Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JACC Cardiovasc Interv ; 10(9): 879-888, 2017 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-28473110

RESUMEN

OBJECTIVES: This study sought to evaluate the incidence and clinical effect of coronary chronic total occlusions (CTOs) in patients with ischemic cardiomyopathy receiving an implantable cardioverter-defibrillator (ICD) for secondary prevention of sudden cardiac death (SCD). BACKGROUND: CTOs are common in patients with ischemic cardiomyopathy, which is the major cause of SCD. However, the impact of CTO in SCD survivors receiving an ICD is unknown. METHODS: A total of 425 patients who had survived an episode of ventricular arrhythmias and underwent ICD implantation for secondary prevention in 8 centers were included. Coronary angiogram, CTO angiographic characteristics, and ventricular arrhythmia pattern were centrally analyzed. Primary and secondary endpoints were appropriate ICD therapies and mortality during a median follow-up of 4.1 years, according to the presence of CTO in the baseline angiogram. RESULTS: Appropriate ICD therapies were higher in patients with CTO (51.7% vs. 36.3%; p = 0.001 at 4 years). Left ventricular ejection fraction (LVEF) (p = 0.015) and CTO (p = 0.001) were independent predictors of appropriate ICD therapy. Ventricular arrhythmia onset was associated to a shorter coupling interval and lower prematurity index in CTO patients. Defibrillator therapies were independently associated with worse LVEF (p = 0.046) and renal dysfunction (p = 0.023) among patients with CTO, and a tendency was observed in patients with better collateral flow (p = 0.093). Patients with poorer renal function (p = 0.029), LVEF (p = 0.041), and CTO (p = 0.033) experienced higher mortality rate. CONCLUSIONS: Among ICD recipients for secondary prevention of SCD, coronary CTO conferred a higher risk of VA recurrence and mortality in long-term follow-up. Angiographic and VA patterns could provide insights into the mechanisms of SCD and may have implications for the use of interventions designed to limit ICD shocks in this high-risk population.


Asunto(s)
Arritmias Cardíacas/terapia , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Técnicas Electrofisiológicas Cardíacas , Prevención Secundaria/instrumentación , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Enfermedad Crónica , Oclusión Coronaria/mortalidad , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Europa (Continente)/epidemiología , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA