Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
2.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-38749449

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Factores de Riesgo , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Resultado del Tratamiento , Anciano de 80 o más Años , Incidencia , Factores de Tiempo , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/fisiopatología , Europa (Continente) , Medición de Riesgo , Diseño de Prótesis , Oportunidad Relativa , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/diagnóstico , Estudios Retrospectivos
3.
J Cardiovasc Dev Dis ; 11(5)2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38786975

RESUMEN

Mitral stenosis (MS) poses significant challenges in diagnosis and management due to its varied etiologies, such as rheumatic mitral stenosis (RMS) and degenerative mitral stenosis (DMS). While rheumatic fever-induced RMS has declined in prevalence, DMS is rising with aging populations and comorbidities. Starting from a complex clinical case of DMS, the aim of this paper is to review the literature on mitral stenosis by analyzing the available tools and the differences in terms of diagnosis and treatment for rheumatic and degenerative stenosis. Emerging transcatheter techniques, such as transcatheter mitral valve replacement (TMVR) and lithotripsy-facilitated percutaneous mitral commissurotomy (PMC), represent promising alternatives for DMS patients deemed unfit for surgery. In particular, intravascular lithotripsy (IVL) has shown potential in facilitating percutaneous interventions by fracturing calcific deposits and enabling subsequent interventions. However, larger prospective studies are warranted to validate these findings and establish IVL's role in DMS management. To further enhance this technique, research could focus on investigating the long-term outcomes and durability of mitral lithotripsy, as well as exploring its potential in combination with PMC or TMVR.

4.
G Ital Cardiol (Rome) ; 25(5): 295-299, 2024 May.
Artículo en Italiano | MEDLINE | ID: mdl-38639118

RESUMEN

Patent foramen ovale (PFO) is a remnant of normal fetal anatomy which may persist into adulthood, mostly asymptomatic. In some adults, PFO may result in a potential for shunting venous thromboembolism to the arterial circulation; less frequently it can cause interatrial, right-to-left shunting of deoxygenated blood. The pathogenesis of several medical conditions is related to the presence of PFO. Some randomized clinical trials have shown evidence of benefit for device closure as compared with medical therapy in patients with cryptogenic stroke. The literature reported several cases of carbon dioxide embolism during general laparoscopic surgery and sometimes stroke after laparoscopic or neurosurgery but there are neither prospective studies addressing these issues, nor randomized clinical trials assessing the effectiveness of pharmacotherapy or interventional procedures at decreasing risk. The European position paper suggests routine monitoring in non-cardiac surgery of patients with a PFO and no actual indications for closure. This article aims to further stratify the risk of periprocedural stroke and paradoxical embolism in this category of patients.


Asunto(s)
Embolia Paradójica , Foramen Oval Permeable , Accidente Cerebrovascular , Adulto , Humanos , Embolia Paradójica/etiología , Embolia Paradójica/prevención & control , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/cirugía , Estudios Prospectivos , Prevención Secundaria/métodos , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37957842

RESUMEN

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Dilatación , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
6.
EuroIntervention ; 20(5): e289-e300, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-37982178

RESUMEN

BACKGROUND: Microvascular resistance reserve (MRR) is a validated measure of coronary microvascular function independent of epicardial resistances. AIMS: We sought to assess whether MRR is associated with adverse cardiac remodelling, a low-flow phenotype and extravalvular cardiac damage (EVCD) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS: Invasive thermodilution-based assessment of the coronary microvascular function of the left anterior descending artery was performed in a prospective, multicentre cohort of patients undergoing TAVI. Coronary microvascular dysfunction (CMD) was defined as the lowest MRR tertile of the study cohort. Haemodynamic measurements were performed at baseline and then repeated immediately after TAVI. EVCD and markers of a low-flow phenotype were assessed with echocardiography. RESULTS: A total of 134 patients were included in this study. Patients with low MRR were more frequently females, had a lower estimated glomerular filtration rate and a higher rate of atrial fibrillation. MRR was significantly lower in patients with advanced EVCD (median 1.80 [1.26-3.30] vs 2.50 [1.87-3.41]; p=0.038) and in low-flow, low-gradient AS (LF LG-AS) (median 1.85 [1.20-3.04] vs 2.50 [1.87-3.40]; p=0.008). Overall, coronary microvascular function tended to improve after TAVI and, in particular, MRR increased significantly after TAVI in the subgroup with low MRR at baseline. However, MRR was significantly impaired in 38 (28.4%) patients immediately after TAVI. Advanced EVCD (adjusted odds ratio 3.08 [1.22-7.76]; p=0.017) and a low-flow phenotype (adjusted odds ratio 3.36 [1.08-10.47]; p=0.036) were significant predictors of CMD. CONCLUSIONS: In this observational, hypothesis-generating study, CMD was associated with extravalvular cardiac damage and a low-flow phenotype in patients with severe AS undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Isquemia Miocárdica , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
Cardiovasc Revasc Med ; 62: 85-94, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38160130

RESUMEN

Valve-in-valve transcatheter aortic valve implantation (ViV TAVI) is rapidly arising as a safe and effective alternative to redo-surgery in the treatment of bioprostheses deterioration. While scientific community is currently focusing its attention on the most common limitations related to this procedure, such as the risk of coronary obstruction and patient-prosthesis mismatch, data regarding the first step of a ViV TAVI, the crossing of a degenerated bioprosthesis, are still lacking. The aim of this review is to analyze the available information about bioprosthesis crossing, to show the inherent challenges encountered by interventional cardiologists during valve crossing and to describe the current strategies to perform a correct crossing.


Asunto(s)
Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
8.
JACC Case Rep ; 22: 101978, 2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37790775

RESUMEN

Ischemia with no obstructive coronary artery disease (INOCA) is not an uncommon diagnosis in patients presenting with chest pain who undergo clinically indicated coronary angiography. However, the symptoms reported by patients with INOCA may be heterogeneous, leading to misdiagnosis and undertreatment. Herein we report 3 clinical cases of INOCA misdiagnosis and describe how the cases were reinvestigated following the appropriate diagnostic pathway. (Level of Difficulty: Advanced.).

10.
Int J Cardiol ; 389: 131188, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37453454

RESUMEN

BACKGROUND: LAAO is an emerging option for thromboembolic event prevention in patients with NVAF. We previously reported data on comparison between LAAO and DOAC at two-year follow-up in NVAF patients at HBR (HAS-BLED ≥3). AIMS: Limited data are available on long term follow-up. We aimed to evaluate the efficacy and safety of DOACs versus LAAO indication after 5 years. METHODS: We enrolled 193 HBR treated with LAAO and 189 HBR patients with DOACs. At baseline, LAAO group had higher HAS-BLED (4.2 vs 3.3, p < 0.001) and lower CHADS-VASc (4.3 vs. 4.7, p = 0.005). After 1:1 PSM, 192 patients were included (LAAO n = 96; DOACs n = 96). RESULTS: At 5-year follow-up the rate of the combined safety and effectiveness endpoint (ISTH major bleeding and thromboembolic events) was significantly higher in LAAO group (p = 0.042), driven by a higher number of thromboembolic events (p = 0.047). The rate of ISTH-major bleeding events was similar (p = 0.221). After PSM no significant difference in the primary effectiveness (LAAO 13.3% vs DOACs 9.5%, p = 0.357) and safety endpoint (LAAO 7.5% vs DOACs 7.5%; p = 0.918) were evident. Overall bleeding rate was significantly higher in DOACs group (25.0% vs 13.7%, p = 0.048), while a non-significant higher number of TIA was reported in LAAO group (5.4% vs 1.1%, p = 0.098). All-cause and cardiovascular mortality were higher in LAAO group at both unmatched and matched analysis. CONCLUSION: We confirmed safety and effectiveness of both DOAC and LAAO in NVAF patients at HBR, with no significant differences in thromboembolic events or major bleeding were at 5-year follow-up. The observed increased mortality after LAAO warrants further investigations in RCTs.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Tromboembolia , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Apéndice Atrial/cirugía , Hemorragia/inducido químicamente , Anticoagulantes/efectos adversos , Tromboembolia/epidemiología , Tromboembolia/etiología , Tromboembolia/prevención & control , Resultado del Tratamiento
15.
Psicol. teor. prát ; 25(1): 14535, 19.12.2022.
Artículo en Inglés, Portugués | LILACS | ID: biblio-1436509

RESUMEN

Este estudo teve como objetivo explorar a percepção de alunos de graduação em relação à sua participação em uma intervenção baseada na terapia de aceitação e compromisso (acceptance and commitment therapy[ACT]), para redução da inflexibilidade psicológica (IP) e do estresse em estudantes universitários. Parti­ciparam da pesquisa 21 alunos, de diferentes cursos de graduação, com idade média de 23,4 ± 5,61, sendo 71,4% do sexo feminino e 28,6% do sexo masculino. Os dados coletados nas entrevistas foram submetidos à análise de conteúdo e organizados em quatro categorias: experiência no programa, utilidade, viabilidade e sugestões e processos da ACT. Os resultados possibilitaram identificar que o programa foi uma experiên-cia positiva para os participantes. Além disso, constatou-se que a intervenção foi útil e viável, e possibili-tou que os estudantes desenvolvessem as habilidades necessárias para lidar melhor com as adversidades do dia a dia, sem que precisassem se afastar dos seus valores pessoais.


This study aims to explore undergraduate students' perception of their participation in an intervention, based on acceptance and commitment therapy (ACT), to reduce psychological inflexibility (PI) and stress in undergraduate students. Twenty­one students from different undergraduate programs participated in the research, with an average age of 23.4 ± 5.61, of whom 71.4% were female and 28.6% were male. The data collected in the interviews were submitted to content analysis and organized into four categories: experience in the program, utility, feasibility, and ACT suggestions and processes. The results made it possible to identify that the program was a positive experience for the participants, the intervention was useful and feasible and enabled students to develop the requirements to better deal with the adversities of daily life without departing from their personal values.


Este estudio tiene como objetivo explorar la percepción de los estudiantes de pregrado sobre su participa-ción en una intervención, basada en la terapia de aceptación y compromiso (acceptance and commitment therapy [ACT]), para reducir la inflexibilidad psicológica (IP) y el estrés en los estudiantes de pregrado. En la investigación participaron 21 estudiantes de diferentes carreras, con una edad promedio de 23,4 ± 5,61, de los cuales el 71,4% eran mujeres y el 28,6% hombres. Los datos recolectados en las entrevistas fueron sometidos a análisis de contenido y organizados en cuatro categorías: experiencia en el programa, utilidad, factibilidad y sugerencias y procesos de ACT. Los resultados permitieron identificar que el programa fue una experiencia positiva para los participantes, la intervención fue útil y factible y permitió a los estudian-tes desarrollar los requisitos necesarios para enfrentar mejor las adversidades de la vida diaria, sin apar-tarse de sus valores personales.


Asunto(s)
Humanos , Masculino , Femenino , Estrés Psicológico , Terapia de Aceptación y Compromiso , Psicología , Estudiantes , Salud Mental , Investigación Cualitativa , Actividades Científicas y Tecnológicas
16.
J Am Heart Assoc ; 11(19): e025944, 2022 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-36172929

RESUMEN

The impact of sex on pathophysiological processes, clinical presentation, treatment options, as well as outcomes of degenerative aortic stenosis remain poorly understood. Female patients are well represented in transfemoral aortic valve implantation (TAVI) trials and appear to derive favorable outcomes with TAVI. However, higher incidences of major bleeding, vascular complications, and stroke have been reported in women following TAVI. The anatomical characteristics and pathophysiological features of aortic stenosis in women might guide a tailored planning of the percutaneous approach. We highlight whether a sex-based TAVI management strategy might impact on clinical outcomes. This review aimed to evaluate the impact of sex from diagnosis to treatment of degenerative aortic stenosis, discussing the latest evidence on epidemiology, pathophysiology, clinical presentation, therapeutic options, and outcomes. Furthermore, we focused on technical sex-oriented considerations in TAVI including the preprocedural screening, device selection, implantation strategy, and postprocedural management.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
Cardiovasc Revasc Med ; 43: 1-6, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35690553

RESUMEN

BACKGROUND: Transcatheter aortic valve implant (TAVI) is gaining momentum in the treatment of severe, symptomatic aortic valve stenosis, and its indication is expanding to lower surgical risk individuals, who are generally younger and have a long life expectancy. Therefore, transcatheter bioprostheses durability appears of critical importance. Aim of the present study is to evaluate mid-term outcomes of TAVI in a high-volume single center cohort. METHODS: We analyzed all consecutive patients (n = 408) who underwent transfemoral TAVI at a single, high-volume center, between 2007 and 2014. Study objectives were all-cause death and bioprosthetic valve failure (BVF) at long term follow-up. Structural valve deterioration (SVD), BVF and valve-related death were defined according to current international standards. Follow-up was performed by in person visit and transthoracic echocardiography, which was obtained only in a minority of patients, or phone call as per patient preference. RESULTS: At a median follow-up of 1821 days, overall mortality was 64.5%, with cardiovascular disease accounting for roughly half of total deaths. Valve-related deaths occurred in 10 patients. Seventeen patients were diagnosed with BVF, and 15 required repeat intervention. Moderate and severe SVD were observed in 10 and 7 patients, respectively. In the subgroup of patients with echocardiographic mid-term follow-up (n = 76), no significant increase of transprosthetic gradients nor increase of significant regurgitation was detected. CONCLUSION: In the present unselected, all-comers cohort, TAVI bioprostheses appeared to have excellent durability at long-term follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
Catheter Cardiovasc Interv ; 100(2): 190-198, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35686523

RESUMEN

AIM: The impact of Grade III coronary perforations (G3-CP) in the setting of CTO-PCI is not well assessed. METHODS AND RESULTS: We reviewed 7773 CTO-PCI and 98,819 non CTO-PCI performed in 10 European centers: G3 perforation occurred in 87 patients (1.1%) during CTO PCI and 224 patients (0.22%) during non CTO-PCI (p < 0.001). G3-CP involved the CTO segment in 68% of patients and the retrograde channels in 14% of cases. In the CTO PCI group, wire induced G3-CP (50.5% vs. 32.5%, p = 0.02) occurred predominantly when dedicated CTO tapered and highly penetrative wires were used. Intra-procedural and in-hospital death rates were 4.6% vs. 5.8% and 3.6% vs. 7.5% respectively for CTO PCI and non-CTO PCI groups (p = NS). At a median follow up of 24 months, the overall mortality and MAE were respectively 7.8% and MAE 19% without difference among groups. CONCLUSIONS: We showed similar in-hospital and long-term outcomes when G3 perforations occurred during CTO PCI and non CTO-PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Oclusión Coronaria , Lesiones Cardíacas , Intervención Coronaria Percutánea , Lesiones del Sistema Vascular , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Mortalidad Hospitalaria , Humanos , Sistema de Registros , Factores de Riesgo , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA