1.
Pacing Clin Electrophysiol ; 47(5): 635-641, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38552167

RESUMEN

BACKGROUND: The stretching of the lead caused by somatic growth may lead to complications (dislodgement, fracture, failure) of transvenous leads implanted in pediatric patients. Atrial loop and absorbable ligatures may prevent it. Periodical lead advancement with lead pushing from the pocket may be an option to growth-induced stretching. Our aim was to analyze retrospectively the outcome of periodical transvenous lead advancement in children with pacemaker (PM). METHODS: A procedure of lead advancement was performed in patients with a single-chamber PM implanted for isolated congenital complete atrioventricular block or sinus node dysfunction with growth-induced lead straightening/stretching. The PM pocket was opened, the lead was released from subcutaneous adherences and was gently advanced to shape again a loop/semi-loop in the atrium without dislodging the tip. Lead data (threshold, sensing, impedance) were compared before and after the procedure. Data are described as median (25th-75th centiles). RESULTS: 14 patients with 13 VVIR and 1 AAIR PM implanted at 6.8 (5.9-8.0) years of age, 23 (19-26) kg, 118 (108-124) cm, underwent 30 advancement procedures, 1.5 (1.0-2.3) per patient, during follow-up [45 (35-63) months]. Delta between procedures was: 18 (14-25) months, 11 (7-13) cm, 6 (4-9) kg; 90% of leads were successfully advanced without complications. Three unsuccessful procedures occurred with longer times [30 (14-37) months]. Electrical lead parameters did not show significant differences pre-/post-procedures. CONCLUSION: the advancement of transvenous leads in children seems safe and effective. This procedure may be another possible choice to preserve transvenous lead position and function until growth has completed.


Asunto(s)
Marcapaso Artificial , Humanos , Masculino , Femenino , Estudios Retrospectivos , Niño , Preescolar , Electrodos Implantados , Bloqueo Atrioventricular/terapia , Síndrome del Seno Enfermo/terapia
2.
Europace ; 25(4): 1482-1490, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794445

RESUMEN

AIMS: In congenitally corrected transposition of the great arteries (CCTGA) the right ventricle (RV) is systemic. Atrioventricular block (AVB) and systolic dysfunction are frequently observed. Permanent pacing of the subpulmonary left ventricle (LV) may worsen RV dysfunction. The aim of this study was to seek out if LV conduction system pacing (LVCSP) guided by three-dimensional-electroanatomic mapping systems (3D-EAMs) can preserve RV systolic function in paediatric CCTGA patients with AVB. METHODS AND RESULTS: Retrospective analysis of CCTGA patients who underwent 3D-EAM-guided LVCSP. Three-dimensional-pacing map guided lead implantation towards septal sites with narrower paced QRS. Electrocardiograms (ECGs), echocardiograms, and lead parameters (threshold, sensing, and impedance) were compared at baseline (pre-implantation) and at 1-year follow-up. Right ventricle function was evaluated by 3D ejection fraction (EF), fractional area change (FAC), RV global longitudinal strain (GLS). Data are reported as median (25th-75th centiles). Seven CCTGA patients aged 15 (9-17) years, with complete/advanced AVB (4 with prior epicardial pacing), underwent 3D-guided LVCSP (5 DDD, 2 VVIR). Baseline echocardiographic parameters were impaired in most patients. No acute/chronic complications occurred. Ventricular pacing was >90%. At 1-year follow-up QRS duration showed no significant changes compared with baseline; however, QRS duration shortened in comparison with prior epicardial pacing. Lead parameters remained acceptable despite ventricular threshold increased. Systemic RV function was preserved: FAC and GLS improved significantly, and all patients showed normal RV EF (>45%). CONCLUSION: Three-dimensional-EAM-guided LVCSP preserved RV systolic function in paediatric patients with CCTGA and AVB after short-term follow-up.


Asunto(s)
Bloqueo Atrioventricular , Transposición de los Grandes Vasos , Humanos , Niño , Transposición Congénitamente Corregida de las Grandes Arterias/complicaciones , Transposición de los Grandes Vasos/complicaciones , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/terapia , Estudios Retrospectivos , Sistema de Conducción Cardíaco , Ventrículos Cardíacos/diagnóstico por imagen , Estimulación Cardíaca Artificial/métodos
3.
Cardiol Young ; 33(5): 760-765, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35673795

RESUMEN

BACKGROUND: Permanent pacing in children with isolated congenital complete atrioventricular block may cause left ventricular dysfunction. To prevent it, alternative pacing sites have been proposed: left ventricular epicardial or selective right ventricular endocardial pacing. AIMS: To compare the functional outcome (left ventricular systolic function and synchrony) in paediatric patients with congenital complete atrioventricular block and left ventricular apical epicardial or right ventricular transvenous mid-septal pacing. METHODS: Retrospective study. Epicardial leads were implanted by standard surgical technique, transvenous leads by 3D electroanatomic mapping systems. 3D mapping acquired 3D right ventricular local pacing map and defined the narrowest paced QRS site. 3D mapping guided screw-in bipolar leads on that ventricular site. Electrocardiogram (ECG) (QRS duration) and echocardiographic data (synchrony: interventricular mechanical delay, septal to posterior wall motion delay, systolic dyssynchrony index; contractility: global longitudinal strain, ejection fraction) were recorded. Data are reported as median [interquartile ranges]. p < 0.05 was significant. RESULTS: There were 19 transvenous systems (age 8.8 [6-14] years; right ventricular mid-septum) and 17 epicardial systems (0.04 [0.001-0.6] years; left ventricular apex). Post-implantation QRS significantly widened either in endocardial or in epicardial patients. Most patients reached 4-year follow-up. One-year and 4-year ejection fraction and global longitudinal strain were mostly within normal limits and did not show significant differences between the two groups and between the same endocardial/epicardial group. Synchrony parameters were within normal limits in the two groups. CONCLUSIONS: Left ventricular apical epicardial pacing and 3D mapping-guided right ventricular mid-septal pacing preserved left ventricular contractility and synchrony in children and adolescents with congenital complete atrioventricular block at short-/mid-term follow-up, without relevant significant differences between the two groups.


Asunto(s)
Bloqueo Atrioventricular , Estimulación Cardíaca Artificial , Adolescente , Humanos , Niño , Bloqueo Atrioventricular/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Función Ventricular Izquierda
4.
Biology (Basel) ; 11(10)2022 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-36290378

RESUMEN

MIS-C is a multisystem inflammatory syndrome that is characterized by multi-organ failure and cardiac involvement. The aim of this study was to describe the long-term cardiovascular outcome in a cohort of MIS-C pediatric patients, who were admitted to two Italian Pediatric Referral Centers. Sixty-seven patients (mean age 8.7 ± 4.7 years, male 60%) were included; 65 (97%) of them showed cardiac involvement. All of the patients completed one month of the follow-up, and 47% completed 1 year of it. ECG abnormalities were present in 65% of them, arrhythmias were present in 9% of them during an acute phase and it disappeared at the point of discharge or later. Pericarditis were detected in 66% of them and disappeared after 6 months. Coronaritis was observed in 35% of the children during an acute phase, and there were no more instances at the 1-year point. An LV dysfunction was present in 65% of the patients at the beginning of the study, with them having a full recovery at the point of discharge and thereafter. Elevated values of the NTproBNP and hsTp were initially detected, which progressively decreased and normalized at the points of discharge and FU. The CMR at the point of FU, there was a presence of long-term myocardial scars in 50% of the patients that were tested. No deaths that were caused by MIS-C during the FU were recorded. Cardiac involvement in MIS-C patients is almost the rule, but the patients' clinical course was satisfactory, and no additional events or sequelae were observed apart from there being long-term myocardial scars in 50% of the patients that underwent CMR.

5.
J Cardiovasc Dev Dis ; 9(2)2022 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-35200687

RESUMEN

BACKGROUND: Pediatric patients with cardiomyopathies are at risk of malignant arrhythmias and sudden cardiac death (SCD). An ICD may prevent SCD. The aim of this study was to evaluate ICD implantation outcomes, and to compare transvenous and subcutaneous ICDs (S-ICDs) implanted in pediatric patients with cardiomyopathies. METHODS: The study is single center and retrospective, and includes pediatric patients with cardiomyopathies who required ICD implantation (2010-2021). Outcomes were recorded for appropriate/inappropriate ICD therapy and surgical complications. Transvenous ICD and S-ICD were compared. Data are presented as median values (25th-75th centiles). RESULTS: Forty-four patients with cardiomyopathies (hypertrophic 39%, arrhythmogenic 32%, dilated 27%, and restrictive 2%) underwent transvenous (52%) and S-ICD (48%) implantation at 14 (12-17) years of age, mostly for primary prevention (73%). The follow-up period was 29 (14-60) months. Appropriate ICD therapies were delivered in 25% of patients, without defibrillation failures. Lower age at implantation and secondary prevention were significant risk factors for malignant ventricular arrhythmias that required appropriate ICD therapies. ICD-related complications were surgical complications (18%) and inappropriate shocks (7%). No significant differences in outcomes were recorded, either when comparing transvenous and S-ICD or comparing the different cardiomyopathies. CONCLUSIONS: In pediatric patients with cardiomyopathy, ICD therapy is effective, with a low rate of inappropriate shocks. Neither ICD type (transvenous and S-ICDs) nor the cardiomyopathies subgroup revealed divergent outcomes.

6.
Rev Cardiovasc Med ; 23(1): 27, 2022 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-35092219

RESUMEN

BACKGROUND: Remote monitoring-enabled insertable cardiac monitors (ICMs) are useful tools for arrhythmias and symptom management. This study sought to evaluate the outcome of ICM implantation in a large, heterogeneous cohort of pediatric and young adult patients. METHODS: Single centre, retrospective analysis of patients who underwent ICM implantation in 2010-2019. Patients were analysed according to age, symptoms, arrhythmias and underlying heart disease. RESULTS: A total of 200 consecutive patients (58% male), aged 11.5 ± 5.8 years at ICM implantation, were included. Follow-up was 31 ± 18 months. Electrophysiologic study (EPS) was initially performed in 123 patients and was negative in 85%. Patients had no heart disease (57.5%), congenital heart defects (21%), channelopathies (14.5%), cardiomyopathies/heart tumors (8%). The commonest symptoms were syncope/presyncope (45.5%) and palpitations (12.5%). A definite diagnosis was made in 63% of patients (positive diagnosis in 25%, negative in 38%) after 8 (2-19) months of monitoring. EPS results and the presence/absence of an arrhythmia before ICM implantation had no impact on the diagnostic yield. Symptomatic patients as well as patients without structural heart disease showed higher diagnostic yield. Patients with a positive diagnosis underwent pacemaker/implantable cardioverter-defibrillator implantation (13%), pharmacological treatment (10.5%), or catheter ablation (1.5%). CONCLUSIONS: In a large cohort of 200 children and young adults, ICMs with remote monitoring showed a high diagnostic yield (63%), especially in symptomatic patients and in patients without structural heart disease.


Asunto(s)
Arritmias Cardíacas , Cardiopatías Congénitas , Adolescente , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Niño , Preescolar , Femenino , Humanos , Masculino , Estudios Retrospectivos , Síncope/diagnóstico , Síncope/terapia , Adulto Joven
7.
J Interv Card Electrophysiol ; 63(3): 621-628, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34697756

RESUMEN

PURPOSE: Different authors have described three-dimensional (3D) voltage mapping of the Koch's triangle (KT) in order to find low-voltage bridges (LVB) as targets for a successful transcatheter ablation (TCA) of the slow pathway (SP) in children. Recently, the Advisor High Density (HD) Grid™ mapping catheter was introduced as new multipolar catheter for HD mapping. The aim of the study was to describe our preliminary experience with the use of HD Grid™ catheter in LVB and electrophysiologically guided cryoablation of SP in children. METHODS: Twenty-one children (mean age 13±3 years) with atrioventricular nodal re-entrant tachycardia (AVNRT) underwent cryoablation of SP guided by voltage HD mapping of the KT using HD Grid™ catheter. In order to better highlight the differences with conventional mapping, point collection was performed in each patient with this new multipolar catheter and with a quadripolar catheter. RESULTS: The conventional mapping collected 871±262 points and used 211±80 points in 887±275 s, whereas HD mapping collected 7468±2947 points, using 604±165 points in 513±181 s (p<0.001). Moreover, the LVB area mapped with HD Grid™ was about one-half smaller and clearly delineated. Cryoablation acute success rate was 100%. Overall median fluoroscopy exposure was 0.08 (0.01-5.42) µGy/m2, with a median fluoroscopy time of 0.1 (0.0-0.6) min. During the follow-up (4.8 ± 3.7 months), there were no recurrences. No complications occurred. CONCLUSIONS: Our preliminary experience shows that HD mapping is faster and offers higher spatial resolution and definition. Procedural time can be reduced maintaining the TCA safe, with reduced fluoroscopy use and success.


Asunto(s)
Ablación por Catéter , Criocirugía , Taquicardia por Reentrada en el Nodo Atrioventricular , Adolescente , Niño , Criocirugía/métodos , Humanos , Datos Preliminares , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico por imagen , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...