Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
J Clin Oncol ; 42(10): 1102-1109, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38194613

RESUMEN

PURPOSE: The Normal Risk Ovarian Screening Study (NROSS) tested a two-stage screening strategy in postmenopausal women at conventional hereditary risk where significantly rising cancer antigen (CA)-125 prompted transvaginal sonography (TVS) and abnormal TVS prompted surgery to detect ovarian cancer. METHODS: A total of 7,856 healthy postmenopausal women were screened annually for a total of 50,596 woman-years in a single-arm study (ClinicalTrials.gov identifier: NCT00539162). Serum CA125 was analyzed with the Risk of Ovarian Cancer Algorithm (ROCA) each year. If risk was unchanged and <1:2,000, women returned in a year. If risk increased above 1:500, TVS was undertaken immediately, and if risk was intermediate, CA125 was repeated in 3 months with a further increase in risk above 1:500 prompting referral for TVS. An average of 2% of participants were referred to TVS annually. RESULTS: Thirty-four patients were referred for operations detecting 15 ovarian cancers and two borderline tumors with 12 in early stage (I-II). In addition, seven endometrial cancers were detected with six in stage I. As four ovarian cancers and two borderline tumors were diagnosed with a normal ROCA, the sensitivity for detecting ovarian and borderline cancer was 74% (17 of 23), and 70% of ROCA-detected cases (12 of 17) were in stage I-II. NROSS screening reduced late-stage (III-IV) disease by 34% compared with UKCTOCS controls and by 30% compared with US SEER values. The positive predictive value (PPV) was 50% (17 of 34) for detecting ovarian cancer and 74% (25 of 34) for any cancer, far exceeding the minimum acceptable study end point of 10% PPV. CONCLUSION: While the NROSS trial was not powered to detect reduced mortality, the high specificity, PPV, and marked stage shift support further development of this strategy.


Asunto(s)
Neoplasias Endometriales , Neoplasias Ováricas , Humanos , Femenino , Neoplasias Ováricas/diagnóstico por imagen , Valor Predictivo de las Pruebas , Tamizaje Masivo , Ultrasonografía , Antígeno Ca-125
2.
Curr Oncol ; 30(9): 8375-8385, 2023 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-37754523

RESUMEN

Transabdominal ultrasound is a promising imaging modality for pancreatic cystic lesions. This study aims to determine if transabdominal ultrasonography with CT fusion (TAUS-f) using volume navigation can be used to measure pancreatic cystic lesions (PCLs) compared to CT alone. We evaluated 33 patients prospectively with known PCLs. The readers evaluated each PCL's size and imaging characteristics on TAUS-f and CT alone. These were compared to endoscopic ultrasonography reports. A total of 43 PCLs from 32 patients were evaluated. The detection rate by TAUS-f was 93%. Two of the three undetected PCLs were in the tail of the pancreas. Inter-reader variabilities for TAUS-f and CT were 0.005 cm and 0.03 cm, respectively. Subgroup analysis by size and location demonstrated that inter-modality variability between TAUS-f and CT was smallest for lesions < 1.5 cm with a size difference of -0.13 cm for each reader and smallest in the pancreatic head with a size difference of -0.16 cm and -0.17 cm for readers 1 and 2. We found that TAUS-f effectively evaluates PCLs compared to CT alone, thus suggesting that it should be considered part of the surveillance algorithm for a subset of patients.


Asunto(s)
Páncreas , Quiste Pancreático , Humanos , Ultrasonografía , Tomografía Computarizada por Rayos X , Algoritmos , Quiste Pancreático/diagnóstico por imagen
3.
Vasc Med ; 27(4): 365-372, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35502899

RESUMEN

BACKGROUND: Thrombosis of the left internal jugular vein in an astronaut aboard the International Space Station was recently described, incidentally discovered during a research study of blood flow in neck veins in microgravity. Given this event, and the high incidence of flow abnormalities, the National Aeronautics and Space Administration (NASA) instituted an occupational surveillance program to evaluate astronauts for venous thrombosis. METHODS: Duplex ultrasound of the bilateral internal jugular veins was conducted on all NASA astronauts terrestrially, and at three points during spaceflight. Respiratory maneuvers were performed. Images were analyzed for thrombosis and certain hemodynamic characteristics, including peak velocity and degree of echogenicity. RESULTS: Eleven astronauts were evaluated with matching terrestrial and in-flight ultrasounds. No thrombosis was detected. Compared to terrestrial ultrasound measurements, in-flight peak velocity was reduced and lowest in the left. Six of 11 astronauts had mild-moderate echogenicity in the left internal jugular vein during spaceflight, but none had more than mild echogenicity in the right internal jugular vein. Two astronauts developed retrograde blood flow in the left internal jugular vein. CONCLUSION: Abnormal flow characteristics in microgravity, most prominent in the left internal jugular vein, may signal an increased risk for thrombus formation in some individuals.


Asunto(s)
Vuelo Espacial , Trombosis , Trombosis de la Vena , Ingravidez , Astronautas , Humanos , Venas Yugulares/diagnóstico por imagen , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/etiología , Ingravidez/efectos adversos
4.
J Endourol ; 32(9): 806-811, 2018 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-30014707

RESUMEN

INTRODUCTION: Staging of upper tract urothelial carcinoma (UTUC) remains a dilemma due to imaging and biopsy limitations leading to understaging. We seek to determine the accuracy of endoluminal ultrasound (ELUS) for clinical staging of UTUC. MATERIALS AND METHODS: Patients evaluated for UTUC underwent retrograde pyelography, ureteroscopy, and ELUS. ELUS was performed using mechanical radial scanning at 20 MHz in B-mode with a 5F probe. Cine clips were evaluated by 2 radiologists blinded to ureteroscopic and pathology findings. Results were compared to pathology from nephroureterectomy. Inclusion criteria were patients who underwent nephroureterectomy without pretreatment or managed endoscopically for cTa-1 disease and were without recurrence for >1 year. RESULTS: From 2008 to 2013, 53 patients underwent ELUS without complication. Twenty-seven patients met inclusion criteria with conclusive ELUS imaging. ELUS accurately identified 16 of 21 patients with non-muscle invasive (MI) disease (18 pTa, 2 pT1, 1 CIS) and 1 of 6 patients with at least MI disease (2 pT2, 4 pT3). For MI disease, the positive predictive value (PPV), negative predictive value, and accuracy was 76.2%, 16.7%, and 63%, respectively, while for non-organ confined (OC) disease results were 0%, 81.8%, and 66.7%, respectively. CONCLUSIONS: With current technique and instrumentation, ELUS may prove useful in select cases to confirm findings of non-MI and OC disease. However, it has insufficient PPV for stage pT2-3 disease. Further studies and better instrumentation are needed before incorporation into clinical practice.


Asunto(s)
Carcinoma de Células Transicionales/diagnóstico por imagen , Estadificación de Neoplasias/métodos , Ultrasonografía/métodos , Neoplasias Urológicas/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Ureteroscopía/métodos
5.
J Ultrasound Med ; 36(9): 1867-1874, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28470976

RESUMEN

OBJECTIVES: To determine whether the qualitative sonographic appearance of slow deep venous flow in the lower extremities correlates with quantitative slow flow and an increased risk of deep venous thrombosis (DVT) in oncology patients. METHODS: In this Institutional Review Board-approved retrospective study, we reviewed lower extremity venous Doppler sonographic examinations of 975 consecutive patients: 482 with slow flow and 493 with normal flow. The subjective slow venous flow and absence of initial DVT were confirmed by 2 radiologists. Peak velocities were recorded at 3 levels. Each patient was followed for DVT development. The associations between DVT and the presence of slow venous flow were examined by the Fisher exact test; a 2-sample t test was used for peak velocity and DVT group comparisons. The optimal cutoff peak velocity for correlation with the radiologists' perceived slow flow was determined by the Youden index. RESULTS: Deep venous thrombosis development in the slow-flow group (21 of 482 [4.36%]) was almost doubled compared with patients who had normal flow (11 of 493 [2.23%]; P = .0456). Measured peak venous velocities were lower in the slow-venous flow group (P < .001). Patients with subsequent DVT did not have a significant difference in venous velocities compared with their respective patient groups. The sum of 3 venous level velocities resulted in the best cutoff for dichotomizing groups into normal versus slow venous flow. CONCLUSIONS: Qualitative slow venous flow in the lower extremities on Doppler sonography accurately correlates with quantitatively slower flow, and this preliminary evaluation suggests an associated mildly increased rate of subsequent DVT development in oncology patients.


Asunto(s)
Extremidad Inferior/irrigación sanguínea , Centros de Atención Terciaria , Ultrasonografía Doppler/métodos , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/fisiopatología , Velocidad del Flujo Sanguíneo/fisiología , Estudios de Evaluación como Asunto , Femenino , Humanos , Extremidad Inferior/fisiopatología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Atención Terciaria de Salud/métodos
6.
J Ultrasound Med ; 36(8): 1547-1553, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28390143

RESUMEN

OBJECTIVES: To determine the feasibility of obtaining intraoperative contrast-enhanced ultrasound (CEUS) imaging in patients undergoing open partial nephrectomy for renal cancer. We hypothesize that the study was feasible and the addition of CEUS would improve lesion identification and characterization. METHODS: The study population consisted of 10 patients with known renal mass scheduled for intraoperative ultrasound-guided open partial nephrectomy. After dissection and exposure of the kidney by the surgeon, an intraoperative pre- and post-CEUS was performed by the radiologist. Feasibility was defined as successful imaging in 8 of 10 patients with intraoperative CEUS. Image quality, lesion conspicuity/contrast, lesion vascularity, morphology, and size were assessed and graded with pre- and post-contrast images. RESULTS: Intraoperative ultrasound was successfully acquired in 10 of 11 patients for renal mass detection and characterization. One study was canceled intraoperatively as a result of clinical complications related to a difficult surgery. Tumor size ranged from 1.3 to 4.2 cm. All lesions were solid. No additional lesions were found on CEUS compared with baseline imaging. Image quality post-contrast ranged from acceptable to excellent. There were no adverse events recorded for all 10 patients. CONCLUSIONS: In our feasibility study consisting of 10 patients, CEUS for detection and characterization of renal mass undergoing open partial nephrectomy was feasible and safe. Because intraoperative ultrasound during open partial nephrectomy can affect the extent of surgery, CEUS can be used to help detect and characterize renal mass for surgical planning/resection intraoperatively.


Asunto(s)
Medios de Contraste , Aumento de la Imagen/métodos , Cuidados Intraoperatorios/métodos , Neoplasias Renales/diagnóstico por imagen , Nefrectomía , Ultrasonografía/métodos , Adulto , Anciano , Estudios de Factibilidad , Femenino , Humanos , Riñón/diagnóstico por imagen , Riñón/cirugía , Neoplasias Renales/cirugía , Masculino , Persona de Mediana Edad
7.
AJR Am J Roentgenol ; 203(4): 822-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25247947

RESUMEN

OBJECTIVE: The purpose of this study is to evaluate whether intraoperative ultrasound (IOUS) during open partial nephrectomy alters the surgical management for renal cell cancer (RCC). MATERIALS AND METHODS: One hundred ninety-eight consecutive patients undergoing IOUS during open partial nephrectomy for RCC were selected for retrospective review of clinical and imaging data. Patient age and sex, the local extent of the primary lesion, and the presence of additional lesions were recorded. Ultrasound findings were compared with preoperative CT or MRI to determine whether the IOUS findings changed surgical management. Summary statistics were performed to assess what percentage of patients with additional IOUS findings had a change in their surgical management. The Kaplan-Meier method was used to estimate 5-year overall survival (OS) and event-free survival (EFS) rates for all patients. Patients were followed for 9-12 years to assess survival and measure recurrence rates. RESULTS: Twenty-one of 198 patients (10.6%; 95% CI, 6.7-15.8%) had additional findings on IOUS not seen on preoperative imaging. As a result, surgery was modified in 15 of these 21 patients (71.4%; 95% CI, 47.8-88.7%). The 5-year OS rate was 81%, and the EFS rate was 76% for the whole group; most deaths were due to unrelated causes. There was no statistically significant difference in OS (p = 0.867) and EFS (p = 0.069) rates among patients who had a change of management because of additional lesions seen by IOUS. CONCLUSION: IOUS performed during open partial nephrectomy for resection of RCC shows additional findings compared with preoperative cross-sectional imaging that may alter surgical management.


Asunto(s)
Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/cirugía , Cuidados Intraoperatorios/mortalidad , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Cirugía Asistida por Computador/mortalidad , Ultrasonografía/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Renales/mortalidad , Supervivencia sin Enfermedad , Femenino , Humanos , Neoplasias Renales/mortalidad , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Texas/epidemiología , Resultado del Tratamiento
8.
Cancer ; 119(19): 3454-61, 2013 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-23983047

RESUMEN

BACKGROUND: A 2-stage ovarian cancer screening strategy was evaluated that incorporates change of carbohydrate antigen 125 (CA125) levels over time and age to estimate risk of ovarian cancer. Women with high-risk scores were referred for transvaginal ultrasound (TVS). METHODS: A single-arm, prospective study of postmenopausal women was conducted. Participants underwent an annual CA125 blood test. Based on the Risk of Ovarian Cancer Algorithm (ROCA) result, women were triaged to next annual CA125 test (low risk), repeat CA125 test in 3 months (intermediate risk), or TVS and referral to a gynecologic oncologist (high risk). RESULTS: A total of 4051 women participated over 11 years. The average annual rate of referral to a CA125 test in 3 months was 5.8%, and the average annual referral rate to TVS and review by a gynecologic oncologist was 0.9%. Ten women underwent surgery on the basis of TVS, with 4 invasive ovarian cancers (1 with stage IA disease, 2 with stage IC disease, and 1 with stage IIB disease), 2 ovarian tumors of low malignant potential (both stage IA), 1 endometrial cancer (stage I), and 3 benign ovarian tumors, providing a positive predictive value of 40% (95% confidence interval = 12.2%, 73.8%) for detecting invasive ovarian cancer. The specificity was 99.9% (95% confidence interval = 99.7%, 100%). All 4 women with invasive ovarian cancer were enrolled in the study for at least 3 years with low-risk annual CA125 test values prior to rising CA125 levels. CONCLUSIONS: ROCA followed by TVS demonstrated excellent specificity and positive predictive value in a population of US women at average risk for ovarian cancer.


Asunto(s)
Antígeno Ca-125/sangre , Neoplasias Ováricas/sangre , Anciano , Algoritmos , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias , Neoplasias Ováricas/epidemiología , Neoplasias Ováricas/patología , Posmenopausia/sangre , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Riesgo , Estados Unidos/epidemiología
9.
J Neuroophthalmol ; 33(3): 249-55, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23851997

RESUMEN

BACKGROUND: A number of ophthalmic findings including optic disc edema, globe flattening, and choroidal folds have been observed in several astronauts after long-duration space flights. The authors report the first astronaut with previously documented postflight ophthalmic abnormalities who developed new pathological changes after a repeat long-duration mission. METHODS: A case study of an astronaut with 2 long-duration (6 months) exposures to microgravity. Before and after his first long-duration space flight, he underwent complete eye examination, including fundus photography. Before and after his second flight, 9 years later, he underwent fundus photography, optical coherence tomography, ocular ultrasonography, and brain magnetic resonance imaging, as well as in-flight fundus photography and ultrasound. RESULTS: After his first long-duration mission, the astronaut was documented to have eye findings limited to unilateral choroidal folds and a single cotton wool spot. During a subsequent 6-month mission, he developed more widespread choroidal folds and new onset of optic disc edema in the same eye. CONCLUSION: Microgravity-induced anatomical changes that occurred during the first mission may have set the stage for recurrent or additional changes when the astronaut was subjected to physiological stress of repeat space flight.


Asunto(s)
Astronautas , Papiledema/etiología , Vuelo Espacial , Ingravidez/efectos adversos , Humanos , Masculino , Persona de Mediana Edad
10.
World J Radiol ; 5(3): 51-60, 2013 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-23671741

RESUMEN

Significant advances in ultrasound technology have created new opportunities for its use in oncologic imaging. The advent of new transducers with focal beam technology and higher frequency has solidified the role of intraoperative sonography (IOUS) as an invaluable imaging modality in oncologic surgery of the liver, kidneys and pancreas. The ability to detect and characterize small lesions and the precise intraoperative localization of such tumors is essential for adequate surgical planning in segmental or lobar hepatic resections, metastasectomy, nephron-sparing surgery, and partial pancreatectomy. Also, diagnostic characterization of small equivocal lesions deemed indeterminate by conventional preoperative imaging such as multidetector computed tomography or magnetic resonance imaging, has become an important application of IOUS. This article will review the current applications of IOUS in the liver, kidneys and pancreas.

11.
World J Radiol ; 5(3): 81-7, 2013 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-23671744

RESUMEN

Sonohysterography (SHG), which provides enhanced endometrial visualization during standard transvaginal ultrasonography, is a relatively safe procedure for the evaluation of endometrial pathology. It can be used to evaluate patients with abnormal vaginal bleeding or infertility. This modality offers real time imaging of the endometrium without exposure to ionizing radiation. SHG is typically used in patients for whom standard transvaginal ultrasonography does not show the endometrium well, show a potential abnormality for which further imaging is required, or in patients without endometrial pathology defined on routine transvaginal imaging but in whom there is a strong clinical suspicion of an abnormality. This article will discuss the utility of the sonohysterogram in evaluation of various endometrial pathologies. Imaging examples of these pathological entities will be illustrated as well.

12.
World J Radiol ; 5(3): 113-25, 2013 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-23671748

RESUMEN

Ovarian cystic masses include a spectrum of benign, borderline and high grade malignant neoplasms. Imaging plays a crucial role in characterization and pretreatment planning of incidentally detected or suspected adnexal masses, as diagnosis of ovarian malignancy at an early stage is correlated with a better prognosis. Knowledge of differential diagnosis, imaging features, management trends and an algorithmic approach of such lesions is important for optimal clinical management. This article illustrates a multi-modality approach in the diagnosis of a spectrum of ovarian cystic masses and also proposes an algorithmic approach for the diagnosis of these lesions.

13.
J Pain Symptom Manage ; 44(2): 181-91, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22695045

RESUMEN

CONTEXT: In pancreatic cancer, the presence of obesity or weight loss is associated with higher mortality. OBJECTIVES: To explore the relationships among body mass index, longitudinal body composition alterations, and clinical outcomes in pancreatic cancer patients. METHODS: Records of 41 patients with inoperable locally advanced pancreatic cancer who participated in a prospective chemoradiation study were reviewed. Body composition was analyzed from two sets of computed tomography images obtained before and after radiation treatment (median interval 104 days). RESULTS: Median age was 59 years and 56% of patients were female. Twenty-four (59%) patients were either overweight (22%) or obese (37%). Sarcopenia was present in 26 (63%) patients. At follow-up, weight loss was experienced by 33 (81%) patients. The median losses (%) before and after treatment were weight 5% (P<0.001), skeletal muscle (SKM) 4% (P=0.003), visceral adipose tissue (VAT) 13% (P<0.001), and subcutaneous adipose tissue 11% (P=0.002). SKM loss positively correlated with age (P=0.03), baseline body mass index (P<0.001), and VAT (P=0.04) index. Obese patients experienced higher losses in weight (P=0.009), SKM (P=0.02), and VAT (P=0.02). Median survival was 12 months. In univariate analysis, age, baseline obesity, sarcopenic obesity, and losses (%) in weight, SKM, and VAT were associated with worse survival. In multivariate analysis, only age (hazard ratio=1.033, P=0.04) and higher VAT loss (hazard ratio=2.6 and P=0.03) remained significant. CONCLUSION: Our preliminary findings suggest that obese patients experience higher losses in weight, SKM, and VAT, which may contribute to poorer survival in these patients.


Asunto(s)
Composición Corporal/fisiología , Índice de Masa Corporal , Quimioradioterapia , Neoplasias Pancreáticas/patología , Neoplasias Pancreáticas/terapia , Tejido Adiposo/patología , Adulto , Anciano , Anciano de 80 o más Años , Antropometría , Caquexia/etiología , Caquexia/patología , Quimioradioterapia/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Músculo Esquelético/patología , Proyectos Piloto , Pronóstico , Estudios Prospectivos , Análisis de Supervivencia , Pérdida de Peso/fisiología
16.
AJR Am J Roentgenol ; 191(3): 646-52, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18716089

RESUMEN

OBJECTIVE: The purpose of this study was in vitro sonographic-pathologic correlation of findings in dissected axillary lymph nodes from breast cancer patients undergoing axillary lymph node dissection and classification of the sonographic appearance of the nodes on the basis of cortical morphologic features to facilitate early recognition of metastatic disease. MATERIALS AND METHODS: High-resolution sonography was used for in vitro examination of 171 lymph nodes from 19 axillae in 18 patients with unknown nodal status who underwent axillary lymph node dissection for early infiltrating breast cancer. The images were evaluated by two blinded observers, and discordant readings were referred to a third blinded observer. Each lymph node was classified as one of types 1-6 according to cortical morphologic features. Types 1-4 were considered benign, ranging from hyperechoic with no visible cortex to thickened generalized hypoechoic cortical lobulation. Type 5 (focal hypoechoic cortical lobulation) and type 6 (hypoechoic node with absent hilum) nodes were considered metastatic. The reference standard for metastatic disease was histopathologic evaluation of sectioned nodes by a single pathologist blinded to sonographic findings. Largest nodal diameter also was measured. RESULTS: Interobserver agreement was 77% for classification of nodal morphology (types 1-6) and 88% for characterization of a node as benign or malignant. Sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of cortical shape in prediction of metastatic involvement of axillary nodes were 77%, 80%, 36%, 96%, and 80%. Type 4 nodes had the most false-negative findings (four of 36). Node size ranged from 0.2 to 3.8 cm, and subcentimeter nodes of all types were detected. CONCLUSION: In breast cancer, axillary lymph nodes can be classified according to cortical morphologic features. Predominantly hyperechoic nodes (types 1-3) can be considered benign. Generalized cortical lobulation (type 4) is uncommonly a false-negative finding, but metastasis, if present, is invariably detected at sentinel node mapping. The presence of asymmetric focal hypoechoic cortical lobulation (type 5) or a completely hypoechoic node (type 6) should serve as a guideline for universal performance of fine-needle aspiration for preoperative staging of breast cancer. This classification, when verified with larger samples, may serve as a useful clinical guideline if proven with results of in vivo studies.


Asunto(s)
Axila/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Ganglios Linfáticos/diagnóstico por imagen , Ultrasonografía Mamaria/métodos , Adulto , Femenino , Humanos , Metástasis Linfática , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
AJR Am J Roentgenol ; 187(4): 1061-72, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16985158

RESUMEN

OBJECTIVE: The purpose of this study is to show how sonography can reveal pathology of the eye and to highlight its usefulness as a simple and cost-effective tool in investigating eye symptoms. CONCLUSION: The cystic nature of the eye, its superficial location, and high-frequency transducers make it possible to clearly show normal anatomy and pathology such as tumors, retinal detachment, vitreous hemorrhage, foreign bodies, and vascular malformations. Sonography is useful as a treatment follow-up technique because it has no adverse effects. Sonography is well tolerated by patients and relatively easy to perform for those familiar with real-time sonography.


Asunto(s)
Oftalmopatías/diagnóstico por imagen , Ojo/diagnóstico por imagen , Humanos , Ultrasonografía
18.
Ann Surg Oncol ; 10(9): 1025-30, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-14597440

RESUMEN

BACKGROUND: Ultrasonography and fine-needle aspiration (FNA) are used to evaluate the breast and regional nodes in breast cancer patients. We sought to identify factors influencing the sensitivity of ultrasonography for detection of nodal metastasis. METHODS: Patients with a clinically negative axilla who underwent axillary ultrasonography and sentinel lymph node biopsy were included. RESULTS: Of 208 patients, axillary ultrasonography was negative in 180 (86%) and suspicious or indeterminate in 28 (14%). FNA was performed in 22 patients whose findings were indeterminate or suspicious, and 3 were positive for malignancy. Final pathological examinations revealed positive nodes in 53 patients: 39 (22%) of 180 with negative ultrasonographic findings and 14 (50%) of 28 with indeterminate or suspicious ultrasonographic findings (P =.001). Excisional biopsy was more common for patients with indeterminate or suspicious findings on preoperative ultrasonography (P =.038). There were no significant differences in tumor size, histological features, size of nodal metastasis, or number of positive nodes between patients whose ultrasonography findings were negative and those whose findings were indeterminate or suspicious. CONCLUSIONS: Ultrasonographically suggested nodal metastasis is associated with the finding of nodal disease on final pathological examination. No significant clinicopathologic criteria were found to impact sensitivity of ultrasonography; however, excisional biopsy for diagnosis may be a confounding variable in subsequent axillary ultrasonography.


Asunto(s)
Neoplasias de la Mama/patología , Metástasis Linfática/diagnóstico por imagen , Metástasis Linfática/diagnóstico , Ultrasonografía/normas , Adulto , Anciano , Anciano de 80 o más Años , Axila , Biopsia con Aguja , Reacciones Falso Positivas , Femenino , Humanos , Metástasis Linfática/patología , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
19.
Radiology ; 227(2): 542-8, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12732703

RESUMEN

PURPOSE: To assess the value of ultrasonography (US) and US-guided fine-needle aspiration biopsy (FNAB) in the detection and diagnosis of recurrent cancer in breasts reconstructed with autogenous myocutaneous flaps after mastectomy for primary breast cancer and to describe the US appearances of recurrence in the reconstructed breast. MATERIALS AND METHODS: Between July 1994 and March 2001, US of the reconstructed breast was performed in 20 women with autogenous myocutaneous flap reconstruction. US findings were correlated with clinical and mammographic findings. US-guided FNAB of 25 (64%) of the 39 recurrent cancers depicted at US was performed. RESULTS: Twenty-one (54%) of the 39 recurrent cancers depicted at US were clinically occult. Mammography performed in 12 of the 20 patients with reconstructed breasts depicted 14 (56%) of the 25 recurrent cancers that were detected at US in these patients. US-guided FNAB helped to establish a definitive diagnosis of recurrent breast carcinoma in 24 (96%) of the 25 tumor specimens sampled. CONCLUSION: US and US-guided FNAB are valuable for the assessment of both palpable and clinically occult recurrent breast cancers in autogenous myocutaneous flap breast reconstructions.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Mamoplastia , Mastectomía , Recurrencia Local de Neoplasia/diagnóstico por imagen , Colgajos Quirúrgicos , Adulto , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Ultrasonografía
20.
Cancer ; 95(5): 982-8, 2002 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-12209680

RESUMEN

BACKGROUND: Ultrasound (US) is more sensitive than physical examination alone in determining axillary lymph node involvement during preliminary staging of breast carcinoma. Due to occasional overlap of sonographic features of benign and indeterminate lymph nodes, fine-needle aspiration (FNA) of sonographically indeterminate/suspicious lymph nodes can provide a more definitive diagnosis than US alone. This study was undertaken to determine the diagnostic accuracy of US-guided FNA of indeterminate/suspicious/metastatic-appearing axillary lymph nodes during the initial staging of breast carcinoma. METHODS: The cytology of 103 cases of US-guided FNA of nonpalpable indeterminate/suspicious/metastatic-appearing lymph nodes was compared with the final histopathologic status of the entire axilla after axillary dissection. The final axillary lymph node status was categorized as either negative when all lymph nodes were negative for metastasis or positive when there was evidence of metastasis in one or more lymph nodes. The sensitivity, specificity, diagnostic accuracy, and false-negative rate of US-guided FNA of nonpalpable axillary lymph nodes in the preliminary staging process were calculated. RESULTS: In 51 of 103 cases (49.5%), the US-guided FNA and histopathology were both positive for metastasis. In 24 of 103 cases (23.3%), both were negative. The apparent false-positive FNA in 16 (15.5%) cases was explained by the complete response of the metastatic lymph nodes to neoadjuvant chemotherapy in the interval between FNA and axillary dissection. In 12 cases (11.6%), US-guided FNA was negative, but metastasis was seen in histologic sections. All cases with three or more lymph nodes with metastatic disease and 93% of those with metastatic deposit measuring more than 0.5 mm were detected by US-guided FNA. The probability of detecting lymph nodes with smaller metastatic deposit measuring less than 0.5 cm was 44%. The overall sensitivity of US-guided FNA was 86.4%, the specificity was 100%, the diagnostic accuracy was 79.0%, the positive predictive value was 100%, and the negative predictive value was 67%. CONCLUSIONS: US-guided FNA of nonpalpable indeterminate and suspicious axillary lymph nodes is a simple, minimally invasive, and reliable technique for the initial determination of axillary lymph node status in breast carcinoma. The common causes of discrepancy between the initial and final axillary lymph node status include failure to visualize all lymph nodes during US examination, small-sized metastases, and preoperative neoadjuvant chemotherapy.


Asunto(s)
Neoplasias de la Mama/patología , Carcinoma/patología , Metástasis Linfática/diagnóstico , Ultrasonografía/métodos , Axila , Biopsia con Aguja , Citodiagnóstico/métodos , Reacciones Falso Negativas , Reacciones Falso Positivas , Femenino , Humanos , Escisión del Ganglio Linfático , Metástasis Linfática/patología , Control de Calidad , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...