Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Sep Sci ; 41(24): 4488-4497, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30352136

RESUMEN

An automated method for the analysis of methylparaben, propylparaben, benzophenone-3, and benzophenone-4 in water effluents via on-line solid-phase extraction coupled with high-performance liquid chromatography/ultraviolet detection was proposed. The preconcentration parameters were studied using Plackett-Burman and Box-Behnken experimental designs using a C18 sorbent material. The results demonstrated that the eluent volume, composition, and sorbent amount were statistically significant. Optimal conditions for these variables were an eluent volume of 1.55 mL, eluent composition of acetonitrile 100% v/v, and sorbent amount of 100 mg. The eluted sample was analyzed on-line using high-performance liquid chromatography equipped with a reversed-phase C18 column and ultraviolet detection. Separation of the analytes was achieved in 15 min using gradient elution with acetonitrile/water. A simple, sensitive, and rapid analytical method was proposed for personal care compounds without sophisticated or expensive equipment. The limits of detection were 1.20, 1.73, 2.51, and 4.67 µg/L for propylparaben, methylparaben, benzophenone-3, and benzophenone-4, respectively. The analysis time was 48 min, consuming only 1.59 mL of eluent acetonitrile for the solid phase extraction step, with minimal sample handling. The method was applied to the analysis of spiked swimming pool and wastewater, with recoveries between 65-107%. These results indicate the reliability of the flow-based procedure.


Asunto(s)
Benzofenonas/análisis , Fraccionamiento Químico , Parabenos/análisis , Extracción en Fase Sólida , Contaminantes Químicos del Agua/química , Cromatografía Líquida de Alta Presión , Espectrofotometría Ultravioleta
2.
J Environ Manage ; 129: 377-83, 2013 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-23994580

RESUMEN

A fully automated on-line system for monitoring the photocatalytic degradation of herbicides was developed using multisyringe flow injection analysis (MSFIA) coupled to a solid phase extraction (SPE) unit with UV detection. The calibration curves were linear in the concentration range of 100-1000 µg L(-1) for 3,6-dichloro-2-methoxybenzoic acid (dicamba) and 500-3000 µg L(-1) for 2,4-dichlorophenoxyacetic acid (2,4-D), while the detection limits were 30 and 135 µg L(-1) for dicamba and 2,4-D, respectively. The monitoring of the photocatalytic degradation (TiO2 anatase/UV 254 nm) of these two herbicides was performed by MSFIA-SPE system using a small sample volume (2 mL) in a fully automated approach. The degradation was assessed in ultrapure and drinking water with initial concentrations of 1000 and 2000 µg L(-1) for dicamba and 2,4-D, respectively. Degradation percentages of approximately 85% were obtained for both herbicides in ultrapure water after 45 min of photocatalytic treatment. A similar degradation efficiency in drinking water was observed for 2,4-D, whereas dicamba exhibited a lower degradation percentage (75%), which could be attributed to the presence of inorganic species in this kind of water.


Asunto(s)
Ácido 2,4-Diclorofenoxiacético/análisis , Dicamba/análisis , Monitoreo del Ambiente/métodos , Herbicidas/análisis , Sistemas en Línea , Contaminantes Químicos del Agua/análisis , Ácido 2,4-Diclorofenoxiacético/química , Dicamba/química , Monitoreo del Ambiente/instrumentación , Análisis de Inyección de Flujo/instrumentación , Análisis de Inyección de Flujo/métodos , Herbicidas/química , Sistemas en Línea/instrumentación , Fotólisis , Extracción en Fase Sólida/instrumentación , Extracción en Fase Sólida/métodos , Contaminantes Químicos del Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA