Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Radiat Environ Biophys ; 52(4): 481-91, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24077963

RESUMEN

Boron neutron capture therapy (BNCT) was proposed for untreatable colorectal liver metastases. Employing an experimental model of liver metastases in rats, we recently demonstrated that BNCT mediated by boronophenylalanine (BPA-BNCT) at 13 Gy prescribed to tumor is therapeutically useful at 3-week follow-up. The aim of the present study was to evaluate dose­response at 5-week follow-up, based on retrospective dose assessment in individual rats. BDIX rats were inoculated with syngeneic colon cancer cells DHD/K12/TRb. Tumor-bearing animals were divided into three groups: BPA-BNCT (n = 19), Beam only (n = 8) and Sham (n = 7) (matched manipulation, no treatment). For each rat, neutron flux was measured in situ and boron content was measured in a pre-irradiation blood sample for retrospective individual dose assessment. For statistical analysis (ANOVA), individual data for the BPA-BNCT group were pooled according to absorbed tumor dose, BPA-BNCT I: 4.5­8.9 Gy and BPA-BNCT II: 9.2­16 Gy. At 5 weeks post-irradiation, the tumor surface area post-treatment/pre-treatment ratio was 12.2 ± 6.6 for Sham, 7.8 ± 4.1 for Beam only, 4.4 ± 5.6 for BPA-BNCT I and 0.45 ± 0.20 for BPA-BNCT II; tumor nodule weight was 750 ± 480 mg for Sham, 960 ± 620 mg for Beam only, 380 ± 720 mg for BPA-BNCT I and 7.3 ± 5.9 mg for BPA-BNCT II. The BPA-BNCT II group exhibited statistically significant tumor control with no contributory liver toxicity. Potential threshold doses for tumor response and significant tumor control were established at 6.1 and 9.2 Gy, respectively.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Neoplasias Colorrectales/patología , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundario , Animales , Relación Dosis-Respuesta en la Radiación , Femenino , Estudios de Seguimiento , Masculino , Dosificación Radioterapéutica , Ratas , Estudios Retrospectivos
2.
Radiat Environ Biophys ; 51(3): 331-9, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22544068

RESUMEN

Boron neutron capture therapy (BNCT) was proposed for untreatable colorectal liver metastases. The present study evaluates tumor control and potential radiotoxicity of BNCT in an experimental model of liver metastasis. BDIX rats were inoculated with syngeneic colon cancer cells DHD/K12/TRb. Tumor-bearing animals were divided into three groups: BPA-BNCT, boronophenylalanine (BPA) + neutron irradiation; Beam only, neutron irradiation; Sham, matched manipulation. The total absorbed dose administered with BPA-BNCT was 13 ± 3 Gy in tumor and 9 ± 2 Gy in healthy liver. Three weeks post-treatment, the tumor surface area post-treatment/pre-treatment ratio was 0.46 ± 0.20 for BPA-BNCT, 2.7 ± 1.8 for Beam only and 4.5 ± 3.1 for Sham. The pre-treatment tumor nodule mass of 48 ± 19 mg fell significantly to 19 ± 16 mg for BPA-BNCT, but rose significantly to 140 ± 106 mg for Beam only and to 346 ± 302 mg for Sham. For both end points, the differences between the BPA-BNCT group and each of the other groups were statistically significant (ANOVA). No clinical, macroscopic or histological normal liver radiotoxicity was observed. It is concluded that BPA-BNCT induced a significant remission of experimental colorectal tumor nodules in liver with no contributory liver toxicity.


Asunto(s)
Terapia por Captura de Neutrón de Boro/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundario , Animales , Terapia por Captura de Neutrón de Boro/efectos adversos , Neoplasias Colorrectales/patología , Modelos Animales de Enfermedad , Femenino , Hígado/patología , Hígado/efectos de la radiación , Masculino , Dosificación Radioterapéutica , Ratas , Resultado del Tratamiento
3.
Radiat Environ Biophys ; 50(1): 199-207, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21132507

RESUMEN

We previously demonstrated the therapeutic efficacy of different boron neutron capture therapy (BNCT) protocols in an experimental model of oral cancer. BNCT is based on the selective accumulation of (10)B carriers in a tumor followed by neutron irradiation. Within the context of exploring the potential therapeutic efficacy of BNCT for the treatment of liver metastases, the aim of the present study was to perform boron biodistribution studies in an experimental model of liver metastases in rats. Different boron compounds and administration conditions were assayed to determine which administration protocols would potentially be therapeutically useful in in vivo BNCT studies at the RA-3 nuclear reactor. A total of 70 BDIX rats were inoculated in the liver with syngeneic colon cancer cells DHD/K12/TRb to induce the development of subcapsular tumor nodules. Fourteen days post-inoculation, the animals were used for biodistribution studies. We evaluated a total of 11 administration protocols for the boron compounds boronophenylalanine (BPA) and GB-10 (Na(2)(10)B(10)H(10)), alone or combined at different dose levels and employing different administration routes. Tumor, normal tissue, and blood samples were processed for boron measurement by atomic emission spectroscopy. Six protocols proved potentially useful for BNCT studies in terms of absolute boron concentration in tumor and preferential uptake of boron by tumor tissue. Boron concentration values in tumor and normal tissues in the liver metastases model show it would be feasible to reach therapeutic BNCT doses in tumor without exceeding radiotolerance in normal tissue at the thermal neutron facility at RA-3.


Asunto(s)
Compuestos de Boro/farmacocinética , Compuestos de Boro/uso terapéutico , Terapia por Captura de Neutrón de Boro , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/radioterapia , Animales , Modelos Animales de Enfermedad , Femenino , Neoplasias Hepáticas/secundario , Masculino , Ratas
4.
Int J Radiat Biol ; 83(10): 699-706, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17729164

RESUMEN

PURPOSE: The effect of Boron Neutron Capture Therapy (BNCT) on normal liver regeneration was examined in the Wistar rat. The model used is clinically relevant to a novel technique proposed for the treatment of multifocal non-resectable liver metastases in man. The success of the technique also requires that BNCT should not significantly impair regeneration of normal hepatocytes. MATERIALS AND METHODS: The effect of therapeutic doses of boronophenylalanine (BPA), GB-10 (Na(2)(10)B(10)H(10)) and (GB-10 + BPA) and of BNCT mediated by these boron delivery agents on normal liver regeneration and liver function in the Wistar rat was examined using partial hepatectomy as the regenerative stimulus. The end-points evaluated were body weight, liver weight/body weight ratio, DNA synthesis in terms of 5-bromo-2'-deoxyuridine incorporation, hemogram, kidney function in terms of blood urea nitrogen and creatinine levels, liver function in terms of serum albumin, total and direct bilirubin and liver enzymes (alanine transaminase and aspartate transaminase) and liver histology/architecture. RESULTS: BNCT mediated by BPA, GB-10 or (GB-10 + BPA) did not cause alterations in the outcome of normal liver regeneration, regenerated liver function/proliferation or histology/architecture. CONCLUSION: The BNCT protocols, at the physical doses selected, did not impair the capacity of normal liver hepatocytes to regenerate.


Asunto(s)
Peso Corporal/efectos de la radiación , Compuestos de Boro/uso terapéutico , Terapia por Captura de Neutrón de Boro/métodos , Neoplasias Hepáticas/radioterapia , Regeneración Hepática/efectos de la radiación , Tamaño de los Órganos/efectos de la radiación , Fenilalanina/análogos & derivados , Animales , ADN/biosíntesis , Modelos Animales de Enfermedad , Relación Dosis-Respuesta en la Radiación , Hepatocitos/metabolismo , Hepatocitos/patología , Humanos , Riñón/metabolismo , Riñón/patología , Hígado/citología , Hígado/metabolismo , Hígado/patología , Neoplasias Hepáticas/patología , Regeneración Hepática/fisiología , Masculino , Fenilalanina/uso terapéutico , Dosificación Radioterapéutica , Ratas , Ratas Wistar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...