Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Children (Basel) ; 10(5)2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37238407

RESUMEN

Treatment options for hypoplastic borderline left ventricle (LV) are critically dependent on the development of the LV itself and include different types of univentricular palliation or biventricular repair performed at birth. Since hybrid palliation allows deferring major surgery to 4-6 months, in borderline cases, the decision can be postponed until the LV has expressed its growth potential. We aimed to evaluate anatomic modifications of borderline LV after hybrid palliation. We retrospectively reviewed data from 45 consecutive patients with hypoplastic LV who underwent hybrid palliation at birth between 2011 and 2015. Sixteen patients (mean weight 3.15 Kg) exhibited borderline LV and were considered for potential LV growth. After 5 months, five patients underwent univentricular palliation (Group 1), eight biventricular repairs (Group 2) and three died before surgery. Echocardiograms of Groups 1 and 2 were reviewed, comparing LV structures at birth and after 5 months. Although, at birth, all LV measurements were far below the normal limits, after 5 months, LV mass in Group 2 was almost normal, while in Group 1, no growth was evident. However, aortic root diameter and long axis ratio were significantly higher in Group 2 already at birth. Hybrid palliation can be positively considered as a "bridge-to-decision" for borderline LV. Echocardiography plays a key role in monitoring the growth of borderline LV.

2.
Interact Cardiovasc Thorac Surg ; 27(5): 761-764, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29860487

RESUMEN

Transcatheter creation or enlargement of an atrial septal defect has been used to promote adequate blood flow and mixing in some forms of congenital heart defects or as a relief valve in right or left atrial hypertension, resulting in better cardiac output and/or systemic saturation. We report a case of a 4-year-old male affected by complex congenital heart disease who was admitted for management of severe cyanosis following a staged pericardial fenestrated Fontan procedure. Transoesophageal echocardiogram showed a wide fenestration of 9 mm in size with a severely dilated pericardial Fontan system. To avoid a new surgical procedure and as part of a compassionate use programme, we decided to implant an atrial flow regulator device (4 mm in diameter) with percutaneous approach with the goal of reducing the right-to-left shunt and increasing the pulmonary flow. Preprocedural oxygen saturation was 75%, whereas after 2 months of follow-up, we observed a progressive increase of up to 95% with significant reduction in the pericardial Fontan system dimensions at echocardiography.


Asunto(s)
Cateterismo Cardíaco/métodos , Procedimiento de Fontan/métodos , Atrios Cardíacos/cirugía , Defectos del Tabique Interatrial/cirugía , Gasto Cardíaco/fisiología , Preescolar , Ecocardiografía , Atrios Cardíacos/diagnóstico por imagen , Defectos del Tabique Interatrial/diagnóstico , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...