Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Anal Methods ; 16(4): 558-565, 2024 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-38189092

RESUMEN

Background: The optimization of antimicrobial dosing plays a crucial role in improving the likelihood of achieving therapeutic success while reducing the risks associated with toxicity and antimicrobial resistance. Probenecid has shown significant potential in enhancing the serum exposure of phenoxymethylpenicillin, thereby allowing for lower doses of phenoxymethylpenicillin to achieve similar pharmacokinetic/pharmacodynamic (PK/PD) targets. We developed a triple quadrupole liquid chromatography mass spectrometry (TQ LC/MS) analysis of, phenoxymethylpenicillin, benzylpenicillin and probenecid using benzylpenicillin-d7 and probenecid-d14 as IS in single low-volumes of human serum, with improved limit of quantification to support therapeutic drug monitoring. Methods: Sample clean-up was performed by protein precipitation using acetonitrile. Reverse phase chromatography was performed using TQ LC/MS. The mobile phase consisted of 55% methanol in water + 0.1% formic acid, with a flow rate of 0.4 mL min-1. Antibiotic stability was assessed at different temperatures. Results: Chromatographic separation was achieved within 2 minutes, allowing simultaneous measurement of phenoxymethylpenicillin, benzylpenicillin and probenecid in a single 15 µL blood sample. Validation indicated linearity over the range 0.0015-10 mg L-1, with accuracy of 96-102% and a LLOQ of 0.01 mg L-1. All drugs demonstrated good stability under different storage conditions. Conclusion: The developed method is simple, rapid, accurate and clinically applicable for the quantification of phenoxymethylpenicillin, benzylpenicillin and probenecid in tandem.


Asunto(s)
Penicilina V , Probenecid , Humanos , Probenecid/farmacología , Espectrometría de Masas en Tándem/métodos , Antibacterianos/farmacología , Penicilina G
2.
ACS Sens ; 8(4): 1639-1647, 2023 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-36967522

RESUMEN

Microneedle lactate sensors may be used to continuously measure lactate concentration in the interstitial fluid in a minimally invasive and pain-free manner. First- and second-generation enzymatic sensors produce a redox-active product that is electrochemically sensed at the electrode surface. Direct electron transfer enzymes produce electrons directly as the product of enzymatic action; in this study, a direct electron transfer enzyme specific to lactate has been immobilized onto a microneedle surface to create lactate-sensing devices that function at low applied voltages (0.2 V). These devices have been validated in a small study of human volunteers; lactate concentrations were raised and lowered through physical exercise and subsequent rest. Lactazyme microneedle devices show good agreement with concurrently obtained and analyzed serum lactate levels.


Asunto(s)
Electrones , Ácido Láctico , Humanos , Electrodos , Transporte de Electrón , Sujetos de Investigación
3.
Anal Methods ; 15(6): 829-836, 2023 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-36727437

RESUMEN

Background: enhanced methods of therapeutic drug monitoring are required to support the individualisation of antibiotic dosing based on pharmacokinetics (PK) parameters. PK studies can be hampered by limited total serum volume, especially in neonates, or by sensitivity in the case of critically ill patients. We aimed to develop a liquid chromatography-mass spectrometry (LC/MS) analysis of benzylpenicillin, phenoxymethylpenicillin and amoxicillin in single low volumes of human serum and interstitial fluid (ISF) samples, with an improved limit of detection (LOD) and limit of quantification (LOQ), compared with previously published assays. Methods: sample clean-up was performed by protein precipitation using acetonitrile. Reverse phase chromatography was performed using triple quadrupole LC/MS. The mobile phase consisted of 55% methanol in water + 0.1% formic acid, with a flow rate of 0.4 mL min-1. Antibiotics stability was assessed at different temperatures. Results: chromatographic separation was achieved within 3 minutes for all analytes. Three common penicillins can now be measured in a single low-volume blood and ISF sample (15 µL) for the first time. Validation has demonstrated the method to be linear over the range 0.0015-10 mg L-1, with an accuracy of 93-104% and high sensitivity, with LOD ≈ 0.003 mg L-1 and LOQ ≈ 0.01 mg L-1 for all three analytes, which is critical for use in dose optimisation/individualisation. All evaluated penicillins indicated good stability at room temperature over 4 h, at (4 °C) over 24 h and at -80 °C for 6 months. Conclusion: the developed method is simple, rapid, accurate and clinically applicable for the quantification of three penicillin classes.


Asunto(s)
Líquido Extracelular , Espectrometría de Masas en Tándem , Recién Nacido , Humanos , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Antibacterianos/química , Antibacterianos/farmacocinética , Amoxicilina , Penicilinas , Monobactamas
4.
Nanoscale ; 15(7): 3243-3254, 2023 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-36723120

RESUMEN

We demonstrate a novel and versatile sensing platform, based on electrolyte-gated graphene field-effect transistors, for easy, low-cost and scalable production of chemical sensor test strips. The Lab-on-PCB platform is enabled by low-boiling, low-surface-tension sprayable graphene ink deposited on a substrate manufactured using a commercial printed circuit board process. We demonstrate the versatility of the platform by sensing pH and Na+ concentrations in an aqueous solution, achieving a sensitivity of 143 ± 4 µA per pH and 131 ± 5 µA per log10Na+, respectively, in line with state-of-the-art graphene chemical sensing performance.

5.
Anal Methods ; 15(6): 746-751, 2023 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-36655876

RESUMEN

Background: therapeutic drug monitoring is a crucial aspect of the management of hospitalized patients. The correct dosage of antibiotics is imperative to ensure their adequate exposure specially in critically ill patients. The aim of this study is to establish and validate a robust and fast liquid chromatography-tandem mass spectrometry (LC/MS) method for the simultaneous quantification of two important antibiotics in critically ill patients, cefiderocol and meropenem in human plasma. Methods: sample clean-up was performed by protein precipitation using acetonitrile. Reverse phase chromatography was performed using triple quadrupole LC/MS. The mobile phase was consisted of 55% methanol in water +0.1% formic acid, with flow rate of 0.4 ml min-1. Antibiotics stability was assessed at different temperatures. Serum protein binding was assessed using ultrafiltration devices. Results: chromatographic separation was achieved within 1.5 minutes for all analytes. Validation has demonstrated the method to be linear over the range 0.0025-50 mg L-1 for cefiderocol and 0.00028-50 mg L-1 for meropenem, with accuracy of 94-101% and highly sensitive, with LLOQ ≈ 0.02 mg L-1 and 0.003 mg L-1 for cefiderocol and meropenem, respectively. Both cefiderocol and meropenem showed a good stability at room temperature over 6 h, and at (4 °C) over 24 h. Cefiderocol and meropenem demonstrated a protein binding of 49-60% and 98%, respectively in human plasma. Conclusion: the developed method is simple, rapid, accurate and clinically applicable for the quantification of cefiderocol and meropenem.


Asunto(s)
Enfermedad Crítica , Espectrometría de Masas en Tándem , Humanos , Meropenem , Espectrometría de Masas en Tándem/métodos , Antibacterianos/química , Cromatografía Liquida/métodos , Cefiderocol
6.
Methods Mol Biol ; 2570: 271-280, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36156789

RESUMEN

Electrochemical aptamer-based (E-AB) sensors using conformational change-induced electron transfer kinetics are sensitive, reagent-less, and cost-effective tools for molecular sensing. Current advances in this technology can allow continuous drug pharmacokinetic monitoring in living animals (Dauphin-Ducharme et al., ACS Sens 4(10):2832-2837, 2019; Idili et al., Chem Sci 10(35):8164-8170, 2019), as well as automated analysis of hormone pulsatility (Liang et al., Nat Commun 10(1):852, 2019). In this chapter, we provide the methodology for an automated E-AB conformational change-based robotic sensing platform. By using an open-source programmable robotic system, this method can be adapted to a wide range of experimental scenarios.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Procedimientos Quirúrgicos Robotizados , Animales , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Electrodos , Oro/química , Hormonas
7.
ACS Omega ; 7(44): 39848-39859, 2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36385833

RESUMEN

This work aims at evaluating a utilization of diverse clay mineral/gold nanoparticles/acetylcholinesterase (clay/AuNPs/AChE) biosensors by using principal component analysis (PCA) for the discrimination of pesticide types and their concentration levels both in the synthetic and real samples. Applications of simple and low-cost clay/AuNP composites of different characteristics as modified-electrode materials are highlighted. Four types of clay minerals, namely, platelike kaolinite (Kaol: 1:1 aluminum phyllosilicate), globular montmorillonite (Mt: 2:1 aluminum phyllosilicate), globular bentonite (Bent: 2:1 aluminum phyllosilicate), and fibrous sepiolite (Sep: 2:1 inverted ribbons of magnesium phyllosilicate), were selected as the base materials. Due to the distinct characteristics of the selected clay, the derived clay/AuNP composites resulted in different physical morphologies, AuNP sizes and loadings, matrix hydrophobicity, and active AChE loading per electrode. These, in turn, caused divergent electrochemical responses for the pesticide determination; hence, no other enzymes apart from AChE were necessary for the fabrication of distinct biosensors. Physical and chemical characterizations of clay/AuNPs were conducted using scanning electron microscopy, transmission electron microscopy, thermogravimetric analysis, and X-ray photoelectron spectroscopy techniques. The electrochemical information was recorded by cyclic voltammetry and amperometry techniques. The enzyme inhibition results obtained from the pesticides were treated and used as input data to obtain PCA results. The four fabricated clay/AuNPs/AChE biosensors were able to discriminate chlorpyrifos and carbaryl and their concentration levels for synthetic pesticides and real samples. It was disclosed that a high enzyme inhibition and a high hydrophobic modified-electrode material affect a highly sensitive pesticide biosensor. The hydrophobic/hydrophilic character of the modified-electrode material plays a major role in discriminating the pesticide types and their concentration levels by the proposed single-enzyme sensor system. The PCA results illustrated that PC2 described the different types of pesticides, and PC1 showed the level of pesticide concentration with high first two principal components. The mixed pesticides could be identified at an especially low total concentration of 0.5 ng/mL in real samples.

8.
Mikrochim Acta ; 189(5): 180, 2022 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-35391571

RESUMEN

Dopamine (DA), epinephrine (EP), and norepinephrine (NEP) are the main catecholamine of clinical interest, as they play crucial roles in the regulation of nervous and cardiovascular systems and are involved in some brain behaviors, such as stress, panic, anxiety, and depression. Therefore, there is an urgent need for a reliable sensing device able to provide their continuous monitoring in a minimally invasive manner. In this work, the first highly nanoporous gold (h-nPG) microneedle-based sensor is presented for continuous monitoring of catecholamine in interstitial fluid (ISF). The h-nPG microneedle-based gold electrode was prepared by a simple electrochemical self-templating method that involves two steps, gold electrodeposition and hydrogen bubbling at the electrode surface, realized by sweeping the potential between + 0.8 V and 0 V vs Ag/AgCl for 25 scans in a 10 mM HAuCl4 solution containing 2.5 M NH4Cl, and successively applying a fixed potential of - 2 V vs Ag/AgCl for 60 s. The resulting microneedle-based h-nPG sensor displays an interference-free total catecholamine detection expressed as NEP concentration, with a very low LOD of 100 nM, excellent sensitivity and stability, and fast response time (< 4 s). The performance of the h-nPG microneedle array sensor was successively assessed in artificial ISF and in a hydrogel skin model at typical physiological concentrations.


Asunto(s)
Oro , Nanoporos , Catecolaminas , Electrodos , Agujas
9.
Trends Biotechnol ; 38(11): 1262-1277, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33058758

RESUMEN

Recent technological advances have stimulated efforts to bring personalized medicine into practice. Yet, traditional application fields like therapeutic drug monitoring (TDM) have remained rather under-appreciated. Owing to clear dose-response relationships, TDM could improve patient outcomes and reduce healthcare costs. While chromatography-based routine practices are restricted due to high costs and turnaround times, biosensors overcome these limitations by offering on-site analysis. Nevertheless, sensor-based approaches have yet to break through for clinical TDM applications, due to the gap between scientific and clinical communities. We provide a critical overview of current TDM practices, followed by a TDM guideline to establish a common ground across disciplines. Finally, we discuss how the translation of sensor systems for TDM can be facilitated, by highlighting the challenges and opportunities.


Asunto(s)
Técnicas Biosensibles , Monitoreo de Drogas , Monitoreo de Drogas/instrumentación , Monitoreo de Drogas/métodos , Humanos , Medicina de Precisión
10.
Chem Sci ; 11(17): 4467-4474, 2020 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-34122904

RESUMEN

Although RNA aptamers can show comparable or better specificity and affinity to antibodies and have the advantage of being able to access different live cell compartments, they are often much less stable in vivo. We report here the first aptamer that binds human retinoblastoma protein (RB) and is stable in live cells. RB is both a key protein in cell cycle control and also a tumour suppressor. The aptamer was selected from an RNA library against a unique 12-residue helical peptide derived from RB rather than the whole protein molecule. It binds RB with high affinity (K d = 5.1 ± 0.1 nM) and is a putative RNA G-quadruplex structure formed by an 18-nucleotide sequence (18E16 - GGA GGG UGG AGG GAA GGG), which may account for its high stability. Confocal fluorescence microscopy of live cells transfected with the aptamer shows it is stable intracellularly and efficient in entering the nucleus where an analogous antibody was inaccessible. The findings demonstrate this aptamer is an advanced probe for RB in live cell applications.

11.
Nanoscale Adv ; 2(12): 5666-5681, 2020 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-36133855

RESUMEN

Gold nanoparticles are becoming a promising platform for the delivery of drugs to treat neurodegenerative diseases. Parkinson's disease, associated with the aggregation of α-synuclein, is a condition that results in dysfunctional neuronal cells leading to their degeneration and death. Oxidative stress has been strongly implicated as a common feature in this process. The limited efficacy of the traditional therapies and the development of associated severe side effects present an unmet need for preventive and adjuvant therapies. The organosulfur compound lipoic acid, naturally located in the mitochondria, plays a powerful antioxidative role against oxidative stress. However, the efficacy is limited by its low physiological concentration, and the administration is affected by its short half-life and bioavailability due to hepatic degradation. Here we exploited the drug delivery potential of gold nanoparticles to assemble lipoic acid, and administered the system into SH-SY5Y cells, a cellular model commonly used to study Parkinson's disease. We tested the nanoconjugates of GNPs-LA, under an oxidative environment induced by gold nanoparticle/α-synuclein conjugates (GNPs-α-Syn). GNPs-LA were found to be biocompatible and capable of restoring the cell damage caused by high-level reactive oxygen species generated by excessive oxidative stress in the cellular environment. We conclude that GNPs-LA may serve as promising drug delivery vehicles conveying antioxidant molecules for the treatment of Parkinson's disease.

12.
Environ Technol ; 41(1): 71-85, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29923786

RESUMEN

In the present study, locally isolated Rhodococcus strains were attempted as biological tools for methyl red removal, a mutagenic azo dye posing threat to the environment if left untreated. Rhodococcus strain UCC 0016 demonstrated superior methyl red-decolourizing activity of 100% after 24 h at static condition in comparison to Rhodococcus strain UCC 0008 which recorded 65% decolourization after 72 h. Optimization of physicochemical parameters at 30°C, pH 7 and supplementing glucose as the carbon source resulted in improved methyl red-decolourizing activity at static condition and reduced the time taken to achieve complete decolourization by 80%. Higher concentration of methyl red (5 g/L) was able to be decolourized completely within 10 h by adopting the technology of immobilization. The encapsulated cells of Rhodococcus strain UCC 0016 demonstrated higher substrate affinity (Km = 0.6995 g/L) and an accelerated rate of disappearance of methyl red (Vmax = 0.3203 g/L/h) compared to the free cells. Furthermore, the gellan gum beads could be reused up to nine batches without substantial loss in the catalytic activity indicating the economic importance of this protocol. Analysis of methyl red degradation products revealed no germination inhibition on Triticum aestivum and Vigna radiata demonstrating complete toxicity removal of the parent dye after biological treatment. The occurrence of new and altered peaks (UV-Vis and FTIR) further supported the notion that the removal of methyl red by Rhodococcus strain UCC 0016 was indeed through biodegradation. Therefore, this strain has a huge potential as a candidate for efficient bioremediation of wastewater containing methyl red.


Asunto(s)
Rhodococcus , Esguinces y Distensiones , Compuestos Azo , Biodegradación Ambiental , Colorantes , Humanos
13.
Chemistry ; 25(46): 10895-10906, 2019 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-31127668

RESUMEN

The first example of an octadentate gadolinium unit based on DO3A (hydration number q=1) with a dithiocarbamate tether has been designed and attached to the surface of gold nanoparticles (around 4.4 nm in diameter). In addition to the superior robustness of this attachment, the restricted rotation of the Gd complex on the nanoparticle surface leads to a dramatic increase in relaxivity (r1 ) from 4.0 mm-1 s-1 in unbound form to 34.3 mm-1 s-1 (at 10 MHz, 37 °C) and 22±2 mm-1 s-1 (at 63.87 MHz, 25 °C) when immobilised on the surface. The one-pot synthetic route provides a straightforward and versatile way of preparing a range of multifunctional gold nanoparticles. The incorporation of additional surface units for biocompatibility (PEG and thioglucose units) and targeting (folic acid) leads to little detrimental effect on the high relaxivity observed for these non-toxic multifunctional materials. In addition to the passive targeting attributed to gold nanoparticles, the inclusion of a unit capable of targeting the folate receptors overexpressed by cancer cells, such as HeLa cells, illustrates the potential of these assemblies.

14.
Nanotheranostics ; 3(1): 89-102, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30899637

RESUMEN

Endoscopy is the gold standard investigation in the diagnosis of gastrointestinal cancers and the management of early and pre-malignant lesions either by resection or ablation. Recently gold nanoparticles have shown promise in cancer diagnosis and therapeutics (theranostics). The combination of multifunctional gold nanoparticles with near infrared fluorescence endoscopy for accurate mapping of early or pre-malignant lesions can potentially enhance diagnostic efficiency while precisely directing endoscopic near infrared photothermal therapy for established cancers. The integration of endoscopy with near infrared fluorescence imaging and photothermal therapy was aided by the accumulation of our multifunctionalized PEG-GNR-Cy5.5-anti-EGFR-antibody gold nanorods within gastrointestinal tumor xenografts in BALB/c mice. Control mice (with tumors) received either gold nanorods or photothermal therapy, while study mice received both treatment modalities. Local (tumor-centric) and systemic effects were examined for 30 days. Clear endoscopic near infrared fluorescence signals were observed emanating specifically from tumor sites and these corresponded precisely to the tumor margins. Endoscopic fluorescence-guided near infrared photothermal therapy successfully induced tumor ablations in all 20 mice studied, with complete histological clearance and minimal collateral damage. Multi-source analysis from histology, electron microscopy, mass spectrometry, blood, clinical evaluation, psychosocial and weight monitoring demonstrated the inherent safety of this technology. The combination of this innovative nanotechnology with gold standard clinical practice will be of value in enhancing the early optical detection of gastrointestinal cancers and a useful adjunct for its therapy.


Asunto(s)
Oro , Hipertermia Inducida , Laparoscopía , Nanopartículas del Metal , Nanotubos/química , Neoplasias Experimentales , Imagen Óptica , Fototerapia , Animales , Línea Celular Tumoral , Oro/química , Oro/farmacología , Humanos , Masculino , Nanopartículas del Metal/química , Nanopartículas del Metal/uso terapéutico , Ratones , Ratones Desnudos , Neoplasias Experimentales/diagnóstico por imagen , Neoplasias Experimentales/terapia , Ensayos Antitumor por Modelo de Xenoinjerto
15.
Chembiochem ; 20(17): 2198-2202, 2019 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-30897259

RESUMEN

Theranostics involves finding the biomarkers of a disease, fighting them through site specific drug delivery and following them for prognosis of the disease. Microneedle array technology has been used for drug delivery and extended for continuous monitoring of analytes present in the skin compartment. We envisage the use of microneedle arrays for future theranostic applications. The potential of combining microneedle array-based drug delivery and diagnostics as part of closed-loop control system for the management of diseases and delivery of precision drugs in individual patients is reported in this paper.


Asunto(s)
Sistemas de Liberación de Medicamentos/tendencias , Nanomedicina Teranóstica/tendencias , Animales , Manejo de la Enfermedad , Sistemas de Liberación de Medicamentos/instrumentación , Sistemas de Liberación de Medicamentos/métodos , Humanos , Medicina de Precisión
16.
ACS Nano ; 13(3): 2913-2926, 2019 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-30829469

RESUMEN

Biomaterial substrates can be engineered to present topographical signals to cells which, through interactions between the material and active components of the cell membrane, regulate key cellular processes and guide cell fate decisions. However, targeting mechanoresponsive elements that reside within the intracellular domain is a concept that has only recently emerged. Here, we show that mesoporous silicon nanoneedle arrays interact simultaneously with the cell membrane, cytoskeleton, and nucleus of primary human cells, generating distinct responses at each of these cellular compartments. Specifically, nanoneedles inhibit focal adhesion maturation at the membrane, reduce tension in the cytoskeleton, and lead to remodeling of the nuclear envelope at sites of impingement. The combined changes in actin cytoskeleton assembly, expression and segregation of the nuclear lamina, and localization of Yes-associated protein (YAP) correlate differently from what is canonically observed upon stimulation at the cell membrane, revealing that biophysical cues directed to the intracellular space can generate heretofore unobserved mechanosensory responses. These findings highlight the ability of nanoneedles to study and direct the phenotype of large cell populations simultaneously, through biophysical interactions with multiple mechanoresponsive components.


Asunto(s)
Mecanotransducción Celular/efectos de los fármacos , Nanoestructuras/química , Silicio/farmacología , Adhesión Celular/efectos de los fármacos , Células Cultivadas , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Humanos , Agujas , Tamaño de la Partícula , Porosidad , Silicio/química , Propiedades de Superficie
17.
Nat Commun ; 10(1): 852, 2019 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-30787284

RESUMEN

Normal reproductive functioning is critically dependent on pulsatile secretion of luteinising hormone (LH). Assessment of LH pulsatility is important for the clinical diagnosis of reproductive disorders, but current methods are hampered by frequent blood sampling coupled to expensive serial immunochemical analysis. Here, we report the development and application of a Robotic APTamer-enabled Electrochemical Reader (RAPTER) electrochemical analysis system to determine LH pulsatility. Through selective evolution of ligands by exponential enrichment (SELEX), we identify DNA aptamers that bind specifically to LH and not to related hormones. The aptamers are integrated into electrochemical aptamer-based (E-AB) sensors on a robotic platform. E-AB enables rapid, sensitive and repeatable determination of LH concentration profiles. Bayesian Spectrum Analysis is applied to determine LH pulsatility in three distinct patient cohorts. This technology has the potential to transform the clinical care of patients with reproductive disorders and could be developed to allow real-time in vivo hormone monitoring.

18.
Environ Technol ; 40(3): 386-398, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29032742

RESUMEN

The capability of the crude extract of Rhodococcus UKMP-5M was enhanced by adopting the technology of immobilization. Among the matrices screened to encapsulate the crude extract, gellan gum emerged as the most suitable immobilization material, exceeding the activity of cyanide-degrading enzyme by 61% and 361% in comparison to alginate carrier and non-immobilized crude extract, respectively. Improved bead mechanical strength which supported higher biocatalyst activity by 63% was observed when concentration of gellan gum, concentration of calcium chloride, number of beads and bead size were optimized. The immobilized crude extract demonstrated higher tolerance towards broad range of pH (5-10) and temperature (30°C-40°C), superior cyanide-degrading activity over time and improved storage stability by maintaining 76% of its initial activity after 30 days at 4°C. Furthermore, repeated use of the gellan gum beads up to 20 batches without substantial loss in the catalytic activity was documented in the present study, indicating that the durability of the beads and the stability of the enzyme are both above adequate. Collectively, the findings reported here revealed that the utilization of the encapsulated crude extract of Rhodococcus UKMP-5M can be considered as a novel attempt to develop an environmentally favourable and financially viable method in cyanide biodegradation.


Asunto(s)
Rhodococcus , Alginatos , Biodegradación Ambiental , Mezclas Complejas , Cianuros , Enzimas Inmovilizadas , Concentración de Iones de Hidrógeno , Temperatura
19.
Lancet Digit Health ; 1(7): e335-e343, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-33323208

RESUMEN

BACKGROUND: Enhanced methods of drug monitoring are required to support the individualisation of antibiotic dosing. We report the first-in-human evaluation of real-time phenoxymethylpenicillin monitoring using a minimally invasive microneedle-based ß-lactam biosensor in healthy volunteers. METHODS: This first-in-human, proof-of-concept study was done at the National Institute of Health Research/Wellcome Trust Imperial Clinical Research Facility (Imperial College London, London, UK). The study was approved by London-Harrow Regional Ethics Committee. Volunteers were identified through emails sent to a healthy volunteer database from the Imperial College Clinical Research Facility. Volunteers, who had to be older than 18 years, were excluded if they had evidence of active infection, allergies to penicillin, were at high risk of skin infection, or presented with anaemia during screening. Participants wore a solid microneedle ß-lactam biosensor for up to 6 h while being dosed at steady state with oral phenoxymethylpenicillin (five 500 mg doses every 6 h). On arrival at the study centre, two microneedle sensors were applied to the participant's forearm. Blood samples (via cannula, at -30, 0, 10, 20, 30, 45, 60, 90, 120, 150, 180, 210, 240 min) and extracellular fluid (ECF; via microdialysis, every 15 min) pharmacokinetic (PK) samples were taken during one dosing interval. Phenoxymethylpenicillin concentration data obtained from the microneedles were calibrated using locally estimated scatter plot smoothing and compared with free-blood and microdialysis (gold standard) data. Phenoxymethylpenicillin PK for each method was evaluated using non-compartmental analysis. Area under the concentration-time curve (AUC), maximum concentration, and time to maximum concentration were compared. Bias and limits of agreement were investigated with Bland-Altman plots. Microneedle biosensor limits of detection were estimated. The study was registered with ClinicalTrials.gov, number NCT03847610. FINDINGS: Ten healthy volunteers participated in the study. Mean age was 42 years (SD 14). Seven (70%) were men. Microdialysis and microneedle results were similar for phenoxymethylpenicillin ECF maximum concentration (0·74 mg/L vs 0·64 mg/L; 95% CI -0·24 to 0·44; p=0·53), time to maximum concentration (1·18 h vs 1·10 h; -0·52 to 0·67; p=0·79), and AUC (1·54 mg × h/L vs 1·67 mg × h/L; -1·10 to 0·85; p=0·79). In total, 440 time points were compared with mean difference between measurements -0·16 mg/L (95% CI -1·30 to 0·82). Mean phenoxymethylpenicillin AUCs for free serum and microneedle PK were similar (1·77 mg × h/L [SD 0·59] vs 1·67 mg × h/L [1·00]; -0·77 to 0·97; p=0·81). Median coefficient of variation between sensors within individuals was 7% (IQR 4-17). Limit of detection for the microneedles was estimated at 0·17 mg/L. INTERPRETATION: This study is proof-of-concept of real-time, microneedle sensing of penicillin in vivo. Future work will explore microneedle use in patient populations, their role in data generation to inform dosing recommendations, and their incorporation into closed-loop control systems for automated drug delivery. FUNDING: National Institute for Health Research Imperial Biomedical Research Centre, Mérieux Foundation.


Asunto(s)
Antibacterianos , Técnicas Biosensibles , Monitoreo de Drogas , Voluntarios Sanos , Agujas , Penicilina V , Adulto , Antibacterianos/administración & dosificación , Antibacterianos/farmacocinética , Líquido Extracelular , Femenino , Humanos , Londres , Masculino , Microdiálisis , Penicilina V/administración & dosificación , Penicilina V/farmacocinética
20.
Adv Funct Mater ; 29(1): 1804798, 2019 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-32733177

RESUMEN

Commercially available metal inks are mainly designed for planar substrates (for example, polyethylene terephthalate foils or ceramics), and they contain hydrophobic polymer binders that fill the pores in fabrics when printed, thus resulting in hydrophobic electrodes. Here, a low-cost binder-free method for the metallization of woven and nonwoven fabrics is presented that preserves the 3D structure and hydrophilicity of the substrate. Metals such as Au, Ag, and Pt are grown autocatalytically, using metal salts, inside the fibrous network of fabrics at room temperature in a two-step process, with a water-based silicon particle ink acting as precursor. Using this method, (patterned) metallized fabrics are being enabled to be produced with low electrical resistance (less than 3.5 Ω sq-1). In addition to fabrics, the method is also compatible with other 3D hydrophilic substrates such as nitrocellulose membranes. The versatility of this method is demonstrated by producing coil antennas for wireless energy harvesting, Ag-Zn batteries for energy storage, electrochemical biosensors for the detection of DNA/proteins, and as a substrate for optical sensing by surface enhanced Raman spectroscopy. In the future, this method of metallization may pave the way for new classes of high-performance devices using low-cost fabrics.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...