Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biophys J ; 114(10): 2455-2464, 2018 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-29753448

RESUMEN

Photon-counting sensors based on standard complementary metal-oxide-semiconductor single-photon avalanche diodes (SPADs) represent an emerging class of imagers that enable the counting and/or timing of single photons at zero readout noise (better than high-speed electron-multiplying charge-coupling devices) and over large arrays. They have seen substantial progress over the last 15 years, increasing their spatial resolution, timing accuracy, and sensitivity while reducing spurious signals such as afterpulsing and dark counts. They are increasingly being applied for time-resolved applications with the added advantage of enabling real-time options such as autocorrelation. We report in this study on the use of such a state-of-the-art 512 × 128 SPAD array, capable of a time resolution of 10-5-10-6 s for full frames while retaining acceptable photosensitivity thanks to the use of dedicated microlenses, in a selective plane illumination-fluorescence correlation spectroscopy setup. The latter allows us to perform thousands of fluorescence-correlation spectroscopy measurements simultaneously in a two-dimensional slice of the sample. This high-speed SPAD imager enables the measurement of molecular motion of small fluorescent particles such as single chemical dye molecules. Inhomogeneities in the molecular detection efficiency were compensated for by means of a global fit of the auto- and cross-correlation curves, which also made a calibration-free measurement of various samples possible. The afterpulsing effect could also be mitigated, making the measurement of the diffusion of Alexa-488 possible, and the overall result quality was further improved by spatial binning. The particle concentrations in the focus tend to be overestimated by a factor of 1.7 compared to a confocal setup; a calibration is thus required if absolute concentrations need to be measured. The first high-speed selective plane illumination-fluorescence correlation spectroscopy in vivo measurements to our knowledge were also recorded: although two-component fit models could not be employed because of noise, the diffusion of eGFP oligomers in HeLa cells could be measured. Sensitivity and noise will be further improved in the next generation of SPAD-based widefield sensors, which are currently under testing.


Asunto(s)
Microscopía Fluorescente/instrumentación , Fotones , Semiconductores , Células HeLa , Humanos , Factores de Tiempo
2.
PLoS One ; 11(6): e0157451, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27304995

RESUMEN

Intermediate filament (IF) elongation proceeds via full-width "mini-filaments", referred to as "unit-length" filaments (ULFs), which instantaneously form by lateral association of extended coiled-coil complexes after assembly is initiated. In a comparatively much slower process, ULFs longitudinally interact end-to-end with other ULFs to form short filaments, which further anneal with ULFs and with each other to increasingly longer filaments. This assembly concept was derived from time-lapse electron and atomic force microscopy data. We previously have quantitatively verified this concept through the generation of time-dependent filament length-profiles and an analytical model that describes assembly kinetics well for about the first ten minutes. In this time frame, filaments are shorter than one persistence length, i.e. ~1 µm, and thus filaments were treated as stiff rods associating via their ends. However, when filaments grow several µm in length over hours, their flexibility becomes a significant factor for the kinetics of the longitudinal annealing process. Incorporating now additional filament length distributions that we have recorded after extended assembly times by total internal reflection fluorescence microscopy (TIRFM), we developed a Monte Carlo simulation procedure that accurately describes the underlying assembly kinetics for large time scales.


Asunto(s)
Citoplasma/metabolismo , Desmina/metabolismo , Filamentos Intermedios/metabolismo , Queratina-18/metabolismo , Queratina-8/metabolismo , Vimentina/metabolismo , Algoritmos , Citoesqueleto/metabolismo , Citoesqueleto/ultraestructura , Desmina/ultraestructura , Humanos , Filamentos Intermedios/ultraestructura , Queratina-18/ultraestructura , Queratina-8/ultraestructura , Cinética , Microscopía de Fuerza Atómica , Microscopía Electrónica , Microscopía Fluorescente , Método de Montecarlo , Factores de Tiempo , Imagen de Lapso de Tiempo/métodos , Vimentina/ultraestructura
3.
Opt Express ; 21(7): 8652-68, 2013 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-23571955

RESUMEN

Single plane illumination microscopy based fluorescence correlation spectroscopy (SPIM-FCS) is a new method for imaging FCS in 3D samples, providing diffusion coefficients, transport, flow velocities and concentrations in an imaging mode. SPIM-FCS records correlation functions over a whole plane in a sample, which requires array detectors for recording the fluorescence signal. Several types of image sensors are suitable for FCS. They differ in properties such as effective area per pixel, quantum efficiency, noise level and read-out speed. Here we compare the performance of several low light array detectors based on three different technologies: (1) Single-photon avalanche diode (SPAD) arrays, (2) passive-pixel electron multiplying charge coupled device (EMCCD) and (3) active-pixel scientific-grade complementary metal oxide semiconductor cameras (sCMOS). We discuss the influence of the detector characteristics on the effective FCS observation volume, and demonstrate that light sheet based SPIM-FCS provides absolute diffusion coefficients. This is verified by parallel measurements with confocal FCS, single particle tracking (SPT), and the determination of concentration gradients in space and time. While EMCCD cameras have a temporal resolution in the millisecond range, sCMOS cameras and SPAD arrays can extend the time resolution of SPIM-FCS down to 10 µs or lower.


Asunto(s)
Imagenología Tridimensional/instrumentación , Microscopía Fluorescente/instrumentación , Semiconductores , Espectrometría de Fluorescencia/instrumentación , Transductores , Diseño de Equipo , Análisis de Falla de Equipo , Luz
4.
Opt Express ; 20(16): 17767-82, 2012 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-23038328

RESUMEN

With the evolving technology in CMOS integration, new classes of 2D-imaging detectors have recently become available. In particular, single photon avalanche diode (SPAD) arrays allow detection of single photons at high acquisition rates (≥ 100 kfps), which is about two orders of magnitude higher than with currently available cameras. Here we demonstrate the use of a SPAD array for imaging fluorescence correlation spectroscopy (imFCS), a tool to create 2D maps of the dynamics of fluorescent molecules inside living cells. Time-dependent fluorescence fluctuations, due to fluorophores entering and leaving the observed pixels, are evaluated by means of autocorrelation analysis. The multi-τ correlation algorithm is an appropriate choice, as it does not rely on the full data set to be held in memory. Thus, this algorithm can be efficiently implemented in custom logic. We describe a new implementation for massively parallel multi-τ correlation hardware. Our current implementation can calculate 1024 correlation functions at a resolution of 10 µs in real-time and therefore correlate real-time image streams from high speed single photon cameras with thousands of pixels.


Asunto(s)
Electrónica/instrumentación , Electrónica/métodos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Algoritmos , Simulación por Computador , Fotones , Espectrometría de Fluorescencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...