Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
1.
Int Orthop ; 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39172271

RESUMEN

PURPOSE: Total Elbow Arthroplasty (TEA) was first developed to treat severe rheumatoid arthritis, but its uses have grown to encompass end-stage osteoarthritis, post-traumatic arthritis, and distal humeral fractures. This study analyzes indications changes, long-term survival, complications, and post-operative functional results of the Coonrad-Morrey prostheses, enhancing the existing literature on this technique and substantial case history. METHODS: We included 122 arthroplasties in 117 patients, 28 males and 89 females (mean age of 67 years) treated in our hospital between 2002 and 2016. Minimum follow-up was four years. We collect functional parameters of 48 patients (51 elbows), due to death of patients due to old age and loss at follow-up. RESULTS: Survival rate at five years was 90%, 85% at 10 years and 83% at 15 years. The overall medium Mayo elbow score was 79.7 ± 18.3 with the highest result in osteoarthritis patients (p < 0.005); QuickDASH score was 33.1 ± 25.5 with the worse result in rheumatoid group. Average post-operative arc of motion (ROM) was 95°±27°. There were complications in 46 out of 122 cases (37.7%) and revision surgeries were performed in 12 of them (9.8%): seven aseptic loosening, four late septic loosening, one bushing wear. In 27 instances (22.1%) was reported ulnar nerve involvement. CONCLUSION: Coonrad-Morrey prosthesis has shown satisfactory clinical results in the treatment of a wide range of pathologies. The long-term implant survivorship was satisfactory, yet the occurrence of failures and complications cannot be overlooked, above all the ulnar nerve paresthesia. There was a good recovery in quality of life, pain-free with limited residual limb disability.

2.
Arthroplasty ; 6(1): 27, 2024 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-38824601

RESUMEN

BACKGROUND: In the present study, the surgeon aimed to align the stem at 5° to 25° in anteversion. The robotic technology was used to measure stem anteversion with respect to proximal femur anteversion at different levels down the femur. METHODS: A total of 102 consecutive patients underwent robotic-arm-assisted total hip arthroplasty (RTHA). 3D CT-based preoperative planning was performed to determine femoral neck version (FNV), posterior cortex anteversion (PCA), anterior cortex anteversion (ACA), and femoral metaphyseal axis anteversion (MAA) at 3 different levels: D (10 mm above lesser trochanter), E (the midpoint of the planned neck resection line) and F (head-neck junction). The robotic system was used to define and measure stem anteversion during surgery. RESULTS: Mean FNV was 6.6° (SD: 8.8°) and the mean MAA was consistently significantly higher than FNV, growing progressively from proximal to distal. Mean SV was 16.4° (SD: 4.7°). There was no statistically significant difference (P = 0.16) between SV and MAA at the most distal measured level. In 96.1% cases, the stem was positioned inside the 5°-25° anteversion range. CONCLUSIONS: Femoral anteversion progressively increased from neck to proximal metaphysis. Aligning the stem close to femoral anteversion 10 mm above the lesser trochanter often led to the desired component anteversion.

3.
Knee Surg Sports Traumatol Arthrosc ; 32(6): 1539-1547, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38572678

RESUMEN

PURPOSE: Computed tomography (CT)-based robotic system for total knee arthroplasty (TKA) has shown improved accuracy compared to conventional. This study was designed to (1) confirm the accuracy of the robotic system in achieving the plan and (2) establish the alignment and positioning deviation between final components and planning, by measuring the discrepancy between final implant alignment and the corresponding planned cut. METHODS: Ninety-six cementless robotic-arm assisted (RA) TKAs were assessed. Bone resections were performed using the haptically controlled robotic arm. Alignment in the coronal and sagittal plane and resection depth of the distal femoral and proximal tibial cuts were recorded with a navigation planar probe. After final components were impacted, the probe was positioned on each implant surface to determine its alignment and positioning. RESULTS: The mean tibial resections and implanted tibial component's positioning were 0.4 mm (standard deviation, SD: 0.6) and 0.9 mm (SD: 0.8), respectively, higher than planned (p < 0.01). The tibial sagittal cut had 19/96 cases (19.8%) of ±1° outliers from plan. In 40/96 cases (41.7%), the tibial component was more prominent than planned of more than 1 mm. The mean femoral resections and impacted femoral component's positioning was 0.1 mm (SD: 0.8) and 0.2 mm (SD: 0.7), respectively, higher than planned. In 23/96 cases (24.0%), the femoral sagittal cut and femoral component coronal alignment deviated more than ±1° from plan. CONCLUSIONS: The computed tomography-based robotic-assisted TKA system showed good accuracy regarding bone preparation and component's positioning relative to the planning. Cementless tibial component impaction resulted in the most deviation from plan, with a large proportion of cases resulting in being more prominent than planned. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Tibia , Tomografía Computarizada por Rayos X , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Procedimientos Quirúrgicos Robotizados/métodos , Femenino , Masculino , Anciano , Tibia/cirugía , Tibia/diagnóstico por imagen , Persona de Mediana Edad , Anciano de 80 o más Años , Fémur/cirugía , Fémur/diagnóstico por imagen , Prótesis de la Rodilla
4.
J Arthroplasty ; 39(8S1): S224-S229, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38360280

RESUMEN

BACKGROUND: A core tenet of total knee arthroplasty (TKA) is that achieving more natural kinematics will lead to superior patient outcomes. Yet this relationship has not been proven for large representative cohorts of TKA patients because accurately measuring 3-dimensional TKA kinematics is time-consuming and expensive. But advanced imaging systems and machine learning-enhanced analysis software will soon make it practical to measure knee kinematics preoperatively and postoperatively in the clinic using radiographic methods. The purpose of this study was to assess the reported relationships between TKA kinematics and outcomes and distill those findings into a proposal for a clinically practical protocol for a clinical kinematic exam. METHODS: This study reviewed the recent literature relating TKA kinematics to patient outcomes. There were 10 studies that reported statistical associations between TKA kinematics and patient outcome scores utilizing a range of functional activities. We stratified these activities by the complexity of the radiographic examination to create a proposed examination protocol, and we generated a list of requirements and characteristics for a practical TKA clinical kinematic examination. RESULTS: Given considerations for a clinically practical kinematic exam, including equipment, time and other resources, we propose 3 exam levels. With basic radiographs, we suggest studying single-leg stance in extension, lunge or squat, and kneeling. For fluoroscopic systems with X-ray pulses up to 20 ms, we propose chair-rise or stair ascent to provide additional dynamic information. For fluoroscopic systems with X-ray pulses of less than 10 ms, we propose rapid open-chain knee flexion-extension to simulate the highly dynamic swing phase of gait. CONCLUSIONS: It is our hope that this proposed examination protocol spurs discussion and debate so that there can be a consensus approach to clinical examination of knee and TKA kinematics when the rapidly advancing hardware and software capabilities are in place to do so.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Medición de Resultados Informados por el Paciente , Rango del Movimiento Articular , Humanos , Fenómenos Biomecánicos , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiología , Radiografía
5.
Artículo en Inglés | MEDLINE | ID: mdl-38071641

RESUMEN

INTRODUCTION: This study was aimed to assess the return to sport (RTS) rate in patients who underwent CT-based robotic-assisted unicompartmental knee arthroplasty (RA-UKA) and to evaluate the clinical performance and the assocition between patients' sport activity levels and Patient Reported Outcome Measures after surgery. MATERIALS AND METHODS: This retrospective study included 218 patients undergoing medial RA-UKA with fixed-bearing implants, performed at a single center between 2014 and 2019. Patients were allocated into two groups based on sport's practice and were administered the University of California, Los Angeles (UCLA) activity scale, Forgotten Joint Score-12 (FJS-12), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR) and the 5-Level Likert Scale. RESULTS: A total of 136 patients were included for assessment. The overall RTS rate after surgery was 93.1%. Six subjects who did not practice sport preoperatively, were able to start sport activities after surgery and all patients performing sports preoperatively, returned to same activity level. The mean UCLA and FJS-12 scores in the group of patients practicing sports were significantly higher than in the no-sport group (p < 0.001 and p < 0.05, respectively). Patients who practiced sports were more likely to attain higher FJS-12 and UCLA scores than those who were not performing physical activity. CONCLUSIONS: Patients undergoing RA-UKA showed a 93.1% RTS rate after surgery. Differences were detected in terms of postoperative UCLA and FJS-12 scores between patients who performed and who did not practice sport activities after surgery. High levels of postoperative UCLA scores were associated with higher KOOS-JR and patients' satisfaction.

6.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5477-5484, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37814136

RESUMEN

PURPOSE: The purpose of the present study was to determine the incidence of revision and report on clinical outcomes at a minimum of 10 years follow-up in patients who had received a medial unicompartmental knee arthroplasty (UKA) with an three-dimensional image-based robotic system. METHODS: A total of 239 patients (247 knees), who underwent medial robotic-arm assisted (RA)-UKA at a single center between April 2011 and June 2013, were assessed. The mean age at surgery was 67.0 years (SD 8.4). Post-operatively, patients were administered the Forgotten Joint Score-12 (FJS-12) and asked about their satisfaction (from 1 to 5). Post-operative complications were recorded. Failure mechanisms, revisions and reoperations were collected. Kaplan-Meier survival curves were calculated, considering revision as the event of interest. RESULTS: A total of 188 patients (196 knees) were assessed at a mean follow-up of 11.1 years (SD 0.5, range 10.0-11.9), resulting in a 79.4% follow-up rate. Seven RA-UKA underwent revision, resulting in a survivorship rate of 96.4% (CI 94.6%-99.2%). Causes of revision included aseptic loosening (2 cases), infection (1 case), post-traumatic (1 case), and unexplained pain (3 cases). The mean FJS-12 and satisfaction were 82.2 (SD 23.9) and 4.4 (SD 0.9), respectively. Majority of cases (174/196, 88.8%) attained the Patient Acceptable Symptoms State (PASS, FJS-12 > 40.63). Male subjects had a higher probability of attaining a "forgotten joint" (p < 0.001) and high satisfaction (equal to 5, p < 0.05), when compared to females. CONCLUSIONS: Three-dimensional image-based RA-UKA demonstrated high implant survivorship and good-to-excellent clinical outcomes at minimum 10 years follow-up. Pain of unknown origin represented the most common reason for RA-UKA revision. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Femenino , Humanos , Masculino , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios de Seguimiento , Procedimientos Quirúrgicos Robotizados/métodos , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía , Reoperación , Dolor/cirugía , Articulación de la Rodilla/cirugía , Estudios Retrospectivos
7.
Children (Basel) ; 10(8)2023 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-37628378

RESUMEN

BACKGROUND: Tibial eminence fractures (TEF) of Meyers-McKeever type II-III-IV usually require surgical management. No consensus in the literature has been achieved regarding the best treatment option. The aims of the present systematic review were (1) to analyze the current literature and describe the outcomes of surgical treatment for TEF; and (2) to compare the outcomes of different surgical options using arthroscopic reduction and internal fixation (ARIF) with sutures or screws and open reduction and internal fixation (ORIF). METHODS: A search was carried out with Pubmed, Medline, and Cochrane. Key terms were used "tibial" AND "eminence" or "spine" or "intercondylar" AND "paediatric" or "children" AND "fracture" or "avulsion" AND "treatment". Twelve articles met the inclusion criteria. Demographic data, clinical outcomes, and complication rates were evaluated for each study. Means/standard deviation and sum/percentage were used for continuous and categorical variables, respectively. Chi-square or t-student tests were applied. A p-value < 0.05 was considered statistically significant. RESULTS: ORIF showed superior clinical outcomes (Tegner (p < 0.05) and Lysholm (p < 0.001) scores) relative to ARIF and a lower incidence of arthrofibrosis (p < 0.05) and implant removal (p < 0.01). The Tegner, IKDC, and Lysholm scores showed statistically significant superior results following arthroscopic sutures compared to arthroscopic screws (p < 0.001). The incidence of arthrofibrosis was higher after arthroscopic sutures (p < 0.05), the implant removal was higher after screw fixation (p < 0.001) Conclusions: Better clinical results with low complication rates were achieved with ORIF surgery rather than ARIF; arthroscopic suture fixation resulted in higher clinical results compared to arthroscopic screw fixation and reduced the incidence of postoperative complications.

8.
Acta Biomed ; 94(S1): e2023134, 2023 06 05.
Artículo en Inglés | MEDLINE | ID: mdl-37272625

RESUMEN

In cruciate-retaining (CR) total knee arthroplasty (TKA) the preservation of the posterior cruciate ligament (PCL) provides joint stability and drives knee kinematics. No previous studies described in-vivo knee kinematics of PCL-deficient CR TKA. In the present case report it's described the in-vivo kinematic pattern change in a patient with post-operative PCL failure before and after insert replacement to a cruciate substituting (CS) design. In-vivo fluoroscopic analysis showed that PCL-deficient TKA showed more anterior translation of the lateral femoral condyle with respect to a cohort  of patients operated of CR-TKA with intact PCL, undergoing fluoroscopic analysis. The replacement to a CS design provided more external rotation of the femoral component and less anterior motion of the lateral condyle. The antero-posterior translation of the medial condyle was similar in PCL-deficient knee, CS TKA and controls. TKA with PCL deficiency showed more antero-posterior motion compared to TKAs with intact PCL and this can be source the of instability and a potential factor for patient's dissatisfaction. For this reason surgeons should attentively verify PCL integrity when performing a cruciate-sparing TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Ligamento Cruzado Posterior , Humanos , Ligamento Cruzado Posterior/cirugía , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Rango del Movimiento Articular , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía
9.
J Shoulder Elbow Surg ; 32(11): 2264-2275, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37263484

RESUMEN

BACKGROUND: Reverse shoulder arthroplasty (RSA) requiring extensive reaming to address severe glenoid bone loss increases the risk of glenoid medialization and baseplate failure. We hypothesized that (1) metal-augmented baseplate prevents the medialization of the joint line and preserves glenoid bone stock similarly to bony increased-offset (BIO)-RSA and (2) bone graft viability and healing in BIO-RSA patients become compromised over time. MATERIALS AND METHODS: Eighty-one patients (83 shoulders) underwent glenoid lateralization with bone (BIO-RSA group, 44) or metal-augmented baseplate (metallic increased-offset [MIO]-RSA group, 39) and a minimum follow-up of 24 months were included. The orientation and direction of glenoid erosion was identified and recorded using computerized 3D planning. Active range of motion, and the Western Ontario Osteoarthritis of the Shoulder (WOOS) index were assessed before arthroplasty and at the last follow-up visits. Radiographic changes around the glenoid and humeral components were assessed. Healing and thickness of bone graft were evaluated by predefined criteria. Postoperative global glenoid inclination (ß angle) and retroversion were also measured. RESULTS: Delta scores of active anterior elevation were higher in the MIO-RSA group (P = .027). The differences in the other planes of shoulder motion and in WOOS index scores between the groups were not significant. Preoperative glenoid retroversion was higher in BIO-RSA patients, and glenoid inclination was similar in both groups. Type B2 and B3 glenoids had a posterior-central (91%) and posterior-superior (90%) erosion with a mean posterior humeral head subluxation of 76% and 78%, respectively. The direction of erosion in type E2 and E3 glenoids was posterior-superior, with a mean posterior humeral head subluxation of 74%. The rate of high position of the glenosphere was higher in the BIO-RSA group (P = .022), whereas the values of ß angle and postoperative retroversion were similar in the 2 groups. BIO-RSA group showed radiolucent lines <2 mm around the bone graft in 16 patients (36.4%) and decreased thickness in 15 (34.1%). Incomplete baseplate seating was found in 4 MIO-RSA patients (10%). We found higher rates of humerus condensation lines in MIO-RSA patients (P = .01) and higher rates of cortical thinning and tuberosity resorption in the BIO-RSA group (P = .027 and P = .004, respectively). CONCLUSION: Metal-augmented glenoid is a suitable alternative to BIO-RSA to preserve bone and prevent the medialization of the joint line in arthritic glenoid with multiplanar glenoid deformity. Bone and metal augmentation provided satisfactory clinical outcomes. Bone graft resorption in BIO-RSA patients raise concern about the risk of baseplate loosening and requires further long-term studies.

10.
Arch Orthop Trauma Surg ; 143(9): 5649-5656, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37074371

RESUMEN

INTRODUCTION: One of the main causes of RSA failure is attributable to the malpositioning of the glenoid component. Initial experiences with computer-assisted surgery have shown promising results in increasing the accuracy and repeatability of placement of the glenoid component and screws. The aim of this study was to evaluate the functional clinical results, in terms of joint mobility and pain, by correlating them with intraoperative data regarding the positioning of the glenoid component. The hypothesis was that the lateralization more than 25 mm of the glenosphere can led to better stability of the prosthesis but should pay in term of a reduced range of movement and increased pain. MATERIALS AND METHODS: 50 patients were enrolled between October 2018 and May 2022; they underwent RSA implantation assisted by GPS navigation system. Active ROM, ASES score and VAS pain scale were recorded before surgery. Preoperative data about glenoid inclination and version were collected by pre-op X-Rays an CT. Intraoperative data-inclination, version, medialization and lateralization of the glenoid component-were recorded using computer-assisted surgery. 46 patients had been further clinically and radiographically re-evaluated at 3-months, 6-months, 1-year, and 2-years follow-up. RESULTS: We found a statistically significant correlation between anteposition and glenosphere lateralization value (DM - 6.057 mm; p = 0.043). Furthermore a statistically significant correlation has been shown between abduction movement and the lateralization value (DM - 7.723 mm; p = 0.015). No other statistically significant associations were found when comparing the values of glenoid inclination and version with the range of motion achieved by the patients after reverse shoulder arthroplasty. CONCLUSION: We observed that the patients with the best anteposition and abduction results had a glenosphere lateralization between 18 and 22 mm. When increasing the lateralization above 22 mm or reducing it below 18 mm, on the other hand, both movements considered decreased their range. LEVEL OF EVIDENCE: Level IV; Case Series; Treatment Study.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Escápula/cirugía , Dolor/cirugía , Rango del Movimiento Articular
11.
Knee ; 41: 391-396, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37088518

RESUMEN

BACKGROUND: The aim of this study was to deliver consensus recommendations for the clinical practice of unicompartmental knee arthroplasty (UKA). METHODS: Members of the British Association for Surgery of the Knee (BASK) and European Knee Society (EKS) were invited to attend a joint meeting in London, UK (December 2019). A formal consensus process was undertaken at the meeting incorporating a multiple round Delphi exercise, with group discussion of areas of agreement and disagreement between rounds. Eighty delegates attended the meeting and five consensus statements were considered and revised, with a threshold level of 80% agreement required as the definition consensus. RESULTS: Five consensus statements with accompanying supporting evidence and text were agreed following two rounds of the process: (1) UKA should be offered as a successful alternative to TKA in patients undergoing arthroplasty who meet agreed indications; (2) When consenting a patient for UKA, information including the benefits and risks that are specific to UKA, should be tailored to and discussed with the individual patient; (3) Evidence suggests that surgeons should avoid low-volume use of UKA to optimise outcomes for their patients; (4) Surgeons should use the contemporary evidence-based indications and contraindications for medial UKA; (5) Knee arthroplasty surgeons should have exposure to and training in UKA. CONCLUSIONS: The agreed joint BASK-EKS consensus statements on UKA practice are recommended as the contemporary basis of optimal care for these patients and should inform future training and service developments.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Consenso , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/etiología , Reoperación , Resultado del Tratamiento
12.
Int Orthop ; 47(3): 711-717, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36648533

RESUMEN

PURPOSE: To compare the clinical outcomes of subjects undergoing primary robotic-assisted total knee arthroplasty (RA-TKA), following functional alignment (FA) principles, with cruciate-retaining (CR) or posterior-stabilized (PS) bearing designs, at a minimum of 24 months of follow-up. METHODS: This observational, retrospective study included 167 consecutive patients undergoing RA-TKA with cemented PS and cementless CR implants performed with a CT-base robotic-arm assisted system (Mako, Stryker), following FA principles, between 2017 and 2020. Patients were followed up with a clinical and radiographic assessment and were administered the Forgotten Joint Score-12 (FJS-12), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR), and the 5-level Likert scale (5-LLS). RESULTS: Three TKA revisions were performed (2 PS, 1 CR); therefore, a total of 164 knees with a mean age of 71.7 years (SD 8.9) were considered (80 cemented PS; 84 cementless CR). No statistically significant differences were recorded between study groups relative to FJS-12, KOOS-JR, and 5-LLS at a minimum of two year follow-up (FJS-12 89.3 ± 9.2 vs 87.5 ± 12.8, p-value 0.46; KOOS-JR 88.8 ± 10.0 vs 86.7 ± 14.0, p-value 0.31; 5-LLS 4.5 ± 0.7 vs 4.5 ± 0.8, p-value 0.34). CONCLUSION: No significant outcome differences were reported between patients undergoing PS and CR RA-TKA at a minimum of two year follow-up. RA-TKA achieves excellent clinical results and high satisfaction scores, regardless of the implant design used.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Rango del Movimiento Articular , Osteoartritis de la Rodilla/cirugía
13.
Hip Int ; 33(3): 426-433, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35504896

RESUMEN

AIMS: Dislocation is a major cause of early failure after THA and is highly influenced by surgical approach and component positioning. Robotic-arm assisted arthroplasty has been developed in an attempt to improve component positioning and reduce postoperative complications.The purpose of this study was to compare the rate of dislocation after robotic total hip arthroplasty through 3 different surgical approaches. MATERIALS AND METHODS: All patients who had undergone robotic arm-assisted THA at 3 centres between 2014 and 2019 were reviewed. After applying exclusion criteria, 1059 patients were included in the study. An anterior approach was used in 323 patients, a lateral approach in 394 and a posterior approach in 342 patients.Episodes of dislocation were recorded after 6 months follow-up. Stem anteversion, cup anteversion, cup inclination and combined anteversion were collected using the integrated navigation system.Cumulative incidence (CI), incidence rate (IR) and risk ratio (RR) were calculated with a confidence interval of 95%. RESULTS: 3 cases of dislocation (2 posterior approach, 1 anterior approach) were recorded, with a dislocation rate of 0.28% and an IR of 0.14%.The rate of placement of the cup in the Lewinnek safe zone was 82.2% for the posterior approach, 82.0% for the lateral approach and 95.4% for the anterior approach.The rate of placement in the combined version safe zone was 98.0% for the posterior approach, 73.0% for the lateral approach and 47.1% for the anterior approach.The incidence rate of dislocation was 0.30% for the anterior approach, 0.34% for the posterior approach and 0% for the lateral approach. CONCLUSIONS: The robotic arm-assisted technique is associated with a low risk of dislocation. The combined version technique appears to be a reliable way to reduce the risk of dislocation through the posterolateral approach but does not appear to be essential when using the lateral and anterior approaches.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Acetábulo/cirugía , Procedimientos Quirúrgicos Robotizados/efectos adversos , Prótesis de Cadera/efectos adversos , Resultado del Tratamiento , Luxaciones Articulares/cirugía
14.
Int Orthop ; 47(2): 405-412, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36355081

RESUMEN

PURPOSE: Members of the European Knee Society (EKS) recently took part in an online questionnaire on robot-assisted TKA. The purpose of this study was to report and analyse the questionnaire results on the demographics of users versus non-users, the drivers for users of the technology, and the barriers or limitations that hinder the uptake of robot-assisted TKA. METHODS: The questionnaire was composed of 16 questions covering surgeon demographics and drivers for or barriers to the use of robotics. Responses on four- or five-point Likert scales were trichotomised depending on the type of question ("not important" - "moderately important" - "important/very important" or "fully disagree/disagree" - "neutral" - "agree/fully agree"). Consensus on a statement was defined as at least 75% agreement. RESULTS: There was a 67% response rate. Forty-five surgeons performed conventional TKA, of which 78% aimed for systematic alignment, while 22 performed robot-assisted TKA, of which 82% aimed for individualised alignment, and 16 performed technology-assisted TKA, of which 56% aimed for systematic alignment. Respondents agreed that robotics significantly impact accuracy of bone cuts (51/62, 82%), intra-operative feedback on ligament balancing (56/62, 90%) as well as bone cut orientation and implant positioning (57/ 62, 92%), and assistance to customise alignment (56/62, 90%). Respondents agreed that associated costs (14/18, 78%) are an important aspect for not using or to stop using robotics. CONCLUSION: The majority of respondents still perform conventional TKA (54%), while only a small portion perform robot-assisted TKA (27%) or other technology-assisted TKA (19%). Most robot users aim for individualised lower limb alignment, whereas most other surgeons aimed for systematic lower limb alignment. There is consensus that robotic assistance has a positive impact on accuracy of bone cuts and alignment, but no consensus on its impact on other peri- or post-operative outcomes. Finally, the associated cost of robot-assisted TKA remains the main barrier to its uptake. LEVEL OF EVIDENCE: V.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Robótica , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Robótica/métodos , Articulación de la Rodilla/cirugía , Extremidad Inferior/cirugía , Encuestas y Cuestionarios
15.
Int Orthop ; 47(2): 519-526, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36422703

RESUMEN

PURPOSE: Image-based robotic tools improve the accuracy of unicompartmental knee arthroplasty (UKA) positioning, but few studies have examined its effect on axial alignment. The aim of this study was to compare the characteristics of tibial and femoral implant positioning, mainly the tibial rotation, during medial or lateral UKA, performed with an image-based robotic assisted system. METHODS: A total of 71 UKA performed between September 2021 and June 2022 (53 medial and 18 lateral) were analyzed. All data regarding implant positioning (rotation, coronal and sagittal alignment) for tibial and femoral components were obtained using MAKO® software (Stryker®, Mahwah, USA) intra-operatively. RESULTS: The lateral UKA had a mean internal tibial rotation of 15.4 ± 3°, a mean external femoral rotation of 0.96 ± 2.4°, and a mean tibial slope of 4.7 ± 1.3°. The medial UKA had a mean internal tibial rotation of 0.18 ± 2.7°, a mean internal femoral rotation of 0.35 ± 2.2°, and a mean tibial slope of 5.4 ± 1.3°. The tibial rotations, femoral valgus, tibial varus and tibial size significantly differed between medial and lateral UKA (p < 0.05). There was no significant difference in femoral rotation, flexion, femoral size, slope, and polyethylene thickness between medial and lateral UKA. CONCLUSION: Medial and lateral UKA had significantly different implantation characteristics related to the biomechanics of the knee compartments. Image-based robotic UKA allowed precise femorotibial positioning per-operatively to match native kinematic alignment.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Fenómenos Biomecánicos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Tibia/cirugía , Osteoartritis de la Rodilla/cirugía
16.
J Orthop Traumatol ; 23(1): 51, 2022 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-36334166

RESUMEN

BACKGROUND: Proximal humeral fractures are commonly observed in elderly patients. Management of these injuries is controversial. Literature comparing locking plate fixation, arthroplasty, and conservative treatments show no clear advantages for any of these management strategies. Thus far, no study has considered anatomically reduced fractures obtained after locking plate treatment. To clarify the best surgical procedure in middle-aged patients, we considered outcomes and major complications leading to surgical revision following an anatomically reduced fracture fixed with locking plate and reverse shoulder arthroplasty (RSA) in the treatment of type B/C fractures in patients between 50 and 75 years of age. METHODS: This is a retrospective study including 59 patients between 50 and 75 years of age with type B/C proximal humeral fracture treated with RSA or with locking plate fixation (resulting in an anatomical reduction) between January 2010 and December 2018. Preoperative radiographs and computed tomography (CT) were evaluated in all patients. Clinical and radiologic follow-up was performed using range of motion (ROM), the Constant-Murley Score (CMS), the Oxford Shoulder Score (OSS), the Simple Shoulder Test (SST), the Subjective Shoulder Value (SSV), and visual analog scale (VAS). Major complications were considered. RESULTS: In the plate fixation group, ROM, CMS, SST, and VAS were higher than in the RSA group. Lower complication rates compared with the literature were observed in both groups. Anatomically reduced fracture fixed with plate and screw could outperform RSA in terms of outcome. In second-level centers where traumatology is performed by surgeons with great expertise in upper limb trauma, the choice between plate fixation and reverse arthroplasty should be made during surgery. CONCLUSION: Anatomically reduced fractures showed better outcomes compared with RSA in type B/C fractures. Surgeons should always try to perform a reduction of the fracture in order to understand if a plate fixation could be feasible. If it is impossible to perform an anatomical reduction, we suggest to consider RSA. This is a retrospective observational study.


Asunto(s)
Fracturas del Húmero , Fracturas del Hombro , Persona de Mediana Edad , Anciano , Humanos , Fracturas del Húmero/diagnóstico por imagen , Fracturas del Húmero/cirugía , Estudios Retrospectivos , Fijación Interna de Fracturas/métodos , Estudios de Seguimiento , Resultado del Tratamiento , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Placas Óseas/efectos adversos
17.
BMC Musculoskelet Disord ; 23(1): 963, 2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36348344

RESUMEN

BACKGROUND: Adipose tissue has recently gained growing interest in the treatment of osteoarthritis (OA). The aim of the present study was to evaluate the efficacy of a single injection of autologous micro-fragmented adipose tissue (aMFAT) associated with arthroscopy (cartilage debridement/meniscal regularization or selective meniscectomy/micro-drilling) for symptomatic knee OA. METHODS: This retrospective, single-center study included 49 patients (50 knees) affected by knee OA (radiographic Kellgren-Lawrence III-IV) treated with a single injection of autologous micro-fragmented adipose tissue and knee arthroscopy. Knee Injury and Osteoarthritis Outcome Score (KOOS) and subjective International Knee Documentation Committee (IKDC) score were the primary outcome measures and were collected at one and 2 years post-operatively. Patients were divided into clusters based on age, complexity of arthroscopic procedures and chondral lesion grade. RESULTS: Four patients underwent knee replacement (8%). No major adverse events were reported. Minimal Clinically Important Difference (MCID) for KOOS and IKDC was reached by 84 and 74% of all cases at 1 year and by 80 and 76% at 2 years, respectively. High grade chondral lesions negatively affected the outcome at 2 years follow-up (p < 0.05 for IKDC, KOOS overall and 3 out of 5 subscales). CONCLUSION: The injection of micro-fragmented adipose tissue associated with arthroscopy demonstrated to be a safe and effective procedure for the treatment of knee OA, with a substantial improvement in IKDC and KOOS scores and without major complications.


Asunto(s)
Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/patología , Artroscopía/efectos adversos , Artroscopía/métodos , Estudios Retrospectivos , Estudios de Seguimiento , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/patología , Tejido Adiposo/diagnóstico por imagen , Tejido Adiposo/cirugía , Resultado del Tratamiento
18.
Pharmaceutics ; 14(10)2022 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-36297562

RESUMEN

Osteonecrosis of the femoral head (ONFH) is a progressive degenerative disease that ultimately requires a total hip replacement. Mesenchymal stromal/stem cells (MSCs), particularly the ones isolated from bone marrow (BM), could be promising tools to restore bone tissue in ONFH. Here, we established a rabbit model to mimic the pathogenic features of human ONFH and to challenge an autologous MSC-based treatment. ON has been originally induced by the synergic combination of surgery and steroid administration. Autologous BM-MSCs were then implanted in the FH, aiming to restore the damaged tissue. Histological analyses confirmed bone formation in the BM-MSC treated rabbit femurs but not in the controls. In addition, the model also allowed investigations on BM-MSCs isolated before (ON-BM-MSCs) and after (ON+BM-MSCs) ON induction to dissect the impact of ON damage on MSC behavior in an affected microenvironment, accounting for those clinical approaches foreseeing MSCs generally isolated from affected patients. BM-MSCs, isolated before and after ON induction, revealed similar growth rates, immunophenotypic profiles, and differentiation abilities regardless of the ON. Our data support the use of ON+BM-MSCs as a promising autologous therapeutic tool to treat ON, paving the way for a more consolidated use into the clinical settings.

19.
J Knee Surg ; 35(11): 1214-1222, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33511590

RESUMEN

The purpose of this multicenter, retrospective, observational study was to investigate the association between intraoperative component positioning and soft tissue balancing, as reported by robotic technology for a cohort of patients who received robotic arm-assisted lateral unicompartmental knee arthroplasty (UKA) as well as short-term clinical follow-up of these patients. Between 2013 and 2016, 78 patients (79 knees) underwent robotic arm-assisted lateral UKAs at two centers. Pre- and postoperatively, patients were administered the Knee Injury and Osteoarthritis Score (KOOS) and the Forgotten Joint Score-12 (FJS-12). Clinical results were dichotomized based upon KOOS and FJS-12 scores into either excellent or fair outcome, considering excellent KOOS and FJS-12 to be greater than or equal to 90. Intraoperative, postimplantation robotic data relative to computed tomography-based components placement were collected and classified. Following exclusions and loss to follow-up, a total of 74 subjects (75 knees) who received robotic arm-assisted lateral UKAs were taken into account with an average follow-up of 36.3 months (range: 25.0-54.2 months) postoperative. Of these, 66 patients (67 knees) were included in the clinical outcome analysis. All postoperative clinical scores showed significant improvement compared with the preoperative evaluation. No association was reported between three-dimensional component positioning and soft tissue balancing throughout knee range of motion with overall KOOS, KOOS subscales, and FJS-12 scores. Lateral UKA three-dimensional placement does not seem to affect short-term clinical performance. However, precise boundaries for lateral UKA positioning and balancing should be taken into account. Robotic assistance allows surgeons to acquire real-time information regarding implant alignment and soft tissue balancing.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Artroplastia de Reemplazo de Rodilla/métodos , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Resultado del Tratamiento
20.
Injury ; 53 Suppl 1: S13-S18, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33678463

RESUMEN

BACKGROUND: Type III supracondylar fractures represent a difficult injury to treat and there is no universal consensus regarding the best treatment. The purpose of this study is to assess the incidence of complication associated with open reduction and compare open reduction vs closed reduction, in order to determine which treatment lead to better clinical and radiological outcomes. Is open reduction really associated with a higher number of iatrogenic complication and worse clinical outcomes in comparison to closed reduction? METHODS: A total of 55 patients, affected by type III supracondylar humerus fracture, were retrospectively selected and divided into two groups according to which type of treatment they received (open reduction or closed reduction). Major complications correlated with surgical procedure, such as infections, neurovascular iatrogenic lesions, elbow stiffness and painful scarring were assessed. The treatment outcomes and clinical features were compared among the two groups. A statistical analysis to find association between the type of reduction, the restored elbow anatomy and the clinical outcomes were performed. The follow-up varies between 1 year and 7 years. RESULTS: No major complications occurred in our series of patients. Excellent and good outcomes were reported among all 26 patients that underwent an open reduction surgery and in 23 out of the 29 patients who received a closed reduction surgery. A higher number of patients in the open reduction group presented angles with normal values; moreover 3 out of the 6 patients with unsatisfactory outcomes presented with angles not in range, underlying the presence of a connection between the restored elbow anatomy and the clinical outcomes. There were no differences among the two groups regarding the presence of complications. DISCUSSION: Open reduction should not be considered as a first line option of treatment in any pediatric patient with a type III supracondylar humerus fracture, but in several cases open surgery must be viewed as the choice with the best outcomes not only in presence of neurovascular lesion but also in case of irreducible fracture.


Asunto(s)
Articulación del Codo , Fracturas del Húmero , Niño , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/cirugía , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Humanos , Fracturas del Húmero/diagnóstico por imagen , Fracturas del Húmero/cirugía , Reducción Abierta/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA