J Neurosurg ; : 1-8, 2024 May 03.
Article En | MEDLINE | ID: mdl-38701528

OBJECTIVE: This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS: A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS: The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS: The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.

2.
Eur Stroke J ; : 23969873241249295, 2024 May 10.
Article En | MEDLINE | ID: mdl-38726983

BACKGROUND: Stroke remains a major health concern globally, with oral anticoagulants widely prescribed for stroke prevention. The efficacy and safety of mechanical thrombectomy (MT) in anticoagulated patients with distal medium vessel occlusions (DMVO) are not well understood. METHODS: This retrospective analysis involved 1282 acute ischemic stroke (AIS) patients who underwent MT in 37 centers across North America, Asia, and Europe from September 2017 to July 2023. Data on demographics, clinical presentation, treatment specifics, and outcomes were collected. The primary outcomes were functional outcomes at 90 days post-MT, measured by modified Rankin Scale (mRS) scores. Secondary outcomes included reperfusion rates, mortality, and hemorrhagic complications. RESULTS: Of the patients, 223 (34%) were on anticoagulation therapy. Anticoagulated patients were older (median age 78 vs 74 years; p < 0.001) and had a higher prevalence of atrial fibrillation (77% vs 26%; p < 0.001). Their baseline National Institutes of Health Stroke Scale (NIHSS) scores were also higher (median 12 vs 9; p = 0.002). Before propensity score matching (PSM), anticoagulated patients had similar rates of favorable 90-day outcomes (mRS 0-1: 30% vs 37%, p = 0.1; mRS 0-2: 47% vs 50%, p = 0.41) but higher mortality (26% vs 17%, p = 0.008). After PSM, there were no significant differences in outcomes between the two groups. CONCLUSION: Anticoagulated patients undergoing MT for AIS due to DMVO did not show significant differences in 90-day mRS outcomes, reperfusion, or hemorrhage compared to non-anticoagulated patients after adjustment for covariates.

3.
J Neurointerv Surg ; 2024 May 02.
Article En | MEDLINE | ID: mdl-38697807

BACKGROUND: Pulsatile tinnitus (PT) can be a disabling clinical condition, which may be caused by a sigmoid/transverse sinus stenosis (STSS). Intracranial venous stenting with off-label carotid or peripheral venous stents has been used successfully to treat this condition. We present the results of a cohort of patients presenting with PT treated with a novel, dedicated, braided stent for the endovascular treatment of STSS. METHODS: Twelve patients presenting with PT and associated STSS were treated at our institution (December 2022-June 2023). All clinical and procedural variables were prospectively collected. We used the Tinnitus Function Index (TFI) and the Tinnitus Handicap Inventory (THI) scores to assess the impact of PT on quality of life before and after the treatment (mean follow-up: 10.3 months). RESULTS: Twelve women (mean age: 44±16.5 years) presenting with PT and STSS were treated. Mean pretreatment TFI/THI scores were 78.8/77. The BosStent was successfully deployed in all patients. We experienced no intraprocedural/postoperative complications. Intra-stent angioplasty was performed in three cases. All patients reported a complete resolution of PT symptoms within 1 month and remained stable and PT-free at the last follow-up (mean posttreatment TFI/THI score: 7.1/5, p<0001). CONCLUSIONS: The BosStent was successfully used in a cohort of patients with PT without any intraprocedural complications. All the patients experienced a complete resolution of PT symptoms after 1 month, which was stable during the follow-up period. Further studies with larger populations will be necessary to investigate the safety and effectiveness of this novel stent for the treatment of PT with STSS.

4.
Neurosurgery ; 2024 Apr 18.
Article En | MEDLINE | ID: mdl-38634693

BACKGROUND AND OBJECTIVES: Dual antiplatelet therapy (DAPT) is necessary to minimize the risk of periprocedural thromboembolic complications associated with aneurysm embolization using pipeline embolization device (PED). We aimed to assess the impact of platelet function testing (PFT) on reducing periprocedural thromboembolic complications associated with PED flow diversion in patients receiving aspirin and clopidogrel. METHODS: Patients with unruptured intracranial aneurysms requiring PED flow diversion were identified from 13 centers for retrospective evaluation. Clinical variables including the results of PFT before treatment, periprocedural DAPT regimen, and intracranial complications occurring within 72 h of embolization were identified. Complication rates were compared between PFT and non-PFT groups. Differences between groups were tested for statistical significance using the Wilcoxon rank sum, Fisher exact, or χ 2 tests. A P -value <.05 was statistically significant. RESULTS: 580 patients underwent PED embolization with 262 patients dichotomized to the PFT group and 318 patients to the non-PFT group. 13.7% of PFT group patients were clopidogrel nonresponders requiring changes in their pre-embolization DAPT regimen. Five percentage of PFT group [2.8%, 8.5%] patients experienced thromboembolic complications vs 1.6% of patients in the non-PFT group [0.6%, 3.8%] ( P = .019). Two (15.4%) PFT group patients with thromboembolic complications experienced permanent neurological disability vs 4 (80%) non-PFT group patients. 3.7% of PFT group patients [1.5%, 8.2%] and 3.5% [1.8%, 6.3%] of non-PFT group patients experienced hemorrhagic intracranial complications ( P > .9). CONCLUSION: Preprocedural PFT before PED treatment of intracranial aneurysms in patients premedicated with an aspirin and clopidogrel DAPT regimen may not be necessary to significantly reduce the risk of procedure-related intracranial complications.

5.
Clin Neuroradiol ; 2024 Apr 30.
Article En | MEDLINE | ID: mdl-38687365

BACKGROUND: Optimal anesthetic strategy for the endovascular treatment of stroke is still under debate. Despite scarce data concerning anesthetic management for medium and distal vessel occlusions (MeVOs) some centers empirically support a general anesthesia (GA) strategy in these patients. METHODS: We conducted an international retrospective study of MeVO cases. A propensity score matching algorithm was used to mitigate potential differences across patients undergoing GA and conscious sedation (CS). Comparisons in clinical and safety outcomes were performed between the two study groups GA and CS. The favourable outcome was defined as a modified Rankin Scale (mRS) 0-2 at 90 days. Safety outcomes were 90-days mortality and symptomatic intracranial hemorrhage (sICH). Predictors of a favourable outcome and sICH were evaluated with backward logistic regression. RESULTS: After propensity score matching 668 patients were included in the CS and 264 patients in the GA group. In the matched cohort, either strategy CS or GA resulted in similar rates of good functional outcomes (50.1% vs. 48.4%), and successful recanalization (89.4% vs. 90.2%). The GA group had higher rates of 90-day mortality (22.6% vs. 16.5%, p < 0.041) and sICH (4.2% vs. 0.9%, p = 0.001) compared to the CS group. Backward logistic regression did not identify GA vs CS as a predictor of good functional outcome (OR for GA vs CS = 0.95 (0.67-1.35)), but GA remained a significant predictor of sICH (OR = 5.32, 95% CI 1.92-14.72). CONCLUSION: Anaesthetic strategy in MeVOs does not influence favorable outcomes or final successful recanalization rates, however, GA may be associated with an increased risk of sICH and mortality.

6.
Neurosurg Rev ; 47(1): 116, 2024 Mar 14.
Article En | MEDLINE | ID: mdl-38483647

BACKGROUND: The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. METHODS: A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. RESULTS: Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). CONCLUSION: The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.


Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Treatment Outcome , Intracranial Aneurysm/surgery , Intracranial Aneurysm/etiology , Embolization, Therapeutic/adverse effects , Propensity Score , Retrospective Studies , Cohort Studies , Endovascular Procedures/adverse effects
7.
Eur Stroke J ; 9(2): 328-337, 2024 Jun.
Article En | MEDLINE | ID: mdl-38409796

BACKGROUND: Mechanical thrombectomy (MT) has revolutionized the treatment of acute ischemic stroke (AIS) due to large vessel occlusion (LVO), but its efficacy and safety in medium vessel occlusion (MeVO) remain less explored. This multicenter, retrospective study aims to investigate the incidence and clinical outcomes of vessel perforations (confirmed by extravasation during an angiographic series) during MT for AIS caused by MeVO. METHODS: Data were collected from 37 academic centers across North America, Asia, and Europe between September 2017 and July 2021. A total of 1373 AIS patients with MeVO underwent MT. Baseline characteristics, procedural details, and clinical outcomes were analyzed. RESULTS: The incidence of vessel perforation was 4.8% (66/1373). Notably, our analysis indicates variations in perforation rates across different arterial segments: 8.9% in M3 segments, 4.3% in M2 segments, and 8.3% in A2 segments (p = 0.612). Patients with perforation had significantly worse outcomes, with lower rates of favorable angiographic outcomes (TICI 2c-3: 23% vs 58.9%, p < 0.001; TICI 2b-3: 56.5% vs 88.3%, p < 0.001). Functional outcomes were also worse in the perforation group (mRS 0-1 at 3 months: 22.7% vs 36.6%, p = 0.031; mRS 0-2 at 3 months: 28.8% vs 53.9%, p < 0.001). Mortality was higher in the perforation group (30.3% vs 16.8%, p = 0.008). CONCLUSION: This study reveals that while the occurrence of vessel perforation in MT for AIS due to MeVO is relatively rare, it is associated with poor functional outcomes and higher mortality. The findings highlight the need for increased caution and specialized training in performing MT for MeVO. Further prospective research is required for risk mitigation strategies.


Ischemic Stroke , Thrombectomy , Humans , Ischemic Stroke/surgery , Ischemic Stroke/epidemiology , Ischemic Stroke/therapy , Male , Retrospective Studies , Female , Aged , Middle Aged , Incidence , Thrombectomy/adverse effects , Thrombectomy/methods , Treatment Outcome , Aged, 80 and over
8.
Neuroradiology ; 66(4): 631-641, 2024 Apr.
Article En | MEDLINE | ID: mdl-38381145

PURPOSE: Our purpose was to assess the efficacy and safety of the pRESET LITE stent retriever (Phenox, Bochum, Germany), designed for medium vessel occlusion (MeVO) in acute ischemic stroke (AIS) patients with a primary MeVO. METHODS: We performed a retrospective analysis of the MAD MT Consortium, an integration of prospectively maintained databases at 37 academic institutions in Europe, North America, and Asia, of AIS patients who underwent mechanical thrombectomy with the pRESET LITE stent retriever for a primary MeVO. We subcategorized occlusions into proximal MeVOs (segments A1, M2, and P1) vs. distal MeVOs/DMVO (segments A2, M3-M4, and P2). We reviewed patient and procedural characteristics, as well as angiographic and clinical outcomes. RESULTS: Between September 2016 and December 2021, 227 patients were included (50% female, median age 78 [65-84] years), of whom 161 (71%) suffered proximal MeVO and 66 (29%) distal MeVO. Using a combined approach in 96% of cases, successful reperfusion of the target vessel (mTICI 2b/2c/3) was attained in 85% of proximal MeVO and 97% of DMVO, with a median of 2 passes (IQR: 1-3) overall. Periprocedural complications rate was 7%. Control CT at day 1 post-MT revealed a hemorrhagic transformation in 63 (39%) patients with proximal MeVO and 24 (36%) patients with DMVO, with ECASS-PH type hemorrhagic transformations occurring in 3 (1%) patients. After 3 months, 58% of all MeVO and 63% of DMVO patients demonstrated a favorable outcome (mRS 0-2). CONCLUSION: Mechanical thrombectomy using the pRESET LITE in a combined approach with an aspiration catheter appears effective for primary medium vessel occlusions across several centers and physicians.


Brain Ischemia , Endovascular Procedures , Ischemic Stroke , Stroke , Aged , Female , Humans , Male , Brain Ischemia/complications , Ischemic Stroke/etiology , Retrospective Studies , Stents , Stroke/etiology , Thrombectomy , Treatment Outcome , Aged, 80 and over
9.
J Neurointerv Surg ; 2024 Jan 18.
Article En | MEDLINE | ID: mdl-38238006

BACKGROUND: The Woven EndoBridge (WEB) device is frequently used for the treatment of intracranial aneurysms. Postoperative management, including the use of aspirin, varies among clinicians and institutions, but its impact on the outcomes of the WEB has not been thoroughly investigated. METHODS: This was a retrospective, multicenter study involving 30 academic institutions in North America, South America, and Europe. Data from 1492 patients treated with the WEB device were included. Patients were categorized into two groups based on their postoperative use of aspirin (aspirin group: n=1124, non-aspirin group: n=368). Data points included patient demographics, aneurysm characteristics, procedural details, complications, and angiographic and functional outcomes. Propensity score matching (PSM) was applied to balance variables between the two groups. RESULTS: Prior to PSM, the aspirin group exhibited significantly higher rates of modified Rankin scale (mRS) mRS 0-1 and mRS 0-2 (89.8% vs 73.4% and 94.1% vs 79.8%, p<0.001), lower rates of mortality (1.6% vs 8.6%, p<0.001), and higher major compaction rates (13.4% vs 7%, p<0.001). Post-PSM, the aspirin group showed significantly higher rates of retreatment (p=0.026) and major compaction (p=0.037) while maintaining its higher rates of good functional outcomes and lower mortality rates. In the multivariable regression, aspirin was associated with higher rates of mRS 0-1 (OR 2.166; 95% CI 1.16 to 4, p=0.016) and mRS 0-2 (OR 2.817; 95% CI 1.36 to 5.88, p=0.005) and lower rates of mortality (OR 0.228; 95% CI 0.06 to 0.83, p=0.025). However, it was associated with higher rates of retreatment (OR 2.471; 95% CI 1.11 to 5.51, p=0.027). CONCLUSIONS: Aspirin use post-WEB treatment may lead to better functional outcomes and lower mortality but with higher retreatment rates. These insights are crucial for postoperative management after WEB procedures, but further studies are necessary for validation.

10.
J Neurointerv Surg ; 16(2): 197-203, 2024 Jan 12.
Article En | MEDLINE | ID: mdl-37192786

BACKGROUND: The morphological assessment of cerebral aneurysms based on cerebral angiography is an essential step when planning strategy and device selection in endovascular treatment, but manual evaluation by human raters only has moderate interrater/intrarater reliability. METHODS: We collected data for 889 cerebral angiograms from consecutive patients with suspected cerebral aneurysms at our institution from January 2017 to October 2021. The automatic morphological analysis model was developed on the derivation cohort dataset consisting of 388 scans with 437 aneurysms, and the performance of the model was tested on the validation cohort dataset consisting of 96 scans with 124 aneurysms. Five clinically important parameters were automatically calculated by the model: aneurysm volume, maximum aneurysm size, neck size, aneurysm height, and aspect ratio. RESULTS: On the validation cohort dataset the average aneurysm size was 7.9±4.6 mm. The proposed model displayed high segmentation accuracy with a mean Dice similarity index of 0.87 (median 0.93). All the morphological parameters were significantly correlated with the reference standard (all P<0.0001; Pearson correlation analysis). The difference in the maximum aneurysm size between the model prediction and reference standard was 0.5±0.7 mm (mean±SD). The difference in neck size between the model prediction and reference standard was 0.8±1.7 mm (mean±SD). CONCLUSION: The automatic aneurysm analysis model based on angiography data exhibited high accuracy for evaluating the morphological characteristics of cerebral aneurysms.


Aneurysm, Ruptured , Deep Learning , Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Reproducibility of Results , Cerebral Angiography/methods , Retrospective Studies
11.
J Cerebrovasc Endovasc Neurosurg ; 26(1): 65-70, 2024 Mar.
Article En | MEDLINE | ID: mdl-37723100

We present a case of intracranial aneurysm located in the P1 segment of left posterior cerebral artery in the context of tetralogy of Fallot. Complex variations included right aortic arch with abnormal branching. Also, the bilateral vertebral arteries were absent, with a type I persistent proatlantal intersegmental artery of the left side. The aneurysm was treated with endovascular intervention with a Tubridge flow diverter and was noted to be completely cured on 6-month follow-up. We discuss the many considerations in this patient including developmental and modern-era treatment.

12.
Eur Stroke J ; 9(1): 114-123, 2024 Mar.
Article En | MEDLINE | ID: mdl-37885243

INTRODUCTION: First pass effect (FPE), achievement of complete recanalization (mTICI 2c/3) with a single pass, is a significant predictor of favorable outcomes for endovascular treatment (EVT) in large vessel occlusion stroke (LVO). However, data concerning the impact on functional outcomes and predictors of FPE in medium vessel occlusions (MeVO) are scarce. PATIENTS AND METHODS: We conducted an international retrospective study on MeVO cases. Multivariable logistic modeling was used to establish independent predictors of FPE. Clinical and safety outcomes were compared between the two study groups (FPE vs non-FPE) using logistic regression models. Good outcome was defined as modified Rankin Scale 0-2 at 3 months. RESULTS: Eight hundred thirty-six patients with a final mTICI ⩾ 2b were included in this analysis. FPE was observed in 302 patients (36.1%). In multivariable analysis, hypertension (aOR 1.55, 95% CI 1.10-2.20) and lower baseline NIHSS score (aOR 0.95, 95% CI 0.93-0.97) were independently associated with an FPE. Good outcomes were more common in the FPE versus non-FPE group (72.8% vs 52.8%), and FPE was independently associated with favorable outcome (aOR 2.20, 95% CI 1.59-3.05). 90-day mortality and intracranial hemorrhage (ICH) were significantly lower in the FPE group, 0.43 (95% CI, 0.25-0.72) and 0.55 (95% CI, 0.39-0.77), respectively. CONCLUSION: Over 2/3 of patients with MeVOs and FPE in our cohort had a favorable outcome at 90 days. FPE is independently associated with favorable outcomes, it may reduce the risk of any intracranial hemorrhage, and 3-month mortality.


Brain Ischemia , Stroke , Humans , Brain Ischemia/therapy , Retrospective Studies , Thrombectomy , Treatment Outcome , Intracranial Hemorrhages/etiology
13.
J Neurointerv Surg ; 16(4): 405-411, 2024 Mar 14.
Article En | MEDLINE | ID: mdl-37793795

BACKGROUND: Robotic-assisted neurointervention was recently introduced, with implications that it could be used to treat neurovascular diseases. OBJECTIVE: To evaluate the effectiveness and safety of the robotic-assisted platform CorPath GRX for treating cerebral aneurysms. METHODS: This prospective, international, multicenter study enrolled patients with brain aneurysms that required endovascular coiling and/or stent-assisted coiling. The primary effectiveness endpoint was defined as successful completion of the robotic-assisted endovascular procedure without any unplanned conversion to manual treatment with guidewire or microcatheter navigation, embolization coil(s) or intracranial stent(s) deployment, or an inability to navigate vessel anatomy. The primary safety endpoint included intraprocedural and periprocedural events. RESULTS: The study enrolled 117 patients (74.4% female) with mean age of 56.6 years from 10 international sites,. Headache was the most common presenting symptom in 40/117 (34.2%) subjects. Internal carotid artery was the most common location (34/122, 27.9%), and the mean aneurysm height and neck width were 5.7±2.6 mm and 3.5±1.4 mm, respectively. The overall procedure time was 117.3±47.3 min with 59.4±32.6 min robotic procedure time. Primary effectiveness was achieved in 110/117 (94%) subjects with seven subjects requiring conversion to manual for procedure completion. Only four primary safety events were recorded with two intraprocedural aneurysm ruptures and two strokes. A Raymond-Roy Classification Scale score of 1 was achieved in 71/110 (64.5%) subjects, and all subjects were discharged with a modified Rankin Scale score of ≤2. CONCLUSIONS: This first-of-its-kind robotic-assisted neurovascular trial demonstrates the effectiveness and safety of the CorPath GRX System for endovascular embolization of cerebral aneurysm procedures. TRIAL REGISTRATION NUMBER: NCT04236856.


Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Robotic Surgical Procedures , Female , Humans , Male , Middle Aged , Cerebral Angiography , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/methods , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Prospective Studies , Retrospective Studies , Robotic Surgical Procedures/adverse effects , Robotic Surgical Procedures/methods , Stents , Treatment Outcome
14.
Neuroradiol J ; : 19714009231212368, 2023 Nov 03.
Article En | MEDLINE | ID: mdl-37920948

BACKGROUND: Percutaneous cement discoplasty (PCD) is a minimally invasive procedure. We aim to explore the efficacy and indication(s) of PCD in patients with degenerative disc disease (DDD). METHODS: The search was conducted across Ovid MEDLINE, Ovid Embase, and PubMed. Data on study design, patient demographics, pre- and post-procedure Visual Analog Scale (VAS) and Oswestry Disability Index (ODI) scores, and complications were extracted. Inclusion criteria focused on adult patients with degenerative spinal diseases treated with cement discoplasty. The overall effect size was evaluated using a forest plot, and heterogeneity was assessed using the I2 statistic and chi-squared test. RESULTS: The search strategy yielded six studies, which included 336 patients (73.8% female, 26.2% male) with a mean average age of 74.6 years. VAS scores were reported in all studies, showing a significant difference between pre- and post-PCD pain scores (Weighted Mean Difference [WMD]: -3.45; 95% CI: -3.83, -3.08; I2 = 15%; P < .001). ODI scores were reported in 83% of studies, with a significant difference between pre- and post-PCD scores (WMD: -22.22; 95% CI: -25.54, -18.89; I2 = 61%; p < .001). Complications reported included infections, thrombophlebitis, vertebral fractures, disc extrusion, and the need for further operations. CONCLUSIONS: The analysis showed clinically significant improvements in pain and functional disability based on VAS and ODI scores. However, due to methodological limitations and a high risk of bias, the validity and generalizability of the findings are uncertain. Despite these issues, the results provide preliminary insights into PCD's potential efficacy and can guide future research to address current limitations.

15.
Comput Methods Programs Biomed ; 241: 107762, 2023 Nov.
Article En | MEDLINE | ID: mdl-37598472

BACKGROUND AND OBJECTIVE: Vessel geometry and hemodynamics are intrinsically linked, whereby geometry determines hemodynamics, and hemodynamics influence vascular remodeling. Both have been used for testing clinical outcomes, but geometry/morphology generally has less uncertainty than hemodynamics derived from medical image-based computational fluid dynamics (CFD). To provide clinical utility, CFD-based hemodynamic parameters must be robust to modeling errors and/or uncertainties, but must also provide useful information not more-easily extracted from shape alone. The objective of this study was to methodically assess the response of hemodynamic parameters to gradual changes in shape created using an unsupervised 3D shape interpolation method. METHODS: We trained the neural network NeuroMorph on 3 patient-derived intracranial aneurysm surfaces (labelled A, B, C), and then generated 3 distinct morph sequences (A→B, B→C, C→A) each containing 10 interpolated surfaces. From high-fidelity CFD simulation of these, we calculated a variety of common reduced hemodynamic parameters, including many previously associated with aneurysm rupture, and analyzed their responses to changes in shape, and their correlations. RESULTS: The interpolated surfaces demonstrate complex, gradual changes in branch angles, vessel diameters, and aneurysm morphology. CFD simulation showed gradual changes in aneurysm jetting characteristics and wall-shear stress (WSS) patterns, but demonstrated a range of responses from the reduced hemodynamic parameters. Spatially and temporally averaged parameters including time-averaged WSS, time-averaged velocity, and low-shear area (LSA) showed low variation across all morph sequences, while parameters of flow complexity such as oscillatory shear, spectral broadening, and spectral bandedness indices showed high variation between slightly-altered neighboring surfaces. Correlation analysis revealed a great deal of mutual information with easier-to-measure shape-based parameters. CONCLUSIONS: In the absence of large clinical datasets, unsupervised shape interpolation provides an ideal laboratory for exploring the delicate balance between robustness and sensitivity of nominal hemodynamic predictors of aneurysm rupture. Parameters like time-averaged WSS and LSA that are highly "robust" may, as a result, be effectively redundant to morphological predictors, whereas more sensitive parameters may be too uncertain for practical clinical use. Understanding these sensitivities may help identify parameters that are capable of providing added value to rupture risk assessment.


Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Computer Simulation , Hemodynamics , Hydrodynamics , Neural Networks, Computer
16.
Neurointervention ; 18(2): 80-89, 2023 Jun.
Article En | MEDLINE | ID: mdl-37337397

The management of unruptured brain arteriovenous malformations (ubAVMs) is a complex challenge to neurovascular practitioners. This meta-analysis aimed to identify the optimal management of ubAVMs comparing conservative management, embolization, radiosurgery, microsurgical resection, and multimodality. The search strategy was developed a priori according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We searched the Ovid Medline, Embase, Web of Science, and Cochrane Library databases to identify relevant papers. Using R version 4.1.1., a frequentist network meta-analysis was conducted to compare different management modalities for the ubAVMs. Overall, the conservative group had the lowest risk of rupture (P-score=0.77), and the lowest rate of complications was found in the conservative group (P-score=1). Among different interventions, the multimodality group had the highest rupture risk (P-score=0.34), the lowest overall complications (P-score=0.75), the best functional improvement (P-score=0.65), and the lowest overall mortality (P-score=0.8). However, multimodality treatment showed a significantly higher risk of rupture (odds ratio [OR]=2.13; 95% confidence interval [95% CI]=1.18-3.86) and overall complication rate (OR=5.56; 95% CI=3.37-9.15) compared to conservative management; nevertheless, there were no significant differences in overall mortality or functional independence when considered independently. Conservative management is associated with the lowest rupture risk and complication rate overall. A multimodal approach is the best option when considering mortality rates and functional improvement in the context of existing morbidity/symptoms. Microsurgery, embolization, and radiosurgery alone are similar to the natural history in terms of functional improvement and mortality, but have higher complication rates.

17.
Transl Stroke Res ; 2023 May 11.
Article En | MEDLINE | ID: mdl-37165289

The Woven EndoBridge (WEB) device has been widely used to treat intracranial wide neck bifurcation aneurysms. Initial studies have demonstrated that approximately 90% of patients have same or improved long-term aneurysm occlusion after the initial 6-month follow up. The aim of this study is to assess the long-term follow-up in aneurysms that have achieved complete occlusion at 6 months. We also compared the predictive value of different imaging modalities used. This is an analysis of a prospectively maintained database across 13 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB device who achieved complete occlusion at first follow-up and had available long-term follow-up. A total of 95 patients with a mean age of 61.6 ± 11.9 years were studied. The mean neck diameter and height were 3.9 ± 1.3 mm and 6.0 ± 1.8 mm, respectively. The mean time to first and last follow-up was 5.4 ± 1.8 and 14.1 ± 12.9 months, respectively. Out of all the aneurysms that were completely occluded at 6 months, 84 (90.3%) showed complete occlusion at the final follow-up, and 11(11.5%) patients did not achieve complete occlusion. The positive predictive value (PPV) of complete occlusion at first follow was 88.4%. Importantly, this did not differ between digital subtraction angiography (DSA), magnetic resonance angiography (MRA), or computed tomography angiography (CTA). This study underlines the importance of repeat imaging in patients treated with the WEB device even if complete occlusion is achieved short term. Follow-up can be performed using DSA, MRA or CTA with no difference in positive predictive value.

18.
Interv Neuroradiol ; : 15910199231175377, 2023 May 16.
Article En | MEDLINE | ID: mdl-37192738

BACKGROUND: Intra-procedural characterization of stroke thromboemboli might guide mechanical thrombectomy (MT) device choice to improve recanalization rates. Electrochemical impedance spectroscopy (EIS) has been used to characterize various biological tissues in real time but has not been used in thrombus. OBJECTIVE: To perform a feasibility study of EIS analysis of thrombi retrieved by MT to evaluate: (1) the ability of EIS and machine learning to predict red blood cell (RBC) percentage content of thrombi and (2) to classify the thrombi as "RBC-rich" or "RBC-poor" based on a range of cutoff values of RBC. METHODS: ClotbasePilot was a multicentric, international, prospective feasibility study. Retrieved thrombi underwent histological analysis to identify proportions of RBC and other components. EIS results were analyzed with machine learning. Linear regression was used to evaluate the correlation between the histology and EIS. Sensitivity and specificity of the model to classify the thrombus as RBC-rich or RBC-poor were also evaluated. RESULTS: Among 514 MT,179 thrombi were included for EIS and histological analysis. The mean composition in RBC of the thrombi was 36% ± 24. Good correlation between the impedance-based prediction and histology was achieved (slope of 0.9, R2 = 0.53, Pearson coefficient = 0.72). Depending on the chosen cutoff, ranging from 20 to 60% of RBC, the calculated sensitivity for classification of thrombi ranged from 77 to 85% and the specificity from 72 to 88%. CONCLUSION: Combination of EIS and machine learning can reliably predict the RBC composition of retrieved ex vivo AIS thrombi and then classify them into groups according to their RBC composition with good sensitivity and specificity.

19.
J Biomech Eng ; 145(7)2023 07 01.
Article En | MEDLINE | ID: mdl-36752715

Computational fluid dynamics (CFD) of cerebral venous flows has become popular owing to the possibility of using local hemodynamics and hemoacoustics to help diagnose and plan treatments for venous diseases of the brain. Lumen geometries in low-pressure cerebral veins are different from those in cerebral arteries, often exhibiting fenestrations and flattened or triangular cross section, in addition to constrictions and expansions. These can challenge conventional size-based volume meshing strategies, and the ability to resolve nonlaminar flows. Here we present a novel strategy leveraging estimation of length scales that could be present if flow were to become transitional or turbulent. Starting from the lumen geometry and flow rate boundary conditions, centerlines are used to determine local hydraulic diameters and cross-sectional mean velocities, from which flow length scales are approximated using conventional definitions of local Kolmogorov and Taylor microscales. By inspection of these scales, a user specifies minimum and maximum mesh edge lengths, which are then distributed along the model in proportion to the approximated local Taylor length scales. We demonstrate in three representative cases that this strategy avoids some of the pitfalls of conventional size-based strategies. An exemplary CFD mesh-refinement study shows convergence of high-frequency flow instabilities even starting from relatively coarse edge lengths near the lower bounds of the approximated Taylor length scales. Rational consideration of the length scales in a possibly nonlaminar flow may thus provide a useful and replicable baseline for denovo meshing of complicated or unfamiliar venous lumen geometries.


Cerebral Veins , Hydrodynamics , Cross-Sectional Studies , Hemodynamics , Prostheses and Implants , Computer Simulation , Blood Flow Velocity , Models, Cardiovascular
20.
Cardiovasc Eng Technol ; 14(2): 252-263, 2023 04.
Article En | MEDLINE | ID: mdl-36517696

INTRODUCTION: Overestimation of intracranial aneurysm neck width by 3D angiography is a recognized clinical problem, and has long been a concern for image-based computational fluid dynamics (CFD). Recently, it was demonstrated that neck overestimation in 3D rotational angiography (3DRA) could be corrected via segmentation with upsampled resolution and gradient enhancement (SURGE). Our aim was to leverage this approach to determine whether and how neck overestimation actually impacts CFD-derived hemodynamics. MATERIALS AND METHODS: A subset of 17 cases having the largest neck errors from a consecutive clinical sample of 60 was segmented from 3DRA using both standard watershed and SURGE methods. High-fidelity, pulsatile CFD was performed, and a variety of scalar hemodynamic parameters that have been associated with aneurysm growth and/or rupture status were derived. RESULTS: With a few exceptions, flow and wall shear stress (WSS) patterns were qualitatively similar between neck-overestimated and corrected models. Sac-averaged WSS values were significantly lower after neck correction (p = 0.0005) but were highly correlated with their neck-overestimated counterparts (R2 = 0.98). Jet impingement was significantly more concentrated in the neck-corrected vs. -uncorrected models (p = 0.0011), and only moderately correlated (R2 = 0.61). Parameters quantifying velocity or WSS fluctuations were not significantly different after neck correction, but this reflected their poorer correlations (R2 < 0.4). Nevertheless, for all hemodynamic parameters, median absolute differences were < 26%, and no parameter had more than 5/17 cases with absolute differences > 50%. CONCLUSION: Differences in hemodynamics due to neck width overestimation were found to be at most equal to, and often less than, those reported for other sources of error/uncertainty in intracranial aneurysm CFD, such as solver settings or assumed inflow rates.


Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Imaging, Three-Dimensional , Hemodynamics , Stress, Mechanical , Hydrodynamics
...