Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Spine J ; 27(1): 154-162, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28364336

RESUMEN

PURPOSE: The instantaneous center of rotation (ICR) can be used to investigate movement coordination and control in patients with low back pain (LBP). Tracking of the ICR in LBP patients has not been systematically investigated. This study aimed to (1) determine the within-session measurement error of ICR parameters, and (2) characterize the change in ICR among three groups of participants (no history of LBP = HC; history of LBP = HLBP; and current LBP = LBP). METHODS: Ninety-three participants (HC = 31; HLBP = 33; and LBP = 29) were recruited. Participants performed two sets of three repetitions of an active forward bend, while their lumbar and pelvic movements were recorded with an electromagnetic tracking system. Total ICR displacement and the radius of the bounding sphere containing the ICR were derived during the forward bending and the return to upright phases. Intra-class correlation coefficients (ICC3,3) and minimal detectable difference (MDD) were used to determine measurement error and interpret findings of the group analysis. One-way ANOVAs and post hoc Bonferroni comparisons were used to determine differences among groups. RESULTS: ICC3,3 demonstrated excellent within-session test-retest reliability of the ICR parameters (ICC3,3 = 0.86-0.97). The MDD values were 0.20-3.40 mm. Comparisons between the HC and LBP groups and between the HLBP and LBP groups showed significant differences (p < 0.05) for all ICR parameters, with medium effect sizes (0.51-0.66), except for total displacement during forward bending between the HC and LBP groups. CONCLUSION: Less ICR displacement and variability in patients with LBP may indicate coping strategies to stiffen the lumbar spine. This could result from patients with LBP adopting a strategy of increased muscle activation to provide spinal stability during functional tasks.


Asunto(s)
Dolor de la Región Lumbar/fisiopatología , Vértebras Lumbares/fisiopatología , Rango del Movimiento Articular/fisiología , Adolescente , Adulto , Anciano , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Postura/fisiología , Reproducibilidad de los Resultados , Adulto Joven
2.
Motor Control ; 21(2): 133-157, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26623551

RESUMEN

Trunk muscle timing impairment has been associated with nonspecific low back pain (NSLBP), but this finding has not been consistent. This study investigated trunk muscle timing in a subgroup of patients with NSLBP attributed to movement coordination impairment (MCI) and matched asymptomatic controls in response to a rapid arm-raising task. Twenty-one NSLBP subjects and 21 matched controls had arm motion and surface EMG data collected from seven bilateral trunk muscles. Muscle onset and offset relative to deltoid muscle activation and arm motion, duration of muscle burst and abdominal-extensor co-contraction time were derived. Trunk muscle onset and offset latencies, and burst and co-contraction durations were not different (p > .05) between groups. Patterns of trunk muscle activation and deactivation relative to arm motion were not different. Task performance was similar between groups. Trunk muscle timing does not appear to be an underlying impairment in the subgroup of NSLBP with MCI.


Asunto(s)
Ataxia/complicaciones , Dolor de la Región Lumbar/patología , Postura/fisiología , Torso/patología , Adulto , Femenino , Humanos , Masculino , Músculo Esquelético/fisiología
3.
J Magn Reson ; 258: 6-11, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26150377

RESUMEN

The analysis of double and zero quantum filtered (2)H NMR spectra obtained from D2O perfused in the nucleus pulposus of human intervertebral disc tissue samples is reported. Fitting the spectra with a three-site model allows for residual quadrupolar couplings and T2 relaxation times to be measured. The analysis reveals changes in both the couplings and relaxation times as the tissue begins to show signs of degradation. The full analysis demonstrates that information about tissue hydration, water collagen interactions, and sample heterogeneity can be obtained and used to better understand the biochemical differences between healthy and degraded tissue.


Asunto(s)
Algoritmos , Agua Corporal/química , Óxido de Deuterio/análisis , Desplazamiento del Disco Intervertebral/metabolismo , Disco Intervertebral/química , Procesamiento de Señales Asistido por Computador , Adolescente , Adulto , Anciano , Humanos , Hidrógeno/análisis , Desplazamiento del Disco Intervertebral/diagnóstico , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
4.
J Biomech Eng ; 136(5): 051001, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24599572

RESUMEN

Nucleus pulposus replacement and augmentation has been proposed to restore disk mechanics in early stages of degeneration with the option of providing a minimally invasive procedure for pain relief to patients with an earlier stage of degeneration. The goal of this paper is to examine compressive stability of the intervertebral disk after either partial nucleus replacement or nuclear augmentation in the absence of denucleation. Thirteen human cadaver lumbar anterior column units were used to study the effects of denucleation and augmentation on the compressive mechanical behavior of the human intervertebral disk. Testing was performed in axial compression after incremental steps of partial denucleation and subsequent implantation of a synthetic hydrogel nucleus replacement. In a separate set of experiments, the disks were not denucleated but augmented with the same synthetic hydrogel nucleus replacement. Neutral zone, range of motion, and stiffness were measured. The results showed that compressive stabilization of the disk can be re-established with nucleus replacement even for partial denucleation. Augmentation of the disk resulted in an increase in disk height and intradiskal pressure that were linearly related to the volume of polymer implanted. Intervertebral disk instability, evidenced by increased neutral zone and ranges of motion, associated with degeneration can be restored by volume filling of the nucleus pulposus using the hydrogel device presented here.


Asunto(s)
Discectomía/métodos , Disco Intervertebral/cirugía , Fenómenos Mecánicos , Prótesis e Implantes , Reeemplazo Total de Disco/métodos , Fenómenos Biomecánicos , Fuerza Compresiva , Humanos
5.
J Biomech Eng ; 135(9): 91009, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23775506

RESUMEN

Thirty-four percent of U.S. Navy high speed craft (HSC) personnel suffer from lower back injury and low back pain, compared with 15 to 20% of the general population. Many of these injuries are specifically related to the intervertebral disc, including discogenic pain and accelerated disc degeneration. Numerous studies have characterized the mechanical behavior of the disc under normal physiological loads, while several have also analyzed dynamic loading conditions. However, the effect of impact loads on the lumbar disc--and their contribution to the high incidence of low back pain among HSC personnel--is still not well understood. An ex-vivo study on human lumbar anterior column units was performed in order to investigate disc biomechanical response to impact loading conditions. Samples were subjected to a sequence of impact events of varying duration (Δt = 80, 160, 320, 400, 600, 800, and 1000 ms) and the level of displacement (0.2, 0.5, and 0.8 mm), stiffness k, and energy dissipation ΔE were measured. Impacts of Δt = 80 ms saw an 18-21% rise in k and a 3-7% drop in ΔE compared to the 1000 ms baseline, signaling an abrupt change in disc mechanics. The altered disc mechanical response during impact likely causes more load to be transferred directly to the endplates, vertebral bodies, and surrounding soft tissues and can help begin to explain the high incidence of low back pain among HSC operators and other individuals who typically experience similar loading environments. The determination of a "safety range" for impacts could result in a refinement of design criteria for shock mitigating systems on high-speed craft, thus addressing the low back injury problem among HSC personnel.


Asunto(s)
Disco Intervertebral/fisiología , Vértebras Lumbares/fisiología , Fenómenos Mecánicos , Soporte de Peso , Fenómenos Biomecánicos , Humanos
6.
Spine (Phila Pa 1976) ; 35(11): 1128-35, 2010 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-20473120

RESUMEN

STUDY DESIGN: Axial loading, rotation, and bending were applied to human cadaveric lumbar segments to investigate the changes in disc mechanics with denucleation and incremental delivery of a novel hydrogel nucleus replacement. OBJECTIVE: The purpose of this study was to investigate the effect of nucleus implant injection pressure/volume relationships on the quasi-static mechanical behavior of the human cadaveric lumbar intervertebral disc to determine if intact biomechanics could be reproduced with nucleus-implanted discs. SUMMARY OF BACKGROUND DATA: Previous studies have shown that volumetric filling of the nucleus cavity with a compliant nucleus replacement device will affect compressive stiffness of the implanted intervertebral disc, but data regarding restoration of mechanics through cavity pressurization are lacking. METHODS: A total of 12 intact lumbar anterior column units were loaded in series in axial loading, axial rotation, lateral bending, and flexion/extension (FE). Each segment was fully denucleated and implanted with a hydrogel nucleus replacement using pressurization between 12 psi and 40 psi. Range of motion (ROM), neutral zone (NZ), energy dissipation (HYS), disc height (DH), and stiffness were compared among the intact, denucleated, and implanted conditions. RESULTS: Denucleation significantly destabilized the segments compared to intact controls as shown by increased ROM, NZ, and HYS, and decreased DH and stiffness through the NZ. As the nucleus cavity was repressurized with increasing volumes of hydrogel implant, the segments were stabilized and DH was restored to the intact level. No significant differences from intact were observed in any loading direction for ROM, NZ, or DH after the segments were implanted with the nucleus replacement device using inflation pressures between 20 psi and 40 psi. CONCLUSION: Compliant nucleus replacement using inflation pressures of 20 to 40 psi resulted in restoration of intact mechanics. Mechanical function was dependent on the volume of implant injected into the nucleus cavity.


Asunto(s)
Disco Intervertebral/fisiopatología , Vértebras Lumbares/fisiopatología , Rango del Movimiento Articular/fisiología , Artroplastia de Reemplazo , Fenómenos Biomecánicos/fisiología , Fuerza Compresiva/fisiología , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Disco Intervertebral/cirugía , Vértebras Lumbares/cirugía , Movimiento/fisiología , Estrés Mecánico , Soporte de Peso/fisiología
7.
J Mot Behav ; 42(2): 135-44, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20207604

RESUMEN

The authors investigated differences in trunk muscle activation timing between patients with chronic nonspecific low back pain (NSLBP) and asymptomatic controls during a self-initiated postural challenge. The authors compared 30 participants with NSLBP to 30 controls. Surface electromyographic data were collected from bilateral trunk muscles. Dependent variables were trunk muscle onset and offset relative to extremity muscle activation and duration of the trunk muscle burst and abdominal-extensor cocontraction. Patients with NSLBP demonstrated significantly delayed trunk muscle onset latency (p < .01), and shorter burst (p = .02) and cocontraction durations (p < .01). Results suggest that patients with NSLBP may be inefficient in regulating trunk posture during voluntary extremity movements. These alterations could also represent a compensatory control pattern imposed by the CNS to avoid pain.


Asunto(s)
Intención , Dolor de la Región Lumbar/fisiopatología , Músculo Esquelético/fisiología , Equilibrio Postural , Desempeño Psicomotor/fisiología , Adaptación Fisiológica , Adulto , Estudios de Casos y Controles , Electromiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Contracción Muscular/fisiología , Valores de Referencia , Factores de Tiempo
8.
J Magn Reson ; 195(1): 112-5, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18774321

RESUMEN

A method for acquiring triple quantum filtered (TQF) (23)Na NMR images is proposed that takes advantage of the differences in transverse relaxation rates of sodium to achieve positive intensity, PI, NMR signal. This PITQF imaging sequence has been used to obtain spatially resolved one-dimensional images as a function of the TQF creation time, tau, for two human spinal disc samples. From the images the different parts of the tissue, nucleus pulposus and annulus fibrosus, can be clearly distinguished based on their signal intensity and creation time profiles. These results establish the feasibility of (23)Na TQF imaging and demonstrate that this method should be applicable for studying human disc tissues as well as spinal disc degeneration.


Asunto(s)
Desplazamiento del Disco Intervertebral/metabolismo , Disco Intervertebral/química , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Isótopos de Sodio/química , Anciano , Femenino , Humanos , Masculino , Coloración y Etiquetado/métodos
9.
Magn Reson Med ; 60(2): 246-52, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18666105

RESUMEN

Degenerative disc disease is an irreversible process that leads to a loss of mechanical integrity and back pain in millions of people. In this report, (23)Na double-quantum-filtered (DQF) NMR spectroscopy is used to study disc tissues in two stages of degeneration. Initial results indicate that the (23)Na DQF signal may be useful for determining the degree of degeneration. The spectral analysis reveals the presence of sodium environments with different residual quadrupolar couplings and T(2) relaxation times that we attribute to different regions, or compartments, corresponding to different biochemical regions in the tissue. In general it is found that there are compartments with no residual quadrupolar couplings, compartments with moderate couplings (200 to 1000 Hz), and compartments with couplings ranging from 1500 to 3000 Hz. The results indicate that (23)Na DQF NMR spectroscopy provides a probe of the degenerative state of the intervertebral disc tissues, and might hold potential as a novel diagnostic method for detection of disc degeneration.


Asunto(s)
Agua Corporal/química , Diagnóstico por Computador/métodos , Desplazamiento del Disco Intervertebral/diagnóstico , Desplazamiento del Disco Intervertebral/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Agua/análisis , Adolescente , Anciano , Humanos , Procesamiento de Señales Asistido por Computador , Isótopos de Sodio/análisis , Isótopos de Sodio/química
10.
J Biomech ; 41(10): 2104-11, 2008 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-18571654

RESUMEN

To study the effect of denucleation on the mechanical behavior of the human lumbar intervertebral disc through a 2mm incision, two groups of six human cadaver lumbar spinal units were tested in axial compression, axial rotation, lateral bending and flexion/extension after incremental steps of "partial" denucleation. Neutral zone, range of motion, stiffness, intradiscal pressure and energy dissipation were measured; the results showed that the contribution of the nucleus pulposus to the mechanical behavior of the intervertebral disc was more dominant through the neutral zone than at the farther limits of applied loads and moments.


Asunto(s)
Fenómenos Biomecánicos/métodos , Disco Intervertebral/anatomía & histología , Vértebras Lumbares/anatomía & histología , Cadáver , Diseño de Equipo , Humanos , Región Lumbosacra/anatomía & histología , Rango del Movimiento Articular , Estrés Mecánico , Resistencia a la Tracción , Articulación Cigapofisaria/anatomía & histología
11.
Magn Reson Med ; 57(6): 990-9, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17534920

RESUMEN

Deuterium (2H) double-quantum filtered (DQF) NMR spectroscopy of nucleus pulposus (NP) tissues from human intervertebral discs is reported. The DQF spectral intensities, DQ build-up rates, and DQF-detected rotating-frame spin-lattice relaxation times are sensitive to the degree of hydration of the NP tissue, and display a monotonous correlation with age between 15 and 80 years. The implications of this work are that the changes in water dynamics as detected via DQF NMR spectroscopy may be used as a probe of tissue degeneration in NP, particularly in the early stages of degeneration to which most standard NMR methods are not sensitive.


Asunto(s)
Disco Intervertebral/patología , Espectroscopía de Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Envejecimiento/fisiología , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...