Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 10(1): 17986, 2020 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-33093605

RESUMEN

Malignant gliomas are primary brain tumours with an infiltrative growth pattern, often with contrast enhancement on magnetic resonance imaging (MRI). However, it is well known that tumour infiltration extends beyond the visible contrast enhancement. The aim of this study was to investigate if there is contrast enhancement not detected visually in the peritumoral oedema of malignant gliomas by using relaxometry with synthetic MRI. 25 patients who had brain tumours with a radiological appearance of malignant glioma were prospectively included. A quantitative MR-sequence measuring longitudinal relaxation (R1), transverse relaxation (R2) and proton density (PD), was added to the standard MRI protocol before surgery. Five patients were excluded, and in 20 patients, synthetic MR images were created from the quantitative scans. Manual regions of interest (ROIs) outlined the visibly contrast-enhancing border of the tumours and the peritumoral area. Contrast enhancement was quantified by subtraction of native images from post GD-images, creating an R1-difference-map. The quantitative R1-difference-maps showed significant contrast enhancement in the peritumoral area (0.047) compared to normal appearing white matter (0.032), p = 0.048. Relaxometry detects contrast enhancement in the peritumoral area of malignant gliomas. This could represent infiltrative tumour growth.


Asunto(s)
Neoplasias Encefálicas/diagnóstico , Medios de Contraste/metabolismo , Edema/diagnóstico , Glioma/diagnóstico , Imagen por Resonancia Magnética/métodos , Intensificación de Imagen Radiográfica/métodos , Adulto , Anciano , Neoplasias Encefálicas/metabolismo , Edema/metabolismo , Femenino , Glioma/metabolismo , Humanos , Masculino , Persona de Mediana Edad
2.
AJNR Am J Neuroradiol ; 39(12): 2194-2199, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30409854

RESUMEN

BACKGROUND AND PURPOSE: Administration of a gadolinium-based contrast agent is an important diagnostic biomarker for blood-brain barrier damage. In clinical use, detection is based on subjective comparison of native and postgadolinium-based contrast agent T1-weighted images. Quantitative MR imaging studies have suggested a relation between the longitudinal relaxation rate and proton-density in the brain parenchyma, which is disturbed by gadolinium-based contrast agents. This discrepancy can be used to synthesize a contrast-enhancement map based solely on the postgadolinium-based contrast agent acquisition. The aim of this study was to compare synthetic enhancement maps with subtraction maps of native and postgadolinium-based contrast agent images. MATERIALS AND METHODS: For 14 patients with high-grade gliomas, quantitative MR imaging was performed before and after gadolinium-based contrast agent administration. The quantification sequence was multidynamic and multiecho, with a scan time of 6 minutes. The 2 image stacks were coregistered using in-plane transformation. The longitudinal relaxation maps were subtracted and correlated with the synthetic longitudinal relaxation enhancement maps on the basis of the postgadolinium-based contrast agent images only. ROIs were drawn for tumor delineation. RESULTS: Linear regression of the subtraction and synthetic longitudinal relaxation enhancement maps showed a slope of 1.02 ± 0.19 and an intercept of 0.05 ± 0.12. The Pearson correlation coefficient was 0.861 ± 0.059, and the coefficient of variation was 0.18 ± 0.04. On average, a volume of 1.71 ± 1.28 mL of low-intensity enhancement was detected in the synthetic enhancement maps outside the borders of the drawn ROI. CONCLUSIONS: The study shows that there was a good correlation between subtraction longitudinal relaxation enhancement maps and synthetic longitudinal relaxation enhancement maps in patients with high-grade gliomas. The method may improve the sensitivity and objectivity for the detection of gadolinium-based contrast agent enhancement.


Asunto(s)
Mapeo Encefálico/métodos , Neoplasias Encefálicas/diagnóstico por imagen , Glioma/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Anciano , Neoplasias Encefálicas/patología , Medios de Contraste , Femenino , Gadolinio , Glioma/patología , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad
3.
Eur J Neurol ; 24(1): 112-121, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27699930

RESUMEN

BACKGROUND AND PURPOSE: Brain atrophy is related to clinical deterioration in multiple sclerosis (MS) but its association with intrathecal markers of inflammation or neurodegeneration is unclear. Our aim was to investigate whether cerebrospinal fluid (CSF) markers of inflammation or neurodegeneration are associated with brain volume change in natalizumab-treated MS and whether this change is reflected in non-lesional white matter metabolites. METHODS: About 25 patients with natalizumab-treated MS were followed for 3 years with assessment of percentage brain volume change (PBVC) and absolute quantification of metabolites with proton magnetic resonance spectroscopy (1 H MRS). Analyses of inflammatory [interleukin 1ß (IL-1ß), IL-6, C-X-C motif chemokine 8 (CXCL8), CXCL10, CXCL11, C-C motif chemokine 22] and neurodegenerative [neurofilament light protein (NFL), glial fibrillary acidic protein, myelin basic protein, tau proteins] markers were done at baseline and 1-year follow-up. RESULTS: The mean decline in PBVC was 3% at the 3-year follow-up, although mean 1 H MRS metabolite levels in non-lesional white matter were unchanged. CSF levels of NFL and tau at baseline correlated negatively with PBVC over 3 years (r = -0.564, P = 0.012, and r = -0.592, P = 0.010, respectively). CONCLUSIONS: A significant 3-year whole-brain atrophy was not reflected in mean metabolite change of non-lesional white matter. In addition, our results suggest that CSF levels of NFL and tau correlate with brain atrophy development and may be used for evaluating treatment response in inflammatory active MS.


Asunto(s)
Encéfalo/patología , Factores Inmunológicos/uso terapéutico , Filamentos Intermedios , Esclerosis Múltiple/tratamiento farmacológico , Natalizumab/uso terapéutico , Proteínas tau/líquido cefalorraquídeo , Adulto , Atrofia/líquido cefalorraquídeo , Atrofia/diagnóstico por imagen , Atrofia/patología , Axones/patología , Biomarcadores/líquido cefalorraquídeo , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/líquido cefalorraquídeo , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Resultado del Tratamiento , Adulto Joven
4.
AJNR Am J Neuroradiol ; 37(1): 94-100, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26471751

RESUMEN

BACKGROUND AND PURPOSE: Contrast-enhancing MS lesions are important markers of active inflammation in the diagnostic work-up of MS and in disease monitoring with MR imaging. Because intravenous contrast agents involve an expense and a potential risk of adverse events, it would be desirable to identify active lesions without using a contrast agent. The purpose of this study was to evaluate whether pre-contrast injection tissue-relaxation rates and proton density of MS lesions, by using a new quantitative MR imaging sequence, can identify active lesions. MATERIALS AND METHODS: Forty-four patients with a clinical suspicion of MS were studied. MR imaging with a standard clinical MS protocol and a quantitative MR imaging sequence was performed at inclusion (baseline) and after 1 year. ROIs were placed in MS lesions, classified as nonenhancing or enhancing. Longitudinal and transverse relaxation rates, as well as proton density were obtained from the quantitative MR imaging sequence. Statistical analyses of ROI values were performed by using a mixed linear model, logistic regression, and receiver operating characteristic analysis. RESULTS: Enhancing lesions had a significantly (P < .001) higher mean longitudinal relaxation rate (1.22 ± 0.36 versus 0.89 ± 0.24), a higher mean transverse relaxation rate (9.8 ± 2.6 versus 7.4 ± 1.9), and a lower mean proton density (77 ± 11.2 versus 90 ± 8.4) than nonenhancing lesions. An area under the receiver operating characteristic curve value of 0.832 was obtained. CONCLUSIONS: Contrast-enhancing MS lesions often have proton density and relaxation times that differ from those in nonenhancing lesions, with lower proton density and shorter relaxation times in enhancing lesions compared with nonenhancing lesions.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Medios de Contraste/administración & dosificación , Femenino , Estudios de Seguimiento , Gadolinio DTPA/administración & dosificación , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/patología , Esclerosis Múltiple Recurrente-Remitente/diagnóstico , Adulto Joven
5.
Acta Radiol ; 53(10): 1158-63, 2012 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-23024181

RESUMEN

BACKGROUND: Conventional magnetic resonance imaging (MRI) has relatively long scan times for routine examinations, and the signal intensity of the images is related to the specific MR scanner settings. Due to scanner imperfections and automatic optimizations, it is impossible to compare images in terms of absolute image intensity. Synthetic MRI, a method to generate conventional images based on MR quantification, potentially both decreases examination time and enables quantitative measurements. PURPOSE: To evaluate synthetic MRI of the brain in a clinical setting by assessment of the contrast, the contrast-to-noise ratio (CNR), and the diagnostic quality compared with conventional MR images. MATERIAL AND METHODS: Twenty-two patients had synthetic imaging added to their clinical MR examination. In each patient, 12 regions of interest were placed in the brain images to measure contrast and CNR. Furthermore, general image quality, probable diagnosis, and lesion conspicuity were investigated. RESULTS: Synthetic T1-weighted turbo spin echo and T2-weighted turbo spin echo images had higher contrast but also a higher level of noise, resulting in a similar CNR compared with conventional images. Synthetic T2-weighted FLAIR images had lower contrast and a higher level of noise, which led to a lower CNR. Synthetic images were generally assessed to be of inferior image quality, but agreed with the clinical diagnosis to the same extent as the conventional images. Lesion conspicuity was higher in the synthetic T1-weighted images, which also had a better agreement with the clinical diagnoses than the conventional T1-weighted images. CONCLUSION: Synthetic MR can potentially shorten the MR examination time. Even though the image quality is perceived to be inferior, synthetic images agreed with the clinical diagnosis to the same extent as the conventional images in this study.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/patología , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/patología , Humanos , Persona de Mediana Edad , Esclerosis Múltiple/patología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...