Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 228
Filtrar
1.
Europace ; 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38874449

RESUMEN

Ventricular backup leads may be considered in selected patients with His bundle pacing (HBP), but it remains unknown to what extent this is useful. A total of 184 HBP patients were studied. At last follow-up, 147(79.9%) patients retained His bundle capture at programmed output. HBP lead revision was performed in 5/36(13.9%) patients without a backup lead and in 3/148(2.0%) patients with a backup lead (p=0.008). One patient without a backup lead had syncope due to atrial oversensing. Thus, implantation of ventricular backup leads may avoid lead revision and adverse events in selected HBP patients.

2.
J Am Heart Assoc ; 13(12): e035279, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38879456

RESUMEN

BACKGROUND: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased relative dyssynchrony at a given QRS duration (QRSd). Our objective was to investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. METHODS AND RESULTS: This is a post hoc analysis of the MORE-CRT MPP (More Response on Cardiac Resynchronization Therapy with Multipoint Pacing)  trial (n=3739, 28% women), with a subgroup analysis of patients with nonischemic cardiomyopathy and left bundle-branch block (n=1308, 41% women) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/left ventricular end-diastolic volume (LVEDV). Women had a higher CRT response rate than men (70.1% versus 56.8%, P<0.0001). In subgroup analysis, regression analysis of the nonischemic cardiomyopathy left bundle-branch block subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (P<0.0039). QRSd/LVEDV was significantly higher in women (0.919) versus men (0.708, P<0.001). CRT response was 78% for female patients with QRSd/LVEDV greater than the median value, compared with 68% with QRSd/LVEDV less than the median value (P=0.012). The association between CRT response and QRSd/LVEDV was strongest at QRSd <150 ms. CONCLUSIONS: In the nonischemic cardiomyopathy left bundle-branch block population, increased relative dyssynchrony in women, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150 ms. Women may benefit from CRT at a QRSd <130 ms, opening the debate on whether sex-specific QRSd cutoffs or QRS/LVEDV measurement should be incorporated into clinical guidelines.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Femenino , Masculino , Anciano , Factores Sexuales , Persona de Mediana Edad , Resultado del Tratamiento , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico , Bloqueo de Rama/terapia , Bloqueo de Rama/fisiopatología , Cardiomiopatías/fisiopatología , Cardiomiopatías/terapia , Cardiomiopatías/diagnóstico , Tamaño de los Órganos , Función Ventricular Izquierda/fisiología , Volumen Sistólico/fisiología , Corazón/fisiopatología , Electrocardiografía
3.
Heart Rhythm ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38750909

RESUMEN

BACKGROUND: The impact of left bundle branch area pacing (LBBAP) on right ventricular (RV) function and tricuspid regurgitation (TR) remains unclear. OBJECTIVE: We aimed to assess the long-term effects of LBBAP on RV performance and on TR. METHODS: RV function was evaluated using RV free wall strain, tricuspid annular plane systolic excursion, fractional area changing, and systolic velocity of the lateral tricuspid annulus. The presence of reverse septal flash (RSF) and basal bulge (BB) was used to assess RV motion pattern. The distance between the lead entry site on the interventricular septum and the septal leaflet of the tricuspid annulus (lead-TV distance) was measured. RESULTS: The analysis included 122 subjects [62 men (50.8%); mean age 76.5 ± 11.4 years] with a median follow-up of 21 months (18-24.5 months). During follow-up, RV free wall strain improved significantly (15.2 ± 5.8 vs 16.4 ± 5.5; P < .001) while tricuspid annular plane systolic excursion, systolic, and fractional area changing remained unchanged. Left ventricular ejection fraction was an independent predictor of improved RV function (B = 3.51; 95% confidence interval 1.39-8.9; P = .01). With LBBAP, RSF disappeared in 22 of 23 patients (96%) and BB in 15 of 22 patients (68%) in whom RSF and BB were present at baseline, respectively. RV function improvement was significantly higher when RSF was present at baseline (14 patients vs 11 patients; P = .02). At follow-up, no significant deterioration in TR occurred for the overall group. However, a lead-TV distance of <24.5 mm was associated with TR progression. CONCLUSION: LBBAP has a favorable impact on RV function. A basal LBBAP position is associated with worsening TR.

4.
Rev Med Suisse ; 20(875): 1034-1038, 2024 May 22.
Artículo en Francés | MEDLINE | ID: mdl-38783673

RESUMEN

In up to 30-40% of the cases acute coronary syndrome (ACS) is complicated by cardiac arrhythmias. The latter can be benign or malignant and mainly occur during the first 24 hours after myocardial infarction. Ischemia time being the key factor, arrythmias decreased dramatically since the implementation of accelerated reperfusion strategies. Bradyarrhythmias are often benign and self-limiting and are less frequent than tachyarrhythmias but can sometimes require specific treatment. The objective of this article is to provide an update on bradycardia and conduction system disorders occurring during ACS and their management.


Le syndrome coronarien aigu (SCA) est compliqué d'arythmies cardiaques jusque dans 30 à 40 % des cas. Celles-ci peuvent être bénignes ou malignes et surviennent principalement durant les premières 24 heures après l'infarctus du myocarde (IDM). Le temps d'ischémie étant le facteur clé, elles sont en baisse depuis la mise en place de stratégies de reperfusion accélérées. Les bradyarythmies, souvent bénignes et spontanément résolutives, sont moins fréquentes que les tachyarythmies mais peuvent parfois nécessiter une prise en charge spécifique. L'objectif de cet article est une mise à jour sur les bradycardies et troubles de la conduction survenant lors d'un SCA ainsi que leurs prises en charge.


Asunto(s)
Síndrome Coronario Agudo , Bradicardia , Humanos , Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/diagnóstico , Bradicardia/diagnóstico , Bradicardia/etiología , Bradicardia/terapia
5.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38753644

RESUMEN

AIMS: Monitoring current of injury (COI) during left bundle branch area pacing (LBBAP) implantation is useful to evaluate lead depth. Technical aspects for recording COI amplitude have not been well studied. Our aims were to evaluate the impact of high-pass filter settings on electrogram recordings during LBBAP implantation. METHODS AND RESULTS: Consecutive patients with successful LBBAP implantation had unipolar recordings of COI at final lead position at different high-pass filter settings (0.01-1 Hz) from the tip electrode during sensing and pacing, and from the ring electrode during sensing. Duration of saturation-induced signal loss was also measured at each filter setting. COI amplitudes were compared between lumenless and stylet-driven leads. A total of 156 patients (96 males, aged 81.4 ± 9.6 years) were included. Higher filter settings led to significantly lower COI amplitudes. In 50 patients with COI amplitude < 10 mV, the magnitude of the drop was on average 1-1.5 mV (and up to 4 mV) between 0.05 and 0.5 Hz, meaning that cut-offs may not be used interchangeably. Saturation-induced signal loss was on average 10 s at 0.05 Hz and only 2 s with 0.5 Hz. When pacing was interrupted, the sensed COI amplitude varied (either higher or lower) by up to 4 mV, implying that it is advisable to periodically interrupt pacing to evaluate the sensed COI when reaching levels of ∼10 mV. Lead type did not impact COI amplitude. CONCLUSION: High-pass filters have a significant impact on electrogram characteristics at LBBAP implantation, with the 0.5 Hz settings having the most favourable profile.


Asunto(s)
Estimulación Cardíaca Artificial , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Estimulación Cardíaca Artificial/métodos , Electrodos Implantados , Técnicas Electrofisiológicas Cardíacas , Fascículo Atrioventricular/fisiopatología , Marcapaso Artificial , Diseño de Equipo , Resultado del Tratamiento , Potenciales de Acción
6.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38412340

RESUMEN

The DF-4 defibrillator standard has been rapidly adopted due to its convenience at implantation. There are however trade-offs compared to the traditional DF-1 standard that are underappreciated. This viewpoint outlines the advantages and limitations of current defibrillator lead standards that should be kept in mind, as they impact the options that are available to deal with issues that may arise.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia
9.
Tex Heart Inst J ; 51(1)2024 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-38291909

RESUMEN

BACKGROUND: Achieving optimal exposure of the mitral valve during surgical intervention poses a significant challenge. This study aimed to compare perioperative and postoperative outcomes associated with 3 left atriotomy techniques in mitral valve surgery-the conventional direct, transseptal, and superior septal approaches-and assess differences during the surgical procedure and the postoperative period. METHODS: Inclusion criteria were patients undergoing mitral valve surgery from January 2010 to December 2020, categorized into 3 cohorts: group 1 (conventional direct; n = 115), group 2 (transseptal; n = 33), and group 3 (superior septal; n = 59). To bolster sample size, the study included patients undergoing mitral valve surgery independently or in conjunction with other procedures (eg, coronary artery bypass grafting, aortictricuspid surgery, or maze procedure). RESULTS: No substantial variance was observed in the etiology of mitral valve disease across groups, except for a higher incidence of endocarditis in group 3 (P = .01). Group 1 exhibited a higher frequency of elective surgeries and isolated mitral valve procedures (P = .008), along with reduced aortic clamping and cardiopulmonary bypass durations (P = .002). Conversely, group 3 patients represented a greater proportion of emergency procedures (P = .01) and prolonged intensive care unit and hospital stays (P = .001). No significant disparities were detected in terms of permanent pacemaker implantation, postoperative complications, or mortality among the groups. CONCLUSION: Mitral valve operations that employed these 3 atriotomy techniques demonstrated a safe profile. The conventional direct approach notably reduced aortic clamping and cardiopulmonary bypass durations. The superior septal method was primarily employed for acute pathologies, with no significant escalation in postoperative arrhythmias or permanent pacemaker implantation, although these patients had prolonged intensive care unit and hospital stays. These outcomes may be linked to the underlying pathology and nature of the surgical intervention rather than the incision method itself.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Enfermedades de las Válvulas Cardíacas/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Periodo Posoperatorio , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento
10.
Eur J Heart Fail ; 26(1): 5-17, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38169072

RESUMEN

Document Reviewers: Rudolf A. de Boer (CPG Review Co-ordinator) (Netherlands), P. Christian Schulze (CPG Review Co-ordinator) (Germany), Elena Arbelo (Spain), Jozef Bartunek (Belgium), Johann Bauersachs (Germany), Michael A. Borger (Germany), Sergio Buccheri (Sweden), Elisabetta Cerbai (Italy), Erwan Donal (France), Frank Edelmann (Germany), Gloria Färber (Germany), Bettina Heidecker (Germany), Borja Ibanez (Spain), Stefan James (Sweden), Lars Køber (Denmark), Konstantinos C. Koskinas (Switzerland), Josep Masip (Spain), John William McEvoy (Ireland), Robert Mentz (United States of America), Borislava Mihaylova (United Kingdom), Jacob Eifer Møller (Denmark), Wilfried Mullens (Belgium), Lis Neubeck (United Kingdom), Jens Cosedis Nielsen (Denmark), Agnes A. Pasquet (Belgium), Piotr Ponikowski (Poland), Eva Prescott (Denmark), Amina Rakisheva (Kazakhstan), Bianca Rocca (Italy), Xavier Rossello (Spain), Leyla Elif Sade (United States of America/Türkiye), Hannah Schaubroeck (Belgium), Elena Tessitore (Switzerland), Mariya Tokmakova (Bulgaria), Peter van der Meer (Netherlands), Isabelle C. Van Gelder (Netherlands), Mattias Van Heetvelde (Belgium), Christiaan Vrints (Belgium), Matthias Wilhelm (Switzerland), Adam Witkowski (Poland), and Katja Zeppenfeld (Netherlands) All experts involved in the development of this Focused Update have submitted declarations of interest. These have been compiled in a report and simultaneously published in a supplementary document to the Focused Update. The report is also available on the ESC website www.escardio.org/guidelines See the European Heart Journal online for supplementary documents that include evidence tables.


Asunto(s)
Cardiología , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Polonia , Reino Unido , España
12.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096587

RESUMEN

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Cardiopatía Reumática , Insuficiencia de la Válvula Tricúspide , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Cardiopatía Reumática/complicaciones , Estudios Retrospectivos
14.
medRxiv ; 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38106113

RESUMEN

Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased "relative dyssynchrony" at given QRS durations (QRSd). Objective: To investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods: A post-hoc analysis of the MORE-CRT MPP trial (n=3739, 28% female), with a sub-group analysis of patients with non-ischaemic cardiomyopathy (NICM) and left bundle branch block (LBBB) (n=1308, 41% female) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/LVEDV (left ventricular end-diastolic volume). Results: Females had a higher CRT response rate than males (70.1% vs. 56.8%, p<0.0001). Subgroup analysis: Regression analysis of the NICM LBBB subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (p<0.0039). QRSd/LVEDV was significantly higher in females (0.919) versus males (0.708, p<0.001). CRT response was 78% for female patients with QRSd/LVEDV>median value, compared to 68% < median value (p=0.012). Association between CRT response and QRSd/LVEDV was strongest at QRSd<150ms. Conclusions: In the NICM LBBB population, increased relative dyssynchrony in females, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150ms. Females may benefit from CRT at a QRSd <130ms, opening the debate on whether sex-specific QRSd cut-offs or QRS/LVEDV measurement should be incorporated into clinical guidelines.

15.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38153385

RESUMEN

It is well established that right ventricular pacing is detrimental in patients with reduced cardiac function who require ventricular pacing (VP), and alternatives nowadays are comprised of biventricular pacing (BiVP) and conduction system pacing (CSP). The latter modality is of particular interest in patients with a narrow baseline QRS as it completely avoids, or minimizes, ventricular desynchronization associated with VP. In this article, experts debate whether BiVP or CSP should be used to treat these patients.


Asunto(s)
Bloqueo Atrioventricular , Terapia de Resincronización Cardíaca , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Volumen Sistólico , Trastorno del Sistema de Conducción Cardíaco , Sistema de Conducción Cardíaco
16.
Eur Heart J Suppl ; 25(Suppl G): G4-G14, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37970514

RESUMEN

Pacing from the right ventricle is associated with an increased risk of development of congestive heart failure, increases in total and cardiac mortality, and a worsened quality of life. Conduction system pacing has become increasingly realized as an alternative to right ventricular apical pacing. Conduction system pacing from the His bundle and left bundle branch area has been shown to provide physiologic activation of the ventricle and may be an alternative to coronary sinus pacing. Conduction system pacing has been studied as an alternative for both bradycardia pacing and for heart failure pacing. In this review, we summarize the clinical results of conduction system pacing under a variety of different clinical settings. The anatomic targets of conduction system pacing are illustrated, and electrocardiographic correlates of pacing from different sites in the conduction system are defined. Ultimately, clinical trials comparing conduction system pacing with standard right ventricular apical pacing and cardiac resynchronization therapy pacing will help define its benefit and risks compared with existing techniques.

17.
Eur Heart J Suppl ; 25(Suppl G): G56-G62, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37970516

RESUMEN

With the advent of conduction system pacing, the threshold for performing 'ablate and pace' procedures for atrial fibrillation has gone down markedly in many centres due to the ability to provide a simple and physiological means of pacing the ventricles. This article reviews the technical considerations for this strategy as well as the current evidence, recognized indications, and future perspectives.

18.
Eur Heart J Suppl ; 25(Suppl G): G1-G3, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37970520
19.
Eur Heart J Cardiovasc Imaging ; 25(1): e1-e32, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-37861372

RESUMEN

More than 500 000 cardiovascular implantable electronic devices (CIEDs) are implanted in the European Society of Cardiology countries each year. The role of cardiovascular imaging in patients being considered for CIED is distinctly different from imaging in CIED recipients. In the former group, imaging can help identify specific or potentially reversible causes of heart block, the underlying tissue characteristics associated with malignant arrhythmias, and the mechanical consequences of conduction delays and can also aid challenging lead placements. On the other hand, cardiovascular imaging is required in CIED recipients for standard indications and to assess the response to device implantation, to diagnose immediate and delayed complications after implantation, and to guide device optimization. The present clinical consensus statement (Part 1) from the European Association of Cardiovascular Imaging, in collaboration with the European Heart Rhythm Association, provides comprehensive, up-to-date, and evidence-based guidance to cardiologists, cardiac imagers, and pacing specialists regarding the use of imaging in patients undergoing implantation of conventional pacemakers, cardioverter defibrillators, and resynchronization therapy devices. The document summarizes the existing evidence regarding the use of imaging in patient selection and during the implantation procedure and also underlines gaps in evidence in the field. The role of imaging after CIED implantation is discussed in the second document (Part 2).


Asunto(s)
Sistema Cardiovascular , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/terapia , Cardioversión Eléctrica , Corazón
20.
Eur Heart J Cardiovasc Imaging ; 25(1): e33-e54, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-37861420

RESUMEN

Cardiac implantable electronic devices (CIEDs) improve quality of life and prolong survival, but there are additional considerations for cardiovascular imaging after implantation-both for standard indications and for diagnosing and guiding management of device-related complications. This clinical consensus statement (part 2) from the European Association of Cardiovascular Imaging, in collaboration with the European Heart Rhythm Association, provides comprehensive, up-to-date, and evidence-based guidance to cardiologists, cardiac imagers, and pacing specialists regarding the use of imaging in patients after implantation of conventional pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy (CRT) devices. The document summarizes the existing evidence regarding the role and optimal use of various cardiac imaging modalities in patients with suspected CIED-related complications and also discusses CRT optimization, the safety of magnetic resonance imaging in CIED carriers, and describes the role of chest radiography in assessing CIED type, position, and complications. The role of imaging before and during CIED implantation is discussed in a companion document (part 1).


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables/efectos adversos , Calidad de Vida , Dispositivos de Terapia de Resincronización Cardíaca , Imagen por Resonancia Magnética , Marcapaso Artificial/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...