Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 13(13)2024 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-38999534

RESUMEN

Background/Objectives: To compare the epithelial thickness changes and the changes in epithelial wavefront aberrometry following spherical versus astigmatic myopic small incision lenticule extraction (SMILE). Methods: Eighty-six eyes of 86 patients who underwent SMILE were included in this retrospective study. A total of 43 eyes underwent myopic spherical correction (spherical group) and 43 eyes underwent myopic cylindrical correction (cylindrical group). The groups were matched according to the spherical equivalent of surgically corrected refraction. Subjective manifest refraction as well as high-resolution anterior segment optical coherence tomography (MS-39; CSO; Florence, Italy) were obtained preoperatively as well as 3 months postoperatively. The latter was utilized for computing epithelial wavefront aberrometry in addition to epithelial thickness mapping. Results: Epithelial thickness increased significantly in both groups after SMILE (p < 0.01). In the cylindrical group, epithelial thickening was more pronounced on the flat meridian compared to the steep meridian (p = 0.04). In both groups, epithelial wavefront aberrometry showed a significant postoperative increase in the epithelium's spherical refractive power, causing a myopization of -0.24 ± 0.42 diopters (D) in the spherical group (p < 0.01) and -0.41 ± 0.52 D in the cylindrical group (p < 0.0001). While no significant changes in epithelial cylindrical refractive power were observed in the spherical group, a significant increase was noted in the cylindrical group from -0.21 ± 0.24 D to -0.37 ± 0.31 D (p = 0.01). In both groups, epithelial higher-order aberrations increased significantly (p < 0.001). Conclusions: Postoperative epithelial remodeling after SMILE alters lower-order (sphere and cylinder) and higher-order aberrations of the corneal epithelial wavefront and might contribute to refractive undercorrection, especially in astigmatic corrections. Epithelial wavefront aberrometry can be used to quantify the refractive effect of epithelial remodeling processes after keratorefractive surgery.

2.
Ophthalmologie ; 121(3): 180-186, 2024 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-38363381

RESUMEN

BACKGROUND: In severe and recurrent ocular allergies conventional ophthalmic drugs can reach their limits, especially in chronic forms. The first novel immunomodulators and biologicals are already in clinical use and could provide relief. OBJECTIVE: Based on the immunopathophysiological mechanisms of ocular allergies, possible targets for innovative treatment approaches are presented. An overview of promising new and future immunomodulators and biologicals and their modes of action is also given. MATERIAL AND METHODS: Current reviews on ocular allergies and the treatment of systemic allergic diseases were screened. Case reports on the treatment of ocular allergy using immunomodulators and biologicals were analyzed. The clinical relevance and possible applications are presented. RESULTS: In chronic forms of ocular allergies, complex ocular surface inflammatory responses mediated via immunoglobulin E (IgE), mast cells, CD4-positive type 2 T­helper cells and eosinophilic granulocytes are predominant. Cyclosporine A 0.1% eyedrops have been approved in Europe since 2018 for children aged 4 years and older with severe vernal keratoconjunctivitis (VKC). In addition, case reports present promising data on the systemic off-label use of biologicals, such as dupilumab or omalizumab, in refractory VKC or atopic keratoconjunctivitis (AKC). CONCLUSION: A profound understanding of the immunopathophysiology of ocular allergies is necessary to detect further targets for future immunomodulators and biologicals. Currently, immunomodulatory therapy remains limited to cyclosporine A eyedrops. Other immunomodulatory agents, such as tacrolimus and biologicals can only be used off-label. Further studies on the controlled clinical use of these substances in the treatment of VKC or AKC are underway.


Asunto(s)
Conjuntivitis Alérgica , Niño , Humanos , Conjuntivitis Alérgica/tratamiento farmacológico , Ciclosporina , Tacrolimus , Factores Inmunológicos/uso terapéutico , Adyuvantes Inmunológicos/uso terapéutico , Soluciones Oftálmicas/uso terapéutico
4.
Ophthalmologie ; 120(8): 811-817, 2023 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-37438454

RESUMEN

BACKGROUND: Adequate visual acuity significantly contributes to the age-appropriate development of children's neurobehavior. Infantile corneal opacities are rare but implicate a high potential for amblyopia. OBJECTIVE: This review aims to provide an overview of the most common causes of infantile corneal opacities and highlights ophthalmopathological correlations. METHODS: The following review is based on an extensive literature search. RESULTS: If metabolic diseases, traumatic or infectious events can be excluded as a cause for an infantile corneal opacity, it is important to focus on the 3Ds, corneal dysgenesis, corneal dystrophy or corneal degeneration. DISCUSSION: If corneal opacities occur in childhood, early recognition, diagnosis, and initiation of treatment, including prophylaxis of amblyopia, are of utmost importance. In unexplained corneal opacities the histopathological work-up of the explanted cornea can contribute to the final diagnosis.


Asunto(s)
Ambliopía , Distrofias Hereditarias de la Córnea , Opacidad de la Córnea , Niño , Humanos , Ambliopía/complicaciones , Córnea/patología , Distrofias Hereditarias de la Córnea/complicaciones , Opacidad de la Córnea/diagnóstico , Agudeza Visual
6.
GMS J Med Educ ; 39(2): Doc23, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35692357

RESUMEN

Background: This project aims to develop a new concept in training pediatric cardiologists to meet the requirements of interventional cardiac catheterizations today in terms of complexity and importance. This newly developed hands-on training program is supposed to enable the acquisition of certain skills which are necessary when investigating and treating patients in a catheter laboratory. Methods: Based on anonymous CT-scans of pediatric patients' digital 3D heart models with or without cardiac defects were developed and printed three-dimensionally in a flexible material visible under X-ray. Hands-on training courses were offered using models of a healthy heart and the most common congenital heart defects (CHD). An evaluation was performed by quantifying fluoroscopy times (FL-time) and a questionnaire. Results: The acceptance of theoretical and practical contents within the hands-on training was very positive. It was demonstrated that it is possible to master various steps of a diagnostic procedure and an intervention as well as to practice and repeat them independently which significantly reduced FL-time. The participants stated that the hands-on training led to more confidence in interventions on real patients. Conclusion: With the development of a training module using 3D-printed heart models, basic and advanced training in the field of diagnostic cardiac examinations as well as interventional therapies of CHD is possible. The learning effect for both, practical skills and theoretical understanding, was significant which underlines the importance of integrating such hands-on trainings on 3D heart models in education and practical training.


Asunto(s)
Cardiología , Cardiopatías Congénitas , Cardiología/educación , Niño , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/terapia , Humanos , Aprendizaje , Impresión Tridimensional
7.
J Clin Med ; 11(10)2022 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-35629035

RESUMEN

Background: To determine whether there is a significant saving of time when using a digital cataract workflow for digital data transfer compared to a manual approach of biometry assessment, data export, intraocular lens calculation, and surgery time. Methods: In total, 48 eyes of 24 patients were divided into two groups: 24 eyes were evaluated using a manual approach, whereas another 24 eyes underwent a full digital lens surgery workflow. The primary variables for comparison between both groups were the overall time as well as several time steps starting at optical biometry acquisition until the end of the surgical lens implantation. Other outcomes, such as toric intraocular lens misalignment, reduction of cylinder, surgically induced astigmatism, prediction error, and distance visual acuity were measured. Results: Overall, the total diagnostic and surgical time was reduced from 1364.1 ± 202.6 s in the manual group to 1125.8 ± 183.2 s in the digital group (p < 0.001). The complete time of surgery declined from 756.5 ± 82.3 s to 667.3 ± 56.3 (p < 0.0005). Compared to the manual approach of biometric data export and intraocular lens calculation (76.7 ± 12.3 s) as well as the manual export of the reference image to a portable external storage device (26.8 ± 5.5 s), a highly significant saving of time was achieved (p < 0.0001). Conclusions: Using a software-based digital approach to toric intraocular lens implantation is convenient, more efficient, and thus more economical than a manual workflow in surgery practice.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA