Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Front Oncol ; 14: 1401464, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39091912

RESUMEN

Background and purpose: Biomarkers for prediction of outcome in patients with pancreatic cancer are wanted in order to personalize the treatment. This study investigated the value of longitudinal diffusion-weighted magnetic resonance imaging (DWI) for prediction of overall survival (OS) in patients with locally advanced pancreatic cancer (LAPC) treated with stereotactic body radiotherapy (SBRT). Materials and methods: The study included 45 patients with LAPC who received 5 fractions of 10 Gy on a 1.5T MRI-Linac. DWI was acquired prior to irradiation at each fraction. The analysis included baseline values and time-trends of the apparent diffusion coefficient (ADC) and DWI parameters obtained using a decomposition method. A multivariable Cox proportional hazards model for OS was made using best-subset selection, using cross-validation based on Bootstrap. Results: The median OS from the first day of SBRT was 15.5 months (95% CI: 13.2-20.6), and the median potential follow-up time was 19.8 months. The best-performing multivariable model for OS included two decomposition-based DWI parameters: one baseline and one time-trend parameter. The C-Harrell index describing the model's discriminating power was 0.754. High baseline ADC values were associated with reduced OS, whereas no association between the ADC time-trend and OS was observed. Conclusion: Decomposition-based DWI parameters indicated value in the prediction of OS in LAPC. A DWI time-trend parameter was included in the best-performing model, indicating a potential benefit of acquiring longitudinal DWI during the SBRT course. These findings support both baseline and longitudinal DWI as candidate prognostic biomarkers, which may become tools for personalization of the treatment of patients with LAPC.

2.
Radiother Oncol ; 197: 110347, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38815694

RESUMEN

PURPOSE: Stereotactic body radiotherapy (SBRT) has emerged as a promising new modality for locally advanced pancreatic cancer (LAPC). The current study evaluated the efficacy and toxicity of SBRT in patients with LAPC (NCT03648632). METHODS: This prospective single institution phase II study recruited patients with histologically or cytologically proven adenocarcinoma of the pancreas after more than two months of combination chemotherapy with no sign of progressive disease. Patients were prescribed 50-60 Gy in 5-8 fractions. Patients were initially treated on a standard linac (n = 4). Since 2019, patients were treated using online magnetic resonance (MR) image-guidance on a 1.5 T MRI-linac, where the treatment plan was adapted to the anatomy of the day. The primary endpoint was resection rate. RESULTS: Twenty-eight patients were enrolled between August 2018 and March 2022. All patients had non-resectable disease at time of diagnosis. Median follow-up from inclusion was 28.3 months (95 % CI 24.0-NR). Median progression-free and overall survival from inclusion were 7.8 months (95 % CI 5.0-14.8) and 16.5 months (95 % CI 10.7-22.6), respectively. Six patients experienced grade III treatment-related adverse events (jaundice, nausea, vomiting and/or constipation). One of the initial four patients receiving treatment on a standard linac experienced a grade IV perforation of the duodenum. Six patients (21 %) underwent resection. A further one patient was offered resection but declined. CONCLUSION: This study demonstrates that SBRT in patients with LAPC was associated with promising overall survival and resection rates. Furthermore, SBRT was safe and well tolerated, with limited severe toxicities.


Asunto(s)
Neoplasias Pancreáticas , Radiocirugia , Humanos , Radiocirugia/métodos , Radiocirugia/efectos adversos , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/patología , Neoplasias Pancreáticas/diagnóstico por imagen , Masculino , Femenino , Anciano , Persona de Mediana Edad , Estudios Prospectivos , Anciano de 80 o más Años , Radioterapia Guiada por Imagen/métodos , Adenocarcinoma/patología , Adenocarcinoma/radioterapia , Adenocarcinoma/cirugía , Adenocarcinoma/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos
3.
Front Oncol ; 13: 1285725, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38023233

RESUMEN

Background: Adaptive MRI-guided radiotherapy (MRIgRT) requires accurate and efficient segmentation of organs and targets on MRI scans. Manual segmentation is time-consuming and variable, while deformable image registration (DIR)-based contour propagation may not account for large anatomical changes. Therefore, we developed and evaluated an automatic segmentation method using the nnU-net framework. Methods: The network was trained on 38 patients (76 scans) with localized prostate cancer and tested on 30 patients (60 scans) with localized prostate, metastatic prostate, or bladder cancer treated at a 1.5 T MRI-linac at our institution. The performance of the network was compared with the current clinical workflow based on DIR. The segmentation accuracy was evaluated using the Dice similarity coefficient (DSC), mean surface distance (MSD), and Hausdorff distance (HD) metrics. Results: The trained network successfully segmented all 600 structures in the test set. High similarity was obtained for most structures, with 90% of the contours having a DSC above 0.9 and 86% having an MSD below 1 mm. The largest discrepancies were found in the sigmoid and colon structures. Stratified analysis on cancer type showed that the best performance was seen in the same type of patients that the model was trained on (localized prostate). Especially in patients with bladder cancer, the performance was lower for the bladder and the surrounding organs. A complete automatic delineation workflow took approximately 1 minute. Compared with contour transfer based on the clinically used DIR algorithm, the nnU-net performed statistically better across all organs, with the most significant gain in using the nnU-net seen for organs subject to more considerable volumetric changes due to variation in the filling of the rectum, bladder, bowel, and sigmoid. Conclusion: We successfully trained and tested a network for automatically segmenting organs and targets for MRIgRT in the male pelvis region. Good test results were seen for the trained nnU-net, with test results outperforming the current clinical practice using DIR-based contour propagation at the 1.5 T MRI-linac. The trained network is sufficiently fast and accurate for clinical use in an online setting for MRIgRT. The model is provided as open-source.

4.
Phys Med ; 114: 102682, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37717398

RESUMEN

PURPOSE: The current study investigated the impact of abdominal compression on motion and the delivered dose during non-gated, magnetic resonance image (MRI)-guided radiation ablation of adrenal gland metastases. METHODS: Thirty-one patients with adrenal gland metastases treated to 45-60 Gy in 3-8 fractions on a 1.5 T MRI-linac were included in the study. The patients were breathing freely (n = 14) or with motion restricted by using an abdominal compression belt (n = 17). The time-resolved position of the target in online 2D cine MR images acquired during treatment was assessed and used to estimate the dose delivered to the GTV and abutting luminal organs at risk (OAR). RESULTS: The median (range) 3D root-mean-square target position error was significantly higher in patients treated without a compression belt [2.9 (1.9-5.6) mm] compared to patients using the belt [2.1 (1.2-3.5) mm] (P < 0.01). The median (range) GTV V95% was significantly reduced from planned 98.6 (65.9-100) % to delivered 96.5 (64.5-99.9) % due to motion (P < 0.01). Most prominent dose reductions were found in patients showing either large target drift or respiration motion and were mainly treated without abdominal compression. Motion did not lead to an increased number of constraint violations for luminal OAR. CONCLUSIONS: Acceptable target coverage and dose to OAR was observed in the vast majority of patients despite intra-fractional motion during adaptive MRI-guided radiation ablation. The use of abdominal compression significantly reduced the target position error and prevented the most prominent target coverage degradations and is, therefore, recommended as motion management at MRI-linacs.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Radiocirugia , Radioterapia Guiada por Imagen , Humanos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Radioterapia Guiada por Imagen/métodos , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/radioterapia , Glándulas Suprarrenales
5.
Phys Imaging Radiat Oncol ; 24: 167-172, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36439329

RESUMEN

Background and purpose: 3D Magnetic Resonance Imaging (MRI) is used in radiation therapy for reference planning and, lately, for adaptive treatments on MR accelerators. This study aimed to investigate the impact of different types of respiratory motion on the apparent target position and extent in such scans. Materials and methods: An MRI motion phantom with a 30 mm diameter target was used to simulate cranial-caudal (CC) motion and imaged at an MR-Linac using a standard clinically released 3D T2w sequence. Scans were acquired for each combination of functions (sin(t), sin4(t) and sin12(t)), peak-to-peak amplitudes (5, 10, 15 and 20 mm), and periods (4, 5 and 6 s). Furthermore, respiration CC motion patterns from two patients were used. Motion functions were shifted such that the time average target position would match a static reference scan at 0-position. The target was automatically identified in coronal and sagittal images using k-means clustering. The mean position and area of the target were calculated and compared to the reference scan. Results: Artefacts increased with amplitude and depended on the motion type. Sin(t) and sin4(t) oscillations resulted in a blurring of the target, which led to an increased target area, while sin12(t) motion did not show significant changes in the target area. However, for the sin12(t) motion, the offset in apparent position was prominent, while that was not the case for the sin(t) and sin4(t) motion. The patient respiration motion profiles showed similar trends. Conclusions: In 3D MRI, target motion can change apparent tumour extent and apparent position. The changes increase with motion amplitude and depend on the motion type.

6.
Radiother Oncol ; 172: 126-133, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35545166

RESUMEN

INTRODUCTION: In a recent study, setup uncertainties in the direction of the heart were shown to impact the overall survival of non-small cell lung cancer (NSCLC) patients after radiotherapy, indicating the causal effect between heart irradiation and survival. The current study aims to externally evaluate this observation within a patient cohort treated using daily IGRT. METHOD: NSCLC patients with locally-advanced disease and daily CBCT were included. For all treatment fractions, the distance between the isocenter and the heart was evaluated based on the clinical setup registrations. The variation in heart position between planning and treatment (DeltaDistance) was estimated from these registrations. The possible impact of DeltaDistance on survival was analysed by a multivariable Cox model of overall survival, allowing for a time-dependent impact of DeltaDistance to allow for toxicity latency. RESULTS: Daily CBCT information was available for 489 patients at Odense University Hospital. The primary Cox model contained GTV volume, patient age, performance status, and DeltaDistance. DeltaDistance significantly impacted overall survival approximately 50 months after radiotherapy. Subanalyses indicated that the observed effect is mainly present among the patients with the least clinical risk factors. CONCLUSION: Our results confirm the impact of setup variations in the direction of the heart on the survival of NSCLC patients, even within a cohort using daily CBCT setup guidance. This result indicates a causal effect between heart irradiation and survival. It will be challenging to reduce the setup uncertainty even further; thus, increased focus on dose constraints on the heart seems warranted.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Humanos , Neoplasias Pulmonares/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Errores de Configuración en Radioterapia , Tórax
7.
Radiother Oncol ; 167: 165-171, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34923034

RESUMEN

BACKGROUND AND PURPOSE: With daily, MR-guided online adapted radiotherapy (MRgART) it may be possible to reduce the PTV in pelvic RT. This study investigated the potential reduction in normal tissue complication probability (NTCP) of MRgART compared to standard radiotherapy for high-risk prostate cancer. MATERIALS AND METHODS: Twenty patients treated with 78 Gy to the prostate and 56 Gy to elective pelvic lymph nodes were included. VMAT plans were generated with standard clinical PTV margins. Additionally to the planning MR, patients had three MRI scans during treatment to simulate an MRgART. A reference plan with PTV margins determined for MRgART was created per patient and adapted to each of the following MRs. Adapted plans were warped to the planning MR for dose accumulation. The standard plan was rigidly registered to each adaptation MR before it was warped to the planning MR for dose accumulation. Dosimetric impact was compared by DVH analysis and potential clinical effects were assessed by NTCP modeling. RESULTS: MRgART yielded statistically significant lower doses for the bladder wall, rectum and peritoneal cavity, compared to the standard RT, which translated into reduced median risks of urine incontinence (ΔNTCP 2.8%), urine voiding pain (ΔNTCP 2.8%) and acute gastrointestinal toxicity (ΔNTCP 17.4%). Mean population accumulated doses were as good or better for all investigated OAR when planned for MRgART as standard RT. CONCLUSION: Online adapted radiotherapy may reduce the dose to organs at risk in high-risk prostate cancer patients, due to reduced PTV margins. This potentially translates to significant reductions in the risks of acute and late adverse effects.


Asunto(s)
Neoplasias de la Próstata , Radioterapia Guiada por Imagen , Radioterapia de Intensidad Modulada , Humanos , Masculino , Órganos en Riesgo , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen/efectos adversos , Radioterapia de Intensidad Modulada/efectos adversos
8.
Radiother Oncol ; 160: 40-46, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33848564

RESUMEN

BACKGROUND AND PURPOSE: Tumour growth during radiotherapy may lead to geographical misses of the target volume. This study investigates the evolution of the tumour extent and evaluates the need for plan adaptation to ensure dose coverage of the target in glioblastoma patients. MATERIALS AND METHODS: The prospective study included 29 patients referred for 59.4 Gy in 33 fractions. Magnetic resonance imaging (MRI) was performed at the time of treatment planning, at fraction 10, 20, 30, and three weeks after the end of radiotherapy. The gross tumour volume (GTV) was defined as the T1w contrast-enhanced region plus the surgical cavity on each MRI set. The relative GTV volume and the maximum distance (Dmax) of the extent of the actual GTV outside the original GTV were measured. Based on the location of the actual GTV during radiotherapy and the original planned dose, a prospective clinical decision was made whether to adapt the treatment. RESULTS: Dose coverage of the GTV during radiotherapy was not compromised, and none of the radiotherapy plans was adapted. The median Dmax (range) was 5.7 (2.0-18.9) mm, 8.0 (2.0-27.4) mm, 8.0 (1.9-27.3) mm, and 8.9 (1.9-34.4) mm at fraction 10, 20, 30, and follow-up. The relative GTV volume and Dmax observed at fraction 10 were correlated with the values observed at follow-up (R = 0.74, p < 0.001 and R = 0.79, p < 0.001, respectively). CONCLUSION: Large variations in the GTV extent were observed, and changes often occurred early in the treatment. Plan adaptation for geographical misses was not performed in our cohort due to sufficient CTV margins.


Asunto(s)
Glioblastoma , Radioterapia Conformacional , Glioblastoma/diagnóstico por imagen , Glioblastoma/radioterapia , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Carga Tumoral
9.
Front Oncol ; 11: 637591, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33718230

RESUMEN

Radiotherapy has an important role in the curative and palliative treatment settings for bladder cancer. As a target for radiotherapy the bladder presents a number of technical challenges. These include poor tumor visualization and the variability in bladder size and position both between and during treatment delivery. Evidence favors the use of magnetic resonance imaging (MRI) as an important means of tumor visualization and local staging. The availability of hybrid systems incorporating both MRI scanning capabilities with the linear accelerator (MR-Linac) offers opportunity for in-room and real-time MRI scanning with ability of plan adaption at each fraction while the patient is on the treatment couch. This has a number of potential advantages for bladder cancer patients. In this article, we examine the technical challenges of bladder radiotherapy and explore how magnetic resonance (MR) guided radiotherapy (MRgRT) could be leveraged with the aim of improving bladder cancer patient outcomes. However, before routine clinical implementation robust evidence base to establish whether MRgRT translates into improved patient outcomes should be ascertained.

10.
Acta Oncol ; 60(5): 589-597, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33688793

RESUMEN

BACKGROUND AND PURPOSE: Deformable image registration (DIR) and contour propagation are used in daily online adaptation for hybrid MRI linac (MRL) treatments. The accuracy of the propagated contours may vary depending on the chosen workflow (WF), affecting the amount of required manual corrections. This study investigated the impact of three different WFs of contour propagations produced by a clinical treatment planning system for a high-field MRL on head and neck cancer patients. METHODS: Seventeen patients referred for curative radiotherapy for oropharyngeal cancer underwent standard CT-based dose planning and MR scans in the treatment position for planning (pMR), and at the 10th (MR10), 20th (MR20) and 30th (MR30) fraction (±2). The primary tumour, a metastatic lymph node and 8 organs at risk were manually delineated on each set of T2 weighted images. Delineations were repeated one month later on the pMR by the same observer to determine the intra-observer variation (IOV). Three WFs were used to deform images in the treatment planning system for the high-field MRL: In WF1, only the planning image and contours were used as a reference for DIR and propagation to MR10,20,30. The most recently acquired image set prior to the daily images was deformed and uncorrected (WF2) versus manually corrected (WF3) structures propagated to the session image. Dice similarity coefficient (DSC), mean surface distance (MSD) and Hausdorff distance (HD) were calculated for each structure in each model. RESULTS: Population median DSC, MSD and HD for WF1 and WF3 were similar and slightly better than for WF2. WF3 provided higher accuracy than WF1 for structures that are likely to shrink. All DIR workflows were less accurate than the IOV. CONCLUSIONS: WF1 and WF3 provide higher accuracy in structure propagation than WF2. Manual revision and correction of propagated structures are required for all evaluated workflows.


Asunto(s)
Neoplasias de Cabeza y Cuello , Radioterapia Guiada por Imagen , Algoritmos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Interpretación de Imagen Radiográfica Asistida por Computador , Planificación de la Radioterapia Asistida por Computador
11.
Phys Med Biol ; 66(4): 045034, 2021 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-33321475

RESUMEN

The clinical introduction of hybrid magnetic resonance (MR) guided radiotherapy (RT) delivery systems has led to the need to validate the end-to-end dose delivery performance on such machines. In the current study, an MR visible phantom was developed and used to test the spatial deviation between planned and delivered dose at two 1.5 T MR linear accelerator (MR linac) systems, including pre-treatment imaging, dose planning, online imaging, image registration, plan adaptation, and dose delivery. The phantom consisted of 3D printed plastic and MR visible silicone rubber. It was designed to minimise air gaps close to the radiochromic film used as a dosimeter. Furthermore, the phantom was designed to allow submillimetre, reproducible positioning of the film in the phantom. At both MR linac systems, 54 complete adaptive, MR guided RT workflow sessions were performed. To test the dose delivery performance of the MR linac systems in various adaptive RT (ART) scenarios, the sessions comprised a range of systematic positional shifts of the phantom and imaging or plan adaptation conditions. In each workflow session, the positional translation between the film and the adaptive planned dose was determined. The results showed that the accuracy of the MR linac systems was between 0.1 and 0.9 mm depending on direction. The highest mean deviance observed was in the posterior-anterior direction, and the direction of the error was consistent between centres. The precision of the systems was related to whether the workflow utilized the internal image registration algorithm of the MR linac. Workflows using the internal registration algorithm led to a worse precision (0.2-0.7 mm) compared to workflows where the algorithm was decoupled (0.2 mm). In summary, the spatial deviation between planned and delivered dose of MR-guided ART at the two MR linac systems was well below 1 mm and thus acceptable for clinical use.


Asunto(s)
Imagen por Resonancia Magnética , Aceleradores de Partículas , Dosis de Radiación , Radioterapia Guiada por Imagen/instrumentación , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Flujo de Trabajo
12.
Radiat Oncol ; 15(1): 32, 2020 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-32033574

RESUMEN

BACKGROUND: In this study we have evaluated the accuracy of automatic, deformable structure propagation from planning CT and MR scans for daily online plan adaptation for MR linac (MRL) treatment, which is an important element to minimize re-planning time and reduce the risk of misrepresenting the target due to this time pressure. METHODS: For 12 high-risk prostate cancer patients treated to the prostate and pelvic lymph nodes, target structures and organs at risk were delineated on both planning MR and CT scans and propagated using deformable registration to three T2 weighted MR scans acquired during the treatment course. Generated structures were evaluated against manual delineations on the repeated scans using intra-observer variation obtained on the planning MR as ground truth. RESULTS: MR-to-MR propagated structures had significant less median surface distance and larger Dice similarity index compared to CT-MR propagation. The MR-MR propagation uncertainty was similar in magnitude to the intra-observer variation. Visual inspection of the deformed structures revealed that small anatomical differences between organs in source and destination image sets were generally well accounted for while large differences were not. CONCLUSION: Both CT and MR based propagations require manual editing, but the current results show that MR-to-MR propagated structures require fewer corrections for high risk prostate cancer patients treated at a high-field MRL.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Órganos en Riesgo/efectos de la radiación , Fantasmas de Imagen , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Masculino , Variaciones Dependientes del Observador , Pelvis/efectos de la radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
13.
Phys Imaging Radiat Oncol ; 15: 100-104, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33458333

RESUMEN

Magnetic resonance imaging (MRI) has exquisite soft-tissue contrast and is the foundation for image guided radiotherapy (IGRT) with integrated magnetic resonance linacs. However, MRI suffers from geometrical distortions. In this study the MRI system- and patient-induced geometric distortion at four different tumor-sites was investigated: adrenal gland (7 patients), liver (4 patients), pancreas (6 patients), prostate (20 patients). Maximum level of total distortion within the gross-tumor-volume (GTV) was 0.96 mm with no significant difference between abdominal patients (adrenal gland, liver, pancreas) and pelvic patients (prostate). Total tumor-site specific distortion depended on location in the field-of-view and increased with the distance to MRI iso-center.

14.
Acta Oncol ; 58(10): 1352-1357, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31241387

RESUMEN

Purpose: A 1.5 T MR Linac (MRL) has recently become available. MRL treatment workflows (WF) include online plan adaptation based on daily MR images (MRI). This study reports initial clinical experiences after five months of use in terms of patient compliance, cases, WF timings, and dosimetric accuracy. Method and materials: Two different WF were used dependent on the clinical situation of the day; Adapt To Position WF (ATP) where the reference plan position is adjusted rigidly to match the position of the targets and the OARs, and Adapt To Shape WF (ATS), where a new plan is created to match the anatomy of the day, using deformable image registration. Both WFs included three 3D MRI scans for plan adaptation, verification before beam on, and validation during IMRT delivery. Patient compliance and WF timings were recorded. Accuracy in dose delivery was assessed using a cylindrical diode phantom. Results: Nineteen patients have completed their treatment receiving a total of 176 fractions. Cases vary from prostate treatments (60Gy/20F) to SBRT treatments of lymph nodes (45 Gy/3F) and castration by ovarian irradiation (15 Gy/3F). The median session time (patient in to patient out) for 127 ATPs was 26 (21-78) min, four fractions lasted more than 45 min due to additional plan adaptation. For the 49 ATSs a median time of 12 (1-24) min was used for contouring resulting in a total median session time of 42 (29-91) min. Three SBRT fractions lasted more than an hour. The time on the MRL couch was well tolerated by the patients. The median gamma pass rate (2 mm,2% global max) for the adapted plans was 99.2 (93.4-100)%, showing good agreement between planned and delivered dose. Conclusion: MRL treatments, including daily MRIs, plan adaptation, and accurate dose delivery, are possible within a clinically acceptable timeframe and well tolerated by the patients.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Aceleradores de Partículas , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Castración/instrumentación , Castración/métodos , Estudios de Cohortes , Estudios de Factibilidad , Femenino , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/efectos de la radiación , Metástasis Linfática/diagnóstico por imagen , Metástasis Linfática/radioterapia , Imagen por Resonancia Magnética/instrumentación , Masculino , Persona de Mediana Edad , Ovario/diagnóstico por imagen , Ovario/efectos de la radiación , Cooperación del Paciente/estadística & datos numéricos , Fantasmas de Imagen , Próstata/diagnóstico por imagen , Próstata/efectos de la radiación , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Radiometría , Radiocirugia/instrumentación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Factores de Tiempo , Resultado del Tratamiento
15.
Artículo en Inglés | MEDLINE | ID: mdl-32095592

RESUMEN

BACKGROUND AND PURPOSE: Overall treatment time (OTT) is essential for local tumour control and survival in radiotherapy of head and neck cancer (HNC). National radiotherapy guidelines of the Danish Head and Neck Cancer Group (DAHANCA) recommend a maximum OTT of 41 days for moderately accelerated radiation treatment (6 fractions/week) and 48 days for conventional treatment (5 fractions/week). The purpose of this study was to evaluate the effect of surveillance of the radiotherapy course length and treatment gaps in HNC patients to reduce OTT. METHODS: The study included 2011 patients with HNC undergoing radical radiation treatment with 66-68 Gy in 33-34 fractions in 2003-2017 at Odense University Hospital. In February 2016, a systematic weekly review by two radiation therapists of all planned treatment courses was introduced to check OTT of individual patients to portend likely breaks or treatment prolongations. Schedules that violated the OTT guidelines were conferred with the responsible radiation oncologist, and treatment rescheduled by treating twice daily to catch up with a delay. RESULTS: The mean length of accelerated treatment courses was reduced from a maximum of 40.9 days in 2007 to 38.3 days in 2017 and from 50.3 days to 45.9 days for conventional courses. The percentage of individual treatment courses that violated the recommended OTT was reduced to 3% of the accelerated treatments and 13% for the conventional treatments. CONCLUSION: Continuous surveillance of treatment schedules of HNC patients by a brief weekly survey reduced treatment course duration to an extent that was radiobiologically and clinically meaningful.

16.
Phys Imaging Radiat Oncol ; 7: 1-8, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33458398

RESUMEN

BACKGROUND AND PURPOSE: Daily radiotherapy plan adaptation facilitated by a high field magnetic resonance linac (MRL) may potentially reduce the treated volume due to a reduction of the setup uncertainty. However, the technology also imposes limitations to the treatment technique compared to a standard linac. This study investigated the clinical quality of MRL treatment plans against current standard plans using identical planning target volume margins for high-risk prostate cancer patients. MATERIALS AND METHODS: Twenty consecutive patients planned with our current clinical standard TPS and treated with single arc VMAT on standard linacs with 78 Gy in the prostate and 56 Gy for pelvic lymph nodes over 39 fractions were included. In addition, IMRT treatment plans for delivery by a 1.5 T MRL, using standard margins and dose objectives, were made in a dedicated TPS. Mean population dose volume histograms (DVH) and dose metrics were analyzed and clinical plan quality was evaluated by an oncologist. RESULTS: All MRL plans were considered clinically acceptable, and DVH analysis showed an overall high similarity to dose distributions of the clinically delivered plans. Mean target coverage was similar (78.0 Gy vs 77.8 Gy). Small but statistically significant differences were seen in doses to organs at risk; on average MRL plans reduced dose to the bladder (46.2 vs 48.3 Gy) compared to standard plans, while dose was higher to the bowel (29.2 vs 26.6 Gy) and penile bulb (16.5 vs 10.8 Gy). CONCLUSION: MRL treatment plans were clinically acceptable and similar in quality to the current standard.

17.
Radiother Oncol ; 126(1): 43-47, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28987748

RESUMEN

BACKGROUND AND PURPOSE: Defining margins around the Gross Tumour Volume (GTV) to create a Clinical Target Volume (CTV) for head and neck cancer radiotherapy has traditionally been based on presumed knowledge of anatomical routes of spread. However, using a concentric geometric expansion around the GTV may be more reproducible. The purpose of this study was to analyse the inter-observer consistency of geometric CTV delineation with adaptation for anatomical boundaries versus anatomically defined CTVs. MATERIAL AND METHODS: Radiation oncologists at four Danish cancer centres delineated high, intermediate and elective dose CTVs (CTV1, CTV2 and CTV3, respectively) in a patient-case template (stage IV squamous cell carcinoma of the oropharynx), first using mainly anatomical margins (original standard) and then using concentric geometric expansion (new standard). Each centre made a dummy-run radiotherapy plan based on the delineated CTVs. The difference between the CTV contours and the radiotherapy plans was evaluated across the centres. RESULTS: Anatomy-based contours were significantly more heterogenous and showed larger volume differences between centres than geometric margins. Dice similarity coefficient increased by 0.29 and mean surface distance decreased by 4mm for CTV1. Use of consistent CTV volumes resulted in more consistent irradiated volumes between centres. CONCLUSION: Introduction of geometric margins resulted in more uniform CTV1 and CTV2 delineation. Geometric CTV expansion was easier, left less room for misinterpretation, and resulted in more uniform treatment plans with similar irradiated high and intermediate dose volumes across all centres.


Asunto(s)
Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Carcinoma de Células Escamosas/patología , Relación Dosis-Respuesta en la Radiación , Neoplasias de Cabeza y Cuello/patología , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Neoplasias Orofaríngeas/patología , Neoplasias Orofaríngeas/radioterapia , Carcinoma de Células Escamosas de Cabeza y Cuello
18.
Acta Oncol ; 56(11): 1495-1500, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28840767

RESUMEN

BACKGROUND: The quality of radiotherapy planning has improved substantially in the last decade with the introduction of intensity modulated radiotherapy. The purpose of this study was to analyze the plan quality and efficacy of automatically (AU) generated VMAT plans for inoperable esophageal cancer patients. MATERIAL AND METHODS: Thirty-two consecutive inoperable patients with esophageal cancer originally treated with manually (MA) generated volumetric modulated arc therapy (VMAT) plans were retrospectively replanned using an auto-planning engine. All plans were optimized with one full 6MV VMAT arc giving 60 Gy to the primary target and 50 Gy to the elective target. The planning techniques were blinded before clinical evaluation by three specialized oncologists. To supplement the clinical evaluation, the optimization time for the AU plan was recorded along with DVH parameters for all plans. RESULTS: Upon clinical evaluation, the AU plan was preferred for 31/32 patients, and for one patient, there was no difference in the plans. In terms of DVH parameters, similar target coverage was obtained between the two planning methods. The mean dose for the spinal cord increased by 1.8 Gy using AU (p = .002), whereas the mean lung dose decreased by 1.9 Gy (p < .001). The AU plans were more modulated as seen by the increase of 12% in mean MUs (p = .001). The median optimization time for AU plans was 117 min. CONCLUSIONS: The AU plans were in general preferred and showed a lower mean dose to the lungs. The automation of the planning process generated esophageal cancer treatment plans quickly and with high quality.


Asunto(s)
Neoplasias Esofágicas/radioterapia , Órganos en Riesgo/efectos de la radiación , Garantía de la Calidad de Atención de Salud , Planificación de la Radioterapia Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/métodos , Adenocarcinoma/patología , Adenocarcinoma/radioterapia , Anciano , Anciano de 80 o más Años , Algoritmos , Automatización , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/radioterapia , Neoplasias Esofágicas/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosificación Radioterapéutica , Estudios Retrospectivos
19.
Acta Oncol ; 56(6): 874-878, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28464749

RESUMEN

BACKGROUND: Delineation accuracy of the gross tumor volume (GTV) in radiotherapy planning for head and neck (H&N) cancer is affected by computed tomography (CT) artifacts from metal implants which obscure identification of tumor as well as organs at risk (OAR). This study investigates the impact of metal artifact reduction (MAR) in H&N patients in terms of delineation consistency and dose calculation precision in radiation treatment planning. MATERIAL AND METHODS: Tumor and OAR delineations were evaluated in planning CT scans of eleven oropharynx patients with streaking artifacts in the tumor region preceding curative radiotherapy (RT). The GTV-tumor (GTV-T), GTV-node and parotid glands were contoured by four independent observers on standard CT images and MAR images. Dose calculation was evaluated on thirty H&N patients with dental implants near the treated volume. For each patient, the dose derived from the clinical treatment plan using the standard image set was compared with the recalculated dose on the MAR image dataset. RESULTS: Reduction of metal artifacts resulted in larger volumes of all delineated structures compared to standard reconstruction. The GTV-T and the parotids were on average 22% (p < 0.06) and 7% larger (p = 0.005), respectively, in the MAR image plan compared to the standard image plan. Dice index showed reduced inter-observer variations after reduction of metal artifacts for all structures. The average surface distance between contours of different observers improved using the MAR images for GTV and parotids (p = 0.04 and p = 0.01). The median volume receiving a dose difference larger than ±3% was 2.3 cm3 (range 0-32 cm3). CONCLUSIONS: Delineation of structures in the head and neck were affected by metal artifacts and volumes were generally larger and more consistent after reduction of metal artifacts, however, only small changes were observed in the dose calculations.


Asunto(s)
Artefactos , Neoplasias de Cabeza y Cuello/radioterapia , Procesamiento de Imagen Asistido por Computador/métodos , Metales , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
20.
Strahlenther Onkol ; 192(8): 545-51, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27323754

RESUMEN

BACKGROUND: Clinical application of deformable registration (DIR) of medical images remains limited due to sparse validation of DIR methods in specific situations, e. g. in case of cancer recurrences. In this study the accuracy of DIR for registration of planning CT (pCT) and recurrence CT (rCT) images of head and neck squamous cell carcinoma (HNSCC) patients was evaluated. PATIENTS AND MATERIALS: Twenty patients treated with definitive IMRT for HNSCC in 2010-2012 were included. For each patient, a pCT and an rCT scan were used. Median interval between the scans was 8.5 months. One observer manually contoured eight anatomical regions-of-interest (ROI) twice on pCT and once on rCT. METHODS: pCT and rCT images were deformably registered using the open source software elastix. Mean surface distance (MSD) and Dice similarity coefficient (DSC) between contours were used for validation of DIR. A measure for delineation uncertainty was estimated by assessing MSD from the re-delineations of the same ROI on pCT. DIR and manual contouring uncertainties were correlated with tissue volume and rigidity. RESULTS: MSD varied 1-3 mm for different ROIs for DIR and 1-1.5 mm for re-delineated ROIs performed on pCT. DSC for DIR varied between 0.58 and 0.79 for soft tissues and was 0.79 or higher for bony structures, and correlated with the volumes of ROIs (r = 0.5, p < 0.001) and tissue rigidity (r = 0.54, p < 0.001). CONCLUSION: DIR using elastix in HNSCC on planning and recurrence CT scans is feasible; an uncertainty of the method is close to the voxel size length of the planning CT images.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Técnica de Sustracción , Tomografía Computarizada por Rayos X/métodos , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Internet , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiometría/métodos , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Programas Informáticos , Carcinoma de Células Escamosas de Cabeza y Cuello , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA