Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
Injury ; 55(6): 111518, 2024 Jun.
Article En | MEDLINE | ID: mdl-38614834

INTRODUCTION: Post-operative pelvic & acetabular fixation patients are conventionally imaged using 3-view radiographs (AP, inlet and outlet). The efficacy of such radiographs is inconsistent due to technical difficulties capturing an adequate view, often necessitating repeat radiographs and therefore increasing radiation exposure. Radiographs can be difficult to interpret, limiting the assessment of fracture reduction and fixation, especially with respect to metalwork positioning around articular surfaces. Traditionally, post-operative pelvic & acetabular fixation patients undergo repeat 3-view radiographs post-operatively, at 6 weeks, followed by at 3, 6, 12, 18 and 24 months. We propose a new pathway, in which patients have one low-dose pelvic CT immediately post-operatively, followed by one radiograph (AP pelvis) at the same time points. METHODS: A new pelvic CT protocol was created to provide high quality 3D imaging whilst delivering a 5 times lower radiation dose (compared to normal pelvic CT). Data for all pelvic radiographs and CTs between January 2021 and March 2022 was exported. Using dose area product values, effective radiation dose and attributable lifetime cancer risk were calculated. RESULTS: There were 42 patients included in the analysis (age range 15 to 87).The average effective dose for the 3-view pelvic X-rays was 0.6mSv (range 0.2 to 2.8mSv), and 1.1mSv (range 0.5 to 2.2mSv) for the low-dose pelvic CT. Traditional 7 × 3-view post-operative radiographs: 7 × 0.6mSv = 4.2mSv (corresponding to 1 in 11,000 cancer risk) Low dose post-operative CT and 6 × 1-view radiographs: 1.1mSv + (6 × 0.6mSv / 3) = 2.3mSv (corresponding to 1 in 20,000 cancer risk) CONCLUSION: Low-dose CT scanning (in conjunction with 1-view radiographs) is an effective and safe imaging modality in the post-operative assessment of pelvic & acetabular fracture fixation, conferring a lower radiation burden, easier logistics, and higher quality images when compared to the traditional pathway of 3-view radiographs.


Acetabulum , Fracture Fixation, Internal , Fractures, Bone , Pelvic Bones , Radiation Dosage , Tomography, X-Ray Computed , Humans , Acetabulum/surgery , Acetabulum/diagnostic imaging , Acetabulum/injuries , Female , Male , Middle Aged , Adult , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Aged , Pelvic Bones/diagnostic imaging , Pelvic Bones/injuries , Pelvic Bones/surgery , Adolescent , Aged, 80 and over , Fracture Fixation, Internal/methods , Young Adult , Imaging, Three-Dimensional , Postoperative Care/methods , Retrospective Studies , Postoperative Period , Radiation Exposure
2.
Cancer Biother Radiopharm ; 35(7): 530-539, 2020 Sep.
Article En | MEDLINE | ID: mdl-32429699

Introduction: Thorium-227 is an alpha-emitting radioisotope with potential therapeutic applications in targeted alpha therapy. Thorium-227 decays to Radium-223, which may have an independent biodistribution to that of the parent Thorium-227 radiopharmaceutical. Quantitative in vivo imaging with sodium iodide (NaI) detectors is challenging due to cross-talk between neighboring γ-photopeaks as well as scattered γ-photons. The aim of this work was to validate the use of a spectral analysis technique to estimate the activity of each isotope within a region of interest applied to a pair of conjugate view planar acquisitions, acquired at multiple energy windows. Methods: Energy spectra per unit activity arising from unscattered Thorium-227 photons and Radium-223 photons as well as from scattered photons were modeled. These spectra were scaled until the combination of these component spectra resulted in the closest match to the measured data in four energy windows. Results: Measured estimates of activity followed the known decay curves in phantoms representative of a human torso. The mean errors in estimating Thorium-227 and Radium-223 were 5.1% (range -8.0% to 40.0%) and 3.4% (range -50.0% to 48.7%), respectively. The differences between the integrals of the theoretical and estimated time activity curve were <10% for both Thorium-227 and Radium-223. Conclusion: γ-camera quantification of Thorium-227 and Radium-223 can be achieved by using multiple energy window acquisitions.


Models, Theoretical , Radiopharmaceuticals/pharmacokinetics , Radium/pharmacokinetics , Thorium/pharmacokinetics , Gamma Cameras , Humans , Models, Anatomic , Phantoms, Imaging , Radiometry/methods , Spectrometry, Gamma/instrumentation , Spectrometry, Gamma/methods , Tissue Distribution , Torso/diagnostic imaging
...