Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
Am J Cardiol ; 168: 55-63, 2022 04 01.
Article En | MEDLINE | ID: mdl-35058053

We systematically categorized the longer-term (≥3 years) structural and functional characteristics of the ABSORB bioresorbable vascular scaffold (BVS) using optical coherence tomography imaging and coronary vasomotor reactivity testing and further compared the functional characteristics of BVS stented versus remote coronary segments. A total of 92 patients (mean age 56.4 ± 9.7 years, 22.8% women) who underwent percutaneous coronary intervention (76% with acute coronary syndrome) using the ABSORB BVS (112 lesions) were included. Optical coherence tomography analysis (38,790 visible struts) comprised in-segment quantitative lumen/plaque and semiquantitative plaque composition analysis of the neointimal pattern. Epicardial endothelium-dependent and-independent vasomotion was defined as any vasodilatation at low/intermediate intracoronary dose of acetylcholine (ACh) and nitroglycerine, assessed using quantitative coronary angiography. At a median time of 3.2 years follow-up, 79.8% of BVS segments still demonstrated visible struts with a predominant neointimal fibrotic healing pattern in 84% of BVS segments, with 99.5% of struts demonstrating coverage with apposition. Compared with remote segments, BVS segments demonstrated less endothelium-dependent vasodilatation at low (p = 0.06) and intermediate ACh doses (p = 0.04). Hypertension, longer time interval from index percutaneous coronary intervention, and the degree of in-BVS segment neointimal volume (p <0.03 for all) were each independently associated with abnormal BVS endothelium-dependent vasomotor function. Endothelium-independent function was more likely preserved in non-BVS (remote) segments compared with BVS segments (p = 0.06). In conclusion, at 3+ years post-ABSORB BVS insertion, the rate of complete scaffold resorption was low and residual strut presence was high, with a dominant fibrous healing response contributing toward neointimal hyperplasia and endothelium-dependent and-independent vasomotor dysfunction.


Drug-Eluting Stents , Percutaneous Coronary Intervention , Absorbable Implants , Aged , Coronary Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Coronary Vessels/surgery , Female , Humans , Male , Middle Aged , Neointima/pathology , Prosthesis Design , Tomography, Optical Coherence , Treatment Outcome
2.
J Cardiovasc Comput Tomogr ; 3(1): 24-31, 2009.
Article En | MEDLINE | ID: mdl-19201374

BACKGROUND: Multidetector computed tomography (MDCT) has recently emerged as a potential noninvasive alternative for high-resolution imaging of coronary arteries. OBJECTIVE: In this study, we evaluated 64-slice MDCT for detection, quantification, and characterization of atherosclerotic plaque burden in nonculprit lesions. METHODS: Data from 11 patients who underwent both MDCT and intravascular ultrasound (IVUS) for suspected coronary artery disease were collected, and a total of 17 coronary segments and 122 cross-sectional slices were analyzed by MDCT and IVUS. Coronary segments on MDCT were coregistered to IVUS, and each obtained slice was scored by 2 blinded observers for presence and type of plaque. Quantitative measurements included cross-sectional vessel area, lumen area, wall area, plaque volume, and plaque burden. Mean and standard deviation of Hounsfield units (HUs) were recorded for plaque when present. RESULTS: Overall sensitivity for plaque detection was 95.0%, and specificity, positive predictive value, negative predictive value were 88.7%, 89.1%, and 94.8%, respectively. Spearman's correlation coefficients were 0.85, 0.75, 0.70, 0.89, and 0.54 for cross-sectional vessel area, lumen area, wall area, plaque volume, and plaque burden, respectively. The interobserver variability for plaque burden and plaque volume measurements between readers on 64-MDCT was high at 32.7% and 30.4%, respectively. Combined noncalcified plaque had a mean MDCT density significantly different from that of calcified plaque. Soft and fibrous plaques were not able to be distinguished based on their HU values. CONCLUSION: Sixty-four-slice MDCT had good correlation with IVUS but with high interobserver variability. Plaque characterization remains a challenge with present MDCT technology.


Carotid Stenosis/diagnostic imaging , Coronary Angiography/methods , Echocardiography/methods , Tomography, X-Ray Computed/methods , Humans , Reproducibility of Results , Sensitivity and Specificity
...