Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Cardiovasc Transl Res ; 15(1): 84-94, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34115322

RESUMEN

High-frequency QRS (HFQRS) analysis of surface ECG is a reliable marker of cardiac ischemia (CI). This study aimed to assess the response of HFQRS signals from standard intracardiac electrodes (iHFQRS) to CI in swine and compare them with conventional ST-segment deviations. Devices with three intracardiac leads were implanted in three swine in a controlled environment. CI was induced by inflating a balloon in epicardial coronary arteries. A designated signal-processing algorithm was applied to quantify the iHFQRS content before, during, and after each occlusion. iHFQRS time responses were compared to conventional ST-segment deviations. Thirty-three over thirty-nine (85%) of the occlusions presented significant reduction in the iHFQRS signal, preceding ST-segment change, being the only indicator of CI in brief occlusions. iHFQRS was found to be an early indicator for the onset of CI and demonstrated superior sensitivity to conventional ST-segment deviations during brief ischemic episodes.


Asunto(s)
Enfermedad de la Arteria Coronaria , Isquemia Miocárdica , Animales , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Isquemia , Isquemia Miocárdica/diagnóstico , Porcinos
2.
Magn Reson Med ; 78(3): 860-870, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-27690262

RESUMEN

PURPOSE: Osteoporosis is characterized by a decrease in bone mineral density (BMD). A preliminary stage of the disease is progressive bone marrow adiposity, caused by imbalance between osteogenesis and adipogenesis in the marrow. Detection of osteoporosis relies on the quantification of BMD with techniques such as dual-energy X-ray absorptiometry. This work aimed to detect bone marrow changes in an experimental model of osteopenia using a low-field tabletop NMR scanner. METHODS: An experiment was performed on 32 female rats, 3 months old, 16 of which were ovariectomized (OVX) and 16 were sham-operated (sham). The femur and tibia from both hind limbs were isolated and underwent ex vivo NMR scans at four time points after the OVX and sham operations. NMR scans were complemented by BMD measurements and histology. RESULTS: Significant changes in the bone marrow of ovariectomized rats, relative to sham operated rats, were observed after 3.5 and 4.5 months. Bone marrow adiposity was detected by significant changes in T1 and T2 relaxation times, and in the diffusion coefficient. CONCLUSIONS: This study suggests a potential detection of changes to the bone marrow using a tabletop NMR device. Clinical translation may facilitate screening, early detection of bone weakening as a result of estrogen withdrawal, and monitoring of treatment efficacy. Magn Reson Med 78:860-870, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Médula Ósea/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Osteoporosis/diagnóstico por imagen , Animales , Densidad Ósea , Médula Ósea/química , Femenino , Fémur/diagnóstico por imagen , Ovariectomía , Ratas , Ratas Sprague-Dawley , Tibia/diagnóstico por imagen
3.
NMR Biomed ; 28(6): 656-66, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25900247

RESUMEN

Human skin undergoes morphological and biochemical changes as a result of chronological aging and exposure to solar ultraviolet irradiation (photoaging). Noninvasive detection of these changes may aid in the prevention and treatment of both types of aging. This article presents a noninvasive method for the evaluation of aging skin with a unilateral stray field NMR scanner. These portable and inexpensive scanners may be suitable for in-depth skin characterization. In vivo profiles of sun-protected and sun-exposed skin from the forearms of female subjects of different ages (n = 9) were measured. Skin biopsies for histopathological examination were used as reference. T2 analysis with a bi-exponential decay model was applied and the extracted parameters were examined as markers for dermal aging. In the upper reticular dermis, a significant increase in the fraction of the slow T2 component and in the T2 value itself was found to correlate with chronological aging. For most subjects, there was an additional increase in the values of the slow T2 component and the T2 values from the sun-exposed forearm, superimposed on that measured for the sun-protected forearm. These results are in agreement with the decline in collagen content and the increase in free water content with aging. The results suggest that such a technique can be used as a tool for the assessment of aging, and that bi-exponential fitting can produce sensitive fingerprint parameters for the dermal alterations that occur during aging.


Asunto(s)
Espectroscopía de Resonancia Magnética/instrumentación , Envejecimiento de la Piel/fisiología , Envejecimiento de la Piel/efectos de la radiación , Piel/química , Piel/efectos de la radiación , Luz Solar , Adulto , Anciano , Anciano de 80 o más Años , Envejecimiento/fisiología , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Espectroscopía de Resonancia Magnética/métodos , Persona de Mediana Edad , Modelos Biológicos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
4.
J Magn Reson ; 245: 87-93, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25023564

RESUMEN

Unilateral NMR devices are valuable tools used to study non-invasively arbitrarily-sized objects. They have been utilized in various applications, including non-destructive testing and well logging. However, measurements with such scanners are characterized by a low sensitivity, which is mainly the result of the low and inhomogeneous magnetic field B0. The resulting poor signal to noise ratio (SNR) is a prominent limitation, as it deteriorates the accuracy of data analysis. Improving the SNR is typically done by the use of averaging repetitions that result in too long scan times. This work presents a statistical signal-processing method that can improve the sensitivity of a Carr-Purcell-Meiboom-Gill (CPMG)-like sequence for measurements of transverse-relaxation with unilateral scanners. The method improves the extraction of the decay curve from the noisy data. This is done by exploiting the redundancy in the acquired signal and by the use of the noise characteristics, which are both incorporated into a weighted least-squares estimation approach. This technique is especially effective in applications where RF shielding is not in use, and the measurements are corrupted by dominant non-white noise. The method performance was evaluated with a series of CPMG-like measurements applied on two samples. Decay curves were extracted from each measurement with the proposed method and were compared to a conventional extraction of the decay curve. All measurements showed a significant improvement in the accuracy of estimation of the decaying signal. Thus, the improvement in the sensitivity can be translated into a reduction in the acquisition times (by reducing the need in averaging repetitions) or to a more accurate fitting process of the traverse relaxation distribution.

5.
J Magn Reson ; 237: 92-99, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24184709

RESUMEN

Unilateral NMR devices are used in various applications including non-destructive testing and well logging, but are not used routinely for imaging. This is mainly due to the inhomogeneous magnetic field (B0) in these scanners. This inhomogeneity results in low sensitivity and further forces the use of the slow single point imaging scan scheme. Improving the measurement sensitivity is therefore an important factor as it can improve image quality and reduce imaging times. Short imaging times can facilitate the use of this affordable and portable technology for various imaging applications. This work presents a statistical signal-processing method, designed to fit the unique characteristics of imaging with a unilateral device. The method improves the imaging capabilities by improving the extraction of image information from the noisy data. This is done by the use of redundancy in the acquired MR signal and by the use of the noise characteristics. Both types of data were incorporated into a Weighted Least Squares estimation approach. The method performance was evaluated with a series of imaging acquisitions applied on phantoms. Images were extracted from each measurement with the proposed method and were compared to the conventional image reconstruction. All measurements showed a significant improvement in image quality based on the MSE criterion - with respect to gold standard reference images. An integration of this method with further improvements may lead to a prominent reduction in imaging times aiding the use of such scanners in imaging application.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Relación Señal-Ruido
6.
J Magn Reson ; 231: 72-8, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23597948

RESUMEN

Unilateral NMR devices are important tools in various applications such as non-destructive testing and well logging, but are not applied routinely for imaging, primarily because B0 inhomogeneity in these scanners leads to a relatively low signal and requires use of the slow single point imaging scan scheme. Enabling high quality, fast imaging could make this affordable and portable technology practical for various imaging applications as well as for new applications that are not yet feasible with MRI technology. The goal of this work was to improve imaging times in a portable unilateral NMR scanner. Both Compressed Sensing and Fast Spin Echo were modified and applied to fit the unique characteristics of a unilateral device. Two printed phantoms, allowing high resolution images, were scanned with both methods and compared to a standard scan and to a low pass scan to evaluate performance. Both methods were found to be feasible with a unilateral device, proving ways to accelerate single point imaging in such scanners. This outcome encourages us to explore how to further accelerate imaging times in unilateral NMR devices so that this technology might become clinically applicable in the future.


Asunto(s)
Compresión de Datos/métodos , Imagen por Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización
7.
Opt Express ; 17(9): 7328-38, 2009 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-19399111

RESUMEN

In this paper the use of pulse shaping in photoacoustic (PA) measurements is presented. The benefits of this approach are demonstrated by utilizing it for optimization of either the responsivity or the sensitivity of PA measurements. The optimization is based on the observation that the temporal properties of the PA effect can be represented as a linear system which can be fully characterized by its impulse response. Accordingly, the response of the PA system to an input optical pulse, whose instantaneous power is arbitrarily shaped, can be analytically predicted via a convolution between the pulse envelope and the PA impulse response. Additionally, the same formalism can be used to show that the response of the PA system to a pulse whose instantaneous power is a reversed version of the impulse response, i.e. a matched pulse, would exhibit optimal peak amplitude when compared with all other pulses with the same energy. Pulses can also be designed to optimize the sensitivity of the measurement to a variation in a specific system parameter. The use of the matched pulses can improve SNR and enable a reduction in the total optical energy required for obtaining a detectable signal. This may be important for applications where the optical power is restricted or for dynamical measurements where long integration times are prohibited. To implement this new approach, a novel PA optical setup which enabled synthesis of excitation waveforms with arbitrary temporal envelopes was constructed. The setup was based on a tunable laser source, operating in the near-IR range, and an external electro-optic modulator. Using this setup, our approach for system characterization and response prediction was tested and the superiority of the matched pulses over other common types of pulses of equal energy was demonstrated.


Asunto(s)
Algoritmos , Diagnóstico por Imagen de Elasticidad/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA