Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Environ Int ; 190: 108836, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38917624

RESUMEN

The use of cleaning and disinfecting products both at work and at home increased during the COVID-19 pandemic. Those products often include surfactants, acids/bases, carcinogens such as chloroform, and endocrine-disrupting chemicals, such as cyclosiloxanes, phthalates, and synthetic fragrances, which may cause harmful health effects among professional cleaners as well as among people exposed at home or in their workplaces. The aim of this study was to synthesize the effects of the commonly used chemical, surface cleaning and disinfecting products on indoor air quality, focusing on chemical and particulate matter pollutants, exposure, and human health in residential and public buildings. We also provide a summary of recommendations to avoid harmful exposure and suggest future research directions. PubMed, Google Scholar, Scopus, and Web of Science (WoS) were used to search the literature. Analysis of the literature revealed that the use of cleaning products and disinfectants increase occupants' exposure to a variety of harmful chemical air contaminants and to particulate matter. Occupational exposure to cleaning and disinfectant products has been linked to an increased risk of asthma and rhinitis. Residential exposure to cleaning products has been shown to have an adverse effect on respiratory health, particularly on asthma onset, and on the occurrence of asthma(-like) symptoms among children and adults. Efforts to reduce occupants' exposure to cleaning chemicals will require lowering the content of hazardous substances in cleaning products and improving ventilation during and after cleaning. Experimentally examined, best cleaning practices as well as careful selection of cleaning products can minimize the burden of harmful air pollutant exposure indoors. In addition, indirect ways to reduce exposure include increasing people's awareness of the harmfulness of cleaning chemicals and of safe cleaning practices, as well as clear labelling of cleaning and disinfecting products.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Detergentes , Desinfectantes , Contaminación del Aire Interior/análisis , Humanos , Desinfectantes/análisis , Detergentes/análisis , COVID-19/prevención & control , Exposición Profesional , SARS-CoV-2 , Exposición a Riesgos Ambientales , Material Particulado/análisis
2.
Indoor Air ; 31(5): 1563-1576, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33939214

RESUMEN

The emissions of volatile organic compounds (VOCs) from building materials may significantly contribute to indoor air pollution, and VOCs have been associated with odor annoyance and adverse health effects. Wood materials together with coatings are commonly used indoors for furniture and large surfaces such as walls, floors, and ceilings. This leads to high surface-to-volume ratios, and therefore, these materials may participate remarkably to the VOC levels of indoor environment. We studied emissions of VOCs and carbonyl compounds from pinewood (Pinus sylvestris) boards of 10% and 16% moisture contents (MC) with three paints using small-scale test chambers (27 L). The emissions from uncoated pinewood and paints (on a glass substrate) were tested as references. The 28-day experiment showed that the VOC emissions from uncoated pinewood were lower from sample with 16% MC. Painted pinewood samples showed lower emissions compared to paints on glass substrate. Additionally, paints on 16% MC pinewood exhibited lower emissions than on drier 10% MC wood. The emissions from painted pinewood samples were dominated by paint-based compounds, but the share of wood-based compounds increased over time. However, we noticed differences between the paints, and wood-based emissions were clearly higher with the most permeable paint.


Asunto(s)
Contaminación del Aire Interior , Pintura , Compuestos Orgánicos Volátiles/análisis , Madera , Materiales de Construcción , Monitoreo del Ambiente , Diseño Interior y Mobiliario , Pinus sylvestris
3.
Indoor Air ; 29(6): 903-912, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31348556

RESUMEN

Degrading 2-ethylhexyl-containing PVC floorings (eg DEHP-PVC floorings) and adhesives emit 2-ethylhexanol (2-EH) in the indoor air. The danger of flooring degradation comes from exposing occupants to harmful phthalates plasticisers (eg DEHP), but not from 2-EH as such. Since the EU banned the use of phthalates in sensitive applications, the market is shifting to use DEHP-free and alternative types of plasticisers in PVC products. However, data on emissions from DEHP-free PVC floorings are scarce. This study aimed at assessing the surface and bulk emissions of two DEHP-free PVC floorings over three years. The floorings were glued on the screed layer of concrete casts at 75%, 85%, and 95% RH. The volatile organic compounds (VOCs) were actively sampled using FLEC (surface emissions) and micro-chamber/thermal extractor (µ-CTE, bulk emissions) onto Tenax TA adsorbents and analyzed with TD-GC-MS. 2-EH, C9-alcohols, and total volatile organic compound (TVOC) emissions are reported. Emissions at 75% and 85% RH were similar. As expected, the highest emissions occurred at 95% RH. 2-EH emissions originated from the adhesive. Because the two DEHP-free floorings tested emitted C9-alcohols at all tested RH, it makes the detection of flooring degradation harder, particularly if the adhesive used does not emit 2-EH.


Asunto(s)
Contaminación del Aire Interior/análisis , Exposición a Riesgos Ambientales/análisis , Pisos y Cubiertas de Piso , Adhesivos/análisis , Alcoholes/análisis , Monitoreo del Ambiente , Hexanoles/análisis , Humanos , Plastificantes/análisis , Compuestos Orgánicos Volátiles/análisis
4.
Toxins (Basel) ; 10(11)2018 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-30413106

RESUMEN

A novel, objective, and rapid computed motility inhibition (CMI) assay was developed to identify and assess sublethal injury in toxin-exposed boar spermatozoa and compared with a subjective visual motility inhibition (VMI) assay. The CMI values were calculated from digital micrographic videos using a custom MATLAB® script by contrasting the motility index values of each experiment with those of the background and control experiments. Following a comparison of the CMI and VMI assays results, it was determined that their agreement depended on the shape of the dose-response curve. Toxins that exhibited a steep slope were indicative of good agreement between the assays. Those depicted by a gentle decline in the slope of the dose-response curve, the CMI assay were shown to be two times more sensitive than the VMI assay. The CMI assay was highly sensitive to the inhibition of mitochondrial function and glucose transport activity by sublethal doses of toxins and to disruption of cellular cation homeostasis by carrier ionophoric toxins, when compared to the cytotoxicity and lethal toxicity assays (i.e., that evaluated the inhibition of cell proliferation in somatic cell lines (FL, PK-15, and MNA cells)) and disruption to spermatozoa membrane integrity. The CMI assay recognized subtle sublethal toxicity changes in metabolism, manifested as a decrease in boar spermatozoa motility. Thus, it was feasible to effectively compare the objectively-measured numerical values for motility inhibition using the CMI assay against those reflecting lethal damage in the spermatozoa cells and somatic cell lines using a cytotoxicity assay.


Asunto(s)
Motilidad Espermática/efectos de los fármacos , Espermatozoides/efectos de los fármacos , Pruebas de Toxicidad/métodos , Contaminación del Aire Interior/efectos adversos , Animales , Bacterias , Técnicas Biosensibles , Carbonil Cianuro p-Trifluorometoxifenil Hidrazona/toxicidad , Gatos , Línea Celular , Hongos , Masculino , Ratones , Dicromato de Potasio/toxicidad , Espermatozoides/fisiología , Porcinos , Toxinas Biológicas/toxicidad , Triclosán/toxicidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA