Anal Chem ; 83(7): 2532-8, 2011 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-21355541

RESUMEN

For many applications there is a requirement for nondestructive analytical investigation of the elemental distribution in a sample. With the improvement of X-ray optics and spectroscopic X-ray imagers, full field X-ray fluorescence (FF-XRF) methods are feasible. A new device for high-resolution X-ray imaging, an energy and spatial resolving X-ray camera, is presented. The basic idea behind this so-called "color X-ray camera" (CXC) is to combine an energy dispersive array detector for X-rays, in this case a pnCCD, with polycapillary optics. Imaging is achieved using multiframe recording of the energy and the point of impact of single photons. The camera was tested using a laboratory 30 µm microfocus X-ray tube and synchrotron radiation from BESSY II at the BAMline facility. These experiments demonstrate the suitability of the camera for X-ray fluorescence analytics. The camera simultaneously records 69,696 spectra with an energy resolution of 152 eV for manganese K(α) with a spatial resolution of 50 µm over an imaging area of 12.7 × 12.7 mm(2). It is sensitive to photons in the energy region between 3 and 40 keV, limited by a 50 µm beryllium window, and the sensitive thickness of 450 µm of the chip. Online preview of the sample is possible as the software updates the sums of the counts for certain energy channel ranges during the measurement and displays 2-D false-color maps as well as spectra of selected regions. The complete data cube of 264 × 264 spectra is saved for further qualitative and quantitative processing.

2.
J Synchrotron Radiat ; 14(Pt 4): 326-30, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17587657

RESUMEN

A two-step focusing set-up combining a Fresnel zone plate with an ellipsoidal capillary is presented. It is shown that, in addition to the anticipated gain in flux, the employment of the prefocusing micro-optic makes optimal use of the elliptical shape of the capillary by almost eliminating aberrations. A small cross section of the prefocused beam allows a tiny fraction of the capillary surface to be selected, thus reducing the influence of slope errors. An X-ray beam with a 15 keV energy was focused down to a spot size as small as 250 nm, demonstrating the best value that has been achieved up to now for single-bounce capillaries. The use of an ellipsoidal capillary as a micromirror under off-axis illumination by microfocusing optics may open up new opportunities in nanofocusing developments.

3.
J Synchrotron Radiat ; 14(Pt 2): 227-8, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17317925

RESUMEN

A single-bounce capillary with an ellipsoidal shape has been used for two-step focusing in combination with a Fresnel zone plate (FZP). The FZP serves as a first microfocusing element and produces a demagnified micrometer image of the source, before the elliptical capillary makes a last final compression of the beam. With 15 keV X-rays from the European Synchrotron Radiation Facility BM5 bending magnet, the two-step demagnification system produced a focus of about 250 nm with a gain of more than 1000. The use of an ellipsoidal capillary as a micro-mirror under off-axis illumination using micro-prefocusing optics might open up new opportunities in nanofocusing developments.

4.
Opt Express ; 14(10): 4570-6, 2006 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-19516609

RESUMEN

Thin films of highly oriented pyrolytic graphite (HOPG) give the opportunity to realize crystal optics with arbitrary geometry by mounting it on a mould of any shape. A specific feature of HOPG is its mosaicity accompanied by a high integral reflectivity, which is by an order of magnitude higher than that of all other known crystals in an energy range between 2 keV up to several 10 keV. These characteristics make it possible to realize highly efficient collecting optics, which could be also relevant for compact x-ray diagnostic tools and spectrometers. For these applications the achievable spectral resolution of the crystal optics is of interest. In this article measurements with a spectral resolution of E/DeltaE=2900 in the second order reflection and E/DeltaE=1800 in the first order reflection obtained with HOPG crystals are presented. These are by far the highest spectral resolutions reported for HOPG crystals. The integral reflectivity of these very thin films is still comparable with that of ideal Ge crystals. The trade-off between energy resolution and high integral reflectivity for HOPG is demonstrated by determining these parameters for HOPG films of different thickness.

5.
Eur Radiol ; 14(9): 1641-6, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15232713

RESUMEN

X-ray spectra are composed of a broad bremsspectrum and anode-characteristic emission lines. In mammography typically molybdenum (Mo), rhodium (Rh) or tungsten (W) anodes are used in combination with Mo, Rh or aluminium filters. Only the photons with energies between 17 and 22 keV of the resulting spectrum are suitable for the soft tissue imaging needed for mammography. The aim of this article is to present first results obtained with a monochromator module mounted at the exit of the X-ray tube of a conventional clinical mammography unit. The experimental setup consists of a Siemens Mammomat 300, an X-ray monochromator module and a linear array detector for image acquisition. The technique is similar to the slot-scan technique known from digital mammography. The experimental machine allows to obtain images both with polychromatic and monochromatic X-rays. Initial evaluation of the system was performed by examination of a contrast-detail phantom (CD-MAM-phantom, Nijmegen, The Netherlands). Images done with the new monochromatic technique were compared to images of the phantom done with polychromatic spectra, with film-screen mammography as well as with digital mammography. The new technique with monochromatic slot-scan mammography resulted in correct identification of 93% of the phantom. Digital slot-scan mammography with polychromatic beam resulted in correct identification of 87%, digital full-field mammography in 83% and conventional film-screen mammography in 70% of the phantom. The results suggest that monochromatization has a potential for improving image quality or decreasing dose in X-ray mammography.


Asunto(s)
Mamografía/instrumentación , Intensificación de Imagen Radiográfica/instrumentación , Diseño de Equipo , Femenino , Humanos , Fantasmas de Imagen , Sensibilidad y Especificidad , Tecnología Radiológica , Pantallas Intensificadoras de Rayos X
6.
Fresenius J Anal Chem ; 371(3): 307-16, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11688642

RESUMEN

A newly developed spectrometer for energy-dispersive micro X-ray fluorescence spectrometry has been designed for the demands of archaeometry. ArtTAX combines the advantages of non-destructive and sensitive multi-elemental analysis at sub-mm resolution with the possibility of working outside the laboratory. The spectrometer consists of an air-cooled, low-power molybdenum tube, new generation polycapillary X-ray optics, a silicon drift detector without the need for liquid-nitrogen cooling, a CCD camera, and three light diodes for sample positioning. The motor-driven measurement head is fixed on a x,y,z-flexible tripod support which can be assembled and dismantled within minutes. The spot size of the primary X-ray beam was determined to be 94 microm for the Cu(Kalpha) energy, the detection limits are in a range of a few tens of microg g(-1) for the medium energy-range in glass. Additional open helium purging in the excitation and detection paths enables the determination of elements down to sodium, thus avoiding vacuum conditions or a size-limiting sample chamber. A selection of qualitative and quantitative results on pigment, metal, glass, and enamel analyses are presented to show the potential of ArtTAX in the field of art and archaeology.