Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Dentomaxillofac Radiol ; 49(6): 20190468, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32267774

RESUMEN

OBJECTIVES: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. METHODS: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (PKA). RESULTS: 227 answers were collected (38% of all centers). Third quartile of PKA values were obtained for five dental indications: 662 mGy cm² for wisdom tooth, 683 mGy cm² for single tooth implant treatment, 542 mGy cm² for tooth position anomalies, 569 mGy cm² for pathological dentoalveolar modifications, and 639 mGy cm² for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. CONCLUSIONS: Large ranges of FOV and PKA were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Dosis de Radiación , Valores de Referencia , Encuestas y Cuestionarios , Suiza
3.
BMC Med Ethics ; 16: 43, 2015 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-26088562

RESUMEN

BACKGROUND: Overtreatment (or unnecessary treatment) is when medical or dental services are provided with a higher volume or cost than is appropriate. This study aimed to investigate how a group of dentists in Switzerland, a wealthy country known to have high standards of healthcare including dentistry, evaluated the meaning of unnecessary treatments from an ethical perspective and, assessed the expected frequency of different possible behaviors among their peers. METHODS: A vignette describing a situation that is susceptible for overtreatment of a patient was presented to a group of dentists. The vignette was followed by five options. A questionnaire including the vignette was posted to 2482 dentists in the German-speaking areas of Switzerland. The respondents were asked to rate each option according to their estimation about its prevalence and their judgment about the degree to which the behavior is ethically sound. RESULTS: 732 completed questionnaires were returned. According to the responses, the most ethical and the most unethical options are considered to be the most and the least prevalent behaviors among dentists practicing in Switzerland, respectively. CONCLUSIONS: Suggesting unnecessary treatments to patients seems to be an ethically unacceptable conduct in the eyes of a sample of dentists in Switzerland. Although the respondents believed their colleagues were very likely to behave in an ethical way in response to a situation that is susceptible to overtreatment, they still seemed to be concerned about the prevalence of unethical behaviors in this regard.


Asunto(s)
Actitud del Personal de Salud , Odontólogos/ética , Ética Odontológica , Pautas de la Práctica en Odontología/ética , Procedimientos Innecesarios/ética , Adulto , Femenino , Humanos , Masculino , Uso Excesivo de los Servicios de Salud , Persona de Mediana Edad , Relaciones Médico-Paciente , Encuestas y Cuestionarios , Suiza
5.
Eur Radiol ; 22(2): 358-63, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21842433

RESUMEN

OBJECTIVE: To demonstrate feasibility of near-real-time oculodynamic magnetic resonance imaging (od-MRI) in depicting extraocular muscles and correlate quantitatively the motion degree in comparison with clinical testing in patients with diplopia. METHODS: In 30 od-MRIs eye movements were tracked in the horizontal and sagittal plane using a a TrueFISP sequence with high temporal resolution. Three physicians graded the visibility of extraocular muscles by a qualitative scale. In 12 cases, the maximal monocular excursions in the horizontal and vertical direction of both eyes were measured in od-MRIs and a clinical test and correlated by the Pearson test. RESULTS: The medial and lateral rectus muscles were visible in the axial plane in 93% of the cases. The oblique, superior and inferior rectus muscles were overall only in 14% visible. Horizontal (p = 0,015) and vertical (p = 0,029) movements of the right eye and vertical movement of the left eye (p = 0,026) measured by od-MRI correlated positively to the clinical measurements. CONCLUSIONS: Od-MRI is a feasible technique. Visualization of the horizontal/vertical rectus muscles is better than for the superior/inferior oblique muscle. Od-MRI correlates well with clinical testing and may reproduce the extent of eye bulb motility and extraocular muscle structural or functional deteriorations. Key Points • Oculodynamic MRI technique helps clinicians to assess eye bulb motility disorders • MRI evaluation of eye movement provides functional information in cases of diplopia • Oculodynamic MRI reproduces excursion of extraocular muscles with good correlation with clinical testing • Dynamic MRI sequence supplements static orbital protocol for evaluation of motility disorders.


Asunto(s)
Diplopía/diagnóstico , Diplopía/patología , Imagen por Resonancia Magnética/métodos , Trastornos de la Motilidad Ocular/patología , Músculos Oculomotores/patología , Órbita/patología , Adulto , Movimientos Oculares , Estudios de Factibilidad , Humanos , Imagen por Resonancia Cinemagnética/métodos , Persona de Mediana Edad , Modelos Estadísticos , Movimiento , Trastornos de la Motilidad Ocular/diagnóstico , Reproducibilidad de los Resultados
7.
J AAPOS ; 13(3): 322-4, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19541279

RESUMEN

Different mechanisms have been hypothesized as contributing to abduction deficit in high myopia: the size of the eye within the orbit, tightness of the medial rectus muscles, decompensation of longstanding esotropia, and inferior displacement of the lateral rectus muscle. Using oculodynamic magnetic resonance imaging, enhanced by computer-aided visualization, we demonstrate globe restriction by the medial orbital wall on abduction in a patient with high myopia.


Asunto(s)
Esotropía/patología , Imagen por Resonancia Magnética/métodos , Miopía/patología , Órbita/patología , Adulto , Esotropía/fisiopatología , Movimientos Oculares , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Miopía/fisiopatología , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...