Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
1.
J Am Heart Assoc ; 13(14): e033125, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-38979804

RESUMEN

BACKGROUND: Mitral regurgitation (MR) is frequent in patients with aortic stenosis (AS). Although primary MR is an established negative prognostic factor, whether different mechanisms of MR have different effects on outcome is currently unknown. The aim of this study was to evaluate the impact of the MR mechanism in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: This is a retrospective observational study of patients who underwent TAVR for severe aortic stenosis in a high-volume tertiary care center. Echocardiographic comprehensive MR assessment was performed at baseline and within 3 months post TAVR. The study population was divided into 4 groups according to MR mechanism: Group I: fibro-calcific leaflet degeneration; Group II: prolapse/flail; Group III: ventricular secondary MR (functional MR); and Group IV: atrial functional MR. The study end point was a combination of death from cardiovascular cause and heart failure-related hospitalization. The study population included 427 patients (mean age 81.7±6.5 years; 71% primary MR; 62% ≥moderate MR). At 3-year follow-up, survival free from the composite end point significantly differs according to MR mechanism: it was higher in group IV (atrial functional MR, 96.6%) compared with group I (80.4%, P=0.002) and group II patients (60.7%, P=0.001), and group III (84.8%, P=0.037); patients with MR due to leaflet prolapse showed poorer prognosis compared with patients with functional MR (group III, P=0.023 and group IV, P=0.001) and with group I (P=0.040). Overall, severe MR after TAVR identified patients with poorer prognosis and was significantly more frequent in group II (46.4%, P=0.001). CONCLUSIONS: In patients undergoing TAVR, preprocedural identification of MR mechanism and mechanism provides prognostic insights.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estudios Retrospectivos , Anciano de 80 o más Años , Anciano , Resultado del Tratamiento , Ecocardiografía , Factores de Riesgo , Factores de Tiempo , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología
3.
Artículo en Inglés | MEDLINE | ID: mdl-38923261

RESUMEN

BACKGROUND: The COAPT Trial was the first ever to demonstrate a survival benefit in treating functional mitral regurgitation (FMR). That was achieved through transcatheter mitral repair in selected patients. The exact proportion of patients fulfilling COAPT selection criteria in the real-world is unknown. AIMS: To assess the applicability of COAPT criteria in real world and its impact on patients' survival. METHODS: We assessed the clinical data and follow-up results of all consecutive patients admitted for FMR at our Department between January 2016 and May 2021 according to COAPT eligibility. COAPT eligibility was retrospectively assessed by a cardiac surgeon and a cardiologist. RESULTS: Among 394 patients, 56 (14%) were COAPT eligible. The most frequent reasons for exclusion were MR ≤ 2 (22%), LVEF < 20% or >50% (19%), and non-optimized GDMT (21.3%). Among Non-COAPT patients, weighted 4-year survival was higher in patients who received MitraClip compared to those who were left in optimized medical therapy (91.5% confidence interval [CI: 0.864, 0.96] vs. 71.8% [CI: 0.509, 0.926], respectively, p = 0.027). CONCLUSIONS: Only a minority (14%) of real-world patients with FMR referred to a tertiary hospital fulfilled the COAPT selection criteria. Among Non-COAPT patients, weighted 4-year survival was higher in patients who received MitraClip compared to those who were left in optimized medical therapy (91.5% [0.864, 0.96] vs. 71.8% [0.509, 0.926], respectively, p = 0.027).

4.
Artículo en Inglés | MEDLINE | ID: mdl-38880999

RESUMEN

Nowadays, the long-life management of patients with aortic stenosis has emerged as one of the most debated issues. Transcatheter aortic valve replacement is more frequently performed in younger patients with lower surgical risk, and also the number of valve-in-valve (ViV) procedures has increased in the last few years. However, coronary obstruction is the most dreadful complication related to this procedure. To prevent coronary obstruction in the context of transcatheter aortic ViV implantation, the BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) technique was developed. Although effective, BASILICA is complex and time-consuming. Hence, simpler, reproducible, and faster strategies are desirable. Here we present a promising simplified BASILICA technique employing an Armada Balloon to perform the leaflet laceration.

5.
JACC Case Rep ; 29(4): 102200, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38379644

RESUMEN

Valve-in-ring procedures represent a feasible solution for high-risk patients with surgical repair failure. The risk of left ventricular outflow tract obstruction increases the challenge, and transcatheter approaches to prevent it are technically demanding and often do not resolve it. We demonstrate the feasibility and safety of a transseptal balloon-assisted translocation of the anterior mitral leaflet for valve-in-ring implantation.

6.
Clin Res Cardiol ; 113(1): 86-93, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37391628

RESUMEN

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic valve stenosis in elderly patients, but there is uncertainty on their long-term effectiveness. We aimed to assess the long-term outcome of patients undergoing TAVI with the Portico valve. METHODS: We retrospectively collected the data on patients in whom TAVI with Portico was attempted from 7 high-volume centres. Only patients theoretically eligible for 3 or more years of follow-up were included. Clinical outcomes, including death, stroke, myocardial infarction, reintervention for valve degeneration and hemodynamic valve performance were systematically assessed. RESULTS: A total of 803 patients were included, with 504 (62.8%) women, mean age of 82 years, median EuroSCORE II of 3.1%, and 386 (48.1%) subjects at low/moderate risk. The median follow-up was 3.0 years (3.0; 4.0). The composite of death, stroke, myocardial infarction, and reintervention for valve degeneration occurred in 37.5% (95% confidence interval: 34.1-40.9%), with all-cause death in 35.1% (31.8-38.4%), stroke in 3.4% (1.3-3.4%), myocardial infarction in 1.0% (0.3-1.5%), and reintervention for valve degeneration in 1.1% (0.6-2.1%). The mean aortic valve gradient at follow-up was 8.1 ± 4.6 mmHg, and at least moderate aortic regurgitation was present in 9.1% (6.7-12.3%). Independent predictors of major adverse events or death were: peripheral artery disease, chronic obstructive pulmonary disease, estimated glomerular filtration rate, atrial fibrillation, prior pacemaker implantation, EuroSCORE II, and reduced left ventricular ejection fraction (all p < 0.05). CONCLUSIONS: Portico use is associated with favorable long-term clinical outcomes. Clinical outcomes were largely impacted by baseline risk factors and surgical risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Infarto del Miocardio , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/cirugía , Accidente Cerebrovascular/etiología
7.
JACC Cardiovasc Interv ; 16(16): 1974-1985, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37648345

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with pure severe native aortic valve regurgitation (NAVR) has been associated with suboptimal results. The available evidence concerns mostly outdated transcatheter heart valves (THVs). OBJECTIVES: The aim of this study was to investigate the performance of new-generation THVs in patients treated for pure severe NAVR. METHODS: The PANTHEON (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve) study retrospectively included patients who underwent TAVR with currently available devices (both self-expanding [SE] and balloon expandable [BE]) for severe NAVR. Technical and device success rates as well as a composite of all-cause mortality and heart failure rehospitalization at 1 year were evaluated. The rate and clinical consequences of acute transcatheter valve embolization or migration (TVEM) were also considered. RESULTS: A total of 201 patients were included. Overall technical and device success rates were 83.6% and 76.1%, respectively, and did not differ between SE and BE devices. These figures were due mostly to TVEM occurrence (14.6% vs 16.1%; P = 0.47) and residual moderate or greater aortic regurgitation (9.2% vs 10.1%; P = 0.87). Patients who experienced TVEM compared with those without TVEM had a significantly higher incidence of the composite endpoint at 1 year (25.7% vs 15.8%; P = 0.05). CONCLUSIONS: Despite improved THV platforms and techniques, TAVR for pure severe NAVR remains a challenging procedure, with significant risk for TVEM. SE and BE platforms demonstrated comparable performance in this setting. (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve [PANTHEON]; NCT05319171).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
8.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-36883599

RESUMEN

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pronóstico , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía
9.
Am J Cardiol ; 186: 100-108, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36356428

RESUMEN

Up to half of real-world patients with secondary mitral regurgitation who underwent transcatheter edge-to-edge repair (TEER) do not meet the highly selective COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) criteria. No randomized trials or standardized and validated tools exist to evaluate the risk: benefit ratio of TEER in this specific population. We sought to derive and externally validate a clinical risk score to predict the risk of death or heart failure (HF) hospitalization for COAPT-ineligible patients who underwent TEER (CITE score). The study population consisted of patients with secondary mitral regurgitation having at least 1 exclusion criterion of the COAPT trial. The derivation cohort included 489 patients from the GIOTTO (GIse registry of Transcatheter treatment of Mitral Valve regurgitaTiOn) registry. Cox proportional hazards regression was used to identify predictors of 2-year death/HF hospitalization and develop a numerical risk score. The predictive performance was assessed in the derivation cohort and validated in 268 patients from the MiZüBr (Milan-Zürich-Brescia) registry. The CITE score (hemodynamic instability, left ventricular impairment, New York Heart Association class III/IV, peripheral artery disease, atrial fibrillation, brain natriuretic peptide, and hemoglobin) showed a c-index for 2-year death or HF hospitalization of 0.70 (95% confidence interval [CI] 0.67 to 0.73) in the derivation cohort, and 0.68 (95% CI 0.64 to 0.73) in the validation cohort. A cutoff of <12 points was selected to identify patients at lower risk of adverse outcomes, hazard ratio of 0.35 (95% CI 0.26 to 0.46). In conclusion, the CITE score is a simple 7-item tool for the prediction of death or HF hospitalization at 2 years after TEER in COAPT-ineligible patients. The score may support clinical decision-making by identifying those patients who, even if excluded from clinical trials, can still benefit from TEER.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Péptido Natriurético Encefálico , Factores de Riesgo , Resultado del Tratamiento
10.
JACC Case Rep ; 28: 102090, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38204541

RESUMEN

We report a case of patient with a single-chamber Hisian pacemaker who developed complete atrioventricular block and significant deterioration of the ventricular threshold and sensing after transcatheter aortic valve replacement. Revision of the implantation was required, with ventricular lead extraction and replacement.

11.
Eur Heart J Suppl ; 24(Suppl I): I104-I110, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36380806

RESUMEN

Severe mitral insufficiency is a feared complication that develops in 10-12% of patients with myocardial infarction and ST elevation. It results from the rupture of the papillary muscle or is secondary to an acute remodelling of the left ventricle in its entirety or of the infarcted region. The mortality of patients with acute clinical onset reaches 50%. The ideal treatment of acute mitral insufficiency is controversial and still a source of debate. Most of these patients are at high surgical risk or inoperable; therefore, they are treated conservatively and have a poor prognosis. In these candidates, percutaneous treatment of insufficiency with percutaneous edge to edge can be considered an alternative.

12.
JACC Cardiovasc Interv ; 15(15): 1543-1554, 2022 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-35926921

RESUMEN

BACKGROUND: As transcatheter aortic valve (TAV) replacement is increasingly used in patients with longer life expectancy, a sizable proportion will require redo TAV replacement (TAVR). The unique configuration of balloon-expandable TAV (bTAV) vs a self-expanding TAV (sTAV) potentially affects TAV-in-TAV outcome. OBJECTIVES: The purpose of this study was to better inform prosthesis selection, TAV-in-TAV outcomes were assessed according to the type of initial and subsequent TAV. METHODS: Patients from the Redo-TAVR registry were analyzed using propensity weighting according to their initial valve type (bTAV [n = 115] vs sTAV [n = 106]) and subsequent valve type (bTAV [n = 130] vs sTAV [n = 91]). RESULTS: Patients with failed bTAVs presented later (vs sTAV) (4.9 ± 2.1 years vs 3.7 ± 2.3 years; P < 0.001), with smaller effective orifice area (1.0 ± 0.7 cm2 vs 1.3 ± 0.8 cm2; P = 0.018) and less frequent dominant regurgitation (16.2% vs 47.3%; P < 0.001). Mortality at 30 days was 2.3% (TAV-in-bTAV) vs 0% (TAV-in-sTAV) (P = 0.499) and 1.7% (bTAV-in-TAV) vs 1.0% (sTAV-in-TAV) (P = 0.612); procedural safety was 72.6% (TAV-in-bTAV) vs 71.2% (TAV-in-sTAV) (P = 0.817) and 73.2% (bTAV-in-TAV) vs 76.5% (sTAV-in-TAV) (P = 0.590). Device success was similar according to initial valve type but higher with subsequent sTAV vs bTAV (77.2% vs 64.3%; P = 0.045), primarily because of lower residual gradients (10.3 mm Hg [8.9-11.7 mm Hg] vs 15.2 mm Hg [13.2-17.1 mm Hg]; P < 0.001). Residual regurgitation (moderate or greater) was similar after bTAV-in-TAV and sTAV-in-TAV (5.7%) and nominally higher after TAV-in-bTAV (9.1%) vs TAV-in-sTAV (4.4%) (P = 0.176). CONCLUSIONS: In selected patients, no association was observed between TAV type and redo TAVR safety or mortality, yet subsequent sTAV was associated with higher device success because of lower redo gradients. These findings are preliminary, and more data are needed to guide valve choice for redo TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Resultado del Tratamiento
13.
Eur Heart J Suppl ; 24(Suppl C): C233-C242, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35602251

RESUMEN

Recent evidence has shown that transcatheter heart valve (THV) anchoring in bicuspid aortic valve (BAV) patients occurs at the level of the raphe, known as the LIRA (Level of Implantation at the RAphe) plane. Our previous work in a cohort of 20 patients has shown that the delineation of the perimeter and device sizing at this level is associated with optimal procedural outcome. The goals of this study were to confirm the feasibility of this method, evaluate 30-day outcomes of LIRA sizing in a larger cohort of patients, assess interobserver variation and reproducibility of this sizing methodology, and analyse the interaction of LIRA-sized prostheses with the surrounding anatomy. The LIRA sizing method was applied to consecutive patients presenting to our centre with raphe-type BAV disease between November 2018 and October 2021. Supra-annular self-expanding THVs were sized based on baseline CT scan perimeters at the LIRA plane and the virtual basal ring. In cases where there was discrepancy between the two measurements, the plane with the smallest perimeter was considered the reference for prosthesis sizing. Post-procedural device success, defined according to Valve Academic Research Consortium-2 (VARC-2) criteria, was evaluated in the overall cohort. A total of 50 patients (mean age 80 ± 6 years, 70% male) with raphe-type BAV disease underwent transcatheter aortic valve replacement (TAVR) using different THV prostheses. The LIRA plane method appeared to be highly successful (100% VARC-2 device success) with no procedural mortality, no valve migration, no moderate-severe paravalvular leak, and low transprosthetic gradients (residual mean gradient 8.2 ± 3.4 mmHg). There were no strokes, no in-hospital or 30-day mortality, and an incidence of in-hospital pacemaker implantation of 10%. Furthermore, measurement of the LIRA plane perimeter was highly reproducible between observers (r = 0.980; P < 0.001) and predictive of the post-procedural prosthetic valve perimeter on CT scanning (r = 0.981; P < 0.001). We confirm the feasibility of supra-annular sizing using the LIRA method in a large cohort of patients with high procedural success and good clinical outcomes at 30 days. Application of the LIRA method optimizes THV prosthesis sizing in patients with raphe-type BAV disease.

15.
Ann Thorac Surg ; 114(6): e465-e468, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35257676

RESUMEN

Exposure of anatomic landmarks is key in mitral valve repair. We report a technique to improve exposure of the mitral valve posterior leaflet during video-assisted procedures. It consists of a traction stitch placed on the leaflet free edges after triangular resection and through the anterior left atrial wall close to the mitral annulus. Gentle traction on this suture pulls the posterior leaflet on the plane of the mitral annulus to improve exposure and to expedite the reconstruction.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Técnicas de Sutura , Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos
16.
Am J Cardiol ; 171: 105-114, 2022 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-35317926

RESUMEN

Chronic kidney disease (CKD) is strongly related to outcomes in cardiovascular diseases. Limited data are available regarding the independent prognostic role of CKD after transcatheter mitral valve repair with MitraClip. We sought to evaluate the real impact of CKD in a large series of patients with heart failure (HF) and secondary mitral regurgitation (SMR) who underwent MitraClip treatment. The study included 565 patients with severe SMR from a multicenter international registry. Patients were stratified into 3 groups according to estimated glomerular filtration rate (eGFR) assessment before MitraClip implantation: normal eGFR (≥60 ml/min/1.73 m2) (n = 196), mild-to-moderate CKD (30 to 59 ml/min/1.73 m2) (n = 267), and severe CKD (<30 ml/min/1.73 m2) (n = 102). The primary end point was a composite of overall death and the first rehospitalization for HF, the secondary end points were overall death, cardiac death, and first rehospitalization for HF. CKD was present in about 2/3 of patients. At 5-year Kaplan-Meier analysis, primary clinical end point occurred in 60% of patients with normal eGFR, compared with 73% cases in patients with mild-to-moderate CKD and 91% in patients with severe CKD (p <0.001). Long-term overall death rate significantly decreased with increasing eGFR, and cardiac death and rehospitalization for HF rates. Multivariate Cox regression analysis identified severe CKD as the strongest independent predictor of adverse outcome (hazard ratio 2.136, 95% confidence interval 1.164 to 3.918, p = 0.014). In conclusion, CKD affected about 2/3 of patients who underwent MitraClip treatment for severe SMR, and it was a strong and independent predictor of 5-year adverse outcomes.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Insuficiencia Renal Crónica , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/epidemiología , Resultado del Tratamiento
17.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-35266511

RESUMEN

OBJECTIVES: This study aimed at assessing mid-term outcomes of patients undergoing isolated tricuspid valve (TV) surgery based on a preoperative baseline clinical and functional classification. METHODS: All patients treated with isolated TV repair or replacement from March 1997 to May 2020 at a single institution were retrospectively reviewed and assessed for mid-term postoperative outcome according to a novel classification [stages 1-5 related to the absence or presence and extent of right heart failure (RHF)]. Kaplan-Meier survival curves were used to estimate mid-term survival. Competing risk analysis for time to cardiac death and hospitalizations for RHF were also carried out. RESULTS: Among the 172 patients included, 129 (75%) underwent TV replacement and 43 (25%) TV repair. At follow-up (median 4.2 years [2.1-7.5]), there were 23 late deaths. At 5 years, overall survival was 100% in stage 2, 88 ± 4% in stage 3 and 60 ± 8% in stages 4-5 (P = 0.298 and P = 0.001, respectively). Cumulative incidence function of cardiac death at 5 years was 0%, 8.6 ± 3.76% and 13.2 ± 5% for stages 2, 3 and 4 and 5, respectively. At follow-up, cumulative incidence function of re-hospitalizations for RHF was 0% for stage 2, 20 ± 5% for stage 3 and 20 ± 6.7% for stages 4 and 5 (P = 0.118 and P = 0.039, respectively). CONCLUSIONS: Both short- and mid-term outcomes support early referral for surgery in isolated TV disease, with excellent survival at 5 years and no further hospitalizations for RHF.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Muerte , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología
19.
J Thorac Cardiovasc Surg ; 163(4): 1331-1332, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-32680637
20.
Can J Cardiol ; 38(3): 320-329, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34923063

RESUMEN

BACKGROUND: COAPT-trial entry criteria are useful to identify patients with better outcomes after transcatheter edge-to-edge repair (TEER). However, up to one-half of real-world patients with secondary mitral regurgitation (SMR) undergoing TEER do not meet these highly selective criteria and no study has formally investigated them. The aim of this study was to evaluate the predictors of good outcome after TEER in COAPT-ineligible patients. METHODS: All consecutive patients with SMR and heart failure (HF) treated with MitraClip at 3 European centres were retrospectively screened. The presence of at least 1 COAPT exclusion criterion was used to define a COAPT-ineligible profile, allowing the inclusion in the study population. Freedom from all-cause death or HF hospitalisation was evaluated at 2-year follow-up (primary end point). RESULTS: A total of 305 patients (47%) had a COAPT-ineligible profile. An overall 58% rate of all-cause death or HF hospitalisation was detected at 2 years. Patients with a single COAPT exclusion criterion experienced fewer adverse events than those with multiple criteria (55% vs 69%). At multivariable Cox regression analysis, New York Heart Association functional class II, younger age (< 75 years), lower serum creatinine (< 2 mg/dL), lower left ventricular end-diastolic volume (< 240 mL), and the absence of hemodynamic instability, atrial fibrillation, and chronic obstructive pulmonary disease were independently associated with good outcome. CONCLUSIONS: In this real-world series of patients with SMR undergoing TEER, a COAPT-ineligible profile was common. The presence of only 1 COAPT exclusion criterion or the absence of hemodynamic instability were associated with the most favourable outcomes.


Asunto(s)
Cateterismo Cardíaco , Determinación de la Elegibilidad/métodos , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/estadística & datos numéricos , Ecocardiografía/métodos , Diseño de Equipo , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Evaluación de Resultado en la Atención de Salud , Selección de Paciente , Índice de Severidad de la Enfermedad , Volumen Sistólico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...