1.
Int J Rob Res ; 40(6-7): 923-938, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34334877

RESUMEN

Continuum manipulators, inspired by nature, have drawn significant interest within the robotics community. They can facilitate motion within complex environments where traditional rigid robots may be ineffective, while maintaining a reasonable degree of precision. Soft continuum manipulators have emerged as a growing subfield of continuum robotics, with promise for applications requiring high compliance, including certain medical procedures. This has driven demand for new control schemes designed to precisely control these highly flexible manipulators, whose kinematics may be sensitive to external loads, such as gravity. This article presents one such approach, utilizing a rapidly computed kinematic model based on Cosserat rod theory, coupled with sensor feedback to facilitate closed-loop control, for a soft continuum manipulator under tip follower actuation and external loading. This approach is suited to soft manipulators undergoing quasi-static deployment, where actuators apply a follower wrench (i.e., one that is in a constant body frame direction regardless of robot configuration) anywhere along the continuum structure, as can be done in water-jet propulsion. In this article we apply the framework specifically to a tip actuated soft continuum manipulator. The proposed control scheme employs both actuator feedback and pose feedback. The actuator feedback is utilized to both regulate the follower load and to compensate for non-linearities of the actuation system that can introduce kinematic model error. Pose feedback is required to maintain accurate path following. Experimental results demonstrate successful path following with the closed-loop control scheme, with significant performance improvements gained through the use of sensor feedback when compared with the open-loop case.

2.
Endosc Int Open ; 9(2): E171-E180, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33532555

RESUMEN

Background and study aims Colonoscopy is a technically challenging procedure that requires extensive training to minimize discomfort and avoid trauma due to its drive mechanism. Our academic team developed a magnetic flexible endoscope (MFE) actuated by magnetic coupling under supervisory robotic control to enable a front-pull maneuvering mechanism, with a motion controller user interface, to minimize colon wall stress and potentially reduce the learning curve. We aimed to evaluate this learning curve and understand the user experience. Methods Five novices (no endoscopy experience), five experienced endoscopists, and five experienced MFE users each performed 40 trials on a model colon using 1:1 block randomization between a pediatric colonoscope (PCF) and the MFE. Cecal intubation (CI) success, time to cecum, and user experience (NASA task load index) were measured. Learning curves were determined by the number of trials needed to reach minimum and average proficiency-defined as the slowest average CI time by an experienced user and the average CI time by all experienced users, respectively. Results MFE minimum proficiency was achieved by all five novices (median 3.92 trials) and five experienced endoscopists (median 2.65 trials). MFE average proficiency was achieved by four novices (median 14.21 trials) and four experienced endoscopists (median 7.00 trials). PCF minimum and average proficiency levels were achieved by only one novice. Novices' perceived workload with the MFE significantly improved after obtaining minimum proficiency. Conclusions The MFE has a short learning curve for users with no prior experience-requiring relatively few attempts to reach proficiency and at a reduced perceived workload.

3.
IEEE ASME Trans Mechatron ; 25(2): 1005-1015, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32355440

RESUMEN

With significant research focused on integrating robotics into medical devices, sanitary control of pressurizing fluids in a precise, accurate and customizable way is highly desirable. Current sanitary flow control methods include pinch valves which clamp the pressure line locally to restrict fluid flow; resulting in damage and variable flow characteristics over time. This paper presents a sanitary compression valve based on an eccentric clamping mechanism. The proposed valve distributes clamping forces over a larger area, thereby reducing the plastic deformation and associated influence on flow characteristic. Using the proposed valve, significant reductions in plastic deformation (up to 96%) and flow-rate error (up to 98%) were found, when compared with a standard pinch valve. Additionally, an optimization strategy presents a method for improving linearity and resolution over the working range to suit specific control applications. The valve efficacy has been evaluated through controlled testing of a water jet propelled low-cost endoscopic device. In this case, use of the optimized valve shows a reduction in the average orientation error and its variation, resulting in smoother movement of the endoscopic tip when compared to alternative wet and dry valve solutions. The presented valve offers a customizable solution for sanitary control of fluid driven actuators.

4.
Gastrointest Endosc ; 92(3): 770-775, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32334018

RESUMEN

BACKGROUND AND AIMS: Endoscopic intervention has emerged as a first-line option for management of symptomatic pancreatic necrosis, yet endoscopic debridement is limited by the lack of dedicated endoscopic tools intended for this purpose. The objectives of this study were to design and build a prototype necrosectomy device compatible for use with a flexible endoscope and capable of selective tissue fragmentation, and to test the prototype in benchtop and porcine models. METHODS: A novel prototype, named the waterjet necrosectomy device (WAND), was designed and developed, consisting of a single-use disposable endoscopic waterjet instrument capable of waterjet selection and independent tip articulation while fitting through a 2.8-mm working channel of a standard adult upper GI endoscope. Benchtop, ex vivo, and in vivo (porcine) testing was performed in the initial stages of investigation. RESULTS: The WAND was capable of delivering a continuous waterjet force with a surface pressure of 0.72 bar at a flow rate of 0.37 L/minute. In phase 1 of testing, the WAND was able to achieve complete fragmentation of gelatin as a surrogate for pancreatic necrosis in benchtop testing. In phase 2 of testing, the WAND was able to achieve complete fragmentation of freshly explanted human pancreatic necrosis. In phase 3 of testing for safety in fresh necropsy swine, use of the WAND resulted in no significant tissue trauma, even when irrigation was applied at closer proximity and for more extended duration than would be anticipated in clinical use. CONCLUSION: The WAND prototype delivers irrigation capable of fragmenting necrotic debris ex vivo and avoiding trauma to healthy nontarget tissue. Planning is underway for first-in-human studies to assess the efficacy and safety of the WAND for endoscopic pancreatic necrosectomy.


Asunto(s)
Pancreatitis Aguda Necrotizante , Animales , Desbridamiento , Modelos Animales de Enfermedad , Endoscopía del Sistema Digestivo , Pancreatitis Aguda Necrotizante/cirugía , Porcinos
5.
IEEE Robot Autom Lett ; 5(2): 2642-2649, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32123751

RESUMEN

Continuum manipulators are flexible robots which undergo continuous deformation as they are actuated. To describe the elastic deformation of such robots, kinematic models have been developed and successfully applied to a large variety of designs and to various levels of constitutive stiffness. Independent of the design, kinematic models need to be calibrated to best describe the deformation of the manipulator. However, even after calibration, unmodeled effects such as friction, nonlinear elastic and/or spatially varying material properties as well as manufacturing imprecision reduce the accuracy of these models. In this paper, we present a method for improving the accuracy of kinematic models of continuum manipulators through the incorporation of orientation sensor feedback. We achieve this through the use of a "disturbance wrench", which is used to compensate for these unmodeled effects, and is continuously estimated based on orientation sensor feedback as the robot moves through its workspace. The presented method is applied to the HydroJet, a waterjet-actuated soft continuum manipulator, and shows an average of 40% reduction in root mean square position and orientation error in the two most common types of kinematic models for continuum manipulators, a Cosserat rod model and a pseudo-rigid body model.

SELECCIÓN DE REFERENCIAS