Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Vasc Endovascular Surg ; 46(3): 229-35, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22504513

RESUMEN

PURPOSE: To compare the incidence of distal emboli occurring during percutaneous transluminal angioplasty (PTA) and primary stent on the superficial femoral artery (SFA) METHODS: A total of 50 consecutive patients were entered in a prospective, randomized trial. Inclusion criteria were the presence of symptomatic limb ischemia due to stenosis or occlusion of the SFA. An embolic protection device was placed in the popliteal artery. The patients were then randomly assigned to undergo primary stent implantation or PTA. The filters were retrieved and sent for histologic examination. RESULTS: Stenting in the SFA produced more emboli (1.44 mm(3)) than PTA (0.772 mm(3)), P = .031. Reanalyzing the patients according to actual treatment performed, volume of debris in the stent group was 1.271 mm(3) and in the PTA group was 0.191 mm(3), P = .00087. CONCLUSION: Volume of embolized material during endovascular interventions in the SFA-above-knee popliteal artery is higher when a stent is used.


Asunto(s)
Angioplastia de Balón/instrumentación , Arteriopatías Oclusivas/terapia , Dispositivos de Protección Embólica , Embolia/prevención & control , Arteria Femoral , Arteria Poplítea , Stents , Anciano , Angioplastia de Balón/efectos adversos , Índice Tobillo Braquial , Arteriopatías Oclusivas/complicaciones , Arteriopatías Oclusivas/diagnóstico , Arteriopatías Oclusivas/fisiopatología , Constricción Patológica , Embolia/etiología , Embolia/patología , Embolia/fisiopatología , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Incidencia , Italia , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Análisis Multivariante , Oportunidad Relativa , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Estudios Prospectivos , Diseño de Prótesis , Radiografía , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular
2.
Vascular ; 19(4): 214-7, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21764844

RESUMEN

The aim was to present a technical modification to the 'funnel technique' that allows endovascular repair of infrarenal abdominal aortic aneurysms with an ectatic neck. The body of the Excluder endograft is opened inside the aneurysm, using the slow deployment technique, stopping as soon as the contralateral limb is open. The gate is cannulated in the usual fashion. A percutaneous transluminal angioplasty (PTA) balloon is introduced in the contralateral limb and inflated to nominal pressure. By pulling the introducer of the Excluder delivery system on one side and the PTA balloon on the other, the graft is positioned on the bifurcation with the contralateral leg inside the common iliac artery. At this point, the ipsilateral iliac leg is deployed and the thoracic endograft can be positioned through the abdominal component. Finally, the contralateral iliac leg is deployed. The technique described offers a simple method to treat aortic abdominal aneurysms with an ectatic neck by positioning a bifurcated abdominal graft in such a way that subsequent insertion of the thoracic component is facilitated.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Humanos , Masculino , Diseño de Prótesis , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
3.
Ann Vasc Surg ; 25(7): 980.e11-3, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21621376

RESUMEN

Profunda femoris artery (PFA) aneurysms are rare and they are usually treated with open surgery. We report the case of an 87-year-old patient who during the preoperative work-up for an abdominal aortic aneurysm was found to have a 4.2-cm aneurysm of the right PFA. A percutaneous transcatheter coil embolization was successfully performed using a contralateral retrograde approach. To date, only three patients, including the present case, have been treated with transcatheter coil embolization for a PFA aneurysm. In the absence of concomitant superficial femoral artery disease, embolization of aneurysms of the profunda femoris seems to be a safe and minimally invasive alternative to open repair in selected patients.


Asunto(s)
Aneurisma/terapia , Embolización Terapéutica , Arteria Femoral , Anciano de 80 o más Años , Aneurisma/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Arteria Femoral/diagnóstico por imagen , Humanos , Masculino , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA