1.
J Orthop ; 24: 131-134, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33679038

RESUMEN

In this study, we evaluate the mid-term functional and radiological outcomes of Ceramic on Metal Total Hip Arthroplasty (CoM THA) THA. 66 CoM THAs were performed between 2008 and 2010. These were evaluated and followed up in 2017-18, at a mean follow-up of 9 years to record the Oxford Hip Score [OHS] and whole blood Cobalt and Chrome levels. Our all cause revision rate was 4.5% (3 out of 66). At mid-term follow up, patients with CoM THAs are mostly asymptomatic with reasonable functional outcomes, we have reported similar revision rates in conjunction with raised blood metal ion levels and frequency of radiolucent lines.

2.
Hip Int ; 31(5): 644-648, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32157907

RESUMEN

BACKGROUND: The cause of recurrent dislocation following primary total hip arthroplasty (THA) is multifactorial. A re-dislocation rate of up-to 34% following revision is reported. The aim of this study was to determine the re-dislocation rates following revision for recurrent THR dislocation. METHODOLOGY: Patients who underwent revision for recurrent dislocation between January 2008 and January 2015 were identified. We identified the date and type of primary implant, overall number and reasons for dislocation, revision implant details and complication data. RESULTS: Over an 8-year period, 24 patients underwent revision. The median age was 77 (68-85) years, median time to first dislocation was 78 (23-160) months and median number of dislocations was 3 (2-4) with a mean follow-up of 18 months. Socket Mal-Orientation (10) and Abductor deficiency (5) were the main causes of recurrent dislocation. 21 patients (88%) underwent revision of both components, 1 patient underwent isolated cup revision and 2 patients had revision of acetabular component with insertion of a BioBall. There were no dislocations within 90 days of revision surgery. 4 patients had late dislocations (3 recurrent, 1 isolated). There was no significant increase risk of dislocation after revision surgery in the neck of femur group (p = 0.467). CONCLUSIONS: We report favourable outcomes for revision of both components for recurrent dislocation with no dislocations within 90 days. The overall late dislocation rate was 16.7%, however, these patients have settled following closed reduction. Due to its multifactorial aetiology, both component revision can be considered in this patient population.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Seguimiento , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/etiología , Luxación de la Cadera/cirugía , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA