Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 8 de 8
1.
Front Med (Lausanne) ; 9: 840801, 2022.
Article En | MEDLINE | ID: mdl-35308556

Background: Heterogeneous progression of chronic kidney disease (CKD) toward dialysis advocates improving in renal care management. Diagnosis and staging of CKD relies on estimated glomerular filtration rate (eGFR) and albuminuria. Tubular biomarkers emerged as new predictors of worsening renal function (WRF), due to partial inaccuracy of eGFR and existing WRF in non-proteinuric patients. Active vitamin D is synthesized in renal tubules and participates to mineral adaptation in CKD. Circulating 1,25-dihydroxyvitamin D [1,25(OH)2D] was poorly investigated as a biomarker of endocrine tubular function and predictor of WRF. Objective: Investigate capability of 1,25(OH)2D to predict parathormone (PTH) increase and WRF in CKD stage 3-4. Methods: PASCaL-1,25D was an observational, prospective, monocentric study. Primary outcomes were absolute and 20% increase in PTH, and WRF defined as 20% reduction in eGFR or dialysis initiation at 6 months. Results: Seventy-one patients completed follow up. Absolute increase in PTH (1-84) was independently predicted by lower 1,25(OH)2D levels (p = 0.0134). No association was detected between 1,25(OH)2D and iPTH increase. Higher 1,25(OH)2D was associated with reduced risk of WRF at univariate analysis [OR 0.89 (95% CI 0.86-0.93), p = 0.006]. The 1,25(OH)2D/PTH (1-84) ratio was associated with non-significant 84% risk reduction for WRF [OR 0.16 (95% CI 0.06-0.41), p = 0.05]. Low 1,25(OH)2D reached 100% sensitivity in predicting WRF in CKD stage 3 (AUC 9.909, p < 0.0001) and non-elderly patients (AUC 0.883, p < 0.0001). Machine learning models retained 1,25(OH)2D/PTH (1-84) as relevant predictor of WRF together with eGFR and albuminuria. Age influenced interaction between renal and mineral biomarkers. Conclusion: 1,25(OH)2D deserves attention as biomarker of tubular health, and sensible predictor of WRF on the short run among non-elderly patients affected by stage 3 CKD. The 1,25(OH)2D/PTH (1-84) ratio may represent a composite biomarker of tubular reserve/endocrine response to the transition from adaptive to maladaptive equilibrium in CKD-MBD.

2.
Clin Chem Lab Med ; 59(8): 1463-1467, 2021 07 27.
Article En | MEDLINE | ID: mdl-33711225

OBJECTIVES: COVID-19 has brought about tests from many manufacturers. While molecular and rapid antigen tests are targeted for early diagnosis, immunoassays have a larger role in epidemiological studies, understanding longitudinal immunity, and in vaccine development and response. METHODS: The performance of the LIAISON® SARS-CoV-2 TrimericS IgG assay was evaluated against the Beckman ACCESS SARS-CoV-2 IgG assay in New Mexico, and against the Siemens ADVIA Centaur COV2G assay in New York. Discordant samples were parsed using a microneutralization assay. RESULTS: A SARS-CoV-2 antibody positivity rate of 23.8% was observed in the samples tested in New York (September 2020), while in the same month the positivity rate was 1.5% in New Mexico. Positive and negative agreement were 67.6% (95% CI 49.5-82.6%) and 99.8% (95% CI 99.5-99.9%), respectively, with the Beckman test, and 98.0% (95% CI 95.7-99.3%) and 94.8% (95% CI 93.4-96.0%), respectively, with the Siemens test. Receiver operating characteristic analysis for the detection of SARS-CoV-2 antibodies discloses an AUC, area under the curve, of 0.996 (95% CI 0.992-0.999) for the LIAISON® SARS-CoV-2 TrimericS IgG assay. The criterion associated to the Youden Index was determined to be >12.9 kAU/L with a sensitivity of 99.44% and a specificity of 99.82%. CONCLUSIONS: The LIAISON® SARS-CoV-2 TrimericS IgG assay is highly sensitive and specific. The balance of these parameters, without emphasis on high specificity alone, is particularly important when applied to high prevalence populations, where a highly sensitive assay will result in reporting a lower number of false negative subjects.


Antibodies, Viral/blood , COVID-19/diagnosis , Immunoassay/methods , Immunoglobulin G/blood , SARS-CoV-2/metabolism , Spike Glycoprotein, Coronavirus/immunology , Area Under Curve , Automation , COVID-19/virology , Humans , ROC Curve , Reagent Kits, Diagnostic , SARS-CoV-2/isolation & purification , Sensitivity and Specificity
3.
J Clin Gastroenterol ; 55(3): 239-243, 2021 03 01.
Article En | MEDLINE | ID: mdl-32324678

GOAL: The goal of this study was to assess the clinical performance of an investigational in vitro fecal calprotectin immunoassay for differentiating inflammatory bowel disease (IBD) from irritable bowel syndrome (IBS). BACKGROUND: Fecal calprotectin is a stool biomarker that can assist in the detection of intestinal inflammation and is utilized to identify individuals who have a higher chance of having IBD and who require further invasive tests. Current assays exhibit variable performance. MATERIALS AND METHODS: This study was a multicenter, cross-sectional analysis of prospectively collected stool samples from patients 4 years of age or older who presented with gastrointestinal (GI) symptoms and underwent colonoscopy for diagnostic confirmation. IBD was diagnosed based on clinical, endoscopic, and histologic findings. IBS was diagnosed based on Rome III Criteria and negative colonoscopy. Stool samples were extracted and tested on the DiaSorin LIAISON XL using the LIAISON Calprotectin Assay. RESULTS: A total of 240 patients (67% female) were included in the study. In total, 102 patients had IBD (54% ulcerative colitis), 67 had IBS, and 71 had other GI disorders. Median fecal calprotectin levels were significantly higher in patients with IBD [522 µg/g; 95% confidence interval (CI): 354-970 µg/g] compared with IBS (34.5 µg/g; 95% CI: 19.7-44.2 µg/g, P<0.001) and other GI disorders (28.6 µg/g; 95% CI: 18.7-40.3 µg/g, P<0.001). Receiver operating characteristic curve analysis indicated a fecal calprotectin cutoff of 94 µg/g for distinguishing IBD from other GI disorders with an area under the curve of 0.964 (sensitivity=92.2%, specificity=88.4%). CONCLUSION: The automated LIAISON Calprotectin assay brings efficient calprotectin testing to the laboratory with a time to the first result of 35 minutes and is a sensitive marker for distinguishing IBD from IBS with a cutoff of ∼100 µg/g.


Colitis, Ulcerative , Inflammatory Bowel Diseases , Irritable Bowel Syndrome , Biomarkers , Colitis, Ulcerative/diagnosis , Cross-Sectional Studies , Feces , Female , Humans , Inflammatory Bowel Diseases/diagnosis , Irritable Bowel Syndrome/diagnosis , Leukocyte L1 Antigen Complex , Male
4.
J Clin Microbiol ; 58(9)2020 08 24.
Article En | MEDLINE | ID: mdl-32580948

In the coronavirus (CoV) disease 2019 (COVID-19) pandemic, highly selective serological testing is essential to define exposure to severe acute respiratory syndrome CoV 2 (SARS-CoV-2). Many tests have been developed, yet with variable speeds to first results, and are of unknown quality, particularly when considering the prediction of neutralizing capacity. The LIAISON SARS-CoV-2 S1/S2 IgG assay was designed to measure antibodies against the SARS-CoV-2 native S1/S2 proteins in a standardized automated chemiluminescence assay. The clinical and analytical performances of the test were validated in an observational study using residual samples (>1,500) with a positive or negative COVID-19 diagnosis. The LIAISON SARS-CoV-2 S1/S2 IgG assay proved to be highly selective and specific and offered semiquantitative measures of serum or plasma levels of anti-S1/S2 IgG with neutralizing activity. The assay's diagnostic sensitivities were 91.3% and 95.7% at >5 or ≥15 days from diagnosis, respectively, and 100% when assessed against a neutralizing assay. The assay's specificity ranged between 97% and 98.5%. The average imprecision of the assay was a <5% coefficient of variation. Assay performance at 2 different cutoffs was evaluated to optimize predictive values. The automated LIAISON SARS-CoV-2 S1/S2 IgG assay brings efficient, sensitive, specific, and precise serological testing to the laboratory, with the capacity to test large amounts of samples per day; first results are available within 35 min, with a throughput of 170 tests/hour. The semiquantitative results provided by the test also associate with the presence of neutralizing antibodies and may provide a useful tool for the large-scale screening of convalescent-phase plasma for safe therapeutic use.


