Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 19 de 19
1.
J Arthroplasty ; 39(4): 991-996, 2024 Apr.
Article En | MEDLINE | ID: mdl-38661490

BACKGROUND: We aimed to compare the clinical outcomes of different head sizes (28-, 32-, and 36- millimeter) in primary total hip arthroplasty (THA) at mean 6 years follow-up (range, 1 to 17.5 years). METHODS: This was a retrospective consecutive study of primary THA at our institution (2003 to 2019). Demographic and surgical data were collected. The primary outcome measures were all-cause revision, revision for dislocation, and all-cause revision excluding dislocation. Continuous descriptive statistics used means, median values, ranges, and 95% confidence intervals, where appropriate. Kaplan-Meier survival curves were used to estimate time to revision. Cox proportional hazard regression analyses were used to compare revision rates between the femoral head size groups. Adjustments were made for age at surgery, sex, primary diagnosis, American Society of Anesthesiologists score, articulation type, and fixation methods. There were 10,104 primary THAs included; median age was 69 years (range, 13 to 101) with 61.5% women. A posterior approach was performed in 71.6%. There were 3,295 hips with 28-mm heads (32.6%), 4,858 (48.1%) with 32-mm heads, and 1,951 (19.3%) with 36-mm heads. RESULTS: Overall rate of revision was 1.7% with the lowest rate recorded for the 36-mm group (2.7 versus 1.3 versus 1.1%). Cox regression analyses showed a decreased risk of all-cause revision for 32 and 36-mm head sizes as compared to 28-mm; this was statistically significant for the 32-mm group (P = .01). Risk of revision for dislocation was significantly reduced in both 32-mm (P = .03) and 36-mm (P = .03) head sizes. Analysis of all cause revision excluding dislocation showed no significant differences between head sizes. CONCLUSIONS: We found a significantly reduced risk of revision for all causes, but particularly revision for dislocation with larger head sizes. Concerns regarding increased risk of early revision for aseptic loosening, polyethylene wear, or taper corrosion with larger heads appear to be unfounded in this cohort of 10,104 patients with up to 17 years follow-up.


Arthroplasty, Replacement, Hip , Femur Head , Hip Prosthesis , Prosthesis Failure , Reoperation , Humans , Arthroplasty, Replacement, Hip/instrumentation , Female , Male , Reoperation/statistics & numerical data , Middle Aged , Aged , Retrospective Studies , Adult , Femur Head/surgery , Aged, 80 and over , Adolescent , Prosthesis Design , Young Adult , Follow-Up Studies , Risk Factors
2.
Bone Joint J ; 105-B(6): 641-648, 2023 Jun 01.
Article En | MEDLINE | ID: mdl-37257848

Aims: Revision total knee arthroplasty (rTKA) and revision total hip arthroplasty (rTHA) are complex procedures with higher rates of re-revision, complications, and mortality compared to primary TKA and THA. We report the effects of the establishment of a revision arthroplasty network (the East Midlands Specialist Orthopaedic Network; EMSON) on outcomes of rTKA and rTHA. Methods: The revision arthroplasty network was established in January 2015 and covered five hospitals in the Nottinghamshire and Lincolnshire areas of the East Midlands of England. This comprises a collaborative weekly multidisciplinary meeting where upcoming rTKA and rTHA procedures are discussed, and a plan agreed. Using the Hospital Episode Statistics database, revision procedures carried out between April 2011 and March 2018 (allowing two-year follow-up) from the five network hospitals were compared to all other hospitals in England. Age, sex, and mean Hospital Frailty Risk scores were used as covariates. The primary outcome was re-revision surgery within one year of the index revision. Secondary outcomes were re-revision surgery within two years, any complication within one and two years, and median length of hospital stay. Results: A total of 57,621 rTHA and 33,828 rTKA procedures were performed across England, of which 1,485 (2.6%) and 1,028 (3.0%), respectively, were conducted within the network. Re-revision rates within one year for rTHA were 7.3% and 6.0%, and for rTKA were 11.6% and 7.4% pre- and postintervention, respectively, within the network. This compares to a pre-to-post change from 7.4% to 6.8% for rTHA and from 11.7% to 9.7% for rTKA for the rest of England. In comparative interrupted time-series analysis for rTKA there was a significant immediate improvement in one-year re-revision rates for the revision network compared to the rest of England (p = 0.024), but no significant change for rTHA (p = 0.504). For the secondary outcomes studied, there was a significant improvement in trend for one- and two-year complication rates for rTHA for the revision network compared to the rest of England. Conclusion: Re-revision rates for rTKA and complication rates for rTHA improved significantly at one and two years with the introduction of a revision arthroplasty network, when compared to the rest of England. Most of the outcomes studied improved to a greater extent in the network hospitals compared to the rest of England when comparing the pre- and postintervention periods.


Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Risk Factors , Reoperation , Databases, Factual , Retrospective Studies
3.
Bone Jt Open ; 4(5): 357-362, 2023 May 17.
Article En | MEDLINE | ID: mdl-37195092

Aims: It is common practice for patients to have postoperative blood tests after total joint replacement (TJR). However, there have been significant improvements in perioperative care with arthroplasty surgery, and a drive to reduce the length of stay (LOS) and move towards day-case TJR. We should reconsider whether this intervention is necessary for all patients. Methods: This retrospective study included all patients who underwent a primary unilateral TJR at a single tertiary arthroplasty centre during a one-year period. Electronic medical records of 1,402 patients were reviewed for patient demographics, LOS, and American Society of Anesthesiologists (ASA) grade. Blood tests were examined to investigate the incidence of postoperative anaemia, electrolyte abnormalities, and incidence of acute kidney injury (AKI). Results: For total knee arthroplasties, preoperative (R = -0.22) and postoperative haemoglobin (R = 0.2) levels were both negatively correlated with LOS (p < 0.001). For all patients who had undergone a TJR, 19 patients (0.014%) required a blood transfusion postoperatively due to symptomatic anaemia. Risk factors identified were age, preoperative anaemia, and long-term aspirin use. Significant abnormal sodium levels were found in123 patients (8.7%). However, only 36 patients (2.6%) required intervening treatment. Risk factors identified were age, preoperative abnormal sodium level, and long-term use of non-steroidal anti-inflammatory drugs, angiotensin receptor blockers, and corticosteroids. Similarly, abnormal potassium levels were evident in 53 patients (3.8%), and only 18 patients (1.3%) required intervening treatment. Risk factors identified were preoperative abnormal potassium level, and long-term use of angiotensin-converting enzyme inhibitors and diuretics. The incidence of AKI was 4.4% (61 patients). Risk factors identified were age, increased ASA grade, preoperative abnormal sodium, and creatinine level. Conclusion: Routine blood tests after primary TJR is unnecessary for most patients. Blood tests should only be performed on those with identifiable risk factors such as preoperative anaemia and electrolyte abnormalities, haematological conditions, long-term aspirin use, and electrolyte-altering medications.

4.
Arthroplast Today ; 19: 101086, 2023 Feb.
Article En | MEDLINE | ID: mdl-36688095

Background: Ceramic coatings in total knee arthroplasty have been introduced with the aim of reducing wear and consequently improving implant survivorship. We studied both cobalt-chrome-molybdenum (CoCrMo) and ceramic-coated components of the same implant design from a single center to identify if the ceramic coating conferred any benefit. Methods: We identified 1641 Columbus total knee arthroplasties (Aesculap AG, Tüttlingen, Germany) from a prospectively collected arthroplasty database. Of the 1641, 983 were traditional CoCrMo, and 659 had the Columbus AS ceramic coating. Patients were followed up until death or revision of any component of the implant. Results: There was no significant difference in implant survivorship using any component revision as the endpoint between the CoCrMo femur and the ceramic-coated femur at a mean of 9.2 years in follow-up for the CoCrMo group and 5 years for the ceramic-coated group (37 vs 14; P = .76). There was no reduction in the proportion of components revised for aseptic loosening or infection in the ceramic-coated cohort. Conclusions: At midterm follow-up, there was no benefit in terms of implant survivorship in using a ceramic coating.

5.
Bone Joint J ; 104-B(2): 206-211, 2022 Feb.
Article En | MEDLINE | ID: mdl-35094580

AIMS: Total hip arthroplasty (THA) is a very successful and cost-effective operation, yet debate continues about the optimum fixation philosophy in different age groups. The concept of the 'cementless paradox' and the UK 'Getting it Right First Time' initiative encourage increased use of cemented fixation due to purported lower revision rates, especially in elderly patients, and decreased cost. METHODS: In a high-volume, tertiary referral centre, we identified 10,112 THAs from a prospectively collected database, including 1,699 cemented THAs, 5,782 hybrid THAs, and 2,631 cementless THAs. The endpoint was revision for any reason. Secondary analysis included examination of implant survivorship in patients aged over 70 years, over 75 years, and over 80 years at primary THA. RESULTS: Cemented fixation had the lowest implant survival in all age groups, with a total ten-year survivorship of 97.0% (95% confidence interval (CI) 95.8 to 97.8) in the cemented group, 97.6% (95% CI 96.9 to 98.1) in the hybrid group, and 97.9% (95% CI 96.9 to 98.6) in the cementless group. This was not statistically significant (p = 0.092). There was no age group where cemented fixation outperformed hybrid or cementless fixation. CONCLUSION: While all fixation techniques performed well at long-term follow-up, cemented fixation was associated with the lowest implant survival in all age groups, including in more elderly patients. We recommend that surgeons should carefully monitor their own outcomes and use fixation techniques that they are familiar with, and deliver the best outcomes in their own hands. Cite this article: Bone Joint J 2022;104-B(2):206-211.


Arthroplasty, Replacement, Hip/methods , Bone Cements , Hip Prosthesis , Prosthesis Failure/etiology , Reoperation/statistics & numerical data , Age Factors , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/instrumentation , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Outcome Assessment, Health Care , Retrospective Studies
6.
Sci Rep ; 11(1): 10157, 2021 05 12.
Article En | MEDLINE | ID: mdl-33980936

Incidence of hip fractures has remained unchanged during the pandemic with overlapping vulnerabilities observed in patients with hip fractures and those infected with COVID-19. We aimed to investigate the independent impact of COVID-19 infection on the mortality of these patients. Healthcare databases were systematically searched over 2-weeks from 1st-14th November 2020 to identify eligible studies assessing the impact of COVID-19 on hip fracture patients. Meta-analysis of proportion was performed to obtain pooled values of prevalence, incidence and case fatality rate of hip fracture patients with COVID-19 infection. 30-day mortality, excess mortality and all-cause mortality were analysed using a mixed-effects model. 22 studies reporting 4015 patients were identified out of which 2651 (66%) were assessed during the pandemic. An excess mortality of 10% was seen for hip fractures treated during the pandemic (OR 2.00, p = 0.007), in comparison to the pre-pandemic controls (5%). Estimated mortality of COVID-19 positive hip fracture patients was four-fold (RR 4.59, p < 0.0001) and 30-day mortality was 38.0% (HR 4.73, p < 0.0001). The case fatality rate for COVID-19 positive patients was 34.74%. Between-study heterogeneity for the pooled analysis was minimal (I2 = 0.00) whereas, random effects metaregression identified subgroup heterogeneity for male gender (p < 0.001), diabetes (p = 0.002), dementia (p = 0.001) and extracapsular fractures (p = 0.01) increased risk of mortality in COVID-19 positive patients.


COVID-19/complications , Hip Fractures/complications , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/mortality , Hip Fractures/epidemiology , Hip Fractures/mortality , Hospital Mortality , Humans , Pandemics , Risk Assessment , Risk Factors , SARS-CoV-2/isolation & purification
7.
J Clin Orthop Trauma ; 11(Suppl 4): S500-S505, 2020 Jul.
Article En | MEDLINE | ID: mdl-32774018

Low Intensity Pulsed Ultrasound Therapy (LIPUS) is a non-invasive treatment and aims to reduce fracture healing time and avoid non-union by delivering micro-mechanical stress to the bone to stimulate bone healing. In 2018, the National Institute for Health and Clinical Excellence (NICE) recommended that the evidence for LIPUS to promote healing of delayed-union and non-union fractures raised no major safety concerns, but the current evidence on efficacy is inadequate in quality. Little is known about the potential benefits of LIPUS for fracture healing in diabetic patients. In this article, we review the current evidence of LIPUS therapy both in animal and human studies and its possible application on fractures in diabetics.

8.
J Bone Joint Surg Am ; 99(21): 1827-1835, 2017 Nov 01.
Article En | MEDLINE | ID: mdl-29088037

BACKGROUND: High failure rates of metal-on-metal (MoM) hip implants prompted regulatory authorities to issue worldwide safety alerts. Circulating cobalt from these implants causes rare but fatal autopsy-diagnosed cardiotoxicity. There is concern that milder cardiotoxicity may be common and underrecognized. Although blood metal ion levels are easily measured and can be used to track local toxicity, there are no noninvasive tests for organ deposition. We sought to detect correlation between blood metal ions and a comprehensive panel of established markers of early cardiotoxicity. METHODS: Ninety patients were recruited into this prospective single-center blinded study. Patients were divided into 3 age and sex-matched groups according to implant type and whole-blood metal ion levels. Group-A patients had a ceramic-on-ceramic [CoC] bearing; Group B, an MoM bearing and low blood metal ion levels; and Group C, an MoM bearing and high blood metal-ion levels. All patients underwent detailed cardiovascular phenotyping using cardiac magnetic resonance imaging (CMR) with T2*, T1, and extracellular volume mapping; echocardiography; and cardiac blood biomarker sampling. T2* is a novel CMR biomarker of tissue metal loading. RESULTS: Blood cobalt levels differed significantly among groups A, B, and C (mean and standard deviation [SD], 0.17 ± 0.08, 2.47 ± 1.81, and 30.0 ± 29.1 ppb, respectively) and between group A and groups B and C combined. No significant between-group differences were found in the left atrial or ventricle size, ejection fraction (on CMR or echocardiography), T1 or T2* values, extracellular volume, B-type natriuretic peptide level, or troponin level, and all values were within normal ranges. There was no relationship between cobalt levels and ejection fraction (R = 0.022, 95% confidence interval [CI] = -0.185 to 0.229) or T2* values (R = 0.108, 95% CI = -0.105 to 0.312). CONCLUSIONS: Using the best available technologies, we did not find that high (but not extreme) blood cobalt and chromium levels had any significant cardiotoxic effect on patients with an MoM hip implant. There were negligible-to-weak correlations between elevated blood metal ion levels and ejection fraction even at the extremes of the 95% CI, which excludes any clinically important association. LEVEL OF EVIDENCE: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.


Arthroplasty, Replacement, Hip/adverse effects , Cardiac Imaging Techniques/methods , Cardiotoxicity/diagnostic imaging , Cardiotoxicity/etiology , Magnetic Resonance Imaging/methods , Metal-on-Metal Joint Prostheses/adverse effects , Aged , Aged, 80 and over , Cobalt/adverse effects , Cobalt/blood , Cross-Sectional Studies , Female , Hip Prosthesis/adverse effects , Humans , Iron/analysis , Male , Middle Aged , Multimodal Imaging , Prospective Studies , Risk Factors
9.
J Arthroplasty ; 32(1): 286-290, 2017 01.
Article En | MEDLINE | ID: mdl-27471212

BACKGROUND: Trunnionosis of the tapered head-stem junction of total hip arthroplasties, either through corrosion or mechanical wear, has been implicated in early implant failure. Retrieval analysis of large numbers of failed implants can help us better understand the factors that influence damage at this interface. METHODS: In this study, we examined 120 retrieved total hip arthroplasties of one bearing design, the 36-mm diameter metal-on-metal, DePuy Pinnacle, that had been paired with 3 different stems. We measured material loss of the bearing and head-trunnion taper surfaces and collected clinical and component data for each case. We then used multiple linear regression analysis to determine which factors influenced the rate of taper material loss. RESULTS: We found 4 significant variables: (1) longer time to revision (P = .004), (2) the use of a 12/14 taper for the head-trunnion junction (P < .001), (3) decreased bearing surface wear (P = .003), and (4) vertical femoral offset (P = .05). These together explained 29% of the variability in taper material loss. CONCLUSION: Our most important finding is the effect of trunnion design. Of the 3 types studied, we found that S-ROM design was the most successful at minimizing trunnionosis.


Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Metal-on-Metal Joint Prostheses/adverse effects , Prosthesis Failure , Adult , Aged , Corrosion , Device Removal , Female , Femur/surgery , Humans , Male , Metals/adverse effects , Middle Aged , Prosthesis Design
10.
World J Orthop ; 7(5): 272-9, 2016 May 18.
Article En | MEDLINE | ID: mdl-27190754

The debate on how best to manage patients with metal-on-metal (MOM) hip implants continues. With over 1 million patients affected worldwide, the impact is far reaching. The majority of the aggressive failures of MOM hip implants have been dealt with by revision hip surgery, leaving patients with a much more indolent pattern of failure of devices that have been in situ for more than 10 years. The longer-term outcome for such patients remains unknown, and much debate exists on how best to manage these patients. Regulatory guidance is available but remains open to interpretation due to the lack of current evidence and long-term studies. Metal ion thresholds for concern have been suggested at 7 ppb for hip resurfacing arthroplasty and below this level for large diameter total hip arthroplasties. Soft tissue changes including pseudotumours and muscle atrophy have been shown to progress, but this is not consistent. New advanced imaging techniques are helping to diagnose complications with metal hips and the reasons for failure, however these are not widely available. This has led to some centres to tackle difficult cases through multidisciplinary collaboration, for both surgical management decisions and also follow-up decisions. We summarise current evidence and consider who is at risk, when revision should be undertaken and how patients should be managed.

11.
J Cardiovasc Magn Reson ; 18(1): 29, 2016 05 06.
Article En | MEDLINE | ID: mdl-27153940

BACKGROUND: Failed hip prostheses can cause elevated circulating cobalt and chromium levels, with rare reports of fatal systemic organ deposition, including cobalt cardiomyopathy. Although blood cobalt and chromium levels are easily measured, organ deposition is difficult to detect without invasive biopsy. The T2* magnetic resonance (MR) method is used to quantify tissue iron deposition, and plays an important role in the management of iron-loading conditions. Cobalt and chromium, like iron, also affect magnetism and are proposed MR contrast agents. CASE PRESENTATION: We describe a case of a 44-year-old male with a failed hip implant and very elevated blood cobalt and chromium levels. Despite normal cardiac MR findings, liver T2* and R2 values were abnormal, triggering tissue biopsy. Liver tissue analysis, including X-ray fluorescence, demonstrated heavy elemental cobalt and chromium deposition in macrophages, and no detectable iron. CONCLUSIONS: Our case demonstrates T2* and R2 quantification of liver metal deposition in a patient with a failed hip implant. Further work is needed to investigate the role of T2* and R2 MR in the detection of metal deposition from metal on metal hip prostheses.


Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Liver/diagnostic imaging , Magnetic Resonance Imaging , Metal-on-Metal Joint Prostheses , Prosthesis Failure , Adult , Arthroplasty, Replacement, Hip/adverse effects , Biopsy , Chromium Alloys/metabolism , Humans , Liver/metabolism , Male , Predictive Value of Tests , Prosthesis Design , Spectrometry, X-Ray Emission , Tissue Distribution
12.
Int Orthop ; 40(11): 2247-2254, 2016 Nov.
Article En | MEDLINE | ID: mdl-26810903

PURPOSE: The clinical significance of corrosion of cemented femoral stems is unclear. The purpose of this retrieval study was to: (1) report on corrosion at the stem-cement interface and (2) correlate these findings with clinical data. METHODS: We analysed cemented stems (n = 36) composed of cobalt-chromium (CoCr) and stainless steel (SS) in a series of revised metal-on-metal hips. We performed detailed inspection of each stem to assess the severity of corrosion at the stem-cement interface using a scale of 1 (low) to 5 (severe). We assessed the severity of corrosion at each stem trunnion and measured wear rates at the head taper and bearing surfaces. We used non-parametric tests to determine the significance of differences between the CoCr and SS stems in relation to: (1) pre-revision whole blood Co and Cr metal ion levels, (2) trunnion corrosion, (3) bearing surface wear and (4) taper material loss. RESULTS: The corrosion scores of CoCr stems were significantly greater than SS stems (p < 0.01). Virtually all stem trunnions in both alloy groups had minimal evidence of corrosion. The median pre-revision Co levels of implants with CoCr stems were significantly greater than the SS stems (p < 0.01). There was no significant difference in relation to pre-revision Cr levels (p = 0.521). There was no significant difference between the two stem types in relation to bearing wear (p = 0.926) or taper wear (p = 0.148). CONCLUSIONS: Severe corrosion of cemented femoral stems is a common finding at our retrieval centre; surgeons should consider corrosion of CoCr stems as a potential source of metal ions when revising a hip.


Arthroplasty, Replacement, Hip/adverse effects , Bone Cements/adverse effects , Femur/surgery , Metal-on-Metal Joint Prostheses/adverse effects , Adult , Aged , Aged, 80 and over , Alloys , Arthroplasty, Replacement, Hip/methods , Chromium , Cobalt , Corrosion , Female , Hip Joint/surgery , Hip Prosthesis , Humans , Male , Metals , Middle Aged , Prosthesis Design , Prosthesis Failure , Retrospective Studies
13.
J Arthroplasty ; 31(5): 1123-7, 2016 05.
Article En | MEDLINE | ID: mdl-26796774

BACKGROUND: The size of the clinical impact of corrosion of the taper junction of metal-on-metal total hip arthroplasties (MOM-THAs) is unclear. Examination of a large number of retrieved MOM resurfacings and total hip arthroplasties can help us understand the role of taper corrosion in metal ion release. METHODS: We graded the severity of corrosion at the taper junction of 395 MOM-THAs and compared the prerevision whole blood metal ion levels of these hips with 529 failed MOM hip resurfacings. RESULTS: Virtually all MOM-THA hips (n = 388) had evidence of corrosion of the head-stem taper junction and graded as severe in 31% (n = 124). The median cobalt/chromium (Co/Cr) ratio was 1.58 (0.01-13.82) and 1.08 (0-4.86) for MOM-THA and MOM hip resurfacing, respectively; this difference was significant (P < .001). THA hips with severely corroded tapers had the highest median Co/Cr ratio of 1.86 (0.01-10). CONCLUSIONS: This study demonstrates the high prevalence of severe taper corrosion, which may be related to an elevated Co/Cr ratio before revision.


Arthroplasty, Replacement, Hip/adverse effects , Chromium/blood , Cobalt/blood , Hip Joint/surgery , Hip Prosthesis/adverse effects , Joint Diseases/surgery , Metal-on-Metal Joint Prostheses/adverse effects , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/instrumentation , Corrosion , Female , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Retrospective Studies , Young Adult
14.
Hip Int ; 25(3): 227-31, 2015.
Article En | MEDLINE | ID: mdl-25952914

Detailed visual inspection of metal hips is the first step in retrieval analysis. In this study a systematic visual inspection protocol was developed to quantify bearing surface changes and their associations with material loss was investigated. Simple and multiple linear regression models found that moderate surface scratching, discolouration, haziness and the size of visible wear scars were all significantly associated with material loss (R2 = 5%-73%, p<0.05). Visual inspection is not a substitute for measurement of material loss but an understanding of bearing surface changes may offer unique clues as to the mechanisms of failure of retrieved hips.


Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Metal-on-Metal Joint Prostheses/standards , Adult , Aged , Aged, 80 and over , Equipment Failure Analysis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Surface Properties
15.
J Bone Joint Surg Am ; 97(4): e20, 2015 Feb 18.
Article En | MEDLINE | ID: mdl-25695991

BACKGROUND: Over one million patients worldwide are estimated to have a metal-on-metal hip arthroplasty. To improve the management of these patients and reduce surgeon uncertainty regarding decision-making, we designed an Internet-enhanced multidisciplinary team (iMDT) working approach. METHODS: From August 2012 to April 2014, the iMDT discussed 215 patients with 266 metal-on-metal hip arthroplasties. Of these, 236 primary arthroplasties (132 hip resurfacing and 104 total hip) were analyzed. The remaining thirty cases involved problematic revised hips and were therefore excluded. The possible recommendations of the iMDT were monitoring, further investigation, or surgery. The concordance between the recommendation and the actual management was used to assess the usefulness of this approach in reducing uncertainty in surgeon-level decision-making. RESULTS: The median Oxford Hip Score was 35 (range, 4 to 48), and median cobalt and chromium levels in whole blood were 3.54 ppb (range, 0.18 to 161.46 ppb) and 3.17 ppb (range, 0.20 to 100.67 ppb), respectively. Magnetic resonance imaging revealed abductor muscle atrophy in ninety-two (39%) of the hips and a pseudotumor in eighty (34%). The iMDT recommended monitoring of 146 (61.9%) of the hips, further investigation of thirty (12.7%), and surgery in sixty (25.4%). The actual outcome was concordant with the recommendation in 211 (91.7%) of the hips. CONCLUSIONS: Our iMDT approach to the metal-on-metal hip burden combines the tacit knowledge of an expert panel, regulatory guidance, and up-to-date evidence to improve decision-making among surgeons. The high level of concordance between the recommendation and the actual outcome, combined with the feasibility of the methods used, suggest that this method effectively reduces uncertainty among surgeons and may lead to improved patient outcomes.


Equipment Failure Analysis/methods , Hip Prosthesis/classification , Interdisciplinary Communication , Internet , Patient Care Team/organization & administration , Social Media/organization & administration , Atrophy/diagnosis , Chromium/blood , Cobalt/blood , Diagnosis, Differential , Humans , Joint Diseases/complications , Joint Diseases/diagnosis , Magnetic Resonance Imaging , Muscle, Skeletal/pathology , Prosthesis Design , Prosthesis Failure/etiology , Risk Assessment , United Kingdom
16.
Acta Orthop ; 86(3): 351-7, 2015 Jun.
Article En | MEDLINE | ID: mdl-25588091

BACKGROUND AND PURPOSE: Muscle atrophy is seen in patients with metal-on-metal (MOM) hip implants, probably because of inflammatory destruction of the musculo-tendon junction. However, like pseudotumors, it is unclear when atrophy occurs and whether it progresses with time. Our objective was to determine whether muscle atrophy associated with MOM hip implants progresses with time. PATIENTS AND METHODS: We retrospectively reviewed 74 hips in 56 patients (32 of them women) using serial MRI. Median age was 59 (23-83) years. The median time post-implantation was 83 (35-142) months, and the median interval between scans was 11 months. Hip muscles were scored using the Pfirrmann system. The mean scores for muscle atrophy were compared between the first and second MRI scans. Blood cobalt and chromium concentrations were determined. RESULTS: The median blood cobalt was 6.84 (0.24-90) ppb and median chromium level was 4.42 (0.20-45) ppb. The median Oxford hip score was 34 (5-48). The change in the gluteus minimus mean atrophy score between first and second MRI was 0.12 (p = 0.002). Mean change in the gluteus medius posterior portion (unaffected by surgical approach) was 0.08 (p = 0.01) and mean change in the inferior portion was 0.10 (p = 0.05). Mean pseudotumor grade increased by 0.18 (p = 0.02). INTERPRETATION: Worsening muscle atrophy and worsening pseudotumor grade occur over a 1-year period in a substantial proportion of patients with MOM hip implants. Serial MRI helps to identify those patients who are at risk of developing worsening soft-tissue pathology. These patients should be considered for revision surgery before irreversible muscle destruction occurs.


Arthroplasty, Replacement, Hip/instrumentation , Hip Joint/surgery , Hip Prosthesis/adverse effects , Metal-on-Metal Joint Prostheses/adverse effects , Muscular Atrophy/epidemiology , Muscular Atrophy/etiology , Adult , Aged , Aged, 80 and over , Chromium/blood , Cobalt/blood , Disease Progression , Female , Humans , Incidence , Magnetic Resonance Imaging , Male , Middle Aged , Muscular Atrophy/pathology , Reoperation , Retrospective Studies , Time Factors
17.
J Arthroplasty ; 30(4): 687-94, 2015 Apr.
Article En | MEDLINE | ID: mdl-25583682

SPECT-CT is increasingly used to assess painful knee arthroplasties. The aim of this study was to evaluate the clinical usefulness of SPECT-CT in unexplained painful MOM hip arthroplasty. We compared the diagnosis and management plan for 19 prosthetic MOM hips in 15 subjects with unexplained pain before and after SPECT-CT. SPECT-CT changed the management decision in 13 (68%) subjects, Chi-Square=5.49, P=0.24. In 6 subjects (32%) pain remained unexplained however the result reassured the surgeon to continue with non-operative management. SPECT-CT should be reserved as a specialist test to help identify possible causes of pain where conventional investigations have failed. It can help reassure surgeons making management decisions for patients with unexplained pain following MOM hip arthroplasty.


Arthralgia/diagnostic imaging , Arthroplasty, Replacement, Hip/adverse effects , Hip Joint/surgery , Metal-on-Metal Joint Prostheses , Tomography, Emission-Computed, Single-Photon , Adult , Aged , Arthralgia/etiology , Female , Humans , Male , Middle Aged , Pain Measurement , Prosthesis Failure , Reoperation
18.
J Arthroplasty ; 29(6): 1313-7, 2014 Jun.
Article En | MEDLINE | ID: mdl-24411082

It has been suggested that corrosion and fretting at the tapered, modular junctions of hip arthroplasties may contribute to implant failure. In this study the reliability of a commonly used peer-reviewed scoring system for visual assessment of corrosion and fretting at these junctions was evaluated. Volumetric material loss at the tapered head surface was measured and associations with the visual scores were investigated. We found that the inter-observer reproducibility and single-observer repeatability of the corrosion scores were substantial using Cohen's weighted Kappa statistic (k = 0.64-0.71). The reproducibility and repeatability of the fretting scores however were slight to fair (k = 0.18-0.31). Taper corrosion scores were significantly and moderately correlated with the volume of material loss measured (Spearman's r = 0.59; P < 0.001). We recommend the continued use of this scoring system but it should not be a substitute for measurement of material loss.


Hip Prosthesis/adverse effects , Prosthesis Failure , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/instrumentation , Corrosion , Device Removal , Equipment Failure Analysis , Female , Femur/surgery , Humans , Male , Materials Testing , Middle Aged , Prosthesis Design , Reoperation , Reproducibility of Results , Retrospective Studies
19.
Injury ; 45(4): 757-65, 2014 Apr.
Article En | MEDLINE | ID: mdl-24377482

This study demonstrates the utility of a modified postero-medial surgical approach to the knee in treating a series of patients with complex tibial plateau injuries with associated postero-medial and postero-lateral shear fractures. Posterior coronal shear fractures are underappreciated and their clinical relevance has recently been characterised. Less-invasive surgery and indirect reduction techniques are inadequate for treating these coronal plane fractures. Our approach includes an inverted 'L'-shaped incision situated within the posterior flexor knee crease, followed by the retraction or incision of the medial head of the gastrocnemius tendon, while protecting the neurovascular structures. This provides a more extensile exposure, as far as the postero-lateral corner, than previously described. Our case series included eight females and eight males. The average age was 53 years. The majority of these injuries were sustained through high-energy trauma. All patients' fractures were classified as Schatzker grade 4, or above, with a postero-medial split depression. Eight patients had associated postero-lateral corner fractures. Two were open, two had vascular compromise and one had neurological injury. The average time to surgery was 6.4 days (range 0-12), operative time 142 min (range 76-300) and length of stay 17 days (range 7-46). A total of 11 patients were treated using the postero-medial approach alone and in five the treatment was combined with an antero-lateral approach. Two patients suffered a reduced range of movement requiring manipulation and physiotherapy, and three patients had a 5-degree fixed flexion deformity. Two patients developed superficial wound infections treated with antibiotics alone. Anatomical reduction and fracture union was achieved in 15 patients. These are complex fractures to treat, and our modified posterior approach allows direct reduction and optimal positioning of plates to act as buttress devices. It can be extended across the midline to the postero-lateral corner and also allows excellent exposure of the popliteal vessels should concurrent vascular repair be required.


Bone Plates , Fracture Fixation, Internal/methods , Knee Injuries/surgery , Knee Joint/surgery , Suture Techniques , Tibial Fractures/surgery , Adult , Aged , Female , Follow-Up Studies , Fracture Healing , Humans , Knee Injuries/diagnostic imaging , Knee Injuries/physiopathology , Knee Joint/physiopathology , Length of Stay/statistics & numerical data , Male , Middle Aged , Range of Motion, Articular , Recovery of Function , Shear Strength , Tibial Fractures/diagnostic imaging , Tibial Fractures/physiopathology , Tomography, X-Ray Computed , Treatment Outcome
...