Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Appl Microbiol ; 128(4): 1208-1220, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31846171

RESUMEN

AIM: Infiltration experiments aimed to show the effectivity of coral sand to remove micro-organisms in septic tank wastewater treatment system, in South Tarawa, Kiribati. METHODS AND RESULTS: Laboratory experiments evaluated effective microbial removal properties of a packed bed of coral beach sand conditioned with domestic effluent. Bacterial and viral indicators Escherichia coli J6-2, Enterococci faecalis and f-RNA (MS2) bacteriophage, along with viral pathogens adenovirus, echovirus, norovirus and rotavirus, were dosed (at 106 -107  CFU, PFU or genome copies per ml concentration) with effluent to unsaturated coral sand-packed columns. For the conditions simulated, all organisms showed removal efficiencies of >4-Log Removal Values (LRVs) (i.e. >99·99% effective reduction in number). Results revealed that the conditioned coral sand had a higher affinity for attenuating viruses than the bacteria tested. MS2 phage, adenovirus, echovirus, norovirus and rotavirus were absent in leachate from the base of the sand columns. E. coli J6-2 and E. faecalis were recovered at 100 -101  CFU (colony forming units) per ml in the column effluent, following a dosage of 106  CFU per ml. Destructive sampling of the columns after experiments revealed that a high proportion of viral pathogens were retained in the top 30 mm of the sand. CONCLUSIONS: On the basis of the relative spatial distribution of trace organisms in the sand, we speculate that adsorption processes likely dominated attenuation of the viral pathogens, more so than physical straining effects. Further study is required to fully elucidate the removal mechanisms. SIGNIFICANCE AND IMPACT OF THE STUDY: To the best of our knowledge this is the first study of the effective microbial removal capacity of coral sand under unsaturated conditions. The work represents an initial exploratory step of developing some standardized design practice of on-site wastewater treatment systems in Kiribati, to offer enhanced protection of groundwater resources and reduce diarrhoeal disease.


Asunto(s)
Antozoos/química , Arena/química , Eliminación de Residuos Líquidos/métodos , Contaminantes del Agua/aislamiento & purificación , Purificación del Agua/métodos , Adsorción , Animales , Bacterias/aislamiento & purificación , Bacterias/patogenicidad , Micronesia , Virus/aislamiento & purificación , Virus/patogenicidad
2.
Environ Pollut ; 129(2): 321-30, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-14987818

RESUMEN

Single-well reactive tracer tests, such as the push-pull test are useful tools for characterising in-situ bioattenuation processes in contaminated aquifers. However, the analytical models that are used to interpret push-pull data may be over-simplified, and potentially overlook important processes responsible for the frequent discrepancy between predicted and observed results obtained from push-pull tests. In this study, the limitations underlying the push-pull test methodology were investigated and were supported with results from a push-pull test conducted in a sulphate-reducing aquifer contaminated by crude oil. Poor (<7%) mass recovery was achieved when the push-pull test was performed in a fast-flowing aquifer, preventing a quantifiable reaction rate to be determined. Breakthrough curve data were unexplainable using simplified analytical models, but exhibited trends analogous with tests conducted by others, when >20% mass recoveries were achieved. Push-pull test data collected from sulphate-reducing aquifers indicate that the assumption of a well-mixed batch reactor system is incorrect and that reaction rates obtained from push-pull tests in such systems may be affected by the extraction regime implemented. Evidence of microbial respiration of the reactive tracer was provided by stable sulphur isotope analysis, from which an isotope fractionation factor of +9.9 +/- 8.1 per thousand was estimated. The stable isotope data support the argument that reaction rates calculated using push-pull tests are not uniformly distributed in space and time and are likely to be influenced by heterogeneities in the flow field.


Asunto(s)
Monitoreo del Ambiente/métodos , Hidrocarburos/análisis , Microbiología del Agua , Contaminantes del Agua/análisis , Animales , Biodegradación Ambiental , Radioisótopos , Ríos , Sensibilidad y Especificidad , Movimientos del Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...