Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 245
Filtrar
1.
Res Sq ; 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38853854

RESUMEN

To understand how the health of older adults today compares to that of previous generations, we estimated intrinsic capacity and subdomains of cognitive, locomotor, sensory, psychological and vitality capacities in participants of the English Longitudinal Study on Ageing (ELSA) and the China Health and Retirement Longitudinal Study (CHARLS). We applied multilevel growth curve models to examine change over time and cohort trends. We found that more recent cohorts entered older ages with higher levels of capacity, and their subsequent age-related declines were somewhat compressed compared to earlier cohorts. These improvements in capacity were large, with the greatest gains being in the most recent cohorts. For example, a 68-year-old ELSA participant born in 1950 had higher capacity than a 62-year-old born just 10 years earlier. Trends were similar for men and women, and findings were generally consistent across English and Chinese cohorts.

2.
Diseases ; 12(6)2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38920561

RESUMEN

Previous studies involving workers at brick kilns in the Kathmandu Valley of Nepal have investigated chronic exposure to hazardous levels of fine particulate matter (PM2.5) common in ambient and occupational environments. Such exposures are known to cause and/or exacerbate chronic respiratory diseases, including chronic obstructive pulmonary disease (COPD) and asthma. However, there is a paucity of data regarding the status of systemic inflammation observed in exposed workers at brick manufacturing facilities within the country. In the current study, we sought to elucidate systemic inflammatory responses by quantifying the molecular cytokine/chemokine profiles in serum from the study participants. A sample of participants were screened from a kiln in Bhaktapur, Nepal (n = 32; 53% female; mean ± standard deviation: 28.42 ± 11.47 years old) and grouped according to job category. Blood was procured from participants on-site, allowed to clot at room temperature, and centrifuged to obtain total serum. A human cytokine antibody array was used to screen the inflammatory mediators in serum samples from each of the participants. For the current study, four job categories were evaluated with n = 8 for each. Comparisons were generated between a control group of administration workers vs. fire master workers, administration workers vs. green brick hand molders, and administration workers vs. top loaders. We discovered significantly increased concentrations of eotaxin-1, eotaxin-2, GCSF, GM-CSF, IFN-γ, IL-1α, IL-1ß, IL-6, IL-8, TGF-ß1, TNF-α, and TIMP-2 in serum samples from fire master workers vs. administration workers (p < 0.05). Each of these molecules was also significantly elevated in serum from green brick hand molders compared to administration workers (p < 0.05). Further, each molecule in the inflammatory screening with the exception of TIMP-2 was significantly elevated in serum from top loaders compared to administration workers (p < 0.05). With few exceptions, the fire master workers expressed significantly more systemic inflammatory molecular abundance when compared to all other job categories. These results reveal an association between pulmonary exposure to PM2.5 and systemic inflammatory responses likely mediated by cytokine/chemokine elaboration. The additional characterization of a broader array of inflammatory molecules may provide valuable insight into the susceptibility to lung diseases among this population.

3.
Cardiovasc Digit Health J ; 5(2): 70-77, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38765622

RESUMEN

Background: Patient monitoring devices are critical for alerting of potential cardiac arrhythmias during hospitalization; however, there are concerns of alarm fatigue due to high false alarm rates. Objective: The purpose of this study was to evaluate the sensitivity and false alarm rate of hospital-based continuous electrocardiographic (ECG) monitoring technologies. Methods: Six commonly used multiparameter bedside monitoring systems available in the United States were evaluated: B125M (GE HealthCare), ePM10 and iPM12 (Mindray), Efficia and IntelliVue (Philips), and Life Scope (Nihon Kohden). Sensitivity was tested using ECG recordings containing 57 true ventricular tachycardia (VT) events. False-positive rate testing used 205 patient-hours of ECG recordings containing no cardiac arrhythmias. Signals from ECG recordings were fed to devices simultaneously; high-severity arrhythmia alarms were tracked. Sensitivity to true VT events and false-positive rates were determined. Differences were assessed using Fisher exact tests (sensitivity) and Z-tests (false-positive rates). Results: B125M raised 56 total alarms for 57 annotated VT events and had the highest sensitivity (98%; P <.05), followed by iPM12 (84%), Life Scope (81%), Efficia (79%), ePM10 (77%), and IntelliVue (75%). B125M raised 20 false alarms, which was significantly lower (P <.0001) than iPM12 (284), Life Scope (292), IntelliVue (304), ePM10 (324), and Efficia (493). The most common false alarm was VT, followed by nonsustained VT. Conclusion: We found significant performance differences among multiparameter bedside ECG monitoring systems using previously collected recordings. B125M had the highest sensitivity in detecting true VT events and lowest false alarm rate. These results can assist in minimizing alarm fatigue and optimizing patient safety by careful selection of in-hospital continuous monitoring technology.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38676323

RESUMEN

BACKGROUND: The Integrated Care for Older People (ICOPE) approach was developed by the World Health Organization (WHO) aiming to shift the traditional focus of care based on diseases to a function- and person-centered approach, focused on maintaining and monitoring intrinsic capacity (IC). This study aimed to investigate the ability of the ICOPE screening tool to identify older people with clinically meaningful impairments in IC domains. METHODS: This cross-sectional analysis included 603 older adults, participants (mean age 74.7 [SD = 8.8] years, women 59.0%) of the INSPIRE Translational (INSPIRE-T) cohort. Responses at screening were compared to results of the subsequent in-depth assessment (ie, Mini-Mental State Examination, Mini Nutritional Assessment, Short Physical Performance Battery, Patient Health Questionnaire-9, and clinical investigation of vision problems) to determine its predictive capacity for impairments at the IC domains (ie, cognition, psychological, sensory (vision), vitality, and locomotion). RESULTS: The ICOPE screening items provided very high sensitivity for identifying abnormality in vision (97.2%) and varied from 42.0% to 69.6% for the other domains. High specificity (>70%) was observed for all the IC domains, except for vision (2.7%). CONCLUSIONS: The ICOPE screening tool can be a useful instrument enabling the identification of older people with impairments in IC domains, but studies with different populations are needed. It should be considered as a low-cost and simple screening tool in clinical care.


Asunto(s)
Evaluación Geriátrica , Humanos , Femenino , Anciano , Masculino , Estudios Transversales , Evaluación Geriátrica/métodos , Prestación Integrada de Atención de Salud , Tamizaje Masivo/métodos , Anciano de 80 o más Años , Valor Predictivo de las Pruebas , Estudios de Cohortes
5.
Maturitas ; 185: 107976, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38537388

RESUMEN

BACKGROUND: In 2015, the World Health Organization introduced the concept of intrinsic capacity (IC) to define the individual-level characteristics that enable an older person to be and do the things they value. This study developed an intrinsic capacity score for UK Biobank study participants and validated its use as a tool for health outcome prediction, understanding healthy aging trajectories, and genetic research. METHODS: Our analysis included data from 45,208 UK biobank participants who had a complete record of the ten variables included in the analysis. Factor adequacy was tested using Kaiser-Meyer-Olkin, Barthelt's, and the determinant of matrix tests, and the number of factors was determined by the parallel analysis method. Exploratory and confirmatory factor analyses were employed to determine the structure and dimensionality of indicators. Finally, the intrinsic capacity score was generated, and its construct and predictive validities as well as reliability were assessed. RESULTS: The factor analysis identified a multidimensional construct comprising one general factor (intrinsic capacity) and five specific factors (locomotor, vitality, cognitive, psychological, and sensory). The bifactor structure showed a better fit (comparative fit index = 0.995, Tucker Lewis index = 0.976, root mean square error of approximation = 0.025, root mean square residual = 0.009) than the conventional five-factor structure. The intrinsic capacity score generated using the bifactor confirmatory factor analysis has good construct validity, as demonstrated by an inverse association with age (lower intrinsic capacity in older age; (ß) =-0.035 (95%CI: -0.036, -0.034)), frailty (lower intrinsic capacity score in prefrail participants, ß = -0.104 (95%CI: (-0.114, -0.094)) and frail participants, ß = -0.227 (95%CI: -0.267, -0.186) than robust participants), and comorbidity (a lower intrinsic capacity score associated with increased Charlson's comorbidity index, ß =-0.019 (95%CI: -0.022, -0.015)). The intrinsic capacity score also predicted comorbidity (a one-unit increase in baseline intrinsic capacity score led to a lower Charlson's comorbidity index, ß = 0.147 (95%CI: -0.173, -0.121)) and mortality (a one-unit increase in baseline intrinsic capacity score led to 25 % lower risk of death, odds ratio = 0.75(95%CI: 0.663, 0.848)). CONCLUSION: The bifactor structure showed a better fit in all goodness of fit tests. The intrinsic capacity construct has strong structural, construct, and predictive validities and is a promising tool for monitoring aging trajectories.


Asunto(s)
Evaluación Geriátrica , Biobanco del Reino Unido , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cognición , Análisis Factorial , Envejecimiento Saludable , Reproducibilidad de los Resultados , Reino Unido
6.
J Occup Environ Hyg ; 21(4): 247-258, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38451548

RESUMEN

Exposure to respirable dust and crystalline silica (SiO2) has been linked to chronic obstructive pulmonary disease, silicosis, cancer, heart disease, and other respiratory diseases. Relatively few studies have measured respirable dust and SiO2 concentrations among workers at brick kilns in low- and middle-income countries. The purpose of this study was to measure personal breathing zone (PBZ) respirable dust and SiO2 concentrations among workers at one brick kiln in Bhaktapur, Nepal. A cross-sectional study was conducted among 49 workers in five job categories: administration, fire master, green (unfired) brick hand molder, green brick machine molder, and top loader. PBZ air samples were collected from each worker following Methods 0600 (respirable dust) and 7500 (respirable crystalline SiO2: cristobalite, quartz, tridymite) of the U.S. National Institute for Occupational Safety and Health. Eight-hour time-weighted average (TWA) respirable dust and quartz concentrations were also calculated. SiO2 percentage was measured in one bulk sample each of wet clay, the release agent used by green brick hand molders, and top coat soil at the brick kiln. The geometric mean (GM) sample and TWA respirable dust concentrations were 0.20 (95% confidence interval [CI]: 0.16, 0.27) and 0.12 (95% CI: 0.09, 0.16) mg/m3, respectively. GM sample and TWA quartz concentrations were 15.28 (95% CI: 11.11, 21.02) and 8.60 (95% CI: 5.99, 12.34) µg/m3, respectively. Job category was significantly associated with GM sample and TWA respirable dust and quartz concentrations (all p < 0.0001). Top loaders had the highest GM sample and TWA respirable dust concentrations of 1.49 and 0.99 mg/m3, respectively. Top loaders also had the highest GM sample and TWA quartz concentrations of 173.08 and 114.39 µg/m3, respectively. Quartz percentages in bulk samples were 16%-27%. Interventions including using wet methods to reduce dust generation, administrative controls, personal protective equipment, and education and training should be implemented to reduce brick kiln worker exposures to respirable dust and SiO2.


Asunto(s)
Contaminantes Ocupacionales del Aire , Exposición Profesional , Humanos , Dióxido de Silicio/análisis , Exposición Profesional/análisis , Cuarzo/análisis , Polvo/análisis , Contaminantes Ocupacionales del Aire/análisis , Nepal , Estudios Transversales , Exposición por Inhalación/análisis
7.
J Urban Health ; 101(1): 181-192, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38236430

RESUMEN

Pedestrian injuries from falls are an understudied cause of morbidity. Here, we compare the burden of pedestrian injuries from falls occurring on streets and sidewalks with that from motor vehicle collisions. Data on injurious falls on streets and sidewalks, and pedestrian-motor vehicle collisions, to which Emergency Medical Services responded, along with pedestrian and incident characteristics, were identified in the 2019 National Emergency Medical Services Information System database. In total, 118,520 injurious pedestrian falls and 33,915 pedestrians-motor vehicle collisions were identified, with 89% of the incidents occurring in urban areas. Thirty-two percent of pedestrians struck by motor vehicles were coded as Emergent or Critical by Emergency Medical Services, while 19% of pedestrians injured by falls were similarly coded. However, the number of pedestrians whose acuity was coded as Emergent or Critical was 2.1 times as high for injurious falls as compared with pedestrians-motor vehicle collisions. This ratio was 3.9 for individuals 50 years and older and 6.1 for those 65 years and older. In conclusion, there has been substantial and appropriate policy attention given to preventing pedestrian injuries from motor vehicles, but disproportionately little to pedestrian falls. However, the population burden of injurious pedestrian falls is significantly greater and justifies an increased focus on outdoor falls prevention, in addition to urban design, policy, and built environment interventions to reduce injurious falls on streets and sidewalks, than currently exists across the USA.


Asunto(s)
Peatones , Heridas y Lesiones , Humanos , Caminata , Accidentes de Tránsito , Vehículos a Motor , Entorno Construido , Heridas y Lesiones/epidemiología
8.
Nat Aging ; 4(1): 1-4, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38177328
9.
J Clin Monit Comput ; 38(1): 113-120, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37882880

RESUMEN

PURPOSE: Recent reports that pulse oximeters may overestimate oxygen saturation in individuals with darker skin pigmentation have prompted concerns from regulatory authorities regarding racial bias. We investigated the performance of TruSignal SpO2 sensors (GE Healthcare, Helsinki, Finland) in adults with varying skin pigmentation. METHODS: A retrospective study was conducted using a set of pooled assessments of SpO2/SaO2 measurements from nine studies to assess bias, accuracy (Arms), and precision of TruSignal sensors in healthy adults under induced hypoxia. Subgroup analyses were performed based on oxygen saturation levels (band 1, ≥ 70 and ≤ 80%; band 2, > 80 and ≤ 90%; band 3, > 90 and ≤ 100%). RESULTS: Of the 10,800 data points from 131 individuals, 8,202 (75.9%) and 2,598 (24.1%) were assigned to the light and dark pigment groups, respectively. Bias was 0.14% overall and less than 1% across oxygenation bands. The difference in bias between dark and light pigment groups was statistically significant at the low oxygenation band with SpO2 ≥ 70 and ≤ 80% (+ 0.58% and + 0.30% respectively; p = 0.0035). Throughout the saturation range, Arms was 1.64% in the light and 1.71% in the dark pigment group, within device specifications and regulatory requirements. Oxygenation was the dominating factor in stepwise ANOVA modeling. The mixed model also showed that bias was strongly affected by the oxygenation range. CONCLUSION: TruSignal sensors demonstrated higher bias at lower oxygen saturation, with less than 0.5% difference between pigment groups. These findings raise new questions, such as ways to improve pulse oximetry measurements during challenging clinical conditions, including low perfusion.


Asunto(s)
Oximetría , Pigmentación de la Piel , Adulto , Humanos , Estudios Retrospectivos , Oxígeno , Hipoxia/diagnóstico
10.
Ann Work Expo Health ; 68(2): 155-169, 2024 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-38124536

RESUMEN

BACKGROUND: Job-exposure matrices (JEMs) are often used for exposure assessment in occupational exposure and epidemiology studies. However, general population JEMs are difficult to find and access for workers in the United States of America. OBJECTIVE: We aimed to use publicly available information to develop a JEM-like exposure assessment method to determine exposure to a wide range of occupational agents in a wide range of occupations for US general population studies. METHODS: We used information from the US Department of Labor's Occupational Information Network database (O*NET) for 19,636 job tasks and 974 civilian occupations. We used automated keyword searches to identify 1,804 job tasks that involved exposure to 50 occupational agents. We had 2 reviewers determine whether each identified job task actually involved exposure to the 50 occupational agents. We had a third reviewer, a certified industrial hygienist, assess any job task and exposure for which the first 2 reviewers disagreed. For each U.S. Census 2010 occupation code, we used this information to derive 3 exposure variables for each occupational agent: ever exposure, number of job tasks of exposure, and frequency of exposure. RESULTS: Our keyword searches identified a median of 10 (interquartile range [IQR]: 43.75) job tasks for each occupational agent, and the maximum was 308. We determined job tasks actually involved exposure to 45 occupational agents, including solvents, air pollution, pesticides, radiation, metals, etc. We derived the 3 exposure variables for these 45 occupational agents for 516 U.S. Census 2010 occupation codes. The median percentage for ever exposure to individual occupational agents was 1.16% (IQR: 1.74%), and the maximum was 11.43%. CONCLUSIONS: Our JEM-like exposure assessment method based on O*NET information can be used to determine exposure to a wide range of occupational agents in a wide range of occupations for the US general population.


Asunto(s)
Exposición Profesional , Humanos , Estados Unidos , Exposición Profesional/análisis , Ocupaciones , Industrias , Metales , Servicios de Información
12.
Res Sq ; 2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37609339

RESUMEN

Pedestrian injuries from falls are an understudied cause of morbidity. Here we compare the burden of pedestrian injuries from falls occurring on streets and sidewalks with that from motor vehicle collisions. Data on injurious falls on streets and sidewalks, and pedestrian-motor vehicle collisions, to which Emergency Medical Services responded, along with pedestrian and incident characteristics, were identified in the 2019 National Emergency Medical Services Information System database. In total, 129,343 injurious falls and 33,910 pedestrians-motor vehicle collisions were identified, with 89% of the incidents occurring in urban areas. Thirty two percent of pedestrians struck by motor vehicles were coded as Emergent or Critical by Emergency Medical Services, while 20% of pedestrians injured by falls were similarly coded. However, the number of pedestrians whose acuity was coded as Emergent or Critical was 2.33 times as high for injurious falls as compared with pedestrians-motor vehicle collisions. This ratio was nearly double at 4.3 for individuals 50 years and older, and almost triple at 6.5 for those 65 years and older. In conclusion, there has been substantial and appropriate policy attention given to preventing pedestrian injuries from motor vehicles, but disproportionately little to pedestrian falls. However, the population burden of injurious pedestrian falls is significantly greater and justifies an increased focus on outdoor falls prevention, in addition to urban design, policy and built environment interventions to reduce injurious falls on streets and sidewalks, than currently exists across the U.S.

13.
Curr Probl Cardiol ; 48(12): 102011, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37544624

RESUMEN

Accurate ECG interpretation is vital, but variations in skills exist among healthcare professionals. This study aims to identify factors contributing to ECG interpretation proficiency. Survey data and ECG interpretation test scores from participants in the EDUCATE Trial were analyzed to identify predictors of performance for 30 sequential 12-lead ECGs. Nonmodifiable factors (being a physician, clinical experience, patient care impact) and modifiable factors (weekly interpretation volume, training hours, expert supervision frequency) were analyzed. Bivariate and multivariate analyses were used to generate a Comprehensive Model (incorporating all factors) and Actionable Model (incorporating modifiable factors only). Among 1206 participants analyzed, there were 72 (6.0%) primary care physicians, 146 (12.1%) cardiology fellows-in-training, 353 (29.3%) resident physicians, 182 (15.1%) medical students, 84 (7.0%) advanced practice providers, 120 (9.9%) nurses, and 249 (20.7%) allied health professionals. Among them, 571 (47.3%) were physicians and 453 (37.6%) were nonphysicians. The average test score was 56.4% ± 17.2%. Bivariate analysis demonstrated significant associations between test scores and >10 weekly ECG interpretations, being a physician, >5 training hours, patient care impact, and expert supervision but not clinical experience. In the Comprehensive Model, independent associations were found with weekly interpretation volume (9.9 score increase; 95% CI, 7.9-11.8; P < 0.001), being a physician (9.0 score increase; 95% CI, 7.2-10.8; P < 0.001), and training hours (5.7 score increase; 95% CI, 3.7-7.6; P < 0.001). In the Actionable Model, scores were independently associated with weekly interpretation volume (12.0 score increase; 95% CI, 10.0-14.0; P < 0.001) and training hours (4.7 score increase; 95% CI, 2.6-6.7; P < 0.001). The Comprehensive and Actionable Models explained 18.7% and 12.3% of the variance in test scores, respectively. Predictors of ECG interpretation proficiency include nonmodifiable factors like physician status and modifiable factors such as training hours and weekly ECG interpretation volume.


Asunto(s)
Competencia Clínica , Electrocardiografía , Humanos , Encuestas y Cuestionarios , Atención a la Salud
14.
Curr Probl Cardiol ; 48(11): 101989, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37482286

RESUMEN

The interpretation of electrocardiograms (ECGs) involves a dynamic interplay between computerized ECG interpretation (CEI) software and human overread. However, the impact of computer ECG interpretation on the performance of healthcare professionals remains largely unexplored. The aim of this study was to evaluate the interpretation proficiency of various medical professional groups, with and without access to the CEI report. Healthcare professionals from diverse disciplines, training levels, and countries sequentially interpreted 60 standard 12-lead ECGs, demonstrating both urgent and nonurgent findings. The interpretation process consisted of 2 phases. In the first phase, participants interpreted 30 ECGs with clinical statements. In the second phase, the same 30 ECGs and clinical statements were randomized and accompanied by a CEI report. Diagnostic performance was evaluated based on interpretation accuracy, time per ECG (in seconds [s]), and self-reported confidence (rated 0 [not confident], 1 [somewhat confident], or 2 [confident]). A total of 892 participants from various medical professional groups participated in the study. This cohort included 44 (4.9%) primary care physicians, 123 (13.8%) cardiology fellows-in-training, 259 (29.0%) resident physicians, 137 (15.4%) medical students, 56 (6.3%) advanced practice providers, 82 (9.2%) nurses, and 191 (21.4%) allied health professionals. The inclusion of the CEI was associated with a significant improvement in interpretation accuracy by 15.1% (95% confidence interval, 14.3-16.0; P < 0.001), decrease in interpretation time by 52 s (-56 to -48; P < 0.001), and increase in confidence by 0.06 (0.03-0.09; P = 0.003). Improvement in interpretation accuracy was seen across all professional subgroups, including primary care physicians by 12.9% (9.4-16.3; P = 0.003), cardiology fellows-in-training by 10.9% (9.1-12.7; P < 0.001), resident physicians by 14.4% (13.0-15.8; P < 0.001), medical students by 19.9% (16.8-23.0; P < 0.001), advanced practice providers by 17.1% (13.3-21.0; P < 0.001), nurses by 16.2% (13.4-18.9; P < 0.001), allied health professionals by 15% (13.4-16.6; P < 0.001), physicians by 13.2% (12.2-14.3; P < 0.001), and nonphysicians by 15.6% (14.3-17.0; P < 0.001).CEI integration improves ECG interpretation accuracy, efficiency, and confidence among healthcare professionals.


Asunto(s)
Médicos , Humanos , Electrocardiografía , Computadores , Atención a la Salud
15.
J Cachexia Sarcopenia Muscle ; 14(5): 2054-2063, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37434422

RESUMEN

BACKGROUND: The World Health Organization proposed the concept of intrinsic capacity (IC; the composite of all the physical and mental capacities of the individual) as central for healthy ageing. However, little research has investigated the interaction and joint associations of IC with cardiovascular disease (CVD) incidence and CVD mortality in middle- and older-aged adults. METHODS: Using data from 443 130 UK Biobank participants, we analysed seven biomarkers capturing the level of functioning of five domains of IC to calculate a total IC score (ranging from 0 [better IC] to +4 points [poor IC]). Associations between IC score and incidence of six long-term CVD conditions (hypertension, stroke/transient ischaemic attack stroke, peripheral vascular disease, atrial fibrillation/flutter, coronary artery disease and heart failure), and grouped mortality from these conditions were estimated using Cox proportional models, with a 1-year landmark analysis to triangulate the findings. RESULTS: Over 10.6 years of follow-up, CVD morbidity grouped (n = 384 380 participants for the final analytic sample) was associated with IC scores (0 to +4): mean hazard ratio (HR) [95% confidence interval, CI] 1.11 [1.08-1.14], 1.20 [1.16-1.24], 1.29 [1.23-1.36] and 1.56 [1.45-1.59] in men (C-index = 0.68), and 1.17 [1.13-1.20], 1.30 [1.26-1.36], 1.52 [1.45-1.59] and 1.78 [1.67-1.89] in women (C-index = 0.70). In regard to mortality, our results indicated that the higher IC score (+4 points) was associated with a significant increase in subsequent CVD mortality (mean HR [95% CI]: 2.10 [1.81-2.43] in men [C-index = 0.75] and 2.29 [1.85-2.84] in women [C-index = 0.78]). Results of all sensitivity analyses by full sample, sex and age categories were largely consistent independent of major confounding factors (P < 0.001). CONCLUSIONS: IC deficit score is a powerful predictor of functional trajectories and vulnerabilities of the individual in relation to CVD incidence and premature death. Monitoring an individual's IC score may provide an early-warning system to initiate preventive efforts.

16.
Curr Probl Cardiol ; 48(10): 101865, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37321283

RESUMEN

The electrocardiogram (ECG) is a crucial diagnostic tool in medicine with concerns about its interpretation proficiency across various medical disciplines. Our study aimed to explore potential causes of these issues and identify areas requiring improvement. A survey was conducted among medical professionals to understand their experiences with ECG interpretation and education. A total of 2515 participants from diverse medical backgrounds were surveyed. A total of 1989 (79%) participants reported ECG interpretation as part of their practice. However, 45% expressed discomfort with independent interpretation. A significant 73% received less than 5 hours of ECG-specific education, with 45% reporting no education at all. Also, 87% reported limited or no expert supervision. Nearly all medical professionals (2461, 98%) expressed a desire for more ECG education. These findings were consistent across all groups and did not vary between primary care physicians, cardiology FIT, resident physicians, medical students, APPs, nurses, physicians, and nonphysicians. This study reveals substantial deficiencies in ECG interpretation training, supervision, and confidence among medical professionals, despite a strong interest in increased ECG education.


Asunto(s)
Cardiología , Humanos , Electrocardiografía , Competencia Clínica
17.
J Clin Monit Comput ; 37(6): 1451-1461, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37266709

RESUMEN

To compare pulse oximetry performance during simulated conditions of motion and low perfusion in three commercially available devices: GE HealthCare CARESCAPE ONE TruSignal SpO2 Parameter, Masimo RADICAL-7 and Medtronic Nellcor PM1000N. After IRB approval, 28 healthy adult volunteers were randomly assigned to the motion group (N = 14) or low perfusion (N = 14) group. Pulse oximeters were placed on the test and control hands using random assignment of digits 2-5. Each subject served as their own control through the series of repeated pair-wise measurements. Reference co-oximetry oxyhemoglobin (SaO2) measurements from the radial artery were also obtained in the motion group. SpO2 readings were compared between the test and control hands in both groups and to SaO2 measurements in the motion group. Accuracy was assessed through testing of accuracy root-mean squared (ARMS) and mean bias. In the simulated motion test group the overall Accuracy Root Mean Square (ARMS) versus SaO2 was 1.88 (GE), 1.79 (Masimo) and 2.40 (Nellcor), with overall mean bias of - 0.21 (Masimo), 0.45 (GE), and 0.78 (Nellcor). In the motion hand, ARMS versus SaO2 was 2.45 (GE), 3.19 (Masimo) and 4.15 (Nellcor), with overall mean bias of - 0.75 (Masimo), - 0.01 (GE), and 0.04 (Nellcor). In the low perfusion test group, ARMS versus the control hand SpO2 for low PI was 3.24 (GE), 3.48 (Nellcor) and 4.76 (Masimo), with overall bias measurements of - 0.53 (Nellcor), 0.96 (GE) and 1.76 (Masimo). Experimental results for all tested devices met pulse oximetry regulatory and testing standards requirements. Overall, SpO2 device performance across the three devices in this study was similar under both motion and low perfusion conditions. SpO2 measurement accuracy degraded for all three devices during motion as compared to non-motion. Accuracy also degraded during normal to low, very low, or ultra low perfusion and was more pronounced compared to the changes observed during simulated motion. While some statistically significant differences in individual measurements were found, the clinical relevance of these differences requires further study.


Asunto(s)
Oximetría , Oxígeno , Adulto , Humanos , Mano , Movimiento (Física) , Oximetría/métodos , Perfusión
19.
J Med Econ ; 26(1): 760-768, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37249124

RESUMEN

OBJECTIVE: This study aimed to determine the potential cost-savings for implementing continuous vital sign monitoring in a hospital's medical-surgical units. METHODS: A cost-savings analysis was designed to calculate potential cost-savings for an average-sized U.S. community hospital (153 total beds) over a 1-year time horizon. Analysis parameters were extracted from national databases and previous studies that compared outcomes for patients receiving continuous vital sign monitoring (SpO2, HR, and RR) or standard of care (intermittent vital sign measurements) in medical-surgical units based on a targeted literature review. Clinical parameters and associated costs served as analysis inputs. The analysis outputs were costs and potential cost-savings using a 50% and 100% adoption rate of continuous monitoring technologies across the medical-surgical unit. RESULTS: Potential annual cost-savings for in-hospital medical-surgical stays were estimated at $3,414,709 (2022 USD) and $6,829,418 for a 50% and 100% adoption rate, respectively. The cost-savings for an adoption rate of 100% equated to a ∼14% reduction in the overall annual cost of medical-surgical unit stays for an average-sized hospital. The largest contribution to potential cost-savings came from patients that avoided serious adverse events that require transfer to the intensive care unit; this resulted in annual cost-savings from reduced average length of stay between $1,756,613 and $3,513,226 (50% and 100% adoption rate, respectively). Additional cost-savings can be attained from reductions in in-hospital cardiac arrest-associated hospitalizations and decreased rapid response team activation. CONCLUSIONS: Our findings demonstrate that there is the potential for cost-savings of over $6.8 million dollars per year in an average-sized US community hospital by improving patient outcomes through implementation of continuous monitoring technologies in medical-surgical units. Continuous vital sign monitoring technologies that increase patient mobility and facilitate recovery may further contribute to cost-savings and should be considered for economic analyses. Future research is needed to explore these health-related outcomes.


Asunto(s)
Hospitalización , Unidades de Cuidados Intensivos , Humanos , Ahorro de Costo/métodos , Tiempo de Internación , Signos Vitales
20.
Bull World Health Organ ; 101(5): 307-316C, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37131938

RESUMEN

Objective: To investigate the contribution of early-life factors on intrinsic capacity of Chinese adults older than 45 years. Methods: We used data on 21 783 participants from waves 1 (2011) and 2 (2013) of the China Health and Retirement Longitudinal Study (CHARLS), who also participated in the 2014 CHARLS Life History Survey to calculate a previously validated measure of intrinsic capacity. We considered 11 early-life factors and investigated their direct association with participants' intrinsic capacity later in life, as well as their indirect association through four current socioeconomic factors. We used multivariable linear regression and the decomposition of the concentration index to investigate the contribution of each determinant to intrinsic capacity inequalities. Findings: Participants with a favourable environment in early life (that is, parental education, childhood health and neighbourhood environment) had a significantly higher intrinsic capacity score in later life. For example, participants with a literate father recorded a 0.040 (95% confidence interval, CI: 0.020 to 0.051) higher intrinsic capacity score than those with an illiterate father. This inequality was greater for cognitive, sensory and psychological capacities than locomotion and vitality. Overall, early-life factors directly explained 13.92% (95% CI: 12.07 to 15.77) of intrinsic capacity inequalities, and a further 28.57% (95% CI: 28.19 to 28.95) of these inequalities through their influence on current socioeconomic inequalities. Conclusion: Unfavourable early-life factors appear to decrease late-life health status in China, particularly cognitive, sensory and psychological capacities, and these effects are exacerbated by cumulative socioeconomic inequalities over a person's life course.


Asunto(s)
Envejecimiento Saludable , Acontecimientos que Cambian la Vida , Niño , Humanos , China , Estudios Longitudinales , Factores Socioeconómicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...