Antibodies, Viral/blood , Betacoronavirus/immunology , Clinical Laboratory Techniques , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Serologic Tests , Antibodies, Neutralizing/blood , Automation, Laboratory , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques/methods , Clinical Laboratory Techniques/standards , Clinical Laboratory Techniques/statistics & numerical data , Coronavirus Infections/immunology , Humans , Immunoglobulin G/blood , Pandemics , Pneumonia, Viral/immunology , Reproducibility of Results , SARS-CoV-2 , Sensitivity and Specificity , Serologic Tests/methods , Serologic Tests/standards , Serologic Tests/statistics & numerical data , Spike Glycoprotein, Coronavirus/immunology
5.
Biomed Res Int ; 2020: 7189519, 2020.
Article En | MEDLINE | ID: mdl-32280698

BACKGROUND: Antigens derived from Helicobacter pylori can be used as stool biomarkers to assist in the diagnosis of H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian. METHODS: This prospective multisite study enrolled patients undergoing an esophagogastroduodenoscopy with collection of biopsy and stool specimens. Adult patients (≥22 years) participated in the study from February 2017 to August 2018. Specimens of the stomach were tested by three methods, known as the Composite Reference Method: (1) histological evaluation, (2) culture of the organism, and (3) rapid urease detection test. H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian. RESULTS: 277 patients (63% female) were included in the study. The prevalence of infected subjects was 24.2% in this study cohort. Clinical performance assessed against the Composite Reference Method showed very good agreement (Cohen's kappa = 0.922), with good sensitivity (95.5%) and specificity (97.6%). Reproducibility study results showed total imprecision ranging from 3.1% to 13.9% CV. CONCLUSION: The automated LIAISON® Meridian H. pylori SA assay brings reliable noninvasive testing for H. pylori to the laboratory that is in very good agreement with the current, more invasive biopsy-based methods such as histology, culture, or rapid urease test. The clinical trial identifiers are NCT03060746 (pretherapy) and NCT03060733 (posttherapy).H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian.


Antigens, Bacterial/analysis , Feces/microbiology , Helicobacter Infections/immunology , Helicobacter pylori/immunology , Immunoenzyme Techniques/methods , Adult , Aged , Biopsy , Female , Helicobacter Infections/diagnosis , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Urease , Young Adult
6.
Clin Chem Lab Med ; 56(9): 1476-1482, 2018 08 28.
Article En | MEDLINE | ID: mdl-29750642

BACKGROUND: Over the past few decades, parathyroid hormone (PTH) immunoassays have progressed through successive generations resulting in increased specificity and accuracy for detecting circulating PTH. With the introduction of third-generation assays, in which the biologically active PTH(1-84) is specifically targeted, the PTH(7-84) and other fragments are not detected. The specific recognition of only PTH(1-84) whole molecule allows for more reliable standardization and calibration than with the existing assays. METHODS: Samples from patients on hemodialysis or with primary hyperparathyroidism and apparently healthy subjects were examined in different collection matrices (EDTA plasma, unspun EDTA plasma and SST) stored for 0, 24 or 72 h at room temperature to reflect the prevailing sample collection methods, shipping and processing conditions of centralized labs in the United States. Samples were analyzed by the LIAISON 1-84 PTH and N-TACT assays, and by three additional commercially available intact PTH assays. RESULTS: Defined samples, prepared using two different standards (WHO 95/646 international standard and the synthetic Bachem PTH(1-84)), show little bias with the LIAISON 1-84 PTH assay, but not with the other intact PTH assays. Furthermore, PTH is stable for up to 72 h in plasma, but less stable in serum beyond 24 h. CONCLUSIONS: The FDA-approved LIAISON 1-84 PTH assay is accurate and reliably measures the biologically active PTH molecule in plasma or serum stored at room temperature for up 72 and 24 h, respectively.


Immunoassay/methods , Parathyroid Hormone/blood , Humans , Hyperparathyroidism, Primary/pathology , Immunoassay/standards , Parathyroid Hormone/standards , Reagent Kits, Diagnostic , Reference Standards , Renal Insufficiency, Chronic/pathology , Reproducibility of Results , Temperature
7.
Bone ; 111: 36-43, 2018 06.
Article En | MEDLINE | ID: mdl-29550267

Sclerostin is a 190 amino acid protein secreted primarily by osteocytes. It was initially identified due to mutations in the SOST gene associated with high bone mass phenotypes. Much recent work has sought to determine the importance of sclerostin across an array of conditions which affect the human skeleton. However, accurate measurement of sclerostin from serum and plasma sources remains a significant impediment, with currently available commercial assays showing marked differences in measured sclerostin values. Accordingly, sclerostin assay standardization remains an important but unmet need before sclerostin measurements can be used for the clinical management of bone disease. Here we characterize a novel automated chemiluminescent sclerostin assay (LIAISON®, DiaSorin) which overcomes many of these limitations. Important assay characteristics include: a wide dynamic range (50-6500pg/mL); high intra- (<2.5%) and inter- (<5%) assay precision; matched serum and plasma equivalence (<10% difference); specificity for the intact sclerostin molecule; and rapid assay results. Serum sclerostin levels measured with the LIAISON® assay in a population-based sample of adult men (n=278) and women (n=348) demonstrated that sclerostin levels were significantly higher in men as compared to women and were positively associated with age in both sexes, consistent with previously published work. In postmenopausal women, serum sclerostin levels measured with the LIAISON® assay were reduced in response to treatment with either estrogen or teriparatide, again consistent with previous findings. Collectively, the above data demonstrate that the LIAISON® sclerostin assay provides a reliable tool for more confident assessment of emergent mechanisms wherein sclerostin may impact a number of bone related pathologies.


Bone Morphogenetic Proteins/analysis , Bone Morphogenetic Proteins/blood , Luminescent Measurements/methods , Adaptor Proteins, Signal Transducing , Adult , Aged , Aged, 80 and over , Bone Density , Female , Genetic Markers , Humans , Luminescent Measurements/standards , Male , Middle Aged , Osteocytes/cytology , Osteocytes/metabolism , Osteoporosis, Postmenopausal/blood
8.
FASEB J ; 20(13): 2408-10, 2006 Nov.
Article En | MEDLINE | ID: mdl-17023390

While bivalent antibodies can block ligand-receptor interactions, IgM pentamers efficiently cross-link cell surface targets and evoke physiological responses. We have described one such interaction between an IgM antibody (Ab) and the B7-DC costimulatory molecule expressed by dendritic cells that induces strong antitumor immunity and modulates pathogenic responses associated with allergic asthma. Progressive changes in gene expression in dendritic cells activated by an IgM B7-DC cross-linking Ab resulted in the increased expression in 350 genes and decreased expression of more than 200 genes over the course of 24 h following Ab treatment. In particular, up-regulation of the caspase inhibitor FLIP and the chemokine receptor CCR7, and the down-regulation of the CXCR4 receptor provide a mechanistic basis of Ab-induced survival and enhanced migration into draining lymph nodes. Increased expression of both cell surface and secreted molecules known to be mediators of the immunomodulatory properties of dendritic cells was detected at both the levels of RNA and protein expression. This analysis documents the ability of IgM Ab to activate a gene expression cascade leading to important biological changes in cellular function and provides mechanistic insight into the potent immunomodulatory properties attributed to this Ab.


Antibodies/pharmacology , B7-1 Antigen/pharmacology , Dendrites/physiology , Gene Expression Regulation , Immunoglobulin M/immunology , Animals , Bone Marrow Cells/cytology , Bone Marrow Cells/immunology , DNA Primers , Dendrites/drug effects , Dendrites/immunology , Gene Expression Regulation/drug effects , Humans , Mice , Mice, Inbred C57BL , Oligonucleotide Array Sequence Analysis , Programmed Cell Death 1 Ligand 2 Protein , Reverse Transcriptase Polymerase Chain Reaction , Transcription, Genetic
...