Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Microvasc Res ; 130: 104000, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32194082

RESUMEN

INTRODUCTION: Impaired oxygenation in the skin may occur in disease states and after reconstructive surgery. We used tissue viability imaging (TiVi) to measure changes in oxygenation and deoxygenation of haemoglobin in an in vitro model and in the dermal microcirculation of healthy individuals. MATERIALS AND METHODS: Oxygenation was measured in human whole blood with different levels of oxygenation. In healthy subjects, changes in red blood cell concentration (CRBC,TiVi), oxygenation (ΔCOH,TiVi) and deoxygenation (ΔCDOH,TiVi) of haemoglobin were measured during and after arterial and venous occlusion using TiVi and were compared with measurements from the enhanced perfusion and oxygen saturation system (EPOS). RESULTS: During arterial occlusion, CRBC,TiVi remained unchanged while ΔCOH,TiVi decreased to -44.2 (10.4) AU (p = 0.04), as compared to baseline. After release, CRBC,TiVi increased to 39.2 (18.8) AU (p < 0.001), ΔCOH,TiVi increased to 38.5. During venous occlusion, CRBC,TiVi increased to 28.9 (11.2) AU (p < 0.001), ΔCOH,TiVi decreased to -52.2 (46.1) AU (p < 0.001) compared to baseline after 5 min of venous occlusion. There was a significant correlation between the TiVi Oxygen Mapper and EPOS, for arterial (r = 0.92, p < 0.001) and venous occlusion (r = 0.87, p < 0.001), respectively. CONCLUSION: This study shows that TiVi can measure trends in oxygenation and deoxygenation of haemoglobin during arterial and venous stasis in healthy individuals.


Asunto(s)
Hemoglobinas/metabolismo , Microcirculación , Oxihemoglobinas/metabolismo , Piel/irrigación sanguínea , Adulto , Velocidad del Flujo Sanguíneo , Recuento de Eritrocitos , Femenino , Antebrazo , Voluntarios Sanos , Humanos , Hiperemia/fisiopatología , Flujometría por Láser-Doppler , Masculino , Flujo Sanguíneo Regional , Análisis Espectral , Factores de Tiempo , Adulto Joven
2.
Plast Reconstr Surg Glob Open ; 5(11): e1531, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29263951

RESUMEN

BACKGROUND: Venous congestion in skin flaps is difficult to detect. This study evaluated the ability of tissue viability imaging (TiVi) to measure changes in the concentration of red blood cells (CRBC), oxygenation, and heterogeneity during vascular provocations in a porcine fasciocutaneous flap model. METHODS: In 5 pigs, cranial gluteal artery perforator flaps were raised (8 flaps in 5 pigs). The arterial and venous blood flow was monitored with ultrasonic flow probes. CRBC, tissue oxygenation, and heterogeneity in the skin were monitored with TiVi during baseline, 50% and 100% venous occlusion, recovery, 100% arterial occlusion and final recovery, thereby simulating venous and arterial occlusion of a free fasciocutaneous flap. A laser Doppler probe was used as a reference for microvascular perfusion in the flap. RESULTS: During partial and complete venous occlusion, increases in CRBC were seen in different regions of the flap. They were more pronounced in the distal part. During complete arterial occlusion, CRBC decreased in all but the most distal parts of the flap. There were also increases in tissue oxygenation and heterogeneity during venous occlusion. CONCLUSIONS: TiVi measures regional changes in CRBC in the skin of the flap during arterial and venous occlusion, as well as an increase in oxygenated hemoglobin during venous occlusion that may be the result of reduced metabolism and impaired delivery of oxygen to the tissue. TiVi may provide a promising method for measuring flap viability because it is hand-held, easy to-use, and provides spatial information on venous congestion.

3.
J Plast Reconstr Aesthet Surg ; 69(7): 936-43, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27026039

RESUMEN

BACKGROUND: In microsurgery, there is a demand for more reliable methods of post-operative monitoring of free flaps, especially with regard to tissue-threatening obstructions of the feeding arteries and draining veins. In this study, we evaluated laser speckle contrast imaging (LSCI) and laser Doppler flowmetry (LDF) to assess their possibilities to detect partial and full venous outflow obstruction, as well as full arterial occlusion, in a porcine flap model. METHODS: Cranial gluteal artery perforator flaps (CGAPs) were raised, and arterial and venous blood flow to and from the flaps was monitored using ultrasonic flow probes. The venous flow was altered with an inflatable cuff to simulate partial and full (50% and 100%) venous obstruction, and arterial flow was completely obstructed using clamps. The flap microcirculation was monitored using LSCI and LDF. RESULTS: Both LDF and the LSCI detected significant changes in flap perfusion. After partial (50%) venous occlusion, perfusion decreased from baseline, LSCI: 63.5 ± 12.9 PU (p = 0.01), LDF 31.3 ± 15.7 (p = 0.64). After 100% venous occlusion, a further decrease in perfusion was observed: LSCI 54.6 ± 14.2 PU (p < 0.001) and LDF 16.7 ± 12.8 PU (p < 0.001). After release of the venous cuff, LSCI detected a return of the perfusion to a level slightly, but not significantly, below the baseline level 70.1 ± 11.5 PU (p = 0.39), while the LDF signal returned to a level not significant from the baseline 36.1 ± 17.9 PU (p > 0.99). Perfusion during 100% arterial occlusion decreased significantly as measured with both methods, LSCI: 48.3 ± 7.7 (PU, p < 0.001) and LDF: 8.5 ± 4.0 PU (p < 0.001). During 50% and 100% venous occlusion, LSCI showed a 20% and 26% intersubject variability (CV%), respectively, compared to 50% and 77% for LDF. CONCLUSIONS: LSCI offers sensitive and reproducible measurements of flap microcirculation and seems more reliable in detecting decreases in blood perfusion caused by venous obstruction. It also allows for perfusion measurements in a relatively large area of flap tissue. This may be useful in identifying areas of the flap with compromised microcirculation during and after surgery.


Asunto(s)
Arteriopatías Oclusivas , Arterias , Colgajos Tisulares Libres , Microcirugia/efectos adversos , Procedimientos de Cirugía Plástica/efectos adversos , Complicaciones Posoperatorias , Venas , Animales , Arteriopatías Oclusivas/diagnóstico , Arteriopatías Oclusivas/fisiopatología , Arterias/diagnóstico por imagen , Arterias/fisiopatología , Velocidad del Flujo Sanguíneo , Colgajos Tisulares Libres/efectos adversos , Colgajos Tisulares Libres/irrigación sanguínea , Hemodinámica , Flujometría por Láser-Doppler/métodos , Microcirugia/métodos , Modelos Anatómicos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/prevención & control , Procedimientos de Cirugía Plástica/métodos , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Porcinos , Grado de Desobstrucción Vascular , Venas/diagnóstico por imagen , Venas/fisiopatología
4.
Microvasc Res ; 101: 20-5, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26092681

RESUMEN

BACKGROUND: Venous occlusion in the skin is difficult to detect by existing measurement techniques. Our aim was to find out whether Tissue Viability Imaging (TiVi) was better at detecting venous occlusion by comparing it with results of laser Doppler flowmetry (LDF) during graded arterial and venous stasis in human forearm skin. METHODS: Arterial and venous occlusions were simulated in 10 healthy volunteers by inflating a blood pressure cuff around the upper right arm. Changes in the concentration of red blood cells (RBC) were measured using TiVi, while skin perfusion and concentration of moving red blood cells (CMBC) were measured using static indices of LDF during exsanguination and subsequent arterial occlusion, postocclusive reactive hyperaemia, and graded increasing and decreasing venous stasis. RESULTS: During arterial occlusion there was a significant reduction in the mean concentration of RBC from baseline, as well as in perfusion and CMBC (p<0.008). Venous occlusion resulted in a significant 28% increase in the concentration of RBC (p=0.002), but no significant change in perfusion (mean change -14%) while CMBC decreased significantly by 24% (p=0.02). With stepwise increasing occlusion pressures there was a significant rise in the TiVi index and reduction in perfusion (p=0.008), while the reverse was seen when venous flow was gradually restored. CONCLUSION: The concentration of RBC measured with TiVi changes rapidly and consistently during both total and partial arterial and venous occlusions, while the changes in perfusion, measured by LDF, were less consistent. This suggests that TiVi could be a more useful, non-invasive clinical monitoring tool for detecting venous stasis in the skin than LDF.


Asunto(s)
Arterias/patología , Microcirculación , Piel/irrigación sanguínea , Piel/patología , Venas/patología , Adolescente , Adulto , Velocidad del Flujo Sanguíneo , Movimiento Celular , Eritrocitos/citología , Femenino , Antebrazo , Humanos , Hiperemia/fisiopatología , Flujometría por Láser-Doppler , Masculino , Perfusión , Flujo Sanguíneo Regional , Supervivencia Tisular , Adulto Joven
5.
Microcirculation ; 19(8): 705-13, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22716906

RESUMEN

OBJECTIVE: To evaluate whether TiVi, a technique based on polarized light, could measure the change in RBC concentration during local heating in healthy volunteers. METHODS: Using a custom-made transparent heater, forearm skin was heated to 42 °C for 40 minutes while the change in RBC concentration was measured with TiVi. The perfusion response during local heating was measured at the same time with Laser Doppler flowmetry. RESULTS: Mean RBC concentration increased (91 ± 34 vs. 51 ± 34 A.U. at baseline, p < 0.001). The spatial heterogeneity of the RBC concentration in the measured skin areas was 26 ± 6.4% at baseline, and 23 ± 4.6% after 40 minutes of heating. The mean RBC concentrations in two skin sites were highly correlated (0.98 at baseline and 0.96 after 40 minutes of heating). The change in RBC concentration was less than the change in perfusion, measured with LDF. Unlike with LDF, a neurally mediated peak was not observed with TiVi in most of the test subjects. CONCLUSIONS: TiVi is a valuable technique for measuring the microvascular response to local heating in the skin, and offers a high reproducibility for simultaneous measurements at different skin sites, provided carefully controlled experiments are ensured.


Asunto(s)
Eritrocitos/metabolismo , Calor , Luz , Microcirculación/efectos de la radiación , Piel/irrigación sanguínea , Adulto , Femenino , Humanos , Masculino
6.
J Trauma Acute Care Surg ; 72(2): 504-12, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22439224

RESUMEN

BACKGROUND: Health-related quality of life (HRQoL) is known to be significantly affected in former trauma patients. However, the underlying factors that lead to this outcome are largely unknown. In former intensive care unit (ICU) patients, it has been recognized that preexisting disease is the most important factor for the long-term HRQoL. The aim of this study was to investigate HRQoL up to2 years after trauma and to examine the contribution of the trauma-specific, ICU-related, sociodemographic factors together with the effects of preexisting disease, and further to make a comparison with a large general population. METHODS: A prospective 2-year multicenter study in Sweden of 108 injured patients. By mailed questionnaires, HRQoL was assessed at 6 months,12 months, and 24 months after the stay in ICU by Short Form (SF)-36, and information of preexisting disease was collected from the national hospital database. ICU-related factors were obtained from the local ICU database. Comorbidity and HRQoL (SF-36) was also examined in the reference group, a random sample of 10,000 inhabitants in the uptake area of the hospitals. RESULTS: For the trauma patients, there was a marked and early decrease in the physical dimensions of the SF-36 (role limitations due to physical problems and bodily pain). This decrease improved rapidly and was almost normalized after 24 months. In parallel, there were extensive decreases in the psychologic dimensions (vitality, social functioning, role limitations due to emotional problems,and mental health) of the SF-36 when comparisons were made with the general reference population. CONCLUSIONS: The new and important finding in this study is that the trauma population seems to have a trauma-specific HRQoL outcome pattern.First, there is a large and significant decrease in the physical dimensions of the SF-36, which is due to musculoskeletal effects and pain secondary to the trauma. This normalizes within 2 years, whereas the overall decrease in HRQoL remains and most importantly it is seen mainly in the psychologic dimensions and it is due to preexisting diseases.


Asunto(s)
Calidad de Vida , Sobrevivientes/psicología , Heridas y Lesiones/fisiopatología , Heridas y Lesiones/psicología , Adulto , Distribución de Chi-Cuadrado , Comorbilidad , Femenino , Humanos , Unidades de Cuidados Intensivos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Análisis de Regresión , Encuestas y Cuestionarios , Suecia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...