Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Nucl Med Biol ; 128-129: 108876, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38241936

RESUMEN

BACKGROUND: The beneficial role of glucose-dependent insulinotropic polypeptide receptor (GIPR) in weight control and maintaining glucose levels has led to the development of several multi-agonistic peptide drug candidates, targeting GIPR and glucagon like peptide 1 receptor (GLP1R) and/or the glucagon receptor (GCGR). The in vivo quantification of target occupancy by these drugs would accelerate the development of new drug candidates. The aim of this study was to evaluate a novel peptide (GIP1234), based on previously reported ligand DOTA-GIP-C803, modified with a fatty acid moiety to prolong its blood circulation. It would allow higher target tissue exposure and consequently improved peptide uptake as well as in vivo PET imaging and quantification of GIPR occupancy by novel drugs of interest. METHOD: A 40 amino acid residue peptide (GIP1234) was synthesized based on DOTA-GIP-C803, in turn based on the sequences of endogenous GIP and Exendin-4 with specific amino acid modifications to obtain GIPR selectivity. A palmitoyl fatty acid chain was furthermore added at Lys14 via a glutamic acid linker to prolong its blood circulation time by the interaction with albumin. GIP1234 was conjugated with a DOTA chelator at the C-terminal cysteine residue to achieve 68Ga radiolabeling. The resulting PET probe, [68Ga]Ga-DOTA-GIP1234 was evaluated for receptor binding specificity and selectivity using HEK293 cells transfected with human GIPR, GLP1R, or GCGR. Blocking experiments with tirzepatide (2 µM) were conducted using huGIPR HEK293 cells to investigate binding specificity. Ex vivo and in vivo organ distribution of [68Ga]Ga-DOTA-GIP1234 was studied in rats and a pig in comparison to [68Ga]Ga-DOTA-C803-GIP. Binding of [68Ga]Ga-DOTA-GIP1234 to albumin was assessed in situ using polyacrylamide gel electrophoresis (PAGE). The stability was tested in formulation buffer and rat blood plasma. RESULTS: [68Ga]Ga-DOTA-GIP1234 was synthesized with non-decay corrected radiochemical yield of 88 ± 3.7 % and radiochemical purity of 97.8 ± 0.8 %. The molar activity for the radiotracer was 8.1 ± 1.1 MBq/nmol. [68Ga]Ga-DOTA-GIP1234 was stable and maintained affinity to huGIPR HEK293 cells (dissociation constant (Kd) = 40 ± 12.5 nM). The binding of [68Ga]Ga-DOTA-GIP1234 to huGCGR and huGLP1R cells was insignificant. Pre-incubation of huGIPR HEK293 cell sections with tirzepatide resulted in the decrease of [68Ga]Ga-DOTA-GIP1234 binding by close to 90 %. [68Ga]Ga-DOTA-GIP1234 displayed slow blood clearance in pigs with SUV = 3.5 after 60 min. Blood retention of the tracer in rat was 2-fold higher than that of [68Ga]Ga-DOTA-C803-GIP. [68Ga]Ga-DOTA-GIP1234 also demonstrated strong liver uptake in both pig and rat combined with decreased renal excretion. The concentration dependent binding of [68Ga]Ga-DOTA-GIP1234 to albumin was confirmed in situ by PAGE. CONCLUSION: [68Ga]Ga-DOTA-GIP1234 demonstrated nanomolar affinity and selectivity for huGIPR in vitro. Addition of a fatty acid moiety prolonged blood circulation time and tissue exposure in both rat and pig in vivo. However, the liver uptake was also increased which may make PET imaging of abdominal tissues such as pancreas challenging. The investigation of the influence of fatty acid moiety on the biological performance of the peptide ligand paved the way for further rational design of GIPR ligand analogues with improved characteristics.


Asunto(s)
Radioisótopos de Galio , Péptidos , Receptores de la Hormona Gastrointestinal , Ratas , Humanos , Animales , Porcinos , Células HEK293 , Ligandos , Radioisótopos de Galio/química , Semivida , Péptidos/química , Albúminas , Aminoácidos
2.
ChemMedChem ; 18(13): e202300127, 2023 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-37276375

RESUMEN

The status of industrial Medicinal Chemistry was discussed with European Medicinal Chemistry Leaders from large to mid-sized pharma and CRO companies as well as biotechs. The chemical modality space has expanded recently from small molecules to address new challenging targets. Besides the classical SAR/SPR optimization of drug molecules also their 'greenness' has increasing importance. The entire pharma discovery ecosystem has developed significantly. Beyond pharma and academia new key players such as Biotech and integrated CROs as well as Digital companies have appeared and are now to a large extend fueled by VC money. Digitalization is happening everywhere but surprisingly did not change speed and success rates of projects so far. Future Medicinal Chemists will still have to be excellent synthetic chemists but in addition they must be knowledgeable in new computational areas such as data sciences. Their ability to collaborate and to work in teams is key.


Asunto(s)
Química Farmacéutica , Industria Farmacéutica , Ecosistema , Europa (Continente)
3.
J Nucl Med ; 63(5): 794-800, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34503957

RESUMEN

The glucagonlike peptide-1 receptor (GLP1R) is a gut hormone receptor, intricately linked to regulation of blood glucose homeostasis via several mechanisms. It is an established and emergent drug target in metabolic disease. The PET radioligand 68Ga-DO3A-VS-exendin4 (68Ga-exendin4) has the potential to enable longitudinal studies of GLP1R in the human pancreas. Methods:68Ga-exendin4 PET/CT examinations were performed on overweight-to-obese individuals with type 2 diabetes (n = 13) as part of a larger target engagement study (NCT03350191). A scanning protocol was developed to optimize reproducibility (target amount of 0.5 MBq/kg [corresponding to peptide amount of <0.2 µg/kg], blood sampling, and tracer stability assessment). The pancreas and abdominal organs were segmented, and binding was correlated with clinical parameters. Results: Uptake of 68Ga-exendin4 in the pancreas, but not in other abdominal tissues, was high but variable between individuals. There was no evidence of self-blocking of GLP1R by the tracer in this protocol, despite the high potency of exendin4. The results showed that a full dynamic scan can be simplified to a short static scan, potentially increasing throughput and reducing patient discomfort. The 68Ga-exendin4 concentration in the pancreas (i.e., GLP1R density) correlated inversely with the age of the individual and tended to correlate positively with body mass index. However, the total GLP1R content in the pancreas did not. Conclusion: In summary, we present an optimized and simplified 68Ga-exendin4 scanning protocol to enable reproducible imaging of GLP1R in the pancreas. 68Ga-exendin4 PET may enable quantification of longitudinal changes in pancreatic GLP1R during the development of type 2 diabetes, as well as target engagement studies of novel glucagonlike peptide-1 agonists.


Asunto(s)
Diabetes Mellitus Tipo 2 , Receptor del Péptido 1 Similar al Glucagón , Diabetes Mellitus Tipo 2/diagnóstico por imagen , Radioisótopos de Galio , Receptor del Péptido 1 Similar al Glucagón/metabolismo , Humanos , Péptidos/química , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/métodos , Reproducibilidad de los Resultados
4.
Pharmaceuticals (Basel) ; 16(1)2022 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-36678558

RESUMEN

Imaging and radiotherapy targeting the glucose-dependent insulinotropic polypeptide receptor (GIPR) could potentially benefit the management of neuroendocrine neoplasms (NENs), complementing clinically established radiopharmaceuticals. The aim of this study was to evaluate a GIPR-targeting positron emission tomography (PET) radioligand with receptor-specific binding, fast blood clearance, and low liver background uptake. The peptide DOTA-bioconjugate, C803-GIP, was developed based on the sequence of the endogenous GIP(1-30) and synthetic exendin-4 peptides with selective amino acid mutations to combine their specificity for the GIPR and in vivo stability, respectively. The 68Ga-labeled bioconjugate was evaluated in vitro in terms of binding affinity, specificity, and internalization in HEK293 cells transfected with the human GIPR, GLP1, or GCG receptors and in sections of human insulinoma and NENs. In vivo binding specificity, biodistribution, and tissue background were investigated in mice bearing huGIPR-HEK293 xenografts and in a pig. Ex vivo organ distribution, pharmacokinetics, and dosimetry were studied in normal rats. [68Ga]Ga-C803-GIP was stable and demonstrated a high affinity to the huGIPR-HEK293 cells. Binding specificity was demonstrated in vitro in frozen sections of NENs and huGIPR-HEK293 cells. No specific uptake was observed in the negative controls of huGLP1R and huGCGR cells. A novel rationally designed PET radioligand, [68Ga]Ga-C803-GIP, demonstrated promising binding characteristics and specificity towards the GIPR.

5.
Cell Metab ; 34(1): 59-74.e10, 2022 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-34932984

RESUMEN

Unimolecular triple incretins, combining the activity of glucagon-like peptide-1 (GLP-1), glucose-dependent insulinotropic polypeptide (GIP), and glucagon (GCG), have demonstrated reduction in body weight and improved glucose control in rodent models. We developed SAR441255, a synthetic peptide agonist of the GLP-1, GCG, and GIP receptors, structurally based on the exendin-4 sequence. SAR441255 displays high potency with balanced activation of all three target receptors. In animal models, metabolic outcomes were superior to results with a dual GLP-1/GCG receptor agonist. Preclinical in vivo positron emission tomography imaging demonstrated SAR441255 binding to GLP-1 and GCG receptors. In healthy subjects, SAR441255 improved glycemic control during a mixed-meal tolerance test and impacted biomarkers for GCG and GIP receptor activation. Single doses of SAR441255 were well tolerated. The results demonstrate that integrating GIP activity into dual GLP-1 and GCG receptor agonism provides improved effects on weight loss and glycemic control while buffering the diabetogenic risk of chronic GCG receptor agonism.


Asunto(s)
Receptor del Péptido 1 Similar al Glucagón , Control Glucémico , Incretinas , Receptores de la Hormona Gastrointestinal , Receptores de Glucagón , Pérdida de Peso , Animales , Polipéptido Inhibidor Gástrico , Péptido 1 Similar al Glucagón , Receptor del Péptido 1 Similar al Glucagón/agonistas , Humanos , Incretinas/farmacología , Péptidos/farmacología , Receptores de la Hormona Gastrointestinal/agonistas , Receptores de Glucagón/agonistas , Pérdida de Peso/efectos de los fármacos
6.
Diabetes ; 70(4): 842-853, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33547046

RESUMEN

Targeting of the glucose-dependent insulinotropic polypeptide receptor (GIPR) is an emerging strategy in antidiabetic drug development. The aim of this study was to develop a positron emission tomography (PET) radioligand for the GIPR to enable the assessment of target distribution and drug target engagement in vivo. The GIPR-selective peptide S02-GIP was radiolabeled with 68Ga. The resulting PET tracer [68Ga]S02-GIP-T4 was evaluated for affinity and specificity to human GIPR (huGIPR). The in vivo GIPR binding of [68Ga]S02-GIP-T4 as well as the occupancy of a drug candidate with GIPR activity were assessed in nonhuman primates (NHPs) by PET. [68Ga]S02-GIP-T4 bound with nanomolar affinity and high selectivity to huGIPR in overexpressing cells. In vivo, pancreatic binding in NHPs could be dose-dependently inhibited by coinjection of unlabeled S02-GIP-T4. Finally, subcutaneous pretreatment with a high dose of a drug candidate with GIPR activity led to a decreased pancreatic binding of [68Ga]S02-GIP-T4, corresponding to a GIPR drug occupancy of almost 90%. [68Ga]S02-GIP-T4 demonstrated a safe dosimetric profile, allowing for repeated studies in humans. In conclusion, [68Ga]S02-GIP-T4 is a novel PET biomarker for safe, noninvasive, and quantitative assessment of GIPR target distribution and drug occupancy.


Asunto(s)
Polipéptido Inhibidor Gástrico/metabolismo , Glucosa/metabolismo , Tomografía de Emisión de Positrones/métodos , Receptores de la Hormona Gastrointestinal/metabolismo , Animales , Femenino , Humanos , Hipoglucemiantes , Masculino , Radioquímica , Ratas , Transducción de Señal/fisiología
7.
J Nucl Med ; 62(6): 833-838, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33097629

RESUMEN

Despite the importance of the glucagon receptor (GCGR) in disease and in pharmaceutical drug development, there is a lack of specific and sensitive biomarkers of its activation in humans. The PET radioligand 68Ga-DO3A-VS-Tuna-2 (68Ga-Tuna-2) was developed to yield a noninvasive imaging marker for GCGR target distribution and drug target engagement in humans. Methods: The biodistribution and dosimetry of 68Ga-Tuna-2 was assessed by PET/CT in 13 individuals with type 2 diabetes as part of a clinical study assessing the occupancy of the dual GCGR/glucagon like peptide-1 receptor agonist SAR425899. Binding of 68Ga-Tuna-2 in liver and reference tissues was evaluated and correlated to biometrics (e.g., weight or body mass index) or other biomarkers (e.g., plasma glucagon levels). Results:68Ga-Tuna-2 binding was seen primarily in the liver, which is in line with the strong expression of GCGR on hepatocytes. The kidneys demonstrated high excretion-related retention, whereas all other tissue demonstrated rapid washout. The SUV55 min (SUV during the last 10-min time frame, 50-60 min after administration) uptake endpoint was sensitive to endogenous levels of glucagon. 68Ga-Tuna-2 exhibited a safe dosimetry profile and no adverse events after intravenous administration. Conclusion:68Ga-Tuna-2 can be used for safe and accurate assessment of the GCGR in human. It may serve as an important tool in understanding the in vivo pharmacology of novel drugs engaging the GCGR.


Asunto(s)
Diabetes Mellitus Tipo 2/diagnóstico por imagen , Diabetes Mellitus Tipo 2/metabolismo , Receptores de Glucagón/metabolismo , Adulto , Peso Corporal , Femenino , Radioisótopos de Galio , Humanos , Riñón/metabolismo , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiometría , Distribución Tisular
8.
Pharmaceuticals (Basel) ; 13(8)2020 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-32752075

RESUMEN

Introduction: [68Ga]Ga-DO3A-VS-Cys40-Tuna-2 (previously published as [68Ga]Ga-DO3A-VS-Cys40-S01-GCG) has shown high-affinity specific binding to the glucagon receptor (GCGR) in vitro and in vivo in rats and non-human primates in our previous studies, confirming the suitability of the tracer for drug development applications in humans. The manufacturing process of [68Ga]Ga-DO3A-VS-Cys40-Tuna-2 was automated for clinical use to meet the radiation safety and good manufacturing practice (GMP) requirements. Methods: The automated synthesis platform (Modular-Lab PharmTrace, Eckert & Ziegler, Eurotope, Germany), disposable cassettes for 68Ga-labeling, and pharmaceutical-grade 68Ge/68Ga generator (GalliaPharm®) used in the study were purchased from Eckert & Ziegler. The parameters such as time, temperature, precursor concentration, radical scavenger, buffer concentration, and pH, as well as product purification step, were investigated and optimized. Process optimization was conducted with regard to product quality and quantity, as well as process reproducibility. The active pharmaceutical ingredient starting material DO3A-VS-Cys40-Tuna-2 (GMP-grade) was provided by Sanofi Aventis. Results: The reproducible and GMP-compliant automated production of [68Ga]Ga-DO3A-VS-Cys40-Tuna-2 with on-line documentation was developed. The non-decay-corrected radiochemical yield was 45.2 ± 2.5% (n = 3, process validation) at the end of the synthesis with a labeling synthesis duration of 38 min and a quality controlincluding release procedure of 20 min. The radiochemical purity of the product was 98.9 ± 0.6% (n = 17) with the total amount of the peptide in the preparation of 48 ± 2 µg (n = 3, process validation). Radionuclidic purity, sterility, endotoxin content, residual solvent content, and sterile filter integrity tests met the acceptance criteria. The product was stable at ambient temperature for at least 2 h. Conclusion: The fully automated GMP-compliant manufacturing process was developed and thoroughly validated. The resulting [68Ga]Ga-DO3A-VS-Cys40-Tuna-2 was used in a clinical study for accurate quantification of GCGR occupancy by a dual anti-diabetic drug in vivo in humans.

9.
Diabetes Obes Metab ; 22(8): 1328-1338, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32196896

RESUMEN

AIMS: To test specific mono-agonists to the glucagon-like peptide-1 receptor (GLP-1R), glucagon receptor (GCGR) and glucose-dependent insulinotropic peptide receptor (GIPR), individually and in combination, in a mouse model of diet-induced non-alcoholic steatohepatitis (NASH) and fibrosis in order to decipher the contribution of their activities and potential additive effects to improving systemic and hepatic metabolism. MATERIALS AND METHODS: We induced NASH by pre-feeding C57BL/6J mice a diet rich in fat, fructose and cholesterol for 36 weeks. This was followed by 8 weeks of treatment with the receptor-specific agonists 1-GCG (20 µg/kg twice daily), 2-GLP1 (3 µg/kg twice daily) or 3-GIP (30 µg/kg twice daily), or the dual (1 + 2) or triple (1 + 2 + 3) combinations thereof. A dual GLP-1R/GCGR agonistic peptide, 4-dual-GLP1/GCGR (30 µg/kg twice daily), and liraglutide (100 µg/kg twice daily) were included as references. RESULTS: Whereas low-dose 1-GCG or 3-GIP alone did not influence body weight, liver lipids and histology, their combination with 2-GLP1 provided additional weight loss, reduction in liver triglycerides and improvement in histological disease activity score. Notably, 4-dual-GLP-1R/GCGR and the triple combination of selective mono-agonists led to a significantly stronger reduction in the histological non-alcoholic fatty liver disease activity score compared to high-dose liraglutide, at the same extent of body weight loss. CONCLUSIONS: GCGR and GIPR agonism provide additional, body weight-independent improvements on top of GLP-1R agonism in a murine model of manifest NASH with fibrosis.


Asunto(s)
Incretinas , Enfermedad del Hígado Graso no Alcohólico , Animales , Receptor del Péptido 1 Similar al Glucagón , Incretinas/uso terapéutico , Ratones , Ratones Endogámicos C57BL , Enfermedad del Hígado Graso no Alcohólico/tratamiento farmacológico , Receptores de Glucagón
10.
Sci Rep ; 9(1): 14960, 2019 10 18.
Artículo en Inglés | MEDLINE | ID: mdl-31628379

RESUMEN

The glucagon receptor (GCGR) is an emerging target in anti-diabetic therapy. Reliable biomarkers for in vivo activity on the GCGR, in the setting of dual glucagon-like peptide 1/glucagon (GLP-1/GCG) receptor agonism, are currently unavailable. Here, we investigated [68Ga]Ga-DO3A-S01-GCG as a biomarker for GCGR occupancy in liver, the tissue with highest GCGR expression, in non-human primates (NHP) by PET. [68Ga]Ga-DO3A-S01-GCG was evaluated by dynamic PET in NHPs by a dose escalation study design, where up to 67 µg/kg DO3A-S01-GCG peptide mass was co-injected. The test-retest reproducibility of [68Ga]Ga-DO3A-S01-GCG binding in liver was evaluated. Furthermore, we investigated the effect of pre-treatment with acylated glucagon agonist 1-GCG on [68Ga]Ga-DO3A-S01-GCG binding in liver. [68Ga]Ga-DO3A-S01-GCG bound to liver in vivo in a dose-dependent manner. Negligible peptide mass effect was observed for DO3A-S01-GCG doses <0.2 µg/kg. In vivo Kd for [68Ga]Ga-DO3A-S01-GCG corresponded to 0.7 µg/kg, which indicates high potency. The test-retest reproducibility for [68Ga]Ga-DO3A-S01-GCG binding in liver was 5.7 ± 7.9%. Pre-treatment with 1-GCG, an acylated glucagon agonist, resulted in a GCGR occupancy of 61.5 ± 9.1% in liver. Predicted human radiation dosimetry would allow for repeated annual [68Ga]Ga-DO3A-S01-GCG PET examinations. In summary, PET radioligand [68Ga]Ga-DO3A-S01-GCG is a quantitative biomarker of in vivo GCGR occupancy.


Asunto(s)
Biomarcadores/metabolismo , Receptores de Glucagón/metabolismo , Animales , Femenino , Receptor del Péptido 1 Similar al Glucagón/metabolismo , Humanos , Ligandos , Hígado/diagnóstico por imagen , Hígado/metabolismo , Macaca fascicularis , Masculino , Péptidos/metabolismo , Tomografía Computarizada por Tomografía de Emisión de Positrones , Unión Proteica , Radiometría , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Bazo/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA