Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Chem ; 7: 835, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31850321

RESUMEN

Prior to mass spectrometry, on-line sample preparation can be beneficial to reduce manual steps, increase speed, and enable analysis of limited sample amounts. For example, bottom-up proteomics sample preparation and analysis can be accelerated by digesting proteins to peptides in an on-line enzyme reactor. We here focus on low-backpressure 100 µm inner diameter (ID) × 160 mm, 180 µm ID × 110 mm or 250 µm ID × 140 mm vinyl azlactone-co-ethylene dimethacrylate [poly(VDM-co-EDMA)] monoliths as supports for immobilizing of additional molecules (i.e., proteases or drugs), as the monolith was expected to have few unspecific interactions. For on-line protein digestion, monolith supports immobilized with trypsin enzyme were found to be suited, featuring the expected characteristics of the material, i.e., low backpressure and low carry-over. Serving as a functionalized sample loop, the monolith units were very simple to connect on-line with liquid chromatography. However, for on-line target deconvolution, the monolithic support immobilized with a Wnt pathway inhibitor was associated with numerous secondary interactions when exploring the possibility of selectively trapping target proteins by drug-target interactions. Our initial observations suggest that (poly(VDM-co-EDMA)) monoliths are promising for e.g., on-line bottom-up proteomics, but not a "fit-for-all" material. We also discuss issues related to the repeatability of monolith-preparations.

2.
Anal Chem ; 90(23): 13860-13866, 2018 12 04.
Artículo en Inglés | MEDLINE | ID: mdl-30384595

RESUMEN

An online microfluidics-mass spectrometry platform was developed for determining proteotypic peptides from in-solution digested samples. Accelerated and selective sample cleanup was achieved by integrating proteotypic epitope peptide immunoextraction with nano liquid chromatography-tandem mass spectrometry (online IE-nanoLC-MS/MS). Ten individually prepared 180 µm inner diameter capillaries with ethylene glycol dimethacrylate- co-vinyl azlactone (EDMA- co-VDM) monoliths were immobilized with anti-protein antibodies that are used in routine immunoassays of the intact small cell lung cancer biomarker ProGRP. The resulting AB columns provided linearity correlation coefficients of 0.96-0.99 for protein amounts and concentrations of 10 pg to 5 ng and 0.5-250 ng/mL, respectively. The columns/platform gave relative peak area RSDs below 15%. The IE-nanoLC-MS/MS platform provided a limit of detection (LOD) of 520 pg/mL of ProGRP in human serum. The approach was applicable for other matrixes and proteins, i.e., primary glioblastoma cells and endogenous αV integrin chain. Thus, EDMA- co-VDM monoliths immobilized with antibodies are suited for automated peptide capture in microfluidic formats.


Asunto(s)
Acrilatos/química , Anticuerpos/química , Anticuerpos/inmunología , Biomarcadores de Tumor/sangre , Neoplasias Pulmonares/química , Nanotecnología , Fragmentos de Péptidos/sangre , Carcinoma Pulmonar de Células Pequeñas/química , Acrilatos/inmunología , Biomarcadores de Tumor/inmunología , Cromatografía Liquida , Humanos , Inmunoensayo , Neoplasias Pulmonares/sangre , Técnicas Analíticas Microfluídicas , Fragmentos de Péptidos/inmunología , Proteínas Recombinantes/sangre , Proteínas Recombinantes/inmunología , Carcinoma Pulmonar de Células Pequeñas/sangre , Espectrometría de Masas en Tándem
3.
J Chromatogr A ; 1534: 195-200, 2018 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-29290401

RESUMEN

Open tubular liquid chromatography columns with organic polymer layers can be powerful tools for high sensitivity measurements in e.g. proteomics. However, these narrow columns are challenging to characterize. A two-electrode system, often used for bioimpendance measurements, was used to study poly(styrene-co-divinylbenzene = PS-DVB) polymer layered open tubular (PLOT) liquid chromatography columns with 10 µm inner diameters. The system performed electrical resistance measurements (ERM) for assessing layer thickness and porosity. Layer determination results were comparable (but more precise) to that obtained with scanning electron microscopy (SEM). Porosity examinations with ERM casted doubt on the presence/availability of pores in the layers investigated.


Asunto(s)
Cromatografía Liquida/métodos , Electrodos , Microscopía Electrónica de Rastreo , Poliestirenos/química , Porosidad , Proteómica
4.
J Chromatogr A ; 1518: 104-110, 2017 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-28882340

RESUMEN

An open tubular (OT) sample preparation/separation platform was developed. A multi-channel polymer layer open tubular (mPLOT) solid phase extraction (SPE) column was prepared by wall-coating the 126 channels (8µm inner diameter (ID) each) of a crystal fiber capillary with an organic polymer, namely poly(styrene-co-octadecene-co-divinylbenzene) (PS-OD-DVB). The mPLOT SPE was coupled on-line with a 10µm×2m poly(styrene-co-divinylbenzene) (PS-DVB) OT liquid chromatography column with nanospray mass spectrometry (OTLC-MS). Compared to using monolithic/particle-packed SPEs, mPLOT-SPE-OTLC allowed both fast loading and sufficient refocusing on the OT analytical column of small model compounds (sulfonamides≈300Da). Using automatic filtration/filter back-flushing (AFFL) plumbing, the mPLOT SPE column gave a constant and low back-pressure ≈35bar at 0.5µL/min. Surprisingly large sample volumes (10µL) were possible to be injected using a 12cm mPLOT.


Asunto(s)
Técnicas de Química Analítica/instrumentación , Cromatografía Liquida , Espectrometría de Masas , Extracción en Fase Sólida/instrumentación , Poliestirenos/química , Polivinilos/química
5.
Anal Chem ; 89(17): 8667-8673, 2017 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-28783436

RESUMEN

For counterterrorism purposes, a selective nano liquid chromatography-mass spectrometry (nanoLC-MS) platform was developed for detecting the highly lethal protein ricin from castor bean extract. Manual sample preparation steps were omitted by implementing a trypsin/Lys-C enzyme-immobilized multichannel reactor (MCR) consisting of 126 channels (8 µm inner diameter in all channels) that performed online digestion of proteins (5 min reaction time, instead of 4-16 h in previous in-solution methods). Reduction and alkylation steps were not required. The MCR allowed identification of ricin by signature peptides in all targeted mode injections performed, with a complete absence of carry-over in blank injections. The MCRs (interior volume ≈ 1 µL) have very low backpressure, allowing for trivial online coupling with commercial nanoLC-MS systems. The open tubular nature of the MCRs allowed for repeatable within/between-reactor preparation and performance.


Asunto(s)
Terrorismo Químico/prevención & control , Cromatografía Liquida/métodos , Ricina/análisis , Espectrometría de Masas en Tándem/métodos , Reactores Biológicos , Ricinus communis/química , Enzimas Inmovilizadas/química , Metaloendopeptidasas/química , Ricina/química , Ricina/aislamiento & purificación , Tripsina/química
6.
J Chromatogr A ; 1498: 111-119, 2017 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-28385266

RESUMEN

Self-preparation of nano liquid chromatography (nLC) columns has advantages regarding cost and flexibility. For targeted proteomics, we evaluated several approaches for particle-packing nLC columns and manufacturing fritless silica-based monolithic trap columns (50µm inner diameter). Our preferred approach for nLC column preparation was to magnetically stir Accucore core shell particles (C18 stationary phase) in ACN/water (80/20, v/v) suspensions during pressure-driven filling of polymer-fritted standard fused silica capillaries. The columns were ready for use about one hour after preparation had begun. They had comparable peak capacities (peptides) to commercial columns, and satisfactory within/between-column retention time repeatability, suited for targeted proteomics. Packing with commercial capillary housings/nanospray emitters did not improve performance compared to packing with in-house fritted stock fused silica capillary tubing. For trap columns, several recipes for narrow bore silica-based monolithic columns were evaluated, and we found the recipe by Zou et al. (2005) to be reproducible. Compared to the standard C18 trap column for Accucore nLC columns, monolith trap columns (C8 stationary phase) significantly reduced peak widths. The readily prepared in-house columns were used for targeted detection of the enzyme CYP27A1 in cancer cells, which is associated with proliferation and metastasis of breast cancer.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Nanopartículas/química , Péptidos/análisis , Proteómica/métodos , Dióxido de Silicio/química , Línea Celular Tumoral , Colestanotriol 26-Monooxigenasa/análisis , Colestanotriol 26-Monooxigenasa/aislamiento & purificación , Humanos , Espectrometría de Masas , Microscopía Electrónica de Rastreo , Péptidos/aislamiento & purificación , Presión
7.
J Clin Invest ; 127(2): 709-719, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-28112678

RESUMEN

BACKGROUND: Sex, emotion, and reproduction are fundamental and tightly entwined aspects of human behavior. At a population level in humans, both the desire for sexual stimulation and the desire to bond with a partner are important precursors to reproduction. However, the relationships between these processes are incompletely understood. The limbic brain system has key roles in sexual and emotional behaviors, and is a likely candidate system for the integration of behavior with the hormonal reproductive axis. We investigated the effects of kisspeptin, a recently identified key reproductive hormone, on limbic brain activity and behavior. METHODS: Using a combination of functional neuroimaging and hormonal and psychometric analyses, we compared the effects of kisspeptin versus vehicle administration in 29 healthy heterosexual young men. RESULTS: We demonstrated that kisspeptin administration enhanced limbic brain activity specifically in response to sexual and couple-bonding stimuli. Furthermore, kisspeptin's enhancement of limbic brain structures correlated with psychometric measures of reward, drive, mood, and sexual aversion, providing functional significance. In addition, kisspeptin administration attenuated negative mood. CONCLUSIONS: Collectively, our data provide evidence of an undescribed role for kisspeptin in integrating sexual and emotional brain processing with reproduction in humans. These results have important implications for our understanding of reproductive biology and are highly relevant to the current pharmacological development of kisspeptin as a potential therapeutic agent for patients with common disorders of reproductive function. FUNDING: National Institute for Health Research (NIHR), Wellcome Trust (Ref 080268), and the Medical Research Council (MRC).


Asunto(s)
Emociones/efectos de los fármacos , Kisspeptinas/administración & dosificación , Sistema Límbico/diagnóstico por imagen , Sistema Límbico/fisiología , Conducta Sexual/efectos de los fármacos , Adulto , Método Doble Ciego , Humanos , Masculino
8.
Sci Rep ; 6: 31693, 2016 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-27528413

RESUMEN

The neuropeptide oxytocin (OT) is associated with a plethora of social behaviors, and is a key topic at the intersection of psychology and biology. However, tools for measuring OT are still not fully developed. We describe a robust nano liquid chromatography-mass spectrometry (nanoLC-MS) platform for measuring the total amount of OT in human plasma/serum. OT binds strongly to plasma proteins, but a reduction/alkylation (R/A) procedure breaks this bond, enabling ample detection of total OT. The method (R/A + robust nanoLC-MS) was used to determine total OT plasma/serum levels to startlingly high concentrations (high pg/mL-ng/mL). Similar results were obtained when combining R/A and ELISA. Compared to measuring free OT, measuring total OT can have advantages in e.g. biomarker studies.


Asunto(s)
Cromatografía Liquida/métodos , Oxitocina/sangre , Proteómica/métodos , Ensayo de Inmunoadsorción Enzimática , Humanos , Espectrometría de Masas/métodos , Reproducibilidad de los Resultados
9.
J Pharm Biomed Anal ; 120: 106-11, 2016 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-26719981

RESUMEN

Amicon(®) Ultra centrifugal filters were critically evaluated for various sample preparations, namely (a) proteome fractionation, (b) sample cleanup prior to liquid chromatography mass spectrometry (LC-MS) measurement of small molecules in cell lysate, and (c) separating drug-loaded nanoparticles and released drugs for accurate release profiling in biological samples. (a) Filters of supposedly differing molar mass (MM) selectivity (10, 30, 50 and 100K) were combined to attempt fractionation of samples of various complexity and concentration. However, the products had surprisingly similar MM retentate/filtrate profiles, and the filters were unsuited for proteome fractionation. (b) Centrifugal filtration was the only clean-up procedure in a FDA-guideline validated LC-MS method for determining anti-tuberculosis agents rifampicin and thioridazine in macrophage cell lysate. An additional organic solvent washing step (drug/protein-binding disruption) was required for satisfactory recovery. (c) The centrifugation filters are well suited for separating drugs and nanoparticles in simple aqueous solutions, but significantly less so for biological samples, as common drug-protein binding disruptors can dissolve NPs or be incompatible with LC-MS instrumentation.


Asunto(s)
Nanopartículas/química , Preparaciones Farmacéuticas/química , Proteínas/química , Centrifugación/métodos , Fraccionamiento Químico/métodos , Cromatografía Liquida/métodos , Peso Molecular , Proteoma/química , Solventes/química , Espectrometría de Masas en Tándem/métodos
10.
PLoS One ; 9(9): e106881, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25222838

RESUMEN

A novel open tubular nanoproteomic platform featuring accelerated on-line protein digestion and high-resolution nano liquid chromatography mass spectrometry (LC-MS) has been developed. The platform features very narrow open tubular columns, and is hence particularly suited for limited sample amounts. For enzymatic digestion of proteins, samples are passed through a 20 µm inner diameter (ID) trypsin + endoproteinase Lys-C immobilized open tubular enzyme reactor (OTER). Resulting peptides are subsequently trapped on a monolithic pre-column and transferred on-line to a 10 µm ID porous layer open tubular (PLOT) liquid chromatography LC separation column. Wnt/ß-catenein signaling pathway (Wnt-pathway) proteins of potentially diagnostic value were digested+detected in targeted-MS/MS mode in small cell samples and tumor tissues within 120 minutes. For example, a potential biomarker Axin1 was identifiable in just 10 ng of sample (protein extract of ∼1,000 HCT15 colon cancer cells). In comprehensive mode, the current OTER-PLOT set-up could be used to identify approximately 1500 proteins in HCT15 cells using a relatively short digestion+detection cycle (240 minutes), outperforming previously reported on-line digestion/separation systems. The platform is fully automated utilizing common commercial instrumentation and parts, while the reactor and columns are simple to produce and have low carry-over. These initial results point to automated solutions for fast and very sensitive MS based proteomics, especially for samples of limited size.


Asunto(s)
Proteómica/métodos , Proteínas Wnt/química , Biomarcadores/química , Células Cultivadas , Cromatografía Liquida , Humanos , Espectrometría de Masas , Espectrometría de Masas en Tándem
11.
Sci Rep ; 3: 3511, 2013 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-24336509

RESUMEN

Reliable, sensitive and automatable analytical methodology is of great value in e.g. cancer diagnostics. In this context, an on-line system for enzymatic cleavage of proteins, subsequent peptide separation by liquid chromatography (LC) with mass spectrometric detection has been developed using "sub-chip" columns (10-20 µm inner diameter, ID). The system could detect attomole amounts of isolated cancer biomarker progastrin-releasing peptide (ProGRP), in a more automatable fashion compared to previous methods. The workflow combines protein digestion using an 20 µm ID immobilized trypsin reactor with a polymeric layer of 2-hydroxyethyl methacrylate-vinyl azlactone (HEMA-VDM), desalting on a polystyrene-divinylbenzene (PS-DVB) monolithic trap column, and subsequent separation of resulting peptides on a 10 µm ID (PS-DVB) porous layer open tubular (PLOT) column. The high resolution of the PLOT columns was maintained in the on-line system, resulting in narrow chromatographic peaks of 3-5 seconds. The trypsin reactors provided repeatable performance and were compatible with long-term storage.


Asunto(s)
Cromatografía Liquida/métodos , Enzimas Inmovilizadas , Espectrometría de Masas/métodos , Proteómica , Biomarcadores , Humanos , Nanotecnología , Fragmentos de Péptidos/química , Proteómica/métodos , Proteínas Recombinantes/química , Tripsina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...