavotricuspídeo (3.766; 21%) y la taquicardia por reentrada intranodular (3.132; 17,5%), constituye los 3 sustratos abordados con más frecuencia. Las tasas comunicadas de éxito (94%), complicaciones (2%) y mortalidad (0,07%) son similares a las de años previos. Se realizaron 401 procedimientos en pacientes pediátricos (el 3,8% del total). Conclusiones: El Registro español de ablación con catéter recoge de manera sistemática e ininterrumpida la actividad nacional, y este año se ha observado una marcada recuperación de la actividad a pesar del persistente efecto de la pandemia de SARS-CoV-2. La tasa de éxito sigue manteniéndose elevada, con una baja tasa de complicaciones.(AU)


Introduction and objectives: The results of the 2021 Spanish catheter ablation registry are presented. Methods: Data collection was carried out retrospectively by filling in and sending a specific form by the participating centers. Results: Data from 93 centers (65 public, 28 private) were analyzed. A total of 17941 ablation procedures were reported with a mean of 193±133 clases per centre. Recovery of activity from SARS-CoV-2 pandemic lockdown has led to a notable increase in the number of procedures (+2772 procedures, +18%) despite a small decrease in participating centers (4 centers less than in 2020). Atrial fibrillation ablation continues to be the leading procedure, with 5848 procedures (32,6%). Together with ablation of the cavotricuspid isthmus (3766; 21%) and atrioventricular nodal reentrant tachycardia (3132; 17,5%) they constitute the 3 most frequently approached substrates. The total success rate reported (94%) is similar to previous years with a similar rate of complications (2%) and mortality (0.07). A total of 401 procedures were performed in pediatric patients (3,8%). Conclusions: The Spanish catheter ablation registry systematically and continuously collects the national activity, which has recovered significantly from the SARS-CoV-2 pandemic impact in 2020. Success rate for 2021 remains high, with a low complication rate.(AU)


Humans , Catheter Ablation , Electrophysiology , Arrhythmias, Cardiac , Severe acute respiratory syndrome-related coronavirus , Coronavirus Infections , Pandemics , Cardiology , Heart Diseases , Retrospective Studies , Surveys and Questionnaires
12.
Front Cardiovasc Med ; 9: 983001, 2022.
Article En | MEDLINE | ID: mdl-36204562

Objective: To assess the arrhythmic safety profile of the adipose graft transposition procedure (AGTP) and its electrophysiological effects on post-myocardial infarction (MI) scar. Background: Myocardial repair is a promising treatment for patients with MI. The AGTP is a cardiac reparative therapy that reduces infarct size and improves cardiac function. The impact of AGTP on arrhythmogenesis has not been addressed. Methods: MI was induced in 20 swine. Contrast-enhanced magnetic resonance (ce-MRI), electrophysiological study (EPS), and left-ventricular endocardial high-density mapping were performed 15 days post-MI. Animals were randomized 1:1 to AGTP or sham-surgery group and monitored with ECG-Holter. Repeat EPS, endocardial mapping, and ce-MRI were performed 30 days post-intervention. Myocardial SERCA2, Connexin-43 (Cx43), Ryanodine receptor-2 (RyR2), and cardiac troponin-I (cTnI) gene and protein expression were evaluated. Results: The AGTP group showed a significant reduction of the total infarct scar, border zone and dense scar mass by ce-MRI (p = 0.04), and a decreased total scar and border zone area in bipolar voltage mapping (p < 0.001). AGTP treatment significantly reduced the area of very-slow conduction velocity (<0.2 m/s) (p = 0.002), the number of deceleration zones (p = 0.029), and the area of fractionated electrograms (p = 0.005). No differences were detected in number of induced or spontaneous ventricular arrhythmias at EPS and Holter-monitoring. SERCA2, Cx43, and RyR2 gene expression were decreased in the infarct core of AGTP-treated animals (p = 0.021, p = 0.018, p = 0.051, respectively). Conclusion: AGTP is a safe reparative therapy in terms of arrhythmic risk and provides additional protective effect against adverse electrophysiological remodeling in ischemic heart disease.

13.
Rev Esp Cardiol (Engl Ed) ; 75(12): 1029-1039, 2022 Dec.
Article En, Es | MEDLINE | ID: mdl-36244656

INTRODUCTION AND OBJECTIVES: The results of the 2021 Spanish catheter ablation registry are presented. METHODS: Data collection was carried out retrospectively by filling in and sending a specific form by the participating centers. RESULTS: Data from 93 centers (65 public, 28 private) were analyzed. A total of 17941 ablation procedures were reported with a mean of 193 ± 133 cases per centre. Recovery of activity from SARS-CoV-2 pandemic lockdown has led to a notable increase in the number of procedures (+2772 procedures, +18%) despite a small decrease in participating centers (4 centers less than in 2020). Atrial fibrillation ablation continues to be the leading procedure, with 5848 procedures (32,6%). Together with ablation of the cavotricuspid isthmus (3766; 21%) and atrioventricular nodal reentrant tachycardia (3132; 17,5%) they constitute the 3 most frequently approached substrates. The total success rate reported (94%) is similar to previous years with a similar rate of complications (2%) and mortality (0.07). A total of 401 procedures were performed in pediatric patients (3,8%). CONCLUSIONS: The Spanish catheter ablation registry systematically and continuously collects the national activity, which has recovered significantly from the SARS-CoV-2 pandemic impact in 2020. Success rate for 2021 remains high, with a low complication rate.


Atrial Fibrillation , COVID-19 , Cardiology , Catheter Ablation , Humans , Child , Retrospective Studies , SARS-CoV-2 , COVID-19/epidemiology , Communicable Disease Control , Registries , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery
14.
Rev Esp Cardiol ; 75(12): 1029-1039, 2022 Dec.
Article Es | MEDLINE | ID: mdl-36164639

Introduction and objectives: The results of the 2021 Spanish catheter ablation registry are presented. Methods: Data collection was carried out retrospectively by filling in and sending a specific form by the participating centers. Results: Data from 93 centers (65 public, 28 private) were analyzed. A total of 17941 ablation procedures were reported with a mean of 193 ± 133 clases per centre. Recovery of activity from SARS-CoV-2 pandemic lockdown has led to a notable increase in the number of procedures (+2772 procedures, +18%) despite a small decrease in participating centers (4 centers less than in 2020). Atrial fibrillation ablation continues to be the leading procedure, with 5848 procedures (32,6%). Together with ablation of the cavotricuspid isthmus (3766; 21%) and atrioventricular nodal reentrant tachycardia (3132; 17,5%) they constitute the 3 most frequently approached substrates. The total success rate reported (94%) is similar to previous years with a similar rate of complications (2%) and mortality (0.07). A total of 401 procedures were performed in pediatric patients (3,8%). Conclusions: The Spanish catheter ablation registry systematically and continuously collects the national activity, which has recovered significantly from the SARS-CoV-2 pandemic impact in 2020. Success rate for 2021 remains high, with a low complication rate.

15.
Sci Rep ; 12(1): 298, 2022 01 07.
Article En | MEDLINE | ID: mdl-34996973

Inappropriate sinus tachycardia (IST) is a common observation in patients with post-COVID-19 syndrome (PCS) but has not yet been fully described to date. To investigate the prevalence and the mechanisms underlying IST in a prospective population of PCS patients. Consecutive patients admitted to the PCS Unit between June and December 2020 with a resting sinus rhythm rate ≥ 100 bpm were prospectively enrolled in this study and further examined by an orthostatic test, 2D echocardiography, 24-h ECG monitoring (heart rate variability was a surrogate for cardiac autonomic activity), quality-of-life and exercise capacity testing, and blood sampling. To assess cardiac autonomic function, a 2:1:1 comparative sub-analysis was conducted against both fully recovered patients with previous SARS-CoV-2 infection and individuals without prior SARS-CoV-2 infection. Among 200 PCS patients, 40 (20%) fulfilled the diagnostic criteria for IST (average age of 40.1 ± 10 years, 85% women, 83% mild COVID-19). No underlying structural heart disease, pro-inflammatory state, myocyte injury, or hypoxia were identified. IST was accompanied by a decrease in most heart rate variability parameters, especially those related to cardiovagal tone: pNN50 (cases 3.2 ± 3 vs. recovered 10.5 ± 8 vs. non-infected 17.3 ± 10; p < 0.001) and HF band (246 ± 179 vs. 463 ± 295 vs. 1048 ± 570, respectively; p < 0.001). IST is prevalent condition among PCS patients. Cardiac autonomic nervous system imbalance with decreased parasympathetic activity may explain this phenomenon.


COVID-19/complications , Tachycardia, Sinus/etiology , Adult , COVID-19/diagnosis , COVID-19/pathology , COVID-19/physiopathology , Female , Heart Rate , Humans , Male , Middle Aged , Myocardium/pathology , Prevalence , Prospective Studies , SARS-CoV-2/isolation & purification , Tachycardia, Sinus/diagnosis , Tachycardia, Sinus/pathology , Tachycardia, Sinus/physiopathology , Post-Acute COVID-19 Syndrome
16.
J Interv Card Electrophysiol ; 63(3): 591-599, 2022 Apr.
Article En | MEDLINE | ID: mdl-34595692

BACKGROUND: Catheter ablation of accessory pathways (AP) with bidirectional conduction may be challenging due to issues related to anatomical course or location. OBJECTIVE: We describe an alternative electro-anatomical mapping technique which aims at depicting the entire anatomic course of the AP from the atrial toward the ventricular insertion in order to guide catheter ablation. METHODS: Twenty consecutive patients with confirmed bidirectional AP conduction and at least one previous ablation procedure or para-Hisian location were included. 3-D electro-anatomical mapping was used to depict the merged 10-ms isochrone area of maximum early activation of both the ventricular and atrial signals during sinus rhythm and ventricular pacing/orthodromic tachycardia, respectively. Catheter ablation was performed within the depicted earliest isochrone area. RESULTS: Acute bidirectional AP conduction block was achieved in all patients 4.2 ± 1.7 s after the first radiofrequency energy pulse was delivered, without reconnection during a 30 ± 10 min post-ablation observation time. No procedural complications were seen. After a mean follow-up period of 9 ± 7 months (range 3 to 16), no recurrences were documented. CONCLUSION: This merged two-way mapping technique is a safe, efficient, and effective technique for ablation of APs with bidirectional conduction.


Accessory Atrioventricular Bundle , Catheter Ablation , Accessory Atrioventricular Bundle/surgery , Catheter Ablation/methods , Electrocardiography , Heart Atria/diagnostic imaging , Heart Atria/surgery , Heart Rate , Humans
17.
Clin Res Cardiol ; 111(9): 1018-1027, 2022 Sep.
Article En | MEDLINE | ID: mdl-34854991

AIMS: Despite advances in interventional treatment strategies, atrial fibrillation (AF) remains associated with significant morbidity and mortality. Fibrotic atrial myopathy (FAM) is a main factor for adverse outcomes of AF-ablation, but complex to diagnose using current methods. We aimed to derive a scoring system based entirely on easily available clinical parameters to predict FAM and ablation-success in everyday care. METHODS: In this multicenter, prospective study, a new risk stratification model termed AF-SCORE was derived in 220 patients undergoing high-density left-atrial(LA) voltage-mapping to quantify FAM. AF-SCORE was validated for FAM in an external mapping-validation cohort (n = 220) and for success following pulmonary vein isolation (PVI)-only (without adjunctive left- or right atrial ablations) in an external outcome-validation cohort (n = 518). RESULTS: FAM was rare in patients < 60 years (5.4%), but increased with ageing and affected 40.4% (59/146) of patients ≥ 60 years. Sex and AF-phenotype had additional predictive value in older patients and remained associated with FAM in multivariate models (odds ratio [OR] 6.194, p < 0.0001 for ≥ 60 years; OR 2.863, p < 0.0001 for female sex; OR 41.309, p < 0.0001 for AF-persistency). Additional clinical or diagnostic variables did not improve the model. AF-SCORE (+ 1 point for age ≥ 60 years and additional points for female sex [+ 1] and AF-persistency [+ 2]) showed good discrimination to detect FAM (c-statistic 0.792) and predicted arrhythmia-freedom following PVI (74.3%, 54.7% and 45.5% for AF-SCORE ≤ 2, 3 and 4, respectively, and hazard ratio [HR] 1.994 for AF-SCORE = 3 and HR 2.866 for AF-SCORE = 4, p < 0.001). CONCLUSIONS: Age, sex and AF-phenotype are the main determinants for the development of FAM. A low AF-SCORE ≤ 2 is found in paroxysmal AF-patients of any age and younger patients with persistent AF irrespective of sex, and associated with favorable outcomes of PVI-only. Freedom from arrhythmia remains unsatisfactory with AF-SCORE ≥ 3 as found in older patients, particularly females, with persistent AF, and future studies investigating adjunctive atrial ablations to PVI-only should focus on these groups of patients.


Atrial Fibrillation , Cardiomyopathies , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cardiomyopathies/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Fibrosis , Humans , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
19.
JACC Case Rep ; 3(1): 150-155, 2021 Jan.
Article En | MEDLINE | ID: mdl-34317491

Up to one-third of patients who undergo cardiac resynchronization therapy do not obtain clinical benefit. A systematic approach can identify treatable causes in many nonresponding patients. We present a case of nonresponse to cardiac resynchronization therapy that resolved by ablation of the atrioventricular node in a patient with complete atrioventricular block. (Level of Difficulty: Advanced.).

20.
J Clin Med ; 10(5)2021 Mar 03.
Article En | MEDLINE | ID: mdl-33802253

BACKGROUND: Antiarrhythmic drugs (AADs) are frequently initiated in patients with persistent atrial fibrillation (AF) prior to electrical cardioversion (ECV), achieving pharmacological cardioversion (PCV) in some cases. Little is known about the mode of cardioversion and the effect of the type of AAD used in the maintenance of sinus rhythm (SR). METHODS: From three national surveys of patients with persistent AF referred for ECV, we selected those who were pre-treated with AADs (amiodarone or group Ic AADs). We analyzed the effect of the type of cardioversion (pharmacological vs. electrical) and the AAD used in the maintenance of SR at three months. RESULTS: Among the 665 patients selected, 151 had a successful PCV prior to the planned ECV. In the remaining 514 patients, 460 had a successful ECV. A successful PCV was related to a higher rate of SR maintenance than a successful ECV (77.9% vs. 57.5%; p < 0.0001). After a successful PCV, the maintenance of SR was identical in those patients treated with amiodarone and those treated with group Ic AADs (77.4% vs. 77.5%; p = 0.99), whereas after a successful ECV, amiodarone was clearly superior to group Ic AADs (61.3% vs. 43.0%; p = 0.001). Considering patients with successful PCV and ECV together, PCV was an independent factor related to the maintenance of SR. CONCLUSIONS: In patients with persistent AF, successful PCV selects a subgroup with a high probability of maintenance of SR. With regard to drugs, amiodarone was superior to group Ic AADs in patients with ECV, whereas in PCV, no differences were observed.

...