Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Molecules ; 25(21)2020 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-33182383

RESUMEN

A new modified ion-selective electrode with membranes of LaF3 single crystals with different internal contacts (solid steel or electrolyte) and with FexOy nanoparticles as loading was developed. The best response characteristic with linear potential change was found in the fluoride concentration range from 10-1 to 3.98 × 10-7 M. The detection limit for the electrolyte contact was determined at 7.41 × 10-8 M with a regression coefficient of 0.9932, while the regression coefficient for the solid contact was 0.9969. The potential change per concentration decade ranged from 50.3 to 62.4 mV, depending on whether the contact was solid or electrolytic. The prepared modified electrode has a long lifetime, as well as the possibility of application in different positions (solid contact), and it can also be used for the determination of iron ions. The electrode characterization was performed with scanning electron microscopy and elemental analysis with the technique of electron-dispersive X-ray spectroscopy.


Asunto(s)
Electrodos , Fluoruros/química , Iones , Nanopartículas del Metal/química , Nanotecnología/métodos , Concentración de Iones de Hidrógeno , Lantano/química , Límite de Detección , Modelos Lineales , Metales/química , Microscopía Electrónica de Rastreo , Espectroscopía de Fotoelectrones , Potenciometría/métodos
2.
Acta Chim Slov ; 57(2): 318-24, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24061726

RESUMEN

S,S'-bis(2-aminophenyl)ethanebis(thioate), (APhET), is reported as N2S2 ligand which form chelate with copper of high stability as compared to the other metals. Two modification of APhET, simpler 1,2-di-(o-aminophenylthio)ethane (DAPhTE), and the complex one 1,2-di-(o-salicylaldiminophenylthio)ethane (SAPhTE), were examined as the active material for copper(II) ion selective PVC membrane electrodes, and observed results are correlated. The obtained results with DAPhTE based electrodes show that only coordination abilities of ligand are insufficient for preparing the efficient membrane material. On the other hand, the results that are achieved with electrodes based on SAPhTE actuate interaction of ligand with polymer membrane matrix and necessity of ionophore immobilization in membrane. Optimized SAPhTE based membrane electrode has a linear range down to 10-6 mol L-1, with slope of 27.0 mV per decade, very rapid response time (under 5 seconds) and detection limit of 5.1 × 10-7 mol L-1. Such electrode is suitable for determination of copper(II) in analytical measurements by direct potentiometry and in potentiometric titrations, within pH between 2 and 7. The electrode is selective for copper(II) ions over a large number of metal ions, with the exception on Hg2+ ion when is present in concentrations above 2 × 10-5 mol L-1.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA