Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Intervalo de año de publicación
1.
J Endod ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39094780

RESUMEN

INTRODUCTION: To assess the effect of combinations of two different endodontic sealers used in initial and endodontic retreatment on the bond strength of the secondary obturation and the penetrability of the sealers. METHODS: Forty-eight mandibular premolars were used, receiving standardized endodontic access and biomechanical preparation. Twenty-four teeth received AH Plus sealer (AHP) in primary obturation and the others received Bio-C Sealer (BCS). Retreatment protocol was performed with an R50 instrument. The samples were further subdivided into four groups (n = 12) based on the combination of primary/secondary obturation sealers: AHP/AHP; AHP/BCS; BCS/AHP; and BCS/BCS. Four samples from each subgroup received the addition of fluorophores to the sealer for penetrability analysis using laser scanning confocal fluorescence microscopy. The root portion on the 8 push-out samples was sectioned into 6 slices of 1.0 mm. Bond strength (BS) was assessed using a universal testing machine until displacement of the filling mass. Failure pattern was evaluated under a stereomicroscope (20× magnification). BS data were analyzed using two-way analysis of variance followed by Tukey's test (P < .05), and the association between the failure pattern and BS value was assessed using the chi-square test (P < .05). Penetrability was qualitatively evaluated. RESULTS: The highest BS values were observed in the AHP/AHP (4.54 ± 1.5 MPa) and BCS/AHP (5.00 ± 1.0 MPa) groups (P < .05), with a higher percentage of adhesive failures to the filling material for all groups. Laser scanning confocal fluorescence microscopy images indicated greater penetrability of AHP compared to BCS, both in initial treatment and retreatment. CONCLUSION: AHP sealer exhibited higher BS and greater penetrability compared to BCS sealer.

2.
Artículo en Inglés | MEDLINE | ID: mdl-37580223

RESUMEN

OBJECTIVE: The objective of this study was to evaluate 2-dimensional (2D) and 3D morphometric parameters of C-shaped root canals on cone beam computed tomography (CBCT) and microcomputed tomography (microCT) images using nanocomputed tomography (nanoCT) as the reference standard. STUDY DESIGN: Sixty mandibular molars with C-shaped canals were individually scanned using nanoCT and microCT. Cone beam computed tomography acquisitions were then performed with 4 CBCT systems, using high and standard resolutions. The 2D parameters of roundness and major and minor diameters were obtained in the cross sections of the root canals at 1, 2, and 3 mm from the root apex. The 3D parameters of surface area, volume, and structure model index were measured considering the entire extension of the root canals. Absolute error (AE) in measurement was calculated against the nanoCT values. Data were statistically analyzed with the Shapiro-Wilk test and analysis of variance (α = 0.05). RESULTS: No significant differences in AE were discovered for the 2D parameters among microCT and the CBCT scans. The AE values for the 3D parameters of volume and surface area were significantly smaller in microCT compared to all CBCT units (P < .05). Significantly lower AE values for surface area were observed in high resolution compared to standard resolution for all CBCT units (P < .05). Structure model index did not differ significantly among microCT and all CBCT protocols. CONCLUSIONS: Cone beam computed tomography images showed accuracy for evaluating 2D parameters and over- and underestimation for 3D parameters.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Cavidad Pulpar , Humanos , Cavidad Pulpar/diagnóstico por imagen , Microtomografía por Rayos X , Tomografía Computarizada de Haz Cónico/métodos , Diente Molar/diagnóstico por imagen , Raíz del Diente , Mandíbula/diagnóstico por imagen
3.
Braz Oral Res ; 37: e056, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37255076

RESUMEN

To investigate the influence of the remaining volume of a new intracanal medication based on bioceramic compounds on the bond strength (BS) and formation of an adhesive interface between calcium silicate-based and epoxy resin-based root canal sealers. For this purpose, the specimens were distributed according to the intracanal medication (n = 26): Bio-C Temp (BCT) and Ultracal XS (UXS). The roots were scanned in microCT, and after 7 days, the medication was removed. Then a new scan was performed to evaluate the volume of medication remaining. Subsequently, 40 specimens were redistributed into 2 subgroups (n = 10) and filled according to the sealer used: AH Plus (AHP) and Bio-C Sealer (BCS), to assess the bond strength by using the push-out test, and the adhesive interface by confocal laser fluorescence microscopy (CLSM) and scanning electron microscopy (SEM). The t test showed a smaller remainder of BCT (1.77 ± 0.86) compared with UXS (10.47 ± 5.78), irrespective of the root third evaluated. The BS showed that teeth with BCT + BCS had higher bond strength values (3.70 ± 1.22) when compared to the other groups: BCT + AHP (2.15 ± 1.07), UXS + BCS (3.18 ± 1.09) and UXS + AHP (2.11 ± 1.02) (p<0.001). The cervical third had higher BS when compared with the middle and apical thirds (p < 0.001), and higher number of adhesive failures. The adhesive interface in SEM and CLSM images showed better adaptation for the association between BCT + BCS. Intracanal medication and silicate-based endodontic sealer appeared to interact chemically by forming a biomineralizing layer, allowing for an increase in the bond strength and forming an adhesive interface between the materials, with no or less gap formation.


Asunto(s)
Recubrimiento Dental Adhesivo , Materiales de Obturación del Conducto Radicular , Materiales de Obturación del Conducto Radicular/química , Cavidad Pulpar , Dentina , Resinas Epoxi/química , Recubrimiento Dental Adhesivo/métodos , Ensayo de Materiales
4.
Braz. oral res. (Online) ; 37: e056, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1439745

RESUMEN

Abstract To investigate the influence of the remaining volume of a new intracanal medication based on bioceramic compounds on the bond strength (BS) and formation of an adhesive interface between calcium silicate-based and epoxy resin-based root canal sealers. For this purpose, the specimens were distributed according to the intracanal medication (n = 26): Bio-C Temp (BCT) and Ultracal XS (UXS). The roots were scanned in microCT, and after 7 days, the medication was removed. Then a new scan was performed to evaluate the volume of medication remaining. Subsequently, 40 specimens were redistributed into 2 subgroups (n = 10) and filled according to the sealer used: AH Plus (AHP) and Bio-C Sealer (BCS), to assess the bond strength by using the push-out test, and the adhesive interface by confocal laser fluorescence microscopy (CLSM) and scanning electron microscopy (SEM). The t test showed a smaller remainder of BCT (1.77 ± 0.86) compared with UXS (10.47 ± 5.78), irrespective of the root third evaluated. The BS showed that teeth with BCT + BCS had higher bond strength values (3.70 ± 1.22) when compared to the other groups: BCT + AHP (2.15 ± 1.07), UXS + BCS (3.18 ± 1.09) and UXS + AHP (2.11 ± 1.02) (p<0.001). The cervical third had higher BS when compared with the middle and apical thirds (p < 0.001), and higher number of adhesive failures. The adhesive interface in SEM and CLSM images showed better adaptation for the association between BCT + BCS. Intracanal medication and silicate-based endodontic sealer appeared to interact chemically by forming a biomineralizing layer, allowing for an increase in the bond strength and forming an adhesive interface between the materials, with no or less gap formation.

5.
Dent. press endod ; 9(2): 19-28, maio 2019. Ilus
Artículo en Portugués | BBO - Odontología, LILACS | ID: biblio-1024481

RESUMEN

Introdução: mesmo quando um tratamento endodôntico ou retratamento mais rigoroso é realizado, a periodontite apical pode persistir, levando à destruição do ligamento periodontal, cemento, osso alveolar e dentina. Nesses casos, o tratamento endodôntico cirúrgico, se realizado com o microscópio operatório (MO), ressecção mínima da raiz, retropreparo com pontas ultrassônicas e materiais para retrobturação biocompatíveis, pode alcançar mais de 90% de sucesso. Os procedimentos endodônticos cirúrgicos foram completamente transformados pela incorporação do MO, associado a novos recursos como aparelhos de ultrassom piezocirúrgico com pontas específicas para microcirurgia, microespelhos flexíveis, microexploradores, microcuretas endodônticas, microcondensadores e microinstrumentos para sutura. O MO pode otimizar todas as etapas de uma microcirurgia parendodôntica, incluindo o descolamento do retalho, a osteotomia, identificação do ápice radicular, apicectomia, remoção de tecido inflamatório, observação da superfície remanescente da raiz, retropreparo, obturação retrógrada e sutura. Objetivo: o objetivo do presente artigo é apresentar todos os passos da microcirurgia parendodôntica moderna e descrever os novos recursos disponíveis no mercado para melhorar a taxa de sucesso dessa modalidade. Conclusão: o uso de técnicas modernas de microcirurgia parendodôntica melhora significativamente as taxas de sucesso da terapia, quando comparada às técnicas tradicionais.


Asunto(s)
Humanos , Apicectomía , Periodontitis Periapical , Radiografía Dental , Tomografía Computarizada de Haz Cónico , Endodoncia
6.
Braz Oral Res ; 31: e72, 2017 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-28832718

RESUMEN

To assess the physicochemical properties of AH Plus, GuttaFlow 2, GuttaFlow BioSeal, and MM Seal, five samples of each root canal sealer were evaluated to determine their setting time (ST), dimensional change (DC), solubility (SL), flow (FL), and radiopacity (RD) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. The distilled and deionized water obtained from the SL test were subjected to atomic absorption spectrometry to observe the presence of Ca2+, K+, and Na+ ions. Statistical analysis was performed by using one-way ANOVA and Tukey-Kramer tests (p < 0.05). The following results were obtained: ST (min) (AH Plus 463.6 ± 13.22; GuttaFlow 2 24.35 ± 2.78; GuttaFlow Bioseal 17.4 ± 0.55; MM Seal 47.60 ± 4.39), DC (%) (AH Plus 0.06 ± 0.12; GuttaFlow 2 -26.06 ± 1.24; GuttaFlow Bioseal 2.10 ± 1.47; MM Seal 8.47 ± 2.41), SL (%) (AH Plus 0.41 ± 0.21; GuttaFlow 2 5.13 ± 4.11; GuttaFlow Bioseal 3.03 ± 1.05; MM Seal 0.94 ± 0.17), FL (mm) (AH Plus 36.42 ± 0.40; GuttaFlow 2 36.44 ± 0.05; GuttaFlow Bioseal 35.4 ± 0.03; MM Seal 52.75 ± 0.60), and RD (mmAl) (AH Plus 7.52 ± 1.59; GuttaFlow 2 6.85 ± 0.14; GuttaFlow Bioseal 7.02 ± 0.18; MM Seal 3.32 ± 0.90). ST, DC, SL, FL, and RD showed statistical differences among the root canal sealers (p < 0.05). As AH Plus showed the lowest DC and SL values (p < 0.05), the findings indicate that this sample is the only sealer conforming to ANSI/ADA standards.


Asunto(s)
Dimetilpolisiloxanos/química , Resinas Epoxi/química , Gutapercha/química , Materiales de Obturación del Conducto Radicular/química , Siliconas/química , Análisis de Varianza , Combinación de Medicamentos , Ensayo de Materiales , Valores de Referencia , Solubilidad , Espectrofotometría Atómica , Estadísticas no Paramétricas , Propiedades de Superficie , Factores de Tiempo
7.
Braz. oral res. (Online) ; 31: e72, 2017. tab
Artículo en Inglés | LILACS | ID: biblio-952078

RESUMEN

Abstract To assess the physicochemical properties of AH Plus, GuttaFlow 2, GuttaFlow BioSeal, and MM Seal, five samples of each root canal sealer were evaluated to determine their setting time (ST), dimensional change (DC), solubility (SL), flow (FL), and radiopacity (RD) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. The distilled and deionized water obtained from the SL test were subjected to atomic absorption spectrometry to observe the presence of Ca2+, K+, and Na+ ions. Statistical analysis was performed by using one-way ANOVA and Tukey-Kramer tests (p < 0.05). The following results were obtained: ST (min) (AH Plus 463.6 ± 13.22; GuttaFlow 2 24.35 ± 2.78; GuttaFlow Bioseal 17.4 ± 0.55; MM Seal 47.60 ± 4.39), DC (%) (AH Plus 0.06 ± 0.12; GuttaFlow 2 −26.06 ± 1.24; GuttaFlow Bioseal 2.10 ± 1.47; MM Seal 8.47 ± 2.41), SL (%) (AH Plus 0.41 ± 0.21; GuttaFlow 2 5.13 ± 4.11; GuttaFlow Bioseal 3.03 ± 1.05; MM Seal 0.94 ± 0.17), FL (mm) (AH Plus 36.42 ± 0.40; GuttaFlow 2 36.44 ± 0.05; GuttaFlow Bioseal 35.4 ± 0.03; MM Seal 52.75 ± 0.60), and RD (mmAl) (AH Plus 7.52 ± 1.59; GuttaFlow 2 6.85 ± 0.14; GuttaFlow Bioseal 7.02 ± 0.18; MM Seal 3.32 ± 0.90). ST, DC, SL, FL, and RD showed statistical differences among the root canal sealers (p < 0.05). As AH Plus showed the lowest DC and SL values (p < 0.05), the findings indicate that this sample is the only sealer conforming to ANSI/ADA standards.


Asunto(s)
Materiales de Obturación del Conducto Radicular/química , Siliconas/química , Dimetilpolisiloxanos/química , Resinas Epoxi/química , Gutapercha/química , Valores de Referencia , Solubilidad , Espectrofotometría Atómica , Propiedades de Superficie , Factores de Tiempo , Ensayo de Materiales , Análisis de Varianza , Estadísticas no Paramétricas , Combinación de Medicamentos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